Evaluation of GI bleeding after implantation of left ventricular assist device

Background Left ventricular assist devices (LVADs) have revolutionized the management of end-stage heart failure (ESHF). However, unexpectedly high rates of GI bleeding (GIB) have been described, and etiology and outcome remain unclear. Objective To determine the prevalence, etiology, and outcome of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Gastrointestinal endoscopy 2012-05, Vol.75 (5), p.973-979
Hauptverfasser: Kushnir, Vladimir M., MD, Sharma, Shivak, MD, Ewald, Gregory A., MD, Seccombe, Jonathan, MD, Novak, Eric, MS, Wang, I-Wen, MD, PhD, Joseph, Susan M., MD, Gyawali, C. Prakash, MD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Left ventricular assist devices (LVADs) have revolutionized the management of end-stage heart failure (ESHF). However, unexpectedly high rates of GI bleeding (GIB) have been described, and etiology and outcome remain unclear. Objective To determine the prevalence, etiology, and outcome of GIB in LVAD recipients. Design Retrospective case series. Setting Tertiary care academic university hospital. Patients 154 ESHF patients (55.4 years, 122 men/32 women) with LVADs implanted over a 10-year period. Main outcome measurements Overt or occult GIB prompting endoscopic evaluation ≥7 days after LVAD implantation. Results Over a mean of 0.9 ± 0.1 years of follow-up, 29 patients (19%) experienced 44 GIB episodes. Patients with GIB were older and received anticoagulation therapy before devices were implanted ( P ≤ .02 for each). GIB was overt (n = 31) rather than occult (n = 13), and most patients presented with melena (n = 22, 50%); hemodynamic instability was observed in 13.6%. Each bleeding episode required 2.1 ± 0.1 diagnostic or therapeutic procedures, and a source was localized in 71%. Upper endoscopy provided the highest diagnostic yield; peptic bleeding (n = 14) and vascular malformations (n = 8) dominated the findings. Endoscopy was safe and well tolerated. Overall mortality was 35%, none directly from GIB. Limitation Retrospective design. Conclusions Rates of GIB with LVADs are higher than that seen in other patient populations, including those receiving anticoagulation and antiplatelet therapy. GIB episodes are mostly overt and predominantly from the upper GI tract. Endoscopy is safe in the LVAD population.
ISSN:0016-5107
1097-6779
DOI:10.1016/j.gie.2011.12.014