Proximal shunt dissection: a potential problem in carotid endarterectomy

The use of a shunt routinely, selectively, or not at all in performing carotid endarterectomy is a controversial and thus far unsettled dilemma. We have routinely used a shunt because it allows the operation to be done meticulously and without a sense of urgency. However, we recently encountered a c...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Texas Heart Institute journal 1985-12, Vol.12 (4), p.359-361
Hauptverfasser: CALHOUN, T. R, KITTEN, C. M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The use of a shunt routinely, selectively, or not at all in performing carotid endarterectomy is a controversial and thus far unsettled dilemma. We have routinely used a shunt because it allows the operation to be done meticulously and without a sense of urgency. However, we recently encountered a case in which proximal subintimal dissection occurred secondary to shunt insertion, which resulted in a postoperative neurologic deficit. We present the case, with a discussion of the probable cause of dissection and its future prevention.
ISSN:0730-2347
1526-6702