Comparison of serological techniques to measure antibody to Pasteurella haemolytica A1

Analysis of 45 sera was performed employing five techniques which are currently in use in three laboratories to measure anti-Pasteurella haemolytica antibodies. The enzyme linked immunosorbent assay, passive hemagglutination, complement fixation and direct and indirect bacterial agglutination assays...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Canadian journal of comparative medicine 1985, Vol.49 (1), p.99-103
Hauptverfasser: FILION, L. G, CHO, H. J, SHEWEN, P. E, RAYBOULD, T. J. G, WILKIE, B. N
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Analysis of 45 sera was performed employing five techniques which are currently in use in three laboratories to measure anti-Pasteurella haemolytica antibodies. The enzyme linked immunosorbent assay, passive hemagglutination, complement fixation and direct and indirect bacterial agglutination assays were employed and a relationship between tests in the measurement of anti-P. haemolytica antibodies was demonstrated. Regression analysis together with prediction and confidence intervals were tabulated also. The conclusion drawn from statistical analysis was that all five tests are similar in their ability to detect immune responses (antibody and antigen(s) interactions) to Pasteurella haemolytica.