Phantom and mouse experiments of time-domain fluorescence tomography using total light approach
Phantom and mouse experiments of time-domain fluorescence tomography were conducted to demonstrate the total light approach which was previously proposed by authors. The total light approach reduces the computation time to solve the forward model for light propagation. Time-resolved temporal profile...
Gespeichert in:
Veröffentlicht in: | Biomedical optics express 2013-04, Vol.4 (4), p.635-651 |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 651 |
---|---|
container_issue | 4 |
container_start_page | 635 |
container_title | Biomedical optics express |
container_volume | 4 |
creator | Okawa, Shinpei Yano, Akira Uchida, Kazuki Mitsui, Yohei Yoshida, Masaki Takekoshi, Masashi Marjono, Andhi Gao, Feng Hoshi, Yoko Kida, Ikuhiro Masamoto, Kazuto Yamada, Yukio |
description | Phantom and mouse experiments of time-domain fluorescence tomography were conducted to demonstrate the total light approach which was previously proposed by authors. The total light approach reduces the computation time to solve the forward model for light propagation. Time-resolved temporal profiles were acquired for cylindrical phantoms having single or double targets containing indocyanine green (ICG) solutions. The reconstructed images of ICG concentration reflected the true distributions of ICG concentration with a spatial resolution of about 10 mm. In vivo experiments were conducted using a mouse in which an ICG capsule was embedded beneath the skin in the abdomen. The reconstructed image of the ICG concentration again reflected the true distribution of ICG although artifacts due to autofluorescence appeared in the vicinity of the skin. The effectiveness of the total light approach was demonstrated by the phantom and mouse experiments. |
doi_str_mv | 10.1364/boe.4.000635 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3617724</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1326728777</sourcerecordid><originalsourceid>FETCH-LOGICAL-c450t-b013d77519d3b0c6380f5f612fb4d7de9604fc6f437769d295bfb91d2fb49c953</originalsourceid><addsrcrecordid>eNpVkTtPwzAUhS0Eoqh0Y0YeGUix41ezIEFVHlKlMsBsObHdBCVxsBNE_z2uWqoy-cr3u-c-DgBXGE0x4fQud2ZKpwghTtgJuEgx44lAM3Z6FI_AJITPyCBKBSKzczBKCRMizcQFkG-lanvXQNVq2LghGGh-OuOrxrR9gM7CPoaJdo2qWmjrwXkTCtMWBsYqt_aqKzdwCFW7jh-9qmFdrcseqq7zThXlJTizqg5msn_H4ONp8T5_SZar59f5wzIpKEN9kiNMtBAMZ5rkqOBkhiyzHKc2p1pok3FEbcEtJULwTKcZy22eYb3NZ0XGyBjc73S7IW-MjhP2XtWyi4sov5FOVfJ_pq1KuXbfknAcT0GjwM1ewLuvwYReNlVctK5Va-JZJCYpF-lMCBHR2x1aeBeCN_bQBiO5tUU-rhaSyp0tEb8-Hu0A_5lAfgGS34rF</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1326728777</pqid></control><display><type>article</type><title>Phantom and mouse experiments of time-domain fluorescence tomography using total light approach</title><source>DOAJ Directory of Open Access Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central</source><creator>Okawa, Shinpei ; Yano, Akira ; Uchida, Kazuki ; Mitsui, Yohei ; Yoshida, Masaki ; Takekoshi, Masashi ; Marjono, Andhi ; Gao, Feng ; Hoshi, Yoko ; Kida, Ikuhiro ; Masamoto, Kazuto ; Yamada, Yukio</creator><creatorcontrib>Okawa, Shinpei ; Yano, Akira ; Uchida, Kazuki ; Mitsui, Yohei ; Yoshida, Masaki ; Takekoshi, Masashi ; Marjono, Andhi ; Gao, Feng ; Hoshi, Yoko ; Kida, Ikuhiro ; Masamoto, Kazuto ; Yamada, Yukio</creatorcontrib><description>Phantom and mouse experiments of time-domain fluorescence tomography were conducted to demonstrate the total light approach which was previously proposed by authors. The total light approach reduces the computation time to solve the forward model for light propagation. Time-resolved temporal profiles were acquired for cylindrical phantoms having single or double targets containing indocyanine green (ICG) solutions. The reconstructed images of ICG concentration reflected the true distributions of ICG concentration with a spatial resolution of about 10 mm. In vivo experiments were conducted using a mouse in which an ICG capsule was embedded beneath the skin in the abdomen. The reconstructed image of the ICG concentration again reflected the true distribution of ICG although artifacts due to autofluorescence appeared in the vicinity of the skin. The effectiveness of the total light approach was demonstrated by the phantom and mouse experiments.</description><identifier>ISSN: 2156-7085</identifier><identifier>EISSN: 2156-7085</identifier><identifier>DOI: 10.1364/boe.4.000635</identifier><identifier>PMID: 23577297</identifier><language>eng</language><publisher>United States: Optical Society of America</publisher><subject>Diffuse Optical Imaging</subject><ispartof>Biomedical optics express, 2013-04, Vol.4 (4), p.635-651</ispartof><rights>2013 Optical Society of America 2013 OSA</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c450t-b013d77519d3b0c6380f5f612fb4d7de9604fc6f437769d295bfb91d2fb49c953</citedby><cites>FETCH-LOGICAL-c450t-b013d77519d3b0c6380f5f612fb4d7de9604fc6f437769d295bfb91d2fb49c953</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3617724/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3617724/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,864,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23577297$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Okawa, Shinpei</creatorcontrib><creatorcontrib>Yano, Akira</creatorcontrib><creatorcontrib>Uchida, Kazuki</creatorcontrib><creatorcontrib>Mitsui, Yohei</creatorcontrib><creatorcontrib>Yoshida, Masaki</creatorcontrib><creatorcontrib>Takekoshi, Masashi</creatorcontrib><creatorcontrib>Marjono, Andhi</creatorcontrib><creatorcontrib>Gao, Feng</creatorcontrib><creatorcontrib>Hoshi, Yoko</creatorcontrib><creatorcontrib>Kida, Ikuhiro</creatorcontrib><creatorcontrib>Masamoto, Kazuto</creatorcontrib><creatorcontrib>Yamada, Yukio</creatorcontrib><title>Phantom and mouse experiments of time-domain fluorescence tomography using total light approach</title><title>Biomedical optics express</title><addtitle>Biomed Opt Express</addtitle><description>Phantom and mouse experiments of time-domain fluorescence tomography were conducted to demonstrate the total light approach which was previously proposed by authors. The total light approach reduces the computation time to solve the forward model for light propagation. Time-resolved temporal profiles were acquired for cylindrical phantoms having single or double targets containing indocyanine green (ICG) solutions. The reconstructed images of ICG concentration reflected the true distributions of ICG concentration with a spatial resolution of about 10 mm. In vivo experiments were conducted using a mouse in which an ICG capsule was embedded beneath the skin in the abdomen. The reconstructed image of the ICG concentration again reflected the true distribution of ICG although artifacts due to autofluorescence appeared in the vicinity of the skin. The effectiveness of the total light approach was demonstrated by the phantom and mouse experiments.</description><subject>Diffuse Optical Imaging</subject><issn>2156-7085</issn><issn>2156-7085</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNpVkTtPwzAUhS0Eoqh0Y0YeGUix41ezIEFVHlKlMsBsObHdBCVxsBNE_z2uWqoy-cr3u-c-DgBXGE0x4fQud2ZKpwghTtgJuEgx44lAM3Z6FI_AJITPyCBKBSKzczBKCRMizcQFkG-lanvXQNVq2LghGGh-OuOrxrR9gM7CPoaJdo2qWmjrwXkTCtMWBsYqt_aqKzdwCFW7jh-9qmFdrcseqq7zThXlJTizqg5msn_H4ONp8T5_SZar59f5wzIpKEN9kiNMtBAMZ5rkqOBkhiyzHKc2p1pok3FEbcEtJULwTKcZy22eYb3NZ0XGyBjc73S7IW-MjhP2XtWyi4sov5FOVfJ_pq1KuXbfknAcT0GjwM1ewLuvwYReNlVctK5Va-JZJCYpF-lMCBHR2x1aeBeCN_bQBiO5tUU-rhaSyp0tEb8-Hu0A_5lAfgGS34rF</recordid><startdate>20130401</startdate><enddate>20130401</enddate><creator>Okawa, Shinpei</creator><creator>Yano, Akira</creator><creator>Uchida, Kazuki</creator><creator>Mitsui, Yohei</creator><creator>Yoshida, Masaki</creator><creator>Takekoshi, Masashi</creator><creator>Marjono, Andhi</creator><creator>Gao, Feng</creator><creator>Hoshi, Yoko</creator><creator>Kida, Ikuhiro</creator><creator>Masamoto, Kazuto</creator><creator>Yamada, Yukio</creator><general>Optical Society of America</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20130401</creationdate><title>Phantom and mouse experiments of time-domain fluorescence tomography using total light approach</title><author>Okawa, Shinpei ; Yano, Akira ; Uchida, Kazuki ; Mitsui, Yohei ; Yoshida, Masaki ; Takekoshi, Masashi ; Marjono, Andhi ; Gao, Feng ; Hoshi, Yoko ; Kida, Ikuhiro ; Masamoto, Kazuto ; Yamada, Yukio</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c450t-b013d77519d3b0c6380f5f612fb4d7de9604fc6f437769d295bfb91d2fb49c953</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Diffuse Optical Imaging</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Okawa, Shinpei</creatorcontrib><creatorcontrib>Yano, Akira</creatorcontrib><creatorcontrib>Uchida, Kazuki</creatorcontrib><creatorcontrib>Mitsui, Yohei</creatorcontrib><creatorcontrib>Yoshida, Masaki</creatorcontrib><creatorcontrib>Takekoshi, Masashi</creatorcontrib><creatorcontrib>Marjono, Andhi</creatorcontrib><creatorcontrib>Gao, Feng</creatorcontrib><creatorcontrib>Hoshi, Yoko</creatorcontrib><creatorcontrib>Kida, Ikuhiro</creatorcontrib><creatorcontrib>Masamoto, Kazuto</creatorcontrib><creatorcontrib>Yamada, Yukio</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Biomedical optics express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Okawa, Shinpei</au><au>Yano, Akira</au><au>Uchida, Kazuki</au><au>Mitsui, Yohei</au><au>Yoshida, Masaki</au><au>Takekoshi, Masashi</au><au>Marjono, Andhi</au><au>Gao, Feng</au><au>Hoshi, Yoko</au><au>Kida, Ikuhiro</au><au>Masamoto, Kazuto</au><au>Yamada, Yukio</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Phantom and mouse experiments of time-domain fluorescence tomography using total light approach</atitle><jtitle>Biomedical optics express</jtitle><addtitle>Biomed Opt Express</addtitle><date>2013-04-01</date><risdate>2013</risdate><volume>4</volume><issue>4</issue><spage>635</spage><epage>651</epage><pages>635-651</pages><issn>2156-7085</issn><eissn>2156-7085</eissn><abstract>Phantom and mouse experiments of time-domain fluorescence tomography were conducted to demonstrate the total light approach which was previously proposed by authors. The total light approach reduces the computation time to solve the forward model for light propagation. Time-resolved temporal profiles were acquired for cylindrical phantoms having single or double targets containing indocyanine green (ICG) solutions. The reconstructed images of ICG concentration reflected the true distributions of ICG concentration with a spatial resolution of about 10 mm. In vivo experiments were conducted using a mouse in which an ICG capsule was embedded beneath the skin in the abdomen. The reconstructed image of the ICG concentration again reflected the true distribution of ICG although artifacts due to autofluorescence appeared in the vicinity of the skin. The effectiveness of the total light approach was demonstrated by the phantom and mouse experiments.</abstract><cop>United States</cop><pub>Optical Society of America</pub><pmid>23577297</pmid><doi>10.1364/boe.4.000635</doi><tpages>17</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2156-7085 |
ispartof | Biomedical optics express, 2013-04, Vol.4 (4), p.635-651 |
issn | 2156-7085 2156-7085 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3617724 |
source | DOAJ Directory of Open Access Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central |
subjects | Diffuse Optical Imaging |
title | Phantom and mouse experiments of time-domain fluorescence tomography using total light approach |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-19T01%3A43%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Phantom%20and%20mouse%20experiments%20of%20time-domain%20fluorescence%20tomography%20using%20total%20light%20approach&rft.jtitle=Biomedical%20optics%20express&rft.au=Okawa,%20Shinpei&rft.date=2013-04-01&rft.volume=4&rft.issue=4&rft.spage=635&rft.epage=651&rft.pages=635-651&rft.issn=2156-7085&rft.eissn=2156-7085&rft_id=info:doi/10.1364/boe.4.000635&rft_dat=%3Cproquest_pubme%3E1326728777%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1326728777&rft_id=info:pmid/23577297&rfr_iscdi=true |