Stenting of “unprotected” left main coronary artery stenoses: early and late results
Objective To assess short and long term efficacy of coronary stent implantation for unprotected left main coronary artery stenosis. Design Retrospective follow up study. Setting Tertiary referral centre for interventional cardiology and cardiac surgery. Patients Eighteen consecutive patients (12 men...
Gespeichert in:
Veröffentlicht in: | Heart (British Cardiac Society) 1998-02, Vol.79 (2), p.148-152 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objective To assess short and long term efficacy of coronary stent implantation for unprotected left main coronary artery stenosis. Design Retrospective follow up study. Setting Tertiary referral centre for interventional cardiology and cardiac surgery. Patients Eighteen consecutive patients (12 men; age 70.8 years) between May 1993 and July 1996. Ten patients presented with stable angina and underwent the procedure electively, eight patients presented either with unstable angina or myocardial infarction and underwent the procedure in emergency. Intervention Johnson and Johnson Palmaz-Schatz stents were used in 16 patients, and a Microstent and a Gianturco-Roubin in one patient each. An intra-aortic balloon pump was prophylactively used for two patients in the elective group. In the acute group, six required an intra-aortic balloon pump. Main outcome measures Procedural success rate and major adverse cardiac events. Results Successful stent implantation was achieved in all patients. In the elective group, no major adverse cardiac event occurred during the procedure, but one patient had to undergo repeated angioplasty before discharge. All patients of the elective group were discharged alive and there has been one non-cardiac death during a follow up of (mean (SD)) 10 (4) months. In the emergency group, one patient died during the procedure, one patient developed a non Q-wave myocardial infarction, one patient underwent emergency coronary bypass surgery, while another patient died suddenly before hospital discharge. Six patients of the emergency group were discharged alive and there has been one non-cardiac death during a follow up of 7 (4) months. Conclusions Elective stent implantation for unprotected left main coronary artery stenosis is safe and effective in selected stable patients. Urgent stent implantation, however, cannot be considered as a definitive procedure in emergency situation. |
---|---|
ISSN: | 1355-6037 1468-201X |
DOI: | 10.1136/hrt.79.2.148 |