Detection of atrial high-rate events by continuous Home Monitoring: clinical significance in the heart failure-cardiac resynchronization therapy population

Aims Uncertainty exists over the importance of device-detected short-duration atrial arrhythmias. Continuous atrial diagnostics, through home monitoring (HM) technology (BIOTRONIK, Berlin, Germany), provides a unique opportunity to assess frequency and quantity of atrial fibrillation (AF) episodes d...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Europace (London, England) England), 2012-02, Vol.14 (2), p.230-237
Hauptverfasser: Shanmugam, Nesan, Boerdlein, Annegret, Proff, Jochen, Ong, Peter, Valencia, Oswaldo, Maier, Sebastian K.G., Bauer, Wolfgang R., Paul, Vince, Sack, Stefan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Aims Uncertainty exists over the importance of device-detected short-duration atrial arrhythmias. Continuous atrial diagnostics, through home monitoring (HM) technology (BIOTRONIK, Berlin, Germany), provides a unique opportunity to assess frequency and quantity of atrial fibrillation (AF) episodes defined as atrial high-rate events (AHRE). Methods and results Prospective data from 560 heart failure (HF) patients (age 67 ± 10 years, median ejection fraction 27%) patients with a cardiac resynchronization therapy (CRT) device capable of HM from two multi-centre studies were analysed. Atrial high-rate events burden was defined as the duration of mode switch in a 24-h period with atrial rates of >180 beats for at least 1% or total of 14 min per day. The primary endpoint was incidence of a thromboembolic (TE) event. Secondary endpoints were cardiovascular death, hospitalization because of AF, or worsening HF. Over a median 370-day follow-up AHRE occurred in 40% of patients with 11 (2%) patients developing TE complications and mortality rate of 4.3% (24 deaths, 16 with cardiovascular aetiology). Compared with patients without detected AHRE, patients with detected AHRE>3.8 h over a day were nine times more likely to develop TE complications (P= 0.006). The majority of patients (73%) did not show a temporal association with the detected atrial episode and their adverse event, with a mean interval of 46.7 ± 71.9 days (range 0-194) before the TE complication. Conclusion In a high-risk cohort of HF patients, device-detected atrial arrhythmias are associated with an increased incidence of TE events. A cut-off point of 3.8 h over 24 h was associated with significant increase in the event rate. Routine assessment of AHRE should be considered with other data when assessing stroke risk and considering anti-coagulation initiation and should also prompt the optimization of cardioprotective HF therapy in CRT patients.
ISSN:1099-5129
1532-2092
DOI:10.1093/europace/eur293