Fungal Leadless Pacemaker Endocarditis Managed by Percutaneous Vacuum-Assisted Evacuation of Vegetation, Pacemaker Extraction, and Replacement
Leadless cardiac pacemakers (LCPs) mitigate the risks of traditional transvenous devices such as lead fracture and infection. Two LCPs are clinically available, using either a helix or tined active fixation approach. There are rare reports of LCP infection—all involving the tined device. We report t...
Gespeichert in:
Veröffentlicht in: | JACC. Case reports 2024-10, Vol.29 (19), p.102586, Article 102586 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 19 |
container_start_page | 102586 |
container_title | JACC. Case reports |
container_volume | 29 |
creator | Jia, Kelly Q. Beerkens, Frans J. Zhang, Chi Itagaki, Shinobu Dukkipati, Srinivas Reddy, Vivek Y. Musikantow, Daniel R. |
description | Leadless cardiac pacemakers (LCPs) mitigate the risks of traditional transvenous devices such as lead fracture and infection. Two LCPs are clinically available, using either a helix or tined active fixation approach. There are rare reports of LCP infection—all involving the tined device. We report the first pathologically confirmed fungal endocarditis involving a helix-based LCP. This was successfully managed by catheter-based mechanical vacuum evacuation of the vegetation, followed by device extraction and replacement.
[Display omitted] |
doi_str_mv | 10.1016/j.jaccas.2024.102586 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11522729</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S2666084924004935</els_id><sourcerecordid>3123075876</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2586-d73b85685802ace6d7825638f9edf94626640a156cb83d9362a64fd04f23e4b03</originalsourceid><addsrcrecordid>eNp9Uc1u1DAQjhAVrdq-AUI5ciCL_-I4F1BVbQFpq1YIerUm9mTxkp_Fdlb0KXgFnoUnw0tKtVw42Z75fjzzZdlzShaUUPl6s9iAMRAWjDCRSqxU8kl2wqSUBVGifnpwP87OQ9gQkkCU0po9y455LZTgtDrJflxNwxq6fIVgOwwhvwWDPXxFny8HOxrw1kUXfv28hgHWaPPmPr9Fb6YIA45TyO_ATFNfXITgQkz95S4VILpxyMc2v8M1xj-vV4fK36MHM1dhsPlH3Hb7Jg7xLDtqoQt4_nCeZp-vlp8u3xerm3cfLi9WhdmPWtiKN6qUqlSEJaa0lWKl5Kqt0ba1kGl4QYCW0jSK25pLBlK0loiWcRQN4afZ21l3OzU9WpOsPXR6610P_l6P4PS_ncF90etxpyktGatYnRRePij48duEIereBYNdNy9Gc8o4qUpVyQQVM9T4MQSP7aMPJXqfp97oOU-9z1PPeSbai8M_PpL-ppcAb2YApk3tHHodjMPBoHUeTdR2dP93-A2GsrYq</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3123075876</pqid></control><display><type>article</type><title>Fungal Leadless Pacemaker Endocarditis Managed by Percutaneous Vacuum-Assisted Evacuation of Vegetation, Pacemaker Extraction, and Replacement</title><source>DOAJ Directory of Open Access Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central</source><source>Alma/SFX Local Collection</source><creator>Jia, Kelly Q. ; Beerkens, Frans J. ; Zhang, Chi ; Itagaki, Shinobu ; Dukkipati, Srinivas ; Reddy, Vivek Y. ; Musikantow, Daniel R.</creator><creatorcontrib>Jia, Kelly Q. ; Beerkens, Frans J. ; Zhang, Chi ; Itagaki, Shinobu ; Dukkipati, Srinivas ; Reddy, Vivek Y. ; Musikantow, Daniel R.</creatorcontrib><description>Leadless cardiac pacemakers (LCPs) mitigate the risks of traditional transvenous devices such as lead fracture and infection. Two LCPs are clinically available, using either a helix or tined active fixation approach. There are rare reports of LCP infection—all involving the tined device. We report the first pathologically confirmed fungal endocarditis involving a helix-based LCP. This was successfully managed by catheter-based mechanical vacuum evacuation of the vegetation, followed by device extraction and replacement.
[Display omitted]</description><identifier>ISSN: 2666-0849</identifier><identifier>EISSN: 2666-0849</identifier><identifier>DOI: 10.1016/j.jaccas.2024.102586</identifier><identifier>PMID: 39484317</identifier><language>eng</language><publisher>Netherlands: Elsevier Inc</publisher><subject>fungal endocarditis ; leadless pacemaker ; Rhythm Disorders and Electrophysiology</subject><ispartof>JACC. Case reports, 2024-10, Vol.29 (19), p.102586, Article 102586</ispartof><rights>2024 The Authors</rights><rights>2024 The Authors.</rights><rights>2024 The Authors 2024</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2586-d73b85685802ace6d7825638f9edf94626640a156cb83d9362a64fd04f23e4b03</cites><orcidid>0000-0001-7123-4822</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC11522729/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC11522729/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,864,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39484317$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Jia, Kelly Q.</creatorcontrib><creatorcontrib>Beerkens, Frans J.</creatorcontrib><creatorcontrib>Zhang, Chi</creatorcontrib><creatorcontrib>Itagaki, Shinobu</creatorcontrib><creatorcontrib>Dukkipati, Srinivas</creatorcontrib><creatorcontrib>Reddy, Vivek Y.</creatorcontrib><creatorcontrib>Musikantow, Daniel R.</creatorcontrib><title>Fungal Leadless Pacemaker Endocarditis Managed by Percutaneous Vacuum-Assisted Evacuation of Vegetation, Pacemaker Extraction, and Replacement</title><title>JACC. Case reports</title><addtitle>JACC Case Rep</addtitle><description>Leadless cardiac pacemakers (LCPs) mitigate the risks of traditional transvenous devices such as lead fracture and infection. Two LCPs are clinically available, using either a helix or tined active fixation approach. There are rare reports of LCP infection—all involving the tined device. We report the first pathologically confirmed fungal endocarditis involving a helix-based LCP. This was successfully managed by catheter-based mechanical vacuum evacuation of the vegetation, followed by device extraction and replacement.
[Display omitted]</description><subject>fungal endocarditis</subject><subject>leadless pacemaker</subject><subject>Rhythm Disorders and Electrophysiology</subject><issn>2666-0849</issn><issn>2666-0849</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9Uc1u1DAQjhAVrdq-AUI5ciCL_-I4F1BVbQFpq1YIerUm9mTxkp_Fdlb0KXgFnoUnw0tKtVw42Z75fjzzZdlzShaUUPl6s9iAMRAWjDCRSqxU8kl2wqSUBVGifnpwP87OQ9gQkkCU0po9y455LZTgtDrJflxNwxq6fIVgOwwhvwWDPXxFny8HOxrw1kUXfv28hgHWaPPmPr9Fb6YIA45TyO_ATFNfXITgQkz95S4VILpxyMc2v8M1xj-vV4fK36MHM1dhsPlH3Hb7Jg7xLDtqoQt4_nCeZp-vlp8u3xerm3cfLi9WhdmPWtiKN6qUqlSEJaa0lWKl5Kqt0ba1kGl4QYCW0jSK25pLBlK0loiWcRQN4afZ21l3OzU9WpOsPXR6610P_l6P4PS_ncF90etxpyktGatYnRRePij48duEIereBYNdNy9Gc8o4qUpVyQQVM9T4MQSP7aMPJXqfp97oOU-9z1PPeSbai8M_PpL-ppcAb2YApk3tHHodjMPBoHUeTdR2dP93-A2GsrYq</recordid><startdate>20241002</startdate><enddate>20241002</enddate><creator>Jia, Kelly Q.</creator><creator>Beerkens, Frans J.</creator><creator>Zhang, Chi</creator><creator>Itagaki, Shinobu</creator><creator>Dukkipati, Srinivas</creator><creator>Reddy, Vivek Y.</creator><creator>Musikantow, Daniel R.</creator><general>Elsevier Inc</general><general>Elsevier</general><scope>6I.</scope><scope>AAFTH</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0001-7123-4822</orcidid></search><sort><creationdate>20241002</creationdate><title>Fungal Leadless Pacemaker Endocarditis Managed by Percutaneous Vacuum-Assisted Evacuation of Vegetation, Pacemaker Extraction, and Replacement</title><author>Jia, Kelly Q. ; Beerkens, Frans J. ; Zhang, Chi ; Itagaki, Shinobu ; Dukkipati, Srinivas ; Reddy, Vivek Y. ; Musikantow, Daniel R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2586-d73b85685802ace6d7825638f9edf94626640a156cb83d9362a64fd04f23e4b03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>fungal endocarditis</topic><topic>leadless pacemaker</topic><topic>Rhythm Disorders and Electrophysiology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jia, Kelly Q.</creatorcontrib><creatorcontrib>Beerkens, Frans J.</creatorcontrib><creatorcontrib>Zhang, Chi</creatorcontrib><creatorcontrib>Itagaki, Shinobu</creatorcontrib><creatorcontrib>Dukkipati, Srinivas</creatorcontrib><creatorcontrib>Reddy, Vivek Y.</creatorcontrib><creatorcontrib>Musikantow, Daniel R.</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>JACC. Case reports</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jia, Kelly Q.</au><au>Beerkens, Frans J.</au><au>Zhang, Chi</au><au>Itagaki, Shinobu</au><au>Dukkipati, Srinivas</au><au>Reddy, Vivek Y.</au><au>Musikantow, Daniel R.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fungal Leadless Pacemaker Endocarditis Managed by Percutaneous Vacuum-Assisted Evacuation of Vegetation, Pacemaker Extraction, and Replacement</atitle><jtitle>JACC. Case reports</jtitle><addtitle>JACC Case Rep</addtitle><date>2024-10-02</date><risdate>2024</risdate><volume>29</volume><issue>19</issue><spage>102586</spage><pages>102586-</pages><artnum>102586</artnum><issn>2666-0849</issn><eissn>2666-0849</eissn><abstract>Leadless cardiac pacemakers (LCPs) mitigate the risks of traditional transvenous devices such as lead fracture and infection. Two LCPs are clinically available, using either a helix or tined active fixation approach. There are rare reports of LCP infection—all involving the tined device. We report the first pathologically confirmed fungal endocarditis involving a helix-based LCP. This was successfully managed by catheter-based mechanical vacuum evacuation of the vegetation, followed by device extraction and replacement.
[Display omitted]</abstract><cop>Netherlands</cop><pub>Elsevier Inc</pub><pmid>39484317</pmid><doi>10.1016/j.jaccas.2024.102586</doi><orcidid>https://orcid.org/0000-0001-7123-4822</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2666-0849 |
ispartof | JACC. Case reports, 2024-10, Vol.29 (19), p.102586, Article 102586 |
issn | 2666-0849 2666-0849 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11522729 |
source | DOAJ Directory of Open Access Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central; Alma/SFX Local Collection |
subjects | fungal endocarditis leadless pacemaker Rhythm Disorders and Electrophysiology |
title | Fungal Leadless Pacemaker Endocarditis Managed by Percutaneous Vacuum-Assisted Evacuation of Vegetation, Pacemaker Extraction, and Replacement |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-22T17%3A31%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fungal%20Leadless%20Pacemaker%20Endocarditis%C2%A0Managed%20by%20Percutaneous%20Vacuum-Assisted%20Evacuation%20of%20Vegetation,%20Pacemaker%20Extraction,%20and%20Replacement&rft.jtitle=JACC.%20Case%20reports&rft.au=Jia,%20Kelly%20Q.&rft.date=2024-10-02&rft.volume=29&rft.issue=19&rft.spage=102586&rft.pages=102586-&rft.artnum=102586&rft.issn=2666-0849&rft.eissn=2666-0849&rft_id=info:doi/10.1016/j.jaccas.2024.102586&rft_dat=%3Cproquest_pubme%3E3123075876%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3123075876&rft_id=info:pmid/39484317&rft_els_id=S2666084924004935&rfr_iscdi=true |