Aerosol Hazards from Some Clinical Laboratory Apparatus
Infectious diseases, such as infectious hepatitis, may be transmitted from patients to staff in clinical laboratories and dialysis units during the performance of necessary procedures. This prompted us to examine the propensity of several items of commonly used apparatus to produce aerosols of infec...
Gespeichert in:
Veröffentlicht in: | BMJ 1972-03, Vol.1 (5800), p.594-597 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 597 |
---|---|
container_issue | 5800 |
container_start_page | 594 |
container_title | BMJ |
container_volume | 1 |
creator | Rutter, D. A. Evans, C. G. T. |
description | Infectious diseases, such as infectious hepatitis, may be transmitted from patients to staff in clinical laboratories and dialysis units during the performance of necessary procedures. This prompted us to examine the propensity of several items of commonly used apparatus to produce aerosols of infected blood. These were a microhaematocrit centrifuge, an AutoAnalyzer stirrer, and a microtonometer. We also compared some blood sample tubes with two types of lid. The results showed that all of these are potential sources of infection for laboratory staff. |
doi_str_mv | 10.1136/bmj.1.5800.594 |
format | Article |
fullrecord | <record><control><sourceid>jstor_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_1787591</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><jstor_id>25417901</jstor_id><sourcerecordid>25417901</sourcerecordid><originalsourceid>FETCH-LOGICAL-b507t-e2b6699eaa31a832bf820ddb9fedb0e48bbd0a5cb4d66c5fb6721427f6e52a013</originalsourceid><addsrcrecordid>eNqFkM1PwyAchonRzGXu6s2kiScPrUD5aC8my-accdEYv44EWqqd7ZjQGudfL3PL1JMnIO_Dj5cHgEMEI4RidqrqWYQimkAY0ZTsgC4iLAlpEse7oAsh5CEihO-DvnMzf8QxT1JGOqBDIYo91QV8oK1xpgom8lPa3AWFNXVwZ2odDKtyXmayCqZSGSsbY5fBYLGQftu6A7BXyMrp_mbtgYfx-f1wEk5vLi6Hg2moKORNqLFiLE21lDGSSYxVkWCY5yotdK6gJolSOZQ0UyRnLKOFYhwjgnnBNMXSl-yBs_XcRatqnWd63lhZiYUta2mXwshS_E3m5Yt4Nu8C8YTTdDXgeDPAmrdWu0bMTGvnvrNHOMPMKyOeitZU5m04q4vtCwiKlWrhVQskVqqFV-0vHP3utcU3Yn_ymfPitjGmBPH0-1_hOi9doz-2ubSvgvGYU3H9OBRj-kSuRrcjQT1_suZXPf7p9gVnLqAC</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1776261464</pqid></control><display><type>article</type><title>Aerosol Hazards from Some Clinical Laboratory Apparatus</title><source>MEDLINE</source><source>JSTOR Archive Collection A-Z Listing</source><source>PubMed Central</source><creator>Rutter, D. A. ; Evans, C. G. T.</creator><creatorcontrib>Rutter, D. A. ; Evans, C. G. T.</creatorcontrib><description>Infectious diseases, such as infectious hepatitis, may be transmitted from patients to staff in clinical laboratories and dialysis units during the performance of necessary procedures. This prompted us to examine the propensity of several items of commonly used apparatus to produce aerosols of infected blood. These were a microhaematocrit centrifuge, an AutoAnalyzer stirrer, and a microtonometer. We also compared some blood sample tubes with two types of lid. The results showed that all of these are potential sources of infection for laboratory staff.</description><identifier>ISSN: 0007-1447</identifier><identifier>ISSN: 0959-8138</identifier><identifier>EISSN: 1468-5833</identifier><identifier>DOI: 10.1136/bmj.1.5800.594</identifier><identifier>PMID: 5013833</identifier><language>eng</language><publisher>England: British Medical Journal Publishing Group</publisher><subject>Aerosols ; Air Microbiology ; Air sampling ; Autoanalysis ; Blood ; Centrifugation ; Health hazards ; Hematocrit ; Hepatitis A ; Humans ; Infections ; Infectious diseases ; Laboratory Infection - etiology ; Papers and Originals ; Radiation counters ; Specimens</subject><ispartof>BMJ, 1972-03, Vol.1 (5800), p.594-597</ispartof><rights>Copyright 1972 British Medical Journal</rights><rights>Copyright BMJ Publishing Group LTD Mar 4, 1972</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-b507t-e2b6699eaa31a832bf820ddb9fedb0e48bbd0a5cb4d66c5fb6721427f6e52a013</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.jstor.org/stable/pdf/25417901$$EPDF$$P50$$Gjstor$$H</linktopdf><linktohtml>$$Uhttps://www.jstor.org/stable/25417901$$EHTML$$P50$$Gjstor$$H</linktohtml><link.rule.ids>230,314,727,780,784,803,885,27924,27925,53791,53793,58017,58250</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/5013833$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Rutter, D. A.</creatorcontrib><creatorcontrib>Evans, C. G. T.</creatorcontrib><title>Aerosol Hazards from Some Clinical Laboratory Apparatus</title><title>BMJ</title><addtitle>Br Med J</addtitle><description>Infectious diseases, such as infectious hepatitis, may be transmitted from patients to staff in clinical laboratories and dialysis units during the performance of necessary procedures. This prompted us to examine the propensity of several items of commonly used apparatus to produce aerosols of infected blood. These were a microhaematocrit centrifuge, an AutoAnalyzer stirrer, and a microtonometer. We also compared some blood sample tubes with two types of lid. The results showed that all of these are potential sources of infection for laboratory staff.</description><subject>Aerosols</subject><subject>Air Microbiology</subject><subject>Air sampling</subject><subject>Autoanalysis</subject><subject>Blood</subject><subject>Centrifugation</subject><subject>Health hazards</subject><subject>Hematocrit</subject><subject>Hepatitis A</subject><subject>Humans</subject><subject>Infections</subject><subject>Infectious diseases</subject><subject>Laboratory Infection - etiology</subject><subject>Papers and Originals</subject><subject>Radiation counters</subject><subject>Specimens</subject><issn>0007-1447</issn><issn>0959-8138</issn><issn>1468-5833</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1972</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><recordid>eNqFkM1PwyAchonRzGXu6s2kiScPrUD5aC8my-accdEYv44EWqqd7ZjQGudfL3PL1JMnIO_Dj5cHgEMEI4RidqrqWYQimkAY0ZTsgC4iLAlpEse7oAsh5CEihO-DvnMzf8QxT1JGOqBDIYo91QV8oK1xpgom8lPa3AWFNXVwZ2odDKtyXmayCqZSGSsbY5fBYLGQftu6A7BXyMrp_mbtgYfx-f1wEk5vLi6Hg2moKORNqLFiLE21lDGSSYxVkWCY5yotdK6gJolSOZQ0UyRnLKOFYhwjgnnBNMXSl-yBs_XcRatqnWd63lhZiYUta2mXwshS_E3m5Yt4Nu8C8YTTdDXgeDPAmrdWu0bMTGvnvrNHOMPMKyOeitZU5m04q4vtCwiKlWrhVQskVqqFV-0vHP3utcU3Yn_ymfPitjGmBPH0-1_hOi9doz-2ubSvgvGYU3H9OBRj-kSuRrcjQT1_suZXPf7p9gVnLqAC</recordid><startdate>19720304</startdate><enddate>19720304</enddate><creator>Rutter, D. A.</creator><creator>Evans, C. G. T.</creator><general>British Medical Journal Publishing Group</general><general>British Medical Association</general><general>BMJ Publishing Group LTD</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7RV</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>BTHHO</scope><scope>CCPQU</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>KB0</scope><scope>M0S</scope><scope>M1P</scope><scope>NAPCQ</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>5PM</scope></search><sort><creationdate>19720304</creationdate><title>Aerosol Hazards from Some Clinical Laboratory Apparatus</title><author>Rutter, D. A. ; Evans, C. G. T.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-b507t-e2b6699eaa31a832bf820ddb9fedb0e48bbd0a5cb4d66c5fb6721427f6e52a013</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1972</creationdate><topic>Aerosols</topic><topic>Air Microbiology</topic><topic>Air sampling</topic><topic>Autoanalysis</topic><topic>Blood</topic><topic>Centrifugation</topic><topic>Health hazards</topic><topic>Hematocrit</topic><topic>Hepatitis A</topic><topic>Humans</topic><topic>Infections</topic><topic>Infectious diseases</topic><topic>Laboratory Infection - etiology</topic><topic>Papers and Originals</topic><topic>Radiation counters</topic><topic>Specimens</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Rutter, D. A.</creatorcontrib><creatorcontrib>Evans, C. G. T.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Nursing & Allied Health Database</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>BMJ Journals</collection><collection>ProQuest One Community College</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Nursing & Allied Health Database (Alumni Edition)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Nursing & Allied Health Premium</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>BMJ</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Rutter, D. A.</au><au>Evans, C. G. T.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Aerosol Hazards from Some Clinical Laboratory Apparatus</atitle><jtitle>BMJ</jtitle><addtitle>Br Med J</addtitle><date>1972-03-04</date><risdate>1972</risdate><volume>1</volume><issue>5800</issue><spage>594</spage><epage>597</epage><pages>594-597</pages><issn>0007-1447</issn><issn>0959-8138</issn><eissn>1468-5833</eissn><abstract>Infectious diseases, such as infectious hepatitis, may be transmitted from patients to staff in clinical laboratories and dialysis units during the performance of necessary procedures. This prompted us to examine the propensity of several items of commonly used apparatus to produce aerosols of infected blood. These were a microhaematocrit centrifuge, an AutoAnalyzer stirrer, and a microtonometer. We also compared some blood sample tubes with two types of lid. The results showed that all of these are potential sources of infection for laboratory staff.</abstract><cop>England</cop><pub>British Medical Journal Publishing Group</pub><pmid>5013833</pmid><doi>10.1136/bmj.1.5800.594</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0007-1447 |
ispartof | BMJ, 1972-03, Vol.1 (5800), p.594-597 |
issn | 0007-1447 0959-8138 1468-5833 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_1787591 |
source | MEDLINE; JSTOR Archive Collection A-Z Listing; PubMed Central |
subjects | Aerosols Air Microbiology Air sampling Autoanalysis Blood Centrifugation Health hazards Hematocrit Hepatitis A Humans Infections Infectious diseases Laboratory Infection - etiology Papers and Originals Radiation counters Specimens |
title | Aerosol Hazards from Some Clinical Laboratory Apparatus |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T18%3A35%3A33IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-jstor_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Aerosol%20Hazards%20from%20Some%20Clinical%20Laboratory%20Apparatus&rft.jtitle=BMJ&rft.au=Rutter,%20D.%20A.&rft.date=1972-03-04&rft.volume=1&rft.issue=5800&rft.spage=594&rft.epage=597&rft.pages=594-597&rft.issn=0007-1447&rft.eissn=1468-5833&rft_id=info:doi/10.1136/bmj.1.5800.594&rft_dat=%3Cjstor_pubme%3E25417901%3C/jstor_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1776261464&rft_id=info:pmid/5013833&rft_jstor_id=25417901&rfr_iscdi=true |