A new interventional technique for percutaneous treatment of drainage-resistant liver abscess

The objective of this case report is to describe a device that can be used as a minimally invasive alternative for the treatment of drainage-resistant liver abscess. The device uses pulse lavage to fragment and evacuate the semi-solid contents of a liver abscess. The treatment of liver abscesses con...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:British journal of radiology 2010-09, Vol.83 (993), p.e195-e197
Hauptverfasser: De Jong, K P, Prins, T R, Hofker, H S
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page e197
container_issue 993
container_start_page e195
container_title British journal of radiology
container_volume 83
creator De Jong, K P
Prins, T R
Hofker, H S
description The objective of this case report is to describe a device that can be used as a minimally invasive alternative for the treatment of drainage-resistant liver abscess. The device uses pulse lavage to fragment and evacuate the semi-solid contents of a liver abscess. The treatment of liver abscesses consists of percutaneous drainage, antibiotics and treatment of the underlying cause. This approach can be ineffective if the contents of the abscess cavity are not liquid, and in those cases open surgery is often needed. Here, we describe for the first time a new minimally invasive technique for treating persistent liver abscesses. A patient developed a liver abscess after a hepatico-jejunostomy performed as a palliative treatment for an unresectable pancreatic head carcinoma. Simple drainage by a percutaneously placed pig-tail catheter was insufficient because of inadequate removal of the contents of the abscess cavity. After dilatation of the drain tract the persistent semi-solid necrotic contents were fragmented by a pulsed lavage device, after which the abscess healed uneventfully. The application of pulsed lavage for debridement of drainage-resistant liver abscesses proved to be an effective and minimally invasive alternative to open surgery.
doi_str_mv 10.1259/bjr/69471744
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3473396</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>748993352</sourcerecordid><originalsourceid>FETCH-LOGICAL-c383t-a8d2e735baca92b89e4a8387a9e80f0b288545a4b45e395bef99c774d705c2c63</originalsourceid><addsrcrecordid>eNpVkctLAzEQxoMoWh83z5KbF1ezeTTJRSjiCwQvCl4kZLOzbWQfNUkr_vem1BY9DcP8-Ga--RA6LcllSYW-qj7C1VhzWUrOd9AoF1UoRd520YgQIouSKnGADmP8WLVCk310QIlkmnE6Qu8T3MMX9n2CsIQ--aG3LU7gZr3_XABuhoDnENwi2R6GRcQpgE1dJvHQ4DpY39spFAGijxlJuPVLCNhW0UGMx2ivsW2Ek996hF7vbl9uHoqn5_vHm8lT4ZhiqbCqpiCZqKyzmlZKA7eKKWk1KNKQiioluLC84gKYFhU0WjspeS2JcNSN2RG6XuvOF1UHtcvnBduaefCdDd9msN78n_R-ZqbD0jAuGdMrgfNfgTBk2zGZzmcHbbt2bfJTtWZM0ExerEkXhhgDNNstJTGrQEwOxGwCyfjZ38u28CYB9gPAzIou</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>748993352</pqid></control><display><type>article</type><title>A new interventional technique for percutaneous treatment of drainage-resistant liver abscess</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Oxford University Press Journals All Titles (1996-Current)</source><creator>De Jong, K P ; Prins, T R ; Hofker, H S</creator><creatorcontrib>De Jong, K P ; Prins, T R ; Hofker, H S</creatorcontrib><description>The objective of this case report is to describe a device that can be used as a minimally invasive alternative for the treatment of drainage-resistant liver abscess. The device uses pulse lavage to fragment and evacuate the semi-solid contents of a liver abscess. The treatment of liver abscesses consists of percutaneous drainage, antibiotics and treatment of the underlying cause. This approach can be ineffective if the contents of the abscess cavity are not liquid, and in those cases open surgery is often needed. Here, we describe for the first time a new minimally invasive technique for treating persistent liver abscesses. A patient developed a liver abscess after a hepatico-jejunostomy performed as a palliative treatment for an unresectable pancreatic head carcinoma. Simple drainage by a percutaneously placed pig-tail catheter was insufficient because of inadequate removal of the contents of the abscess cavity. After dilatation of the drain tract the persistent semi-solid necrotic contents were fragmented by a pulsed lavage device, after which the abscess healed uneventfully. The application of pulsed lavage for debridement of drainage-resistant liver abscesses proved to be an effective and minimally invasive alternative to open surgery.</description><identifier>ISSN: 0007-1285</identifier><identifier>EISSN: 1748-880X</identifier><identifier>DOI: 10.1259/bjr/69471744</identifier><identifier>PMID: 20739342</identifier><language>eng</language><publisher>England: The British Institute of Radiology</publisher><subject>Aged ; Case Report ; Catheterization - instrumentation ; Catheterization - methods ; Drainage - instrumentation ; Drainage - methods ; Humans ; Liver Abscess - therapy ; Male ; Therapeutic Irrigation - instrumentation ; Therapeutic Irrigation - methods ; Tomography, X-Ray Computed ; Treatment Outcome</subject><ispartof>British journal of radiology, 2010-09, Vol.83 (993), p.e195-e197</ispartof><rights>2010 The British Institute of Radiology 2010</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c383t-a8d2e735baca92b89e4a8387a9e80f0b288545a4b45e395bef99c774d705c2c63</citedby><cites>FETCH-LOGICAL-c383t-a8d2e735baca92b89e4a8387a9e80f0b288545a4b45e395bef99c774d705c2c63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,777,781,882,27905,27906</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20739342$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>De Jong, K P</creatorcontrib><creatorcontrib>Prins, T R</creatorcontrib><creatorcontrib>Hofker, H S</creatorcontrib><title>A new interventional technique for percutaneous treatment of drainage-resistant liver abscess</title><title>British journal of radiology</title><addtitle>Br J Radiol</addtitle><description>The objective of this case report is to describe a device that can be used as a minimally invasive alternative for the treatment of drainage-resistant liver abscess. The device uses pulse lavage to fragment and evacuate the semi-solid contents of a liver abscess. The treatment of liver abscesses consists of percutaneous drainage, antibiotics and treatment of the underlying cause. This approach can be ineffective if the contents of the abscess cavity are not liquid, and in those cases open surgery is often needed. Here, we describe for the first time a new minimally invasive technique for treating persistent liver abscesses. A patient developed a liver abscess after a hepatico-jejunostomy performed as a palliative treatment for an unresectable pancreatic head carcinoma. Simple drainage by a percutaneously placed pig-tail catheter was insufficient because of inadequate removal of the contents of the abscess cavity. After dilatation of the drain tract the persistent semi-solid necrotic contents were fragmented by a pulsed lavage device, after which the abscess healed uneventfully. The application of pulsed lavage for debridement of drainage-resistant liver abscesses proved to be an effective and minimally invasive alternative to open surgery.</description><subject>Aged</subject><subject>Case Report</subject><subject>Catheterization - instrumentation</subject><subject>Catheterization - methods</subject><subject>Drainage - instrumentation</subject><subject>Drainage - methods</subject><subject>Humans</subject><subject>Liver Abscess - therapy</subject><subject>Male</subject><subject>Therapeutic Irrigation - instrumentation</subject><subject>Therapeutic Irrigation - methods</subject><subject>Tomography, X-Ray Computed</subject><subject>Treatment Outcome</subject><issn>0007-1285</issn><issn>1748-880X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpVkctLAzEQxoMoWh83z5KbF1ezeTTJRSjiCwQvCl4kZLOzbWQfNUkr_vem1BY9DcP8-Ga--RA6LcllSYW-qj7C1VhzWUrOd9AoF1UoRd520YgQIouSKnGADmP8WLVCk310QIlkmnE6Qu8T3MMX9n2CsIQ--aG3LU7gZr3_XABuhoDnENwi2R6GRcQpgE1dJvHQ4DpY39spFAGijxlJuPVLCNhW0UGMx2ivsW2Ek996hF7vbl9uHoqn5_vHm8lT4ZhiqbCqpiCZqKyzmlZKA7eKKWk1KNKQiioluLC84gKYFhU0WjspeS2JcNSN2RG6XuvOF1UHtcvnBduaefCdDd9msN78n_R-ZqbD0jAuGdMrgfNfgTBk2zGZzmcHbbt2bfJTtWZM0ExerEkXhhgDNNstJTGrQEwOxGwCyfjZ38u28CYB9gPAzIou</recordid><startdate>201009</startdate><enddate>201009</enddate><creator>De Jong, K P</creator><creator>Prins, T R</creator><creator>Hofker, H S</creator><general>The British Institute of Radiology</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>201009</creationdate><title>A new interventional technique for percutaneous treatment of drainage-resistant liver abscess</title><author>De Jong, K P ; Prins, T R ; Hofker, H S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c383t-a8d2e735baca92b89e4a8387a9e80f0b288545a4b45e395bef99c774d705c2c63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Aged</topic><topic>Case Report</topic><topic>Catheterization - instrumentation</topic><topic>Catheterization - methods</topic><topic>Drainage - instrumentation</topic><topic>Drainage - methods</topic><topic>Humans</topic><topic>Liver Abscess - therapy</topic><topic>Male</topic><topic>Therapeutic Irrigation - instrumentation</topic><topic>Therapeutic Irrigation - methods</topic><topic>Tomography, X-Ray Computed</topic><topic>Treatment Outcome</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>De Jong, K P</creatorcontrib><creatorcontrib>Prins, T R</creatorcontrib><creatorcontrib>Hofker, H S</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>British journal of radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>De Jong, K P</au><au>Prins, T R</au><au>Hofker, H S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A new interventional technique for percutaneous treatment of drainage-resistant liver abscess</atitle><jtitle>British journal of radiology</jtitle><addtitle>Br J Radiol</addtitle><date>2010-09</date><risdate>2010</risdate><volume>83</volume><issue>993</issue><spage>e195</spage><epage>e197</epage><pages>e195-e197</pages><issn>0007-1285</issn><eissn>1748-880X</eissn><abstract>The objective of this case report is to describe a device that can be used as a minimally invasive alternative for the treatment of drainage-resistant liver abscess. The device uses pulse lavage to fragment and evacuate the semi-solid contents of a liver abscess. The treatment of liver abscesses consists of percutaneous drainage, antibiotics and treatment of the underlying cause. This approach can be ineffective if the contents of the abscess cavity are not liquid, and in those cases open surgery is often needed. Here, we describe for the first time a new minimally invasive technique for treating persistent liver abscesses. A patient developed a liver abscess after a hepatico-jejunostomy performed as a palliative treatment for an unresectable pancreatic head carcinoma. Simple drainage by a percutaneously placed pig-tail catheter was insufficient because of inadequate removal of the contents of the abscess cavity. After dilatation of the drain tract the persistent semi-solid necrotic contents were fragmented by a pulsed lavage device, after which the abscess healed uneventfully. The application of pulsed lavage for debridement of drainage-resistant liver abscesses proved to be an effective and minimally invasive alternative to open surgery.</abstract><cop>England</cop><pub>The British Institute of Radiology</pub><pmid>20739342</pmid><doi>10.1259/bjr/69471744</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0007-1285
ispartof British journal of radiology, 2010-09, Vol.83 (993), p.e195-e197
issn 0007-1285
1748-880X
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3473396
source MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Oxford University Press Journals All Titles (1996-Current)
subjects Aged
Case Report
Catheterization - instrumentation
Catheterization - methods
Drainage - instrumentation
Drainage - methods
Humans
Liver Abscess - therapy
Male
Therapeutic Irrigation - instrumentation
Therapeutic Irrigation - methods
Tomography, X-Ray Computed
Treatment Outcome
title A new interventional technique for percutaneous treatment of drainage-resistant liver abscess
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-18T23%3A54%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20new%20interventional%20technique%20for%20percutaneous%20treatment%20of%20drainage-resistant%20liver%20abscess&rft.jtitle=British%20journal%20of%20radiology&rft.au=De%20Jong,%20K%20P&rft.date=2010-09&rft.volume=83&rft.issue=993&rft.spage=e195&rft.epage=e197&rft.pages=e195-e197&rft.issn=0007-1285&rft.eissn=1748-880X&rft_id=info:doi/10.1259/bjr/69471744&rft_dat=%3Cproquest_pubme%3E748993352%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=748993352&rft_id=info:pmid/20739342&rfr_iscdi=true