Assessment of 3 audible monitors during hypotension in anesthetized dogs

Severe hypotension was produced in 8 dogs during halothane anesthesia. Three monitors detecting respiratory rate, Doppler signal and pulse rate were compared to direct blood pressure measurements. Deep anesthesia was most consistently detected using the respiratory monitor. The signal fade of the Do...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Canadian veterinary journal 1997-09, Vol.38 (9), p.564-566
1. Verfasser: Dyson, D H
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Severe hypotension was produced in 8 dogs during halothane anesthesia. Three monitors detecting respiratory rate, Doppler signal and pulse rate were compared to direct blood pressure measurements. Deep anesthesia was most consistently detected using the respiratory monitor. The signal fade of the Doppler device was best at detecting hypotension from blood loss. Changes in heart rate were not useful.
ISSN:0008-5286