To assess if the uterine cavity depth measured by a blind pre-cycle mock transfer changes after gonadotropin stimulation. This is a retrospective cohort study at an academic IVF program involving 128 infertility patients. The main outcome measures were uterine cavity depth measured at the blind pre-...
Gespeichert in:
Veröffentlicht in: | Journal of assisted reproduction and genetics 2007-03, Vol.24 (2-3), p.77-82 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 82 |
---|---|
container_issue | 2-3 |
container_start_page | 77 |
container_title | Journal of assisted reproduction and genetics |
container_volume | 24 |
creator | Miller, Kristin L Frattarelli, John L |
description | To assess if the uterine cavity depth measured by a blind pre-cycle mock transfer changes after gonadotropin stimulation.
This is a retrospective cohort study at an academic IVF program involving 128 infertility patients. The main outcome measures were uterine cavity depth measured at the blind pre-stimulation mock transfer and the ultrasound-guided embryo transfer.
A >or= 1 cm increase in uterine cavity depth was found in 57.9% of the patients. The mean pre-cycle blind mock transfer uterine depth significantly differed from the mean uterine depth measured at embryo transfer. Based on the mock transfer, the anticipated embryo transfer depth was significantly less than the actual ultrasound-guided embryo transfer depth.
Uterine depth significantly differed between the blind pre-cycle mock transfer measurement and the ultrasound-guided embryo transfer measurement. The mock transfer may predict a difficult embryo transfer but it is an inaccurate predictor of the final embryo transfer depth. |
doi_str_mv | 10.1007/s10815-006-9098-1 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3454990</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>19706327</sourcerecordid><originalsourceid>FETCH-LOGICAL-c455t-8a1f8ac323031ac69e156baeb1278d81737c993601e07a2f386735bc202a72ee3</originalsourceid><addsrcrecordid>eNqFkUtv1TAQhS0Eou2FH8AGWSzYGcZx_NogoQooUiU2ZW05zoTrksTBTirdf4_LveK5YOWR55yjmfkIecbhFQfQrwsHwyUDUMyCNYw_IOdcasG0EPCw1iANg1aZM3JRyi1AFTXiMTnjuuFKKnFO9jd7pEtGFg5hRNqNce7plMJXilOXD4mu2c9lwExjoX6mcfYhbNmvP1x9DGvKNA21tcYQl_rf_-PscVn3T8ijwY8Fn57eHfn8_t3N5RW7_vTh4-XbaxZaKVdmPB-MD6IRILgPyiKXqvPY8Uab3nAtdLBWKOAI2jeDMEoL2YUGGq8bRLEjb465y9ZN2Aec6xyjW3KcfD645KP7szPHvfuS7pxoZWst1ICXp4Ccvm1YVjfFEnAc_YxpK06DaC209r9CbjUo0egqfPGX8DZtea5XcBWDAqErrx3hR1HIqZSMw8-RObh72u5I21Xa7p6249Xz_PddfzlOeMV3HT2mcg</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>216603773</pqid></control><display><type>article</type><title>The pre-cycle blind mock embryo transfer is an inaccurate predictor of anticipated embryo transfer depth</title><source>MEDLINE</source><source>PubMed Central</source><source>SpringerLink Journals - AutoHoldings</source><creator>Miller, Kristin L ; Frattarelli, John L</creator><creatorcontrib>Miller, Kristin L ; Frattarelli, John L</creatorcontrib><description>To assess if the uterine cavity depth measured by a blind pre-cycle mock transfer changes after gonadotropin stimulation.
This is a retrospective cohort study at an academic IVF program involving 128 infertility patients. The main outcome measures were uterine cavity depth measured at the blind pre-stimulation mock transfer and the ultrasound-guided embryo transfer.
A >or= 1 cm increase in uterine cavity depth was found in 57.9% of the patients. The mean pre-cycle blind mock transfer uterine depth significantly differed from the mean uterine depth measured at embryo transfer. Based on the mock transfer, the anticipated embryo transfer depth was significantly less than the actual ultrasound-guided embryo transfer depth.
Uterine depth significantly differed between the blind pre-cycle mock transfer measurement and the ultrasound-guided embryo transfer measurement. The mock transfer may predict a difficult embryo transfer but it is an inaccurate predictor of the final embryo transfer depth.</description><identifier>ISSN: 1058-0468</identifier><identifier>EISSN: 1573-7330</identifier><identifier>DOI: 10.1007/s10815-006-9098-1</identifier><identifier>PMID: 17216563</identifier><language>eng</language><publisher>Netherlands: Springer Nature B.V</publisher><subject>Assisted Reproduction ; Catheters ; Clinical trials ; Cohort Studies ; Drug dosages ; Embryo Implantation - physiology ; Embryo Transfer ; Embryo, Mammalian ; Embryos ; Female ; Fertilization in Vitro ; Follicles ; Humans ; In vitro fertilization ; Infertility ; Infertility, Female - etiology ; Infertility, Female - therapy ; Pregnancy ; Retrospective Studies ; Ultrasonic imaging ; Ultrasonography ; Uterus ; Uterus - anatomy & histology ; Uterus - diagnostic imaging</subject><ispartof>Journal of assisted reproduction and genetics, 2007-03, Vol.24 (2-3), p.77-82</ispartof><rights>Springer Science+Business Media, LLC 2007</rights><rights>Springer Science+Business Media, LLC 2006</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c455t-8a1f8ac323031ac69e156baeb1278d81737c993601e07a2f386735bc202a72ee3</citedby><cites>FETCH-LOGICAL-c455t-8a1f8ac323031ac69e156baeb1278d81737c993601e07a2f386735bc202a72ee3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3454990/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3454990/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17216563$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Miller, Kristin L</creatorcontrib><creatorcontrib>Frattarelli, John L</creatorcontrib><title>The pre-cycle blind mock embryo transfer is an inaccurate predictor of anticipated embryo transfer depth</title><title>Journal of assisted reproduction and genetics</title><addtitle>J Assist Reprod Genet</addtitle><description>To assess if the uterine cavity depth measured by a blind pre-cycle mock transfer changes after gonadotropin stimulation.
This is a retrospective cohort study at an academic IVF program involving 128 infertility patients. The main outcome measures were uterine cavity depth measured at the blind pre-stimulation mock transfer and the ultrasound-guided embryo transfer.
A >or= 1 cm increase in uterine cavity depth was found in 57.9% of the patients. The mean pre-cycle blind mock transfer uterine depth significantly differed from the mean uterine depth measured at embryo transfer. Based on the mock transfer, the anticipated embryo transfer depth was significantly less than the actual ultrasound-guided embryo transfer depth.
Uterine depth significantly differed between the blind pre-cycle mock transfer measurement and the ultrasound-guided embryo transfer measurement. The mock transfer may predict a difficult embryo transfer but it is an inaccurate predictor of the final embryo transfer depth.</description><subject>Assisted Reproduction</subject><subject>Catheters</subject><subject>Clinical trials</subject><subject>Cohort Studies</subject><subject>Drug dosages</subject><subject>Embryo Implantation - physiology</subject><subject>Embryo Transfer</subject><subject>Embryo, Mammalian</subject><subject>Embryos</subject><subject>Female</subject><subject>Fertilization in Vitro</subject><subject>Follicles</subject><subject>Humans</subject><subject>In vitro fertilization</subject><subject>Infertility</subject><subject>Infertility, Female - etiology</subject><subject>Infertility, Female - therapy</subject><subject>Pregnancy</subject><subject>Retrospective Studies</subject><subject>Ultrasonic imaging</subject><subject>Ultrasonography</subject><subject>Uterus</subject><subject>Uterus - anatomy & histology</subject><subject>Uterus - diagnostic imaging</subject><issn>1058-0468</issn><issn>1573-7330</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNqFkUtv1TAQhS0Eou2FH8AGWSzYGcZx_NogoQooUiU2ZW05zoTrksTBTirdf4_LveK5YOWR55yjmfkIecbhFQfQrwsHwyUDUMyCNYw_IOdcasG0EPCw1iANg1aZM3JRyi1AFTXiMTnjuuFKKnFO9jd7pEtGFg5hRNqNce7plMJXilOXD4mu2c9lwExjoX6mcfYhbNmvP1x9DGvKNA21tcYQl_rf_-PscVn3T8ijwY8Fn57eHfn8_t3N5RW7_vTh4-XbaxZaKVdmPB-MD6IRILgPyiKXqvPY8Uab3nAtdLBWKOAI2jeDMEoL2YUGGq8bRLEjb465y9ZN2Aec6xyjW3KcfD645KP7szPHvfuS7pxoZWst1ICXp4Ccvm1YVjfFEnAc_YxpK06DaC209r9CbjUo0egqfPGX8DZtea5XcBWDAqErrx3hR1HIqZSMw8-RObh72u5I21Xa7p6249Xz_PddfzlOeMV3HT2mcg</recordid><startdate>20070301</startdate><enddate>20070301</enddate><creator>Miller, Kristin L</creator><creator>Frattarelli, John L</creator><general>Springer Nature B.V</general><general>Kluwer Academic Publishers-Plenum Publishers</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8C1</scope><scope>8FD</scope><scope>8FE</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FR3</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>LK8</scope><scope>M0S</scope><scope>M1P</scope><scope>M7P</scope><scope>P64</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>RC3</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20070301</creationdate><title>The pre-cycle blind mock embryo transfer is an inaccurate predictor of anticipated embryo transfer depth</title><author>Miller, Kristin L ; Frattarelli, John L</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c455t-8a1f8ac323031ac69e156baeb1278d81737c993601e07a2f386735bc202a72ee3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Assisted Reproduction</topic><topic>Catheters</topic><topic>Clinical trials</topic><topic>Cohort Studies</topic><topic>Drug dosages</topic><topic>Embryo Implantation - physiology</topic><topic>Embryo Transfer</topic><topic>Embryo, Mammalian</topic><topic>Embryos</topic><topic>Female</topic><topic>Fertilization in Vitro</topic><topic>Follicles</topic><topic>Humans</topic><topic>In vitro fertilization</topic><topic>Infertility</topic><topic>Infertility, Female - etiology</topic><topic>Infertility, Female - therapy</topic><topic>Pregnancy</topic><topic>Retrospective Studies</topic><topic>Ultrasonic imaging</topic><topic>Ultrasonography</topic><topic>Uterus</topic><topic>Uterus - anatomy & histology</topic><topic>Uterus - diagnostic imaging</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Miller, Kristin L</creatorcontrib><creatorcontrib>Frattarelli, John L</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Public Health Database</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Engineering Research Database</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>ProQuest Biological Science Collection</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Biological Science Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Genetics Abstracts</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of assisted reproduction and genetics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Miller, Kristin L</au><au>Frattarelli, John L</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The pre-cycle blind mock embryo transfer is an inaccurate predictor of anticipated embryo transfer depth</atitle><jtitle>Journal of assisted reproduction and genetics</jtitle><addtitle>J Assist Reprod Genet</addtitle><date>2007-03-01</date><risdate>2007</risdate><volume>24</volume><issue>2-3</issue><spage>77</spage><epage>82</epage><pages>77-82</pages><issn>1058-0468</issn><eissn>1573-7330</eissn><abstract>To assess if the uterine cavity depth measured by a blind pre-cycle mock transfer changes after gonadotropin stimulation.
This is a retrospective cohort study at an academic IVF program involving 128 infertility patients. The main outcome measures were uterine cavity depth measured at the blind pre-stimulation mock transfer and the ultrasound-guided embryo transfer.
A >or= 1 cm increase in uterine cavity depth was found in 57.9% of the patients. The mean pre-cycle blind mock transfer uterine depth significantly differed from the mean uterine depth measured at embryo transfer. Based on the mock transfer, the anticipated embryo transfer depth was significantly less than the actual ultrasound-guided embryo transfer depth.
Uterine depth significantly differed between the blind pre-cycle mock transfer measurement and the ultrasound-guided embryo transfer measurement. The mock transfer may predict a difficult embryo transfer but it is an inaccurate predictor of the final embryo transfer depth.</abstract><cop>Netherlands</cop><pub>Springer Nature B.V</pub><pmid>17216563</pmid><doi>10.1007/s10815-006-9098-1</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1058-0468 |
ispartof | Journal of assisted reproduction and genetics, 2007-03, Vol.24 (2-3), p.77-82 |
issn | 1058-0468 1573-7330 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3454990 |
source | MEDLINE; PubMed Central; SpringerLink Journals - AutoHoldings |
subjects | Assisted Reproduction Catheters Clinical trials Cohort Studies Drug dosages Embryo Implantation - physiology Embryo Transfer Embryo, Mammalian Embryos Female Fertilization in Vitro Follicles Humans In vitro fertilization Infertility Infertility, Female - etiology Infertility, Female - therapy Pregnancy Retrospective Studies Ultrasonic imaging Ultrasonography Uterus Uterus - anatomy & histology Uterus - diagnostic imaging |
title | The pre-cycle blind mock embryo transfer is an inaccurate predictor of anticipated embryo transfer depth |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T06%3A25%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20pre-cycle%20blind%20mock%20embryo%20transfer%20is%20an%20inaccurate%20predictor%20of%20anticipated%20embryo%20transfer%20depth&rft.jtitle=Journal%20of%20assisted%20reproduction%20and%20genetics&rft.au=Miller,%20Kristin%20L&rft.date=2007-03-01&rft.volume=24&rft.issue=2-3&rft.spage=77&rft.epage=82&rft.pages=77-82&rft.issn=1058-0468&rft.eissn=1573-7330&rft_id=info:doi/10.1007/s10815-006-9098-1&rft_dat=%3Cproquest_pubme%3E19706327%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=216603773&rft_id=info:pmid/17216563&rfr_iscdi=true |