Targeted vertical cross-sectional imaging with handheld near-infrared dual axes confocal fluorescence endomicroscope
We demonstrate vertical cross-sectional (XZ-plane) images of near-infrared (NIR) fluorescence with a handheld dual axes confocal endomicroscope that reveals specific binding of a Cy5.5-labeled peptide to pre-malignant colonic mucosa. This view is perpendicular to the tissue surface, and is similar t...
Gespeichert in:
Veröffentlicht in: | Biomedical optics express 2013-02, Vol.4 (2), p.322-330 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 330 |
---|---|
container_issue | 2 |
container_start_page | 322 |
container_title | Biomedical optics express |
container_volume | 4 |
creator | Qiu, Zhen Liu, Zhongyao Duan, Xiyu Khondee, Supang Joshi, Bishnu Mandella, Michael J Oldham, Kenn Kurabayashi, Katsuo Wang, Thomas D |
description | We demonstrate vertical cross-sectional (XZ-plane) images of near-infrared (NIR) fluorescence with a handheld dual axes confocal endomicroscope that reveals specific binding of a Cy5.5-labeled peptide to pre-malignant colonic mucosa. This view is perpendicular to the tissue surface, and is similar to that used by pathologists. The scan head is 10 mm in outer diameter (OD), and integrates a one dimensional (1-D) microelectromechanical systems (MEMS) X-axis scanner and a bulky lead zirconate titanate (PZT) based Z-axis actuator. The microscope images in a raster-scanning pattern with a ±6 degrees (mechanical) scan angle at ~3 kHz in the X-axis (fast) and up to 10 Hz (0-400 μm) in the Z-axis (slow). Vertical cross-sectional fluorescence images are collected with a transverse and axial resolution of 4 and 5 μm, respectively, over a field-of-view of 800 μm (width) × 400 μm (depth). NIR vertical cross-sectional fluorescence images of fresh mouse colonic mucosa demonstrate histology-like imaging performance with this miniature instrument. |
doi_str_mv | 10.1364/BOE.4.000322 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3567718</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1288314765</sourcerecordid><originalsourceid>FETCH-LOGICAL-c384t-e45202ad220376a880da75e17c83d7b4c152ecd64add229c06af57c6fac717353</originalsourceid><addsrcrecordid>eNpVkc9PHCEUx4mpUaPePJs59tBZ-Q29NGmNbU1MvOiZPOHNLs0sbGHG1v9etmuNnoDw4fPe40vIGaMLJrS8-HZ7tZALSqngfI8ccaZ0b6hVH97sD8lprb8aQ6U0VNgDcsiFZFxpeUSmOyhLnDB0j1im6GHsfMm19hX9FHNq57iGZUzL7k-cVt0KUljhGLqEUPqYhgKlPQ5zA-Ev1s7nNOStZhjnXLB6TB47TCGv49bs8wZPyP4AY8XTl_WY3H-_urv82d_c_ri-_HrTe2Hl1KNUnHIInFNhNFhLAxiFzHgrgnmQnimOPmgJoTGfPdUwKOP1AN4wI5Q4Jl923s38sMbQWpkKjG5T2kjlyWWI7v1Niiu3zI9OKG0Ms03w8UVQ8u8Z6-TWsU00jpAwz9Uxbq1g0uhtrU879N_3FRxeyzDqtlm5lpWTbpdVw8_ftvYK_09GPANyiZJb</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1288314765</pqid></control><display><type>article</type><title>Targeted vertical cross-sectional imaging with handheld near-infrared dual axes confocal fluorescence endomicroscope</title><source>DOAJ Directory of Open Access Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><creator>Qiu, Zhen ; Liu, Zhongyao ; Duan, Xiyu ; Khondee, Supang ; Joshi, Bishnu ; Mandella, Michael J ; Oldham, Kenn ; Kurabayashi, Katsuo ; Wang, Thomas D</creator><creatorcontrib>Qiu, Zhen ; Liu, Zhongyao ; Duan, Xiyu ; Khondee, Supang ; Joshi, Bishnu ; Mandella, Michael J ; Oldham, Kenn ; Kurabayashi, Katsuo ; Wang, Thomas D</creatorcontrib><description>We demonstrate vertical cross-sectional (XZ-plane) images of near-infrared (NIR) fluorescence with a handheld dual axes confocal endomicroscope that reveals specific binding of a Cy5.5-labeled peptide to pre-malignant colonic mucosa. This view is perpendicular to the tissue surface, and is similar to that used by pathologists. The scan head is 10 mm in outer diameter (OD), and integrates a one dimensional (1-D) microelectromechanical systems (MEMS) X-axis scanner and a bulky lead zirconate titanate (PZT) based Z-axis actuator. The microscope images in a raster-scanning pattern with a ±6 degrees (mechanical) scan angle at ~3 kHz in the X-axis (fast) and up to 10 Hz (0-400 μm) in the Z-axis (slow). Vertical cross-sectional fluorescence images are collected with a transverse and axial resolution of 4 and 5 μm, respectively, over a field-of-view of 800 μm (width) × 400 μm (depth). NIR vertical cross-sectional fluorescence images of fresh mouse colonic mucosa demonstrate histology-like imaging performance with this miniature instrument.</description><identifier>ISSN: 2156-7085</identifier><identifier>EISSN: 2156-7085</identifier><identifier>DOI: 10.1364/BOE.4.000322</identifier><identifier>PMID: 23412564</identifier><language>eng</language><publisher>United States: Optical Society of America</publisher><subject>Microscopy</subject><ispartof>Biomedical optics express, 2013-02, Vol.4 (2), p.322-330</ispartof><rights>2013 Optical Society of America 2013 OSA</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c384t-e45202ad220376a880da75e17c83d7b4c152ecd64add229c06af57c6fac717353</citedby><cites>FETCH-LOGICAL-c384t-e45202ad220376a880da75e17c83d7b4c152ecd64add229c06af57c6fac717353</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3567718/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3567718/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,315,729,782,786,866,887,27933,27934,53800,53802</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23412564$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Qiu, Zhen</creatorcontrib><creatorcontrib>Liu, Zhongyao</creatorcontrib><creatorcontrib>Duan, Xiyu</creatorcontrib><creatorcontrib>Khondee, Supang</creatorcontrib><creatorcontrib>Joshi, Bishnu</creatorcontrib><creatorcontrib>Mandella, Michael J</creatorcontrib><creatorcontrib>Oldham, Kenn</creatorcontrib><creatorcontrib>Kurabayashi, Katsuo</creatorcontrib><creatorcontrib>Wang, Thomas D</creatorcontrib><title>Targeted vertical cross-sectional imaging with handheld near-infrared dual axes confocal fluorescence endomicroscope</title><title>Biomedical optics express</title><addtitle>Biomed Opt Express</addtitle><description>We demonstrate vertical cross-sectional (XZ-plane) images of near-infrared (NIR) fluorescence with a handheld dual axes confocal endomicroscope that reveals specific binding of a Cy5.5-labeled peptide to pre-malignant colonic mucosa. This view is perpendicular to the tissue surface, and is similar to that used by pathologists. The scan head is 10 mm in outer diameter (OD), and integrates a one dimensional (1-D) microelectromechanical systems (MEMS) X-axis scanner and a bulky lead zirconate titanate (PZT) based Z-axis actuator. The microscope images in a raster-scanning pattern with a ±6 degrees (mechanical) scan angle at ~3 kHz in the X-axis (fast) and up to 10 Hz (0-400 μm) in the Z-axis (slow). Vertical cross-sectional fluorescence images are collected with a transverse and axial resolution of 4 and 5 μm, respectively, over a field-of-view of 800 μm (width) × 400 μm (depth). NIR vertical cross-sectional fluorescence images of fresh mouse colonic mucosa demonstrate histology-like imaging performance with this miniature instrument.</description><subject>Microscopy</subject><issn>2156-7085</issn><issn>2156-7085</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNpVkc9PHCEUx4mpUaPePJs59tBZ-Q29NGmNbU1MvOiZPOHNLs0sbGHG1v9etmuNnoDw4fPe40vIGaMLJrS8-HZ7tZALSqngfI8ccaZ0b6hVH97sD8lprb8aQ6U0VNgDcsiFZFxpeUSmOyhLnDB0j1im6GHsfMm19hX9FHNq57iGZUzL7k-cVt0KUljhGLqEUPqYhgKlPQ5zA-Ev1s7nNOStZhjnXLB6TB47TCGv49bs8wZPyP4AY8XTl_WY3H-_urv82d_c_ri-_HrTe2Hl1KNUnHIInFNhNFhLAxiFzHgrgnmQnimOPmgJoTGfPdUwKOP1AN4wI5Q4Jl923s38sMbQWpkKjG5T2kjlyWWI7v1Niiu3zI9OKG0Ms03w8UVQ8u8Z6-TWsU00jpAwz9Uxbq1g0uhtrU879N_3FRxeyzDqtlm5lpWTbpdVw8_ftvYK_09GPANyiZJb</recordid><startdate>20130201</startdate><enddate>20130201</enddate><creator>Qiu, Zhen</creator><creator>Liu, Zhongyao</creator><creator>Duan, Xiyu</creator><creator>Khondee, Supang</creator><creator>Joshi, Bishnu</creator><creator>Mandella, Michael J</creator><creator>Oldham, Kenn</creator><creator>Kurabayashi, Katsuo</creator><creator>Wang, Thomas D</creator><general>Optical Society of America</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20130201</creationdate><title>Targeted vertical cross-sectional imaging with handheld near-infrared dual axes confocal fluorescence endomicroscope</title><author>Qiu, Zhen ; Liu, Zhongyao ; Duan, Xiyu ; Khondee, Supang ; Joshi, Bishnu ; Mandella, Michael J ; Oldham, Kenn ; Kurabayashi, Katsuo ; Wang, Thomas D</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c384t-e45202ad220376a880da75e17c83d7b4c152ecd64add229c06af57c6fac717353</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Microscopy</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Qiu, Zhen</creatorcontrib><creatorcontrib>Liu, Zhongyao</creatorcontrib><creatorcontrib>Duan, Xiyu</creatorcontrib><creatorcontrib>Khondee, Supang</creatorcontrib><creatorcontrib>Joshi, Bishnu</creatorcontrib><creatorcontrib>Mandella, Michael J</creatorcontrib><creatorcontrib>Oldham, Kenn</creatorcontrib><creatorcontrib>Kurabayashi, Katsuo</creatorcontrib><creatorcontrib>Wang, Thomas D</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Biomedical optics express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Qiu, Zhen</au><au>Liu, Zhongyao</au><au>Duan, Xiyu</au><au>Khondee, Supang</au><au>Joshi, Bishnu</au><au>Mandella, Michael J</au><au>Oldham, Kenn</au><au>Kurabayashi, Katsuo</au><au>Wang, Thomas D</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Targeted vertical cross-sectional imaging with handheld near-infrared dual axes confocal fluorescence endomicroscope</atitle><jtitle>Biomedical optics express</jtitle><addtitle>Biomed Opt Express</addtitle><date>2013-02-01</date><risdate>2013</risdate><volume>4</volume><issue>2</issue><spage>322</spage><epage>330</epage><pages>322-330</pages><issn>2156-7085</issn><eissn>2156-7085</eissn><abstract>We demonstrate vertical cross-sectional (XZ-plane) images of near-infrared (NIR) fluorescence with a handheld dual axes confocal endomicroscope that reveals specific binding of a Cy5.5-labeled peptide to pre-malignant colonic mucosa. This view is perpendicular to the tissue surface, and is similar to that used by pathologists. The scan head is 10 mm in outer diameter (OD), and integrates a one dimensional (1-D) microelectromechanical systems (MEMS) X-axis scanner and a bulky lead zirconate titanate (PZT) based Z-axis actuator. The microscope images in a raster-scanning pattern with a ±6 degrees (mechanical) scan angle at ~3 kHz in the X-axis (fast) and up to 10 Hz (0-400 μm) in the Z-axis (slow). Vertical cross-sectional fluorescence images are collected with a transverse and axial resolution of 4 and 5 μm, respectively, over a field-of-view of 800 μm (width) × 400 μm (depth). NIR vertical cross-sectional fluorescence images of fresh mouse colonic mucosa demonstrate histology-like imaging performance with this miniature instrument.</abstract><cop>United States</cop><pub>Optical Society of America</pub><pmid>23412564</pmid><doi>10.1364/BOE.4.000322</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2156-7085 |
ispartof | Biomedical optics express, 2013-02, Vol.4 (2), p.322-330 |
issn | 2156-7085 2156-7085 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3567718 |
source | DOAJ Directory of Open Access Journals; EZB-FREE-00999 freely available EZB journals; PubMed Central |
subjects | Microscopy |
title | Targeted vertical cross-sectional imaging with handheld near-infrared dual axes confocal fluorescence endomicroscope |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-03T10%3A52%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Targeted%20vertical%20cross-sectional%20imaging%20with%20handheld%20near-infrared%20dual%20axes%20confocal%20fluorescence%20endomicroscope&rft.jtitle=Biomedical%20optics%20express&rft.au=Qiu,%20Zhen&rft.date=2013-02-01&rft.volume=4&rft.issue=2&rft.spage=322&rft.epage=330&rft.pages=322-330&rft.issn=2156-7085&rft.eissn=2156-7085&rft_id=info:doi/10.1364/BOE.4.000322&rft_dat=%3Cproquest_pubme%3E1288314765%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1288314765&rft_id=info:pmid/23412564&rfr_iscdi=true |