Brachial artery diameter, blood flow and flow-mediated dilation in sleep-disordered breathing
Abstract Clinic-based, case-control studies linked sleep-disordered breathing (SDB) to markers of endothelial dysfunction. We attempted to validate this association in a large community-based sample, and evaluate the relation of SDB to arterial diameter and peripheral blood flow. This community-base...
Gespeichert in:
Veröffentlicht in: | Vascular medicine (London, England) England), 2009-11, Vol.14 (4), p.351-360 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract
Clinic-based, case-control studies linked sleep-disordered breathing (SDB) to markers of endothelial dysfunction. We attempted to validate this association in a large community-based sample, and evaluate the relation of SDB to arterial diameter and peripheral blood flow. This community-based, cross-sectional observational study included 327 men and 355 women, aged 42–83 years, from the Framingham Heart Study site of the Sleep Heart Health Study. The polysomnographically derived apnea-hypopnea index and the hypoxemia index (percent sleep time with oxyhemoglobin saturation below 90%) were used to quantify the severity of SDB. Brachial artery ultrasound measurements included baseline diameter, percent flow-mediated dilation, and baseline and hyperemic flow velocity and volume. The baseline brachial artery diameter was significantly associated with both the apnea-hypopnea index and the hypoxemia index. The association was diminished by adjustment for body mass index, but remained significant for the apnea-hypopnea index. Age-, sex-, race- and body mass index-adjusted mean diameters were 4.32, 4.33, 4.33, 4.56, 4.53 mm for those with apnea-hypopnea index < 1.5, 1.5–4.9, 5–14.9, 15–29.9, ≥ 30, respectively; p = 0.03. Baseline flow measures were associated with the apnea-hypopnea index but this association was non-significant after adjusting for body mass index. No significant association was observed between measures of SDB and percent flow-mediated dilation or hyperemic flow in any model. In conclusion, this study supports a moderate association of SDB and larger baseline brachial artery diameter, which may reflect SDB-induced vascular remodeling. This study does not support a link between SDB and endothelial dysfunction as measured by brachial artery flow-mediated dilation. |
---|---|
ISSN: | 1358-863X 1477-0377 |