Atraumatic non-distorting pyloric sphincter pressure studies

Conflicting claims have been made regarding the physiological characteristics of the pyloric sphincter. Pyloric sphincter pressures were studied in 32 patients under basal conditions, after stimulation with HCl and posture changes. At gastroscopy a 2 mm diameter manometer catheter was placed in the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Gut 1980-10, Vol.21 (10), p.826-828
Hauptverfasser: McShane, A J, O'Morain, C, Lennon, J R, Coakley, J B, Alton, B G
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Conflicting claims have been made regarding the physiological characteristics of the pyloric sphincter. Pyloric sphincter pressures were studied in 32 patients under basal conditions, after stimulation with HCl and posture changes. At gastroscopy a 2 mm diameter manometer catheter was placed in the duodenum and three to five hours later the catheter was withdrawn slowly with continuous manometry. Lower esophageal sphincter pressures fell within the expected range but there was no definite evidence of a pressure barrier at the pylorus in any group of patients. The technique caused no patient discomfort and minimal distortion of the region under study, indicating that the pylorus is usually patent with a lumenal diameter greater than 2 mm.
ISSN:0017-5749
1468-3288
1458-3288
DOI:10.1136/gut.21.10.826