Dynamically applied B1+ shimming solutions for non-contrast enhanced renal angiography at 7.0 tesla

The purpose of this study was to detail a strategy for performing non‐contrast enhanced renal magnetic resonance angiography studies at 7.0 T. It is demonstrated that with proper B 1+ management, these studies can be successfully performed at ultrahigh field within local specific absorption rate con...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Magnetic resonance in medicine 2013-01, Vol.69 (1), p.114-126
Hauptverfasser: Metzger, Gregory J., Auerbach, Edward J., Akgun, Can, Simonson, Josh, Bi, Xiaoming, Uğurbil, Kâmil, van de Moortele, Pierre-François
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 126
container_issue 1
container_start_page 114
container_title Magnetic resonance in medicine
container_volume 69
creator Metzger, Gregory J.
Auerbach, Edward J.
Akgun, Can
Simonson, Josh
Bi, Xiaoming
Uğurbil, Kâmil
van de Moortele, Pierre-François
description The purpose of this study was to detail a strategy for performing non‐contrast enhanced renal magnetic resonance angiography studies at 7.0 T. It is demonstrated that with proper B 1+ management, these studies can be successfully performed at ultrahigh field within local specific absorption rate constraints. An inversion prepared gradient echo acquisition, standard for non‐contrast renal magnetic resonance angiography studies, required radiofrequency pulse specific B 1+ shimming solutions to be dynamically applied to address the field dependent increases in both B0 and B 1+ inhomogeneity as well as to accommodate limitation in available power. By using more efficient B 1+ shimming solutions for the inversion preparation and more homogeneous solutions for the excitation, high quality images of the renal arteries were obtained without venous and background signal artifacts while working within hardware and safety constraints. Finite difference time domain simulations confirmed in vivo measurements with respect to B 1+ distributions and homogeneity for the range of shimming strategies used and allowed the calculation of peak local specific absorption rate values normalized by input power and B 1+. Increasing B 1+ homogeneity was accompanied by decreasing local specific absorption rate per Watt and increasing maximum local specific absorption rate per [B 1+]2, which must be considered, along with body size and respiratory rate, when finalizing acquisition parameters for a given individual. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.
doi_str_mv 10.1002/mrm.24237
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3387512</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1273276247</sourcerecordid><originalsourceid>FETCH-LOGICAL-i3227-c62f2cd88951933d3926dae0b918551f1c09a67bfaaa798d43492bf5476d7b543</originalsourceid><addsrcrecordid>eNpdkV9rFDEUxYModlt98AtIwBdBZpvcJJPNi2C7tQpbRal_8CVkZjK7aTPJOJlR99ubduuiPt0L93cOh3sQekLJnBICx93QzYEDk_fQjAqAAoTi99GMSE4KRhU_QIcpXRFClJL8IToA4ByIKGeoXm6D6VxtvN9i0_fe2Qaf0Bc4bVzXubDGKfppdDEk3MYBhxiKOoZxMGnENmxMqLNgsMF4bMLaxfVg-k22GrGcEzza5M0j9KA1PtnHd_MIfXp9dnn6pli9P397-mpVOAYgi7qEFupmsVCCKsYapqBsjCWVogshaEtrokwpq9YYI9Wi4YwrqFrBZdnISnB2hF7ufPup6mxT25uYXveD68yw1dE4_e8luI1exx-asYUUFLLB8zuDIX6fbBp151JtvTfBxilpCpKBLIHLjD77D72K05C_kCkmGOElEJqpp38n2kf58_8MHO-An87b7f5Oib4pVudi9W2x-uLjxe2SFcVO4dJof-0VZrjWpWRS6C_vzvXJh8_fvl4uV3rJfgMYqaS_</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1353046201</pqid></control><display><type>article</type><title>Dynamically applied B1+ shimming solutions for non-contrast enhanced renal angiography at 7.0 tesla</title><source>MEDLINE</source><source>Wiley Free Content</source><source>Wiley Online Library All Journals</source><creator>Metzger, Gregory J. ; Auerbach, Edward J. ; Akgun, Can ; Simonson, Josh ; Bi, Xiaoming ; Uğurbil, Kâmil ; van de Moortele, Pierre-François</creator><creatorcontrib>Metzger, Gregory J. ; Auerbach, Edward J. ; Akgun, Can ; Simonson, Josh ; Bi, Xiaoming ; Uğurbil, Kâmil ; van de Moortele, Pierre-François</creatorcontrib><description>The purpose of this study was to detail a strategy for performing non‐contrast enhanced renal magnetic resonance angiography studies at 7.0 T. It is demonstrated that with proper B 1+ management, these studies can be successfully performed at ultrahigh field within local specific absorption rate constraints. An inversion prepared gradient echo acquisition, standard for non‐contrast renal magnetic resonance angiography studies, required radiofrequency pulse specific B 1+ shimming solutions to be dynamically applied to address the field dependent increases in both B0 and B 1+ inhomogeneity as well as to accommodate limitation in available power. By using more efficient B 1+ shimming solutions for the inversion preparation and more homogeneous solutions for the excitation, high quality images of the renal arteries were obtained without venous and background signal artifacts while working within hardware and safety constraints. Finite difference time domain simulations confirmed in vivo measurements with respect to B 1+ distributions and homogeneity for the range of shimming strategies used and allowed the calculation of peak local specific absorption rate values normalized by input power and B 1+. Increasing B 1+ homogeneity was accompanied by decreasing local specific absorption rate per Watt and increasing maximum local specific absorption rate per [B 1+]2, which must be considered, along with body size and respiratory rate, when finalizing acquisition parameters for a given individual. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.</description><identifier>ISSN: 0740-3194</identifier><identifier>EISSN: 1522-2594</identifier><identifier>DOI: 10.1002/mrm.24237</identifier><identifier>PMID: 22442056</identifier><identifier>CODEN: MRMEEN</identifier><language>eng</language><publisher>Hoboken: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>7 T ; B 1+ shimming ; Humans ; Image Enhancement ; kidney ; Magnetic Resonance Angiography - methods ; non-contrast enhanced ; renal angiography ; Renal Artery - anatomy &amp; histology</subject><ispartof>Magnetic resonance in medicine, 2013-01, Vol.69 (1), p.114-126</ispartof><rights>Copyright © 2012 Wiley Periodicals, Inc.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fmrm.24237$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fmrm.24237$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>230,314,780,784,885,1416,1432,27923,27924,45573,45574,46408,46832</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/22442056$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Metzger, Gregory J.</creatorcontrib><creatorcontrib>Auerbach, Edward J.</creatorcontrib><creatorcontrib>Akgun, Can</creatorcontrib><creatorcontrib>Simonson, Josh</creatorcontrib><creatorcontrib>Bi, Xiaoming</creatorcontrib><creatorcontrib>Uğurbil, Kâmil</creatorcontrib><creatorcontrib>van de Moortele, Pierre-François</creatorcontrib><title>Dynamically applied B1+ shimming solutions for non-contrast enhanced renal angiography at 7.0 tesla</title><title>Magnetic resonance in medicine</title><addtitle>Magn Reson Med</addtitle><description>The purpose of this study was to detail a strategy for performing non‐contrast enhanced renal magnetic resonance angiography studies at 7.0 T. It is demonstrated that with proper B 1+ management, these studies can be successfully performed at ultrahigh field within local specific absorption rate constraints. An inversion prepared gradient echo acquisition, standard for non‐contrast renal magnetic resonance angiography studies, required radiofrequency pulse specific B 1+ shimming solutions to be dynamically applied to address the field dependent increases in both B0 and B 1+ inhomogeneity as well as to accommodate limitation in available power. By using more efficient B 1+ shimming solutions for the inversion preparation and more homogeneous solutions for the excitation, high quality images of the renal arteries were obtained without venous and background signal artifacts while working within hardware and safety constraints. Finite difference time domain simulations confirmed in vivo measurements with respect to B 1+ distributions and homogeneity for the range of shimming strategies used and allowed the calculation of peak local specific absorption rate values normalized by input power and B 1+. Increasing B 1+ homogeneity was accompanied by decreasing local specific absorption rate per Watt and increasing maximum local specific absorption rate per [B 1+]2, which must be considered, along with body size and respiratory rate, when finalizing acquisition parameters for a given individual. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.</description><subject>7 T</subject><subject>B 1+ shimming</subject><subject>Humans</subject><subject>Image Enhancement</subject><subject>kidney</subject><subject>Magnetic Resonance Angiography - methods</subject><subject>non-contrast enhanced</subject><subject>renal angiography</subject><subject>Renal Artery - anatomy &amp; histology</subject><issn>0740-3194</issn><issn>1522-2594</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpdkV9rFDEUxYModlt98AtIwBdBZpvcJJPNi2C7tQpbRal_8CVkZjK7aTPJOJlR99ubduuiPt0L93cOh3sQekLJnBICx93QzYEDk_fQjAqAAoTi99GMSE4KRhU_QIcpXRFClJL8IToA4ByIKGeoXm6D6VxtvN9i0_fe2Qaf0Bc4bVzXubDGKfppdDEk3MYBhxiKOoZxMGnENmxMqLNgsMF4bMLaxfVg-k22GrGcEzza5M0j9KA1PtnHd_MIfXp9dnn6pli9P397-mpVOAYgi7qEFupmsVCCKsYapqBsjCWVogshaEtrokwpq9YYI9Wi4YwrqFrBZdnISnB2hF7ufPup6mxT25uYXveD68yw1dE4_e8luI1exx-asYUUFLLB8zuDIX6fbBp151JtvTfBxilpCpKBLIHLjD77D72K05C_kCkmGOElEJqpp38n2kf58_8MHO-An87b7f5Oib4pVudi9W2x-uLjxe2SFcVO4dJof-0VZrjWpWRS6C_vzvXJh8_fvl4uV3rJfgMYqaS_</recordid><startdate>201301</startdate><enddate>201301</enddate><creator>Metzger, Gregory J.</creator><creator>Auerbach, Edward J.</creator><creator>Akgun, Can</creator><creator>Simonson, Josh</creator><creator>Bi, Xiaoming</creator><creator>Uğurbil, Kâmil</creator><creator>van de Moortele, Pierre-François</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><general>Wiley Subscription Services, Inc</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>8FD</scope><scope>FR3</scope><scope>K9.</scope><scope>M7Z</scope><scope>P64</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>201301</creationdate><title>Dynamically applied B1+ shimming solutions for non-contrast enhanced renal angiography at 7.0 tesla</title><author>Metzger, Gregory J. ; Auerbach, Edward J. ; Akgun, Can ; Simonson, Josh ; Bi, Xiaoming ; Uğurbil, Kâmil ; van de Moortele, Pierre-François</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i3227-c62f2cd88951933d3926dae0b918551f1c09a67bfaaa798d43492bf5476d7b543</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>7 T</topic><topic>B 1+ shimming</topic><topic>Humans</topic><topic>Image Enhancement</topic><topic>kidney</topic><topic>Magnetic Resonance Angiography - methods</topic><topic>non-contrast enhanced</topic><topic>renal angiography</topic><topic>Renal Artery - anatomy &amp; histology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Metzger, Gregory J.</creatorcontrib><creatorcontrib>Auerbach, Edward J.</creatorcontrib><creatorcontrib>Akgun, Can</creatorcontrib><creatorcontrib>Simonson, Josh</creatorcontrib><creatorcontrib>Bi, Xiaoming</creatorcontrib><creatorcontrib>Uğurbil, Kâmil</creatorcontrib><creatorcontrib>van de Moortele, Pierre-François</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Biochemistry Abstracts 1</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Magnetic resonance in medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Metzger, Gregory J.</au><au>Auerbach, Edward J.</au><au>Akgun, Can</au><au>Simonson, Josh</au><au>Bi, Xiaoming</au><au>Uğurbil, Kâmil</au><au>van de Moortele, Pierre-François</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Dynamically applied B1+ shimming solutions for non-contrast enhanced renal angiography at 7.0 tesla</atitle><jtitle>Magnetic resonance in medicine</jtitle><addtitle>Magn Reson Med</addtitle><date>2013-01</date><risdate>2013</risdate><volume>69</volume><issue>1</issue><spage>114</spage><epage>126</epage><pages>114-126</pages><issn>0740-3194</issn><eissn>1522-2594</eissn><coden>MRMEEN</coden><abstract>The purpose of this study was to detail a strategy for performing non‐contrast enhanced renal magnetic resonance angiography studies at 7.0 T. It is demonstrated that with proper B 1+ management, these studies can be successfully performed at ultrahigh field within local specific absorption rate constraints. An inversion prepared gradient echo acquisition, standard for non‐contrast renal magnetic resonance angiography studies, required radiofrequency pulse specific B 1+ shimming solutions to be dynamically applied to address the field dependent increases in both B0 and B 1+ inhomogeneity as well as to accommodate limitation in available power. By using more efficient B 1+ shimming solutions for the inversion preparation and more homogeneous solutions for the excitation, high quality images of the renal arteries were obtained without venous and background signal artifacts while working within hardware and safety constraints. Finite difference time domain simulations confirmed in vivo measurements with respect to B 1+ distributions and homogeneity for the range of shimming strategies used and allowed the calculation of peak local specific absorption rate values normalized by input power and B 1+. Increasing B 1+ homogeneity was accompanied by decreasing local specific absorption rate per Watt and increasing maximum local specific absorption rate per [B 1+]2, which must be considered, along with body size and respiratory rate, when finalizing acquisition parameters for a given individual. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.</abstract><cop>Hoboken</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><pmid>22442056</pmid><doi>10.1002/mrm.24237</doi><tpages>13</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0740-3194
ispartof Magnetic resonance in medicine, 2013-01, Vol.69 (1), p.114-126
issn 0740-3194
1522-2594
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3387512
source MEDLINE; Wiley Free Content; Wiley Online Library All Journals
subjects 7 T
B 1+ shimming
Humans
Image Enhancement
kidney
Magnetic Resonance Angiography - methods
non-contrast enhanced
renal angiography
Renal Artery - anatomy & histology
title Dynamically applied B1+ shimming solutions for non-contrast enhanced renal angiography at 7.0 tesla
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-12T20%3A08%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Dynamically%20applied%20B1+%20shimming%20solutions%20for%20non-contrast%20enhanced%20renal%20angiography%20at%207.0%20tesla&rft.jtitle=Magnetic%20resonance%20in%20medicine&rft.au=Metzger,%20Gregory%20J.&rft.date=2013-01&rft.volume=69&rft.issue=1&rft.spage=114&rft.epage=126&rft.pages=114-126&rft.issn=0740-3194&rft.eissn=1522-2594&rft.coden=MRMEEN&rft_id=info:doi/10.1002/mrm.24237&rft_dat=%3Cproquest_pubme%3E1273276247%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1353046201&rft_id=info:pmid/22442056&rfr_iscdi=true