Protective isolation in a burns unit: the use of plastic isolators and air curtains

The use of plastic isolators and of an ‘air curtain’ isolator for protection of patients against infection was studied in a burns unit. Preliminary bacteriological tests showed that very few airborne bacteria gained access to a plastic ventilated isolator; even when the filter and pre-filter were re...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Epidemiology and infection 1971-12, Vol.69 (4), p.529-546
Hauptverfasser: Lowbury, E. J. L., Babb, J. R., Ford, Pamela M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 546
container_issue 4
container_start_page 529
container_title Epidemiology and infection
container_volume 69
creator Lowbury, E. J. L.
Babb, J. R.
Ford, Pamela M.
description The use of plastic isolators and of an ‘air curtain’ isolator for protection of patients against infection was studied in a burns unit. Preliminary bacteriological tests showed that very few airborne bacteria gained access to a plastic ventilated isolator; even when the filter and pre-filter were removed from the air inflow, settle-plate counts inside the isolator were much lower than those in the open ward, but the difference was smaller in tests made with an Anderson air sampler, which showed also that fewer large bacteria-carrying particles appeared inside the isolator than outside it. An open-topped isolator allowed virtually free access of bacteria from ambient air. The numbers of airborne bacteria inside an air curtain were appreciably lower than the counts of airborne bacteria in the open ward, but not as low as those in the plastic ventilated isolator. Controlled trials of isolators were made on patients with fresh burns of 4–30 % of the body surface; the patients were given no topical chemoprophylaxis against Staphylococcus aureus or Gram-negative bacilli. Patients treated in plastic isolators showed a significantly lower incidence of infection with Pseudomonas aeruginosa than those treated in the open ward; this protective effect was shown by isolators with or without filters or with an open top. Ventilated isolators, which protected patients against personal contact and airborne infection, gave a limited protection against multi-resistant ‘hospital’ strains of Staph. aureus, but no such protection was given by an open-topped isolator, which protected only against personal contact infection, or by air curtains, which protected only against airborne infection; the air curtain gave no protection against Ps. aeruginosa, and there was no evidence of protection by any isolator against Proteus spp. and coliform bacilli. Both the controlled trials and evidence from the bacteriology of air, hands, fomites and rectal and nasal swabs taken on admission and later, supported the view that Ps. aeruginosa is transferred mainly by personal contact, Staph. aureus probably by air as well as by contact and coliform bacilli mainly by self infection with faecal flora, many of which are first acquired from the hospital environment in food or on fomites. The use of plastic isolators is cumbersome, and of limited value except in the control of infection with Ps. aeruginosa. For this reason and because of the effectiveness of topical chemoprophylaxis such isolators are
doi_str_mv 10.1017/S002217240002180X
format Article
fullrecord <record><control><sourceid>jstor_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_2131052</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cupid>10_1017_S002217240002180X</cupid><jstor_id>3861599</jstor_id><sourcerecordid>3861599</sourcerecordid><originalsourceid>FETCH-LOGICAL-c412x-4b6dd24706ae743ed89cf3a3140e2910f0b6e412460d55a689b72989c9e71f303</originalsourceid><addsrcrecordid>eNp9kV1rFTEQhoMo9Vj9AYJCrnq3mu8PLwQptRUKbamCeBOyu7Ntjns2xyRb6r9v5CwHRehVBp5nJsO8CL2m5B0lVL-_JoQxqpkgtaCGfH-CVlQo2whB7FO0IlaShiljnqMXOa-rZZnRB-hAVl8JtkLXlykW6Eq4AxxyHH0JccJhwh63c5oynqdQPuByC3jOgOOAt6PPJXSLHVPGfuqxDwl3cyo-TPklejb4McOr5T1E3z6ffD0-a84vTr8cfzpvOkHZfSNa1fdMaKI8aMGhN7YbuOdUEGCWkoG0CqopFOml9MrYVjNbJQuaDpzwQ_RxN3c7txvoO5hK8qPbprDx6beLPrh_yRRu3U28c4xySiSrA46WASn-miEXtwm5g3H0E8Q5O0MZlZqZKtKd2KWYc4Jh_wkl7k8S7r8kas_bv7fbdyynr_zNjq9zveIec6OotLbiZodDLnC_xz79dEpzLZ06vXLsB7Pqykp3WX2-rOg3bQr9Dbh1rAnWAB5Z8gGDAqvI</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>81215728</pqid></control><display><type>article</type><title>Protective isolation in a burns unit: the use of plastic isolators and air curtains</title><source>MEDLINE</source><source>Jstor Complete Legacy</source><source>PubMed Central</source><creator>Lowbury, E. J. L. ; Babb, J. R. ; Ford, Pamela M.</creator><creatorcontrib>Lowbury, E. J. L. ; Babb, J. R. ; Ford, Pamela M.</creatorcontrib><description>The use of plastic isolators and of an ‘air curtain’ isolator for protection of patients against infection was studied in a burns unit. Preliminary bacteriological tests showed that very few airborne bacteria gained access to a plastic ventilated isolator; even when the filter and pre-filter were removed from the air inflow, settle-plate counts inside the isolator were much lower than those in the open ward, but the difference was smaller in tests made with an Anderson air sampler, which showed also that fewer large bacteria-carrying particles appeared inside the isolator than outside it. An open-topped isolator allowed virtually free access of bacteria from ambient air. The numbers of airborne bacteria inside an air curtain were appreciably lower than the counts of airborne bacteria in the open ward, but not as low as those in the plastic ventilated isolator. Controlled trials of isolators were made on patients with fresh burns of 4–30 % of the body surface; the patients were given no topical chemoprophylaxis against Staphylococcus aureus or Gram-negative bacilli. Patients treated in plastic isolators showed a significantly lower incidence of infection with Pseudomonas aeruginosa than those treated in the open ward; this protective effect was shown by isolators with or without filters or with an open top. Ventilated isolators, which protected patients against personal contact and airborne infection, gave a limited protection against multi-resistant ‘hospital’ strains of Staph. aureus, but no such protection was given by an open-topped isolator, which protected only against personal contact infection, or by air curtains, which protected only against airborne infection; the air curtain gave no protection against Ps. aeruginosa, and there was no evidence of protection by any isolator against Proteus spp. and coliform bacilli. Both the controlled trials and evidence from the bacteriology of air, hands, fomites and rectal and nasal swabs taken on admission and later, supported the view that Ps. aeruginosa is transferred mainly by personal contact, Staph. aureus probably by air as well as by contact and coliform bacilli mainly by self infection with faecal flora, many of which are first acquired from the hospital environment in food or on fomites. The use of plastic isolators is cumbersome, and of limited value except in the control of infection with Ps. aeruginosa. For this reason and because of the effectiveness of topical chemoprophylaxis such isolators are unlikely to have more than an occasional use in the treatment of burns. Though air curtains greatly reduce airborne contamination, their use in a burns unit does not appear to protect patients against infection when the alternative (and, for Ps. aeruginosa, more important) routes of contamination by personal contact and fomites are left open.</description><identifier>ISSN: 0950-2688</identifier><identifier>ISSN: 0022-1724</identifier><identifier>EISSN: 1469-4409</identifier><identifier>DOI: 10.1017/S002217240002180X</identifier><identifier>PMID: 5002642</identifier><language>eng</language><publisher>Cambridge, UK: Cambridge University Press</publisher><subject>Air Microbiology ; Air sampling ; Airborne microorganisms ; Bacteria ; Burn units ; Burns ; Burns - therapy ; Child ; Control groups ; Cross Infection - prevention &amp; control ; Curtains ; Drug Resistance, Microbial ; Feces - microbiology ; Hand - microbiology ; Hospital admissions ; Hospital Departments ; Humans ; Infections ; Nose - microbiology ; Patient Isolators ; Plastics ; Proteus ; Pseudomonas aeruginosa ; Pseudomonas Infections ; Rectum - microbiology ; Staphylococcal Infections - prevention &amp; control ; Staphylococcus</subject><ispartof>Epidemiology and infection, 1971-12, Vol.69 (4), p.529-546</ispartof><rights>Copyright © Cambridge University Press 1971</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c412x-4b6dd24706ae743ed89cf3a3140e2910f0b6e412460d55a689b72989c9e71f303</citedby><cites>FETCH-LOGICAL-c412x-4b6dd24706ae743ed89cf3a3140e2910f0b6e412460d55a689b72989c9e71f303</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.jstor.org/stable/pdf/3861599$$EPDF$$P50$$Gjstor$$H</linktopdf><linktohtml>$$Uhttps://www.jstor.org/stable/3861599$$EHTML$$P50$$Gjstor$$H</linktohtml><link.rule.ids>230,314,723,776,780,799,881,27903,27904,53769,53771,57995,58228</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/5002642$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lowbury, E. J. L.</creatorcontrib><creatorcontrib>Babb, J. R.</creatorcontrib><creatorcontrib>Ford, Pamela M.</creatorcontrib><title>Protective isolation in a burns unit: the use of plastic isolators and air curtains</title><title>Epidemiology and infection</title><addtitle>Epidemiol. Infect</addtitle><description>The use of plastic isolators and of an ‘air curtain’ isolator for protection of patients against infection was studied in a burns unit. Preliminary bacteriological tests showed that very few airborne bacteria gained access to a plastic ventilated isolator; even when the filter and pre-filter were removed from the air inflow, settle-plate counts inside the isolator were much lower than those in the open ward, but the difference was smaller in tests made with an Anderson air sampler, which showed also that fewer large bacteria-carrying particles appeared inside the isolator than outside it. An open-topped isolator allowed virtually free access of bacteria from ambient air. The numbers of airborne bacteria inside an air curtain were appreciably lower than the counts of airborne bacteria in the open ward, but not as low as those in the plastic ventilated isolator. Controlled trials of isolators were made on patients with fresh burns of 4–30 % of the body surface; the patients were given no topical chemoprophylaxis against Staphylococcus aureus or Gram-negative bacilli. Patients treated in plastic isolators showed a significantly lower incidence of infection with Pseudomonas aeruginosa than those treated in the open ward; this protective effect was shown by isolators with or without filters or with an open top. Ventilated isolators, which protected patients against personal contact and airborne infection, gave a limited protection against multi-resistant ‘hospital’ strains of Staph. aureus, but no such protection was given by an open-topped isolator, which protected only against personal contact infection, or by air curtains, which protected only against airborne infection; the air curtain gave no protection against Ps. aeruginosa, and there was no evidence of protection by any isolator against Proteus spp. and coliform bacilli. Both the controlled trials and evidence from the bacteriology of air, hands, fomites and rectal and nasal swabs taken on admission and later, supported the view that Ps. aeruginosa is transferred mainly by personal contact, Staph. aureus probably by air as well as by contact and coliform bacilli mainly by self infection with faecal flora, many of which are first acquired from the hospital environment in food or on fomites. The use of plastic isolators is cumbersome, and of limited value except in the control of infection with Ps. aeruginosa. For this reason and because of the effectiveness of topical chemoprophylaxis such isolators are unlikely to have more than an occasional use in the treatment of burns. Though air curtains greatly reduce airborne contamination, their use in a burns unit does not appear to protect patients against infection when the alternative (and, for Ps. aeruginosa, more important) routes of contamination by personal contact and fomites are left open.</description><subject>Air Microbiology</subject><subject>Air sampling</subject><subject>Airborne microorganisms</subject><subject>Bacteria</subject><subject>Burn units</subject><subject>Burns</subject><subject>Burns - therapy</subject><subject>Child</subject><subject>Control groups</subject><subject>Cross Infection - prevention &amp; control</subject><subject>Curtains</subject><subject>Drug Resistance, Microbial</subject><subject>Feces - microbiology</subject><subject>Hand - microbiology</subject><subject>Hospital admissions</subject><subject>Hospital Departments</subject><subject>Humans</subject><subject>Infections</subject><subject>Nose - microbiology</subject><subject>Patient Isolators</subject><subject>Plastics</subject><subject>Proteus</subject><subject>Pseudomonas aeruginosa</subject><subject>Pseudomonas Infections</subject><subject>Rectum - microbiology</subject><subject>Staphylococcal Infections - prevention &amp; control</subject><subject>Staphylococcus</subject><issn>0950-2688</issn><issn>0022-1724</issn><issn>1469-4409</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1971</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kV1rFTEQhoMo9Vj9AYJCrnq3mu8PLwQptRUKbamCeBOyu7Ntjns2xyRb6r9v5CwHRehVBp5nJsO8CL2m5B0lVL-_JoQxqpkgtaCGfH-CVlQo2whB7FO0IlaShiljnqMXOa-rZZnRB-hAVl8JtkLXlykW6Eq4AxxyHH0JccJhwh63c5oynqdQPuByC3jOgOOAt6PPJXSLHVPGfuqxDwl3cyo-TPklejb4McOr5T1E3z6ffD0-a84vTr8cfzpvOkHZfSNa1fdMaKI8aMGhN7YbuOdUEGCWkoG0CqopFOml9MrYVjNbJQuaDpzwQ_RxN3c7txvoO5hK8qPbprDx6beLPrh_yRRu3U28c4xySiSrA46WASn-miEXtwm5g3H0E8Q5O0MZlZqZKtKd2KWYc4Jh_wkl7k8S7r8kas_bv7fbdyynr_zNjq9zveIec6OotLbiZodDLnC_xz79dEpzLZ06vXLsB7Pqykp3WX2-rOg3bQr9Dbh1rAnWAB5Z8gGDAqvI</recordid><startdate>19711201</startdate><enddate>19711201</enddate><creator>Lowbury, E. J. L.</creator><creator>Babb, J. R.</creator><creator>Ford, Pamela M.</creator><general>Cambridge University Press</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>19711201</creationdate><title>Protective isolation in a burns unit: the use of plastic isolators and air curtains</title><author>Lowbury, E. J. L. ; Babb, J. R. ; Ford, Pamela M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c412x-4b6dd24706ae743ed89cf3a3140e2910f0b6e412460d55a689b72989c9e71f303</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1971</creationdate><topic>Air Microbiology</topic><topic>Air sampling</topic><topic>Airborne microorganisms</topic><topic>Bacteria</topic><topic>Burn units</topic><topic>Burns</topic><topic>Burns - therapy</topic><topic>Child</topic><topic>Control groups</topic><topic>Cross Infection - prevention &amp; control</topic><topic>Curtains</topic><topic>Drug Resistance, Microbial</topic><topic>Feces - microbiology</topic><topic>Hand - microbiology</topic><topic>Hospital admissions</topic><topic>Hospital Departments</topic><topic>Humans</topic><topic>Infections</topic><topic>Nose - microbiology</topic><topic>Patient Isolators</topic><topic>Plastics</topic><topic>Proteus</topic><topic>Pseudomonas aeruginosa</topic><topic>Pseudomonas Infections</topic><topic>Rectum - microbiology</topic><topic>Staphylococcal Infections - prevention &amp; control</topic><topic>Staphylococcus</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lowbury, E. J. L.</creatorcontrib><creatorcontrib>Babb, J. R.</creatorcontrib><creatorcontrib>Ford, Pamela M.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Epidemiology and infection</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lowbury, E. J. L.</au><au>Babb, J. R.</au><au>Ford, Pamela M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Protective isolation in a burns unit: the use of plastic isolators and air curtains</atitle><jtitle>Epidemiology and infection</jtitle><addtitle>Epidemiol. Infect</addtitle><date>1971-12-01</date><risdate>1971</risdate><volume>69</volume><issue>4</issue><spage>529</spage><epage>546</epage><pages>529-546</pages><issn>0950-2688</issn><issn>0022-1724</issn><eissn>1469-4409</eissn><abstract>The use of plastic isolators and of an ‘air curtain’ isolator for protection of patients against infection was studied in a burns unit. Preliminary bacteriological tests showed that very few airborne bacteria gained access to a plastic ventilated isolator; even when the filter and pre-filter were removed from the air inflow, settle-plate counts inside the isolator were much lower than those in the open ward, but the difference was smaller in tests made with an Anderson air sampler, which showed also that fewer large bacteria-carrying particles appeared inside the isolator than outside it. An open-topped isolator allowed virtually free access of bacteria from ambient air. The numbers of airborne bacteria inside an air curtain were appreciably lower than the counts of airborne bacteria in the open ward, but not as low as those in the plastic ventilated isolator. Controlled trials of isolators were made on patients with fresh burns of 4–30 % of the body surface; the patients were given no topical chemoprophylaxis against Staphylococcus aureus or Gram-negative bacilli. Patients treated in plastic isolators showed a significantly lower incidence of infection with Pseudomonas aeruginosa than those treated in the open ward; this protective effect was shown by isolators with or without filters or with an open top. Ventilated isolators, which protected patients against personal contact and airborne infection, gave a limited protection against multi-resistant ‘hospital’ strains of Staph. aureus, but no such protection was given by an open-topped isolator, which protected only against personal contact infection, or by air curtains, which protected only against airborne infection; the air curtain gave no protection against Ps. aeruginosa, and there was no evidence of protection by any isolator against Proteus spp. and coliform bacilli. Both the controlled trials and evidence from the bacteriology of air, hands, fomites and rectal and nasal swabs taken on admission and later, supported the view that Ps. aeruginosa is transferred mainly by personal contact, Staph. aureus probably by air as well as by contact and coliform bacilli mainly by self infection with faecal flora, many of which are first acquired from the hospital environment in food or on fomites. The use of plastic isolators is cumbersome, and of limited value except in the control of infection with Ps. aeruginosa. For this reason and because of the effectiveness of topical chemoprophylaxis such isolators are unlikely to have more than an occasional use in the treatment of burns. Though air curtains greatly reduce airborne contamination, their use in a burns unit does not appear to protect patients against infection when the alternative (and, for Ps. aeruginosa, more important) routes of contamination by personal contact and fomites are left open.</abstract><cop>Cambridge, UK</cop><pub>Cambridge University Press</pub><pmid>5002642</pmid><doi>10.1017/S002217240002180X</doi><tpages>18</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0950-2688
ispartof Epidemiology and infection, 1971-12, Vol.69 (4), p.529-546
issn 0950-2688
0022-1724
1469-4409
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_2131052
source MEDLINE; Jstor Complete Legacy; PubMed Central
subjects Air Microbiology
Air sampling
Airborne microorganisms
Bacteria
Burn units
Burns
Burns - therapy
Child
Control groups
Cross Infection - prevention & control
Curtains
Drug Resistance, Microbial
Feces - microbiology
Hand - microbiology
Hospital admissions
Hospital Departments
Humans
Infections
Nose - microbiology
Patient Isolators
Plastics
Proteus
Pseudomonas aeruginosa
Pseudomonas Infections
Rectum - microbiology
Staphylococcal Infections - prevention & control
Staphylococcus
title Protective isolation in a burns unit: the use of plastic isolators and air curtains
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-26T08%3A48%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-jstor_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Protective%20isolation%20in%20a%20burns%20unit:%20the%20use%20of%20plastic%20isolators%20and%20air%20curtains&rft.jtitle=Epidemiology%20and%20infection&rft.au=Lowbury,%20E.%20J.%20L.&rft.date=1971-12-01&rft.volume=69&rft.issue=4&rft.spage=529&rft.epage=546&rft.pages=529-546&rft.issn=0950-2688&rft.eissn=1469-4409&rft_id=info:doi/10.1017/S002217240002180X&rft_dat=%3Cjstor_pubme%3E3861599%3C/jstor_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=81215728&rft_id=info:pmid/5002642&rft_cupid=10_1017_S002217240002180X&rft_jstor_id=3861599&rfr_iscdi=true