Comparative Evaluation of Two Types of Immediately Loaded Implants Using Biomechanical and Histomorphometric Tests : An Animal Case Study
Introduction. In order to minimize the required time to regain esthetic and function, immediately loaded implants were suggested. The aim of this study was to comparatively evaluate the Nisastan and XIve implants using biomechanical and histomorphometric tests. Materials and Methods. In this experim...
Gespeichert in:
Veröffentlicht in: | ISRN dentistry 2012, Vol.2012 (2012), p.1-6 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 6 |
---|---|
container_issue | 2012 |
container_start_page | 1 |
container_title | ISRN dentistry |
container_volume | 2012 |
creator | Rismanchian, Mansour Movahedian, Bijan Khalighinejad, Navid Badrian, Hamid Mohammad Razavi, Sayed Nekouie, Afsaneh |
description | Introduction. In order to minimize the required time to regain esthetic and function, immediately loaded implants were suggested. The aim of this study was to comparatively evaluate the Nisastan and XIve implants using biomechanical and histomorphometric tests. Materials and Methods. In this experimental study, 6 Nisastan one-piece immediately loaded screw type implant (OPILS) and 6 Xive implants with 3.4 mm diameter and 11 mm long were used. The implants were immediately loaded with temporary coating. After three months, the torque required to break bone-implant contact was measured and was recorded. All implants were extracted with surrounding bone and histologically were evaluated. The data were inputted into the SPSS 11.5 to run student T-test statistical analyses (α=0.05). Results. The success rates of both types of implants was 100%, and none of them failed due to mobility or bone loss. The mean removal torque value (RTV) was 142.08 and 40 N/Cm for Xive and Nisastan implants, respectively, and their RTVs showed a significant difference between two mentioned implants (P=0.004). None of the histomorphometric values showed significant differences between the two implants (P>0.05). Discussion. both systems have the capability to induce osseointegration under immediate loads but that Xive implants showed higher capability for bone contact. |
doi_str_mv | 10.5402/2012/328945 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3407639</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1034795226</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3495-683ed9b0e938cd547916479c403a34f7a0b38f044c0191657f29423bd4ada9e33</originalsourceid><addsrcrecordid>eNqFkc9vFCEUx4nR2Kb25FnD0disZYD5gQeTuqm2ySYe3CbeyFtgupgZGGFmm_0T_K_7NlM3epIQePD95Mt7PEJeF-xDKRm_5Kzgl4I3SpbPyClnii2kaH48P8Z1cULOc_7JcEikmuYlOeG8KVEvTsnvZewHSDD6naPXO-gmDGOgsaXrh0jX-8Hlw-G27531MLpuT1cRrLN4NXQQxkzvsg_39LOPvTNbCN5ARyFYeuPzGPuYhi0qY_KGrl1G_iO9Cjh9j9wSsqPfx8nuX5EXLXTZnT_tZ-Tuy_V6ebNYfft6u7xaLYyQqlxUjXBWbZhTojG2lLUqKlyMZAKEbGtgG9G0TErDCpTKuuVKcrGxEiwoJ8QZ-TT7DtMGazIujAk6PSTMJ-11BK__VYLf6vu400KyuhIKDd49GaT4a8KKdO-zcR1-hotT1gUTmFDJeYXoxYyaFHNOrj0-UzB96J8-9E_P_UP67d-ZHdk_3ULg_QxsfbDw4P_j9maGHSKuhSMssYhKikevtq04</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1034795226</pqid></control><display><type>article</type><title>Comparative Evaluation of Two Types of Immediately Loaded Implants Using Biomechanical and Histomorphometric Tests : An Animal Case Study</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central Open Access</source><source>PubMed Central</source><creator>Rismanchian, Mansour ; Movahedian, Bijan ; Khalighinejad, Navid ; Badrian, Hamid ; Mohammad Razavi, Sayed ; Nekouie, Afsaneh</creator><contributor>Liu, Z.-J. ; Lewinstein, I.</contributor><creatorcontrib>Rismanchian, Mansour ; Movahedian, Bijan ; Khalighinejad, Navid ; Badrian, Hamid ; Mohammad Razavi, Sayed ; Nekouie, Afsaneh ; Liu, Z.-J. ; Lewinstein, I.</creatorcontrib><description>Introduction. In order to minimize the required time to regain esthetic and function, immediately loaded implants were suggested. The aim of this study was to comparatively evaluate the Nisastan and XIve implants using biomechanical and histomorphometric tests. Materials and Methods. In this experimental study, 6 Nisastan one-piece immediately loaded screw type implant (OPILS) and 6 Xive implants with 3.4 mm diameter and 11 mm long were used. The implants were immediately loaded with temporary coating. After three months, the torque required to break bone-implant contact was measured and was recorded. All implants were extracted with surrounding bone and histologically were evaluated. The data were inputted into the SPSS 11.5 to run student T-test statistical analyses (α=0.05). Results. The success rates of both types of implants was 100%, and none of them failed due to mobility or bone loss. The mean removal torque value (RTV) was 142.08 and 40 N/Cm for Xive and Nisastan implants, respectively, and their RTVs showed a significant difference between two mentioned implants (P=0.004). None of the histomorphometric values showed significant differences between the two implants (P>0.05). Discussion. both systems have the capability to induce osseointegration under immediate loads but that Xive implants showed higher capability for bone contact.</description><identifier>ISSN: 2090-4371</identifier><identifier>ISSN: 2090-438X</identifier><identifier>EISSN: 2090-438X</identifier><identifier>DOI: 10.5402/2012/328945</identifier><identifier>PMID: 22852091</identifier><language>eng</language><publisher>Cairo, Egypt: Hindawi Puplishing Corporation</publisher><ispartof>ISRN dentistry, 2012, Vol.2012 (2012), p.1-6</ispartof><rights>Copyright © 2012 Mansour Rismanchian et al.</rights><rights>Copyright © 2012 Mansour Rismanchian et al. 2012</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3495-683ed9b0e938cd547916479c403a34f7a0b38f044c0191657f29423bd4ada9e33</citedby><cites>FETCH-LOGICAL-c3495-683ed9b0e938cd547916479c403a34f7a0b38f044c0191657f29423bd4ada9e33</cites><orcidid>0000-0003-2911-9606</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3407639/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3407639/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,725,778,782,883,4012,27910,27911,27912,53778,53780</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/22852091$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><contributor>Liu, Z.-J.</contributor><contributor>Lewinstein, I.</contributor><creatorcontrib>Rismanchian, Mansour</creatorcontrib><creatorcontrib>Movahedian, Bijan</creatorcontrib><creatorcontrib>Khalighinejad, Navid</creatorcontrib><creatorcontrib>Badrian, Hamid</creatorcontrib><creatorcontrib>Mohammad Razavi, Sayed</creatorcontrib><creatorcontrib>Nekouie, Afsaneh</creatorcontrib><title>Comparative Evaluation of Two Types of Immediately Loaded Implants Using Biomechanical and Histomorphometric Tests : An Animal Case Study</title><title>ISRN dentistry</title><addtitle>ISRN Dent</addtitle><description>Introduction. In order to minimize the required time to regain esthetic and function, immediately loaded implants were suggested. The aim of this study was to comparatively evaluate the Nisastan and XIve implants using biomechanical and histomorphometric tests. Materials and Methods. In this experimental study, 6 Nisastan one-piece immediately loaded screw type implant (OPILS) and 6 Xive implants with 3.4 mm diameter and 11 mm long were used. The implants were immediately loaded with temporary coating. After three months, the torque required to break bone-implant contact was measured and was recorded. All implants were extracted with surrounding bone and histologically were evaluated. The data were inputted into the SPSS 11.5 to run student T-test statistical analyses (α=0.05). Results. The success rates of both types of implants was 100%, and none of them failed due to mobility or bone loss. The mean removal torque value (RTV) was 142.08 and 40 N/Cm for Xive and Nisastan implants, respectively, and their RTVs showed a significant difference between two mentioned implants (P=0.004). None of the histomorphometric values showed significant differences between the two implants (P>0.05). Discussion. both systems have the capability to induce osseointegration under immediate loads but that Xive implants showed higher capability for bone contact.</description><issn>2090-4371</issn><issn>2090-438X</issn><issn>2090-438X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><sourceid>RHX</sourceid><recordid>eNqFkc9vFCEUx4nR2Kb25FnD0disZYD5gQeTuqm2ySYe3CbeyFtgupgZGGFmm_0T_K_7NlM3epIQePD95Mt7PEJeF-xDKRm_5Kzgl4I3SpbPyClnii2kaH48P8Z1cULOc_7JcEikmuYlOeG8KVEvTsnvZewHSDD6naPXO-gmDGOgsaXrh0jX-8Hlw-G27531MLpuT1cRrLN4NXQQxkzvsg_39LOPvTNbCN5ARyFYeuPzGPuYhi0qY_KGrl1G_iO9Cjh9j9wSsqPfx8nuX5EXLXTZnT_tZ-Tuy_V6ebNYfft6u7xaLYyQqlxUjXBWbZhTojG2lLUqKlyMZAKEbGtgG9G0TErDCpTKuuVKcrGxEiwoJ8QZ-TT7DtMGazIujAk6PSTMJ-11BK__VYLf6vu400KyuhIKDd49GaT4a8KKdO-zcR1-hotT1gUTmFDJeYXoxYyaFHNOrj0-UzB96J8-9E_P_UP67d-ZHdk_3ULg_QxsfbDw4P_j9maGHSKuhSMssYhKikevtq04</recordid><startdate>2012</startdate><enddate>2012</enddate><creator>Rismanchian, Mansour</creator><creator>Movahedian, Bijan</creator><creator>Khalighinejad, Navid</creator><creator>Badrian, Hamid</creator><creator>Mohammad Razavi, Sayed</creator><creator>Nekouie, Afsaneh</creator><general>Hindawi Puplishing Corporation</general><general>International Scholarly Research Network</general><scope>ADJCN</scope><scope>AHFXO</scope><scope>RHU</scope><scope>RHW</scope><scope>RHX</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0003-2911-9606</orcidid></search><sort><creationdate>2012</creationdate><title>Comparative Evaluation of Two Types of Immediately Loaded Implants Using Biomechanical and Histomorphometric Tests : An Animal Case Study</title><author>Rismanchian, Mansour ; Movahedian, Bijan ; Khalighinejad, Navid ; Badrian, Hamid ; Mohammad Razavi, Sayed ; Nekouie, Afsaneh</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3495-683ed9b0e938cd547916479c403a34f7a0b38f044c0191657f29423bd4ada9e33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Rismanchian, Mansour</creatorcontrib><creatorcontrib>Movahedian, Bijan</creatorcontrib><creatorcontrib>Khalighinejad, Navid</creatorcontrib><creatorcontrib>Badrian, Hamid</creatorcontrib><creatorcontrib>Mohammad Razavi, Sayed</creatorcontrib><creatorcontrib>Nekouie, Afsaneh</creatorcontrib><collection>الدوريات العلمية والإحصائية - e-Marefa Academic and Statistical Periodicals</collection><collection>معرفة - المحتوى العربي الأكاديمي المتكامل - e-Marefa Academic Complete</collection><collection>Hindawi Publishing Complete</collection><collection>Hindawi Publishing Subscription Journals</collection><collection>Hindawi Publishing Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>ISRN dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Rismanchian, Mansour</au><au>Movahedian, Bijan</au><au>Khalighinejad, Navid</au><au>Badrian, Hamid</au><au>Mohammad Razavi, Sayed</au><au>Nekouie, Afsaneh</au><au>Liu, Z.-J.</au><au>Lewinstein, I.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparative Evaluation of Two Types of Immediately Loaded Implants Using Biomechanical and Histomorphometric Tests : An Animal Case Study</atitle><jtitle>ISRN dentistry</jtitle><addtitle>ISRN Dent</addtitle><date>2012</date><risdate>2012</risdate><volume>2012</volume><issue>2012</issue><spage>1</spage><epage>6</epage><pages>1-6</pages><issn>2090-4371</issn><issn>2090-438X</issn><eissn>2090-438X</eissn><abstract>Introduction. In order to minimize the required time to regain esthetic and function, immediately loaded implants were suggested. The aim of this study was to comparatively evaluate the Nisastan and XIve implants using biomechanical and histomorphometric tests. Materials and Methods. In this experimental study, 6 Nisastan one-piece immediately loaded screw type implant (OPILS) and 6 Xive implants with 3.4 mm diameter and 11 mm long were used. The implants were immediately loaded with temporary coating. After three months, the torque required to break bone-implant contact was measured and was recorded. All implants were extracted with surrounding bone and histologically were evaluated. The data were inputted into the SPSS 11.5 to run student T-test statistical analyses (α=0.05). Results. The success rates of both types of implants was 100%, and none of them failed due to mobility or bone loss. The mean removal torque value (RTV) was 142.08 and 40 N/Cm for Xive and Nisastan implants, respectively, and their RTVs showed a significant difference between two mentioned implants (P=0.004). None of the histomorphometric values showed significant differences between the two implants (P>0.05). Discussion. both systems have the capability to induce osseointegration under immediate loads but that Xive implants showed higher capability for bone contact.</abstract><cop>Cairo, Egypt</cop><pub>Hindawi Puplishing Corporation</pub><pmid>22852091</pmid><doi>10.5402/2012/328945</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0003-2911-9606</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2090-4371 |
ispartof | ISRN dentistry, 2012, Vol.2012 (2012), p.1-6 |
issn | 2090-4371 2090-438X 2090-438X |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3407639 |
source | Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central Open Access; PubMed Central |
title | Comparative Evaluation of Two Types of Immediately Loaded Implants Using Biomechanical and Histomorphometric Tests : An Animal Case Study |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T17%3A58%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparative%20Evaluation%20of%20Two%20Types%20of%20Immediately%20Loaded%20Implants%20Using%20Biomechanical%20and%20Histomorphometric%20Tests%20:%20An%20Animal%20Case%20Study&rft.jtitle=ISRN%20dentistry&rft.au=Rismanchian,%20Mansour&rft.date=2012&rft.volume=2012&rft.issue=2012&rft.spage=1&rft.epage=6&rft.pages=1-6&rft.issn=2090-4371&rft.eissn=2090-438X&rft_id=info:doi/10.5402/2012/328945&rft_dat=%3Cproquest_pubme%3E1034795226%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1034795226&rft_id=info:pmid/22852091&rfr_iscdi=true |