Fungal Leadless Pacemaker Endocarditis Managed by Percutaneous Vacuum-Assisted Evacuation of Vegetation, Pacemaker Extraction, and Replacement

Leadless cardiac pacemakers (LCPs) mitigate the risks of traditional transvenous devices such as lead fracture and infection. Two LCPs are clinically available, using either a helix or tined active fixation approach. There are rare reports of LCP infection—all involving the tined device. We report t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:JACC. Case reports 2024-10, Vol.29 (19), p.102586, Article 102586
Hauptverfasser: Jia, Kelly Q., Beerkens, Frans J., Zhang, Chi, Itagaki, Shinobu, Dukkipati, Srinivas, Reddy, Vivek Y., Musikantow, Daniel R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 19
container_start_page 102586
container_title JACC. Case reports
container_volume 29
creator Jia, Kelly Q.
Beerkens, Frans J.
Zhang, Chi
Itagaki, Shinobu
Dukkipati, Srinivas
Reddy, Vivek Y.
Musikantow, Daniel R.
description Leadless cardiac pacemakers (LCPs) mitigate the risks of traditional transvenous devices such as lead fracture and infection. Two LCPs are clinically available, using either a helix or tined active fixation approach. There are rare reports of LCP infection—all involving the tined device. We report the first pathologically confirmed fungal endocarditis involving a helix-based LCP. This was successfully managed by catheter-based mechanical vacuum evacuation of the vegetation, followed by device extraction and replacement. [Display omitted]
doi_str_mv 10.1016/j.jaccas.2024.102586
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11522729</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S2666084924004935</els_id><sourcerecordid>3123075876</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2586-d73b85685802ace6d7825638f9edf94626640a156cb83d9362a64fd04f23e4b03</originalsourceid><addsrcrecordid>eNp9Uc1u1DAQjhAVrdq-AUI5ciCL_-I4F1BVbQFpq1YIerUm9mTxkp_Fdlb0KXgFnoUnw0tKtVw42Z75fjzzZdlzShaUUPl6s9iAMRAWjDCRSqxU8kl2wqSUBVGifnpwP87OQ9gQkkCU0po9y455LZTgtDrJflxNwxq6fIVgOwwhvwWDPXxFny8HOxrw1kUXfv28hgHWaPPmPr9Fb6YIA45TyO_ATFNfXITgQkz95S4VILpxyMc2v8M1xj-vV4fK36MHM1dhsPlH3Hb7Jg7xLDtqoQt4_nCeZp-vlp8u3xerm3cfLi9WhdmPWtiKN6qUqlSEJaa0lWKl5Kqt0ba1kGl4QYCW0jSK25pLBlK0loiWcRQN4afZ21l3OzU9WpOsPXR6610P_l6P4PS_ncF90etxpyktGatYnRRePij48duEIereBYNdNy9Gc8o4qUpVyQQVM9T4MQSP7aMPJXqfp97oOU-9z1PPeSbai8M_PpL-ppcAb2YApk3tHHodjMPBoHUeTdR2dP93-A2GsrYq</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3123075876</pqid></control><display><type>article</type><title>Fungal Leadless Pacemaker Endocarditis Managed by Percutaneous Vacuum-Assisted Evacuation of Vegetation, Pacemaker Extraction, and Replacement</title><source>DOAJ Directory of Open Access Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central</source><source>Alma/SFX Local Collection</source><creator>Jia, Kelly Q. ; Beerkens, Frans J. ; Zhang, Chi ; Itagaki, Shinobu ; Dukkipati, Srinivas ; Reddy, Vivek Y. ; Musikantow, Daniel R.</creator><creatorcontrib>Jia, Kelly Q. ; Beerkens, Frans J. ; Zhang, Chi ; Itagaki, Shinobu ; Dukkipati, Srinivas ; Reddy, Vivek Y. ; Musikantow, Daniel R.</creatorcontrib><description>Leadless cardiac pacemakers (LCPs) mitigate the risks of traditional transvenous devices such as lead fracture and infection. Two LCPs are clinically available, using either a helix or tined active fixation approach. There are rare reports of LCP infection—all involving the tined device. We report the first pathologically confirmed fungal endocarditis involving a helix-based LCP. This was successfully managed by catheter-based mechanical vacuum evacuation of the vegetation, followed by device extraction and replacement. [Display omitted]</description><identifier>ISSN: 2666-0849</identifier><identifier>EISSN: 2666-0849</identifier><identifier>DOI: 10.1016/j.jaccas.2024.102586</identifier><identifier>PMID: 39484317</identifier><language>eng</language><publisher>Netherlands: Elsevier Inc</publisher><subject>fungal endocarditis ; leadless pacemaker ; Rhythm Disorders and Electrophysiology</subject><ispartof>JACC. Case reports, 2024-10, Vol.29 (19), p.102586, Article 102586</ispartof><rights>2024 The Authors</rights><rights>2024 The Authors.</rights><rights>2024 The Authors 2024</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2586-d73b85685802ace6d7825638f9edf94626640a156cb83d9362a64fd04f23e4b03</cites><orcidid>0000-0001-7123-4822</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC11522729/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC11522729/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,864,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39484317$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Jia, Kelly Q.</creatorcontrib><creatorcontrib>Beerkens, Frans J.</creatorcontrib><creatorcontrib>Zhang, Chi</creatorcontrib><creatorcontrib>Itagaki, Shinobu</creatorcontrib><creatorcontrib>Dukkipati, Srinivas</creatorcontrib><creatorcontrib>Reddy, Vivek Y.</creatorcontrib><creatorcontrib>Musikantow, Daniel R.</creatorcontrib><title>Fungal Leadless Pacemaker Endocarditis Managed by Percutaneous Vacuum-Assisted Evacuation of Vegetation, Pacemaker Extraction, and Replacement</title><title>JACC. Case reports</title><addtitle>JACC Case Rep</addtitle><description>Leadless cardiac pacemakers (LCPs) mitigate the risks of traditional transvenous devices such as lead fracture and infection. Two LCPs are clinically available, using either a helix or tined active fixation approach. There are rare reports of LCP infection—all involving the tined device. We report the first pathologically confirmed fungal endocarditis involving a helix-based LCP. This was successfully managed by catheter-based mechanical vacuum evacuation of the vegetation, followed by device extraction and replacement. [Display omitted]</description><subject>fungal endocarditis</subject><subject>leadless pacemaker</subject><subject>Rhythm Disorders and Electrophysiology</subject><issn>2666-0849</issn><issn>2666-0849</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9Uc1u1DAQjhAVrdq-AUI5ciCL_-I4F1BVbQFpq1YIerUm9mTxkp_Fdlb0KXgFnoUnw0tKtVw42Z75fjzzZdlzShaUUPl6s9iAMRAWjDCRSqxU8kl2wqSUBVGifnpwP87OQ9gQkkCU0po9y455LZTgtDrJflxNwxq6fIVgOwwhvwWDPXxFny8HOxrw1kUXfv28hgHWaPPmPr9Fb6YIA45TyO_ATFNfXITgQkz95S4VILpxyMc2v8M1xj-vV4fK36MHM1dhsPlH3Hb7Jg7xLDtqoQt4_nCeZp-vlp8u3xerm3cfLi9WhdmPWtiKN6qUqlSEJaa0lWKl5Kqt0ba1kGl4QYCW0jSK25pLBlK0loiWcRQN4afZ21l3OzU9WpOsPXR6610P_l6P4PS_ncF90etxpyktGatYnRRePij48duEIereBYNdNy9Gc8o4qUpVyQQVM9T4MQSP7aMPJXqfp97oOU-9z1PPeSbai8M_PpL-ppcAb2YApk3tHHodjMPBoHUeTdR2dP93-A2GsrYq</recordid><startdate>20241002</startdate><enddate>20241002</enddate><creator>Jia, Kelly Q.</creator><creator>Beerkens, Frans J.</creator><creator>Zhang, Chi</creator><creator>Itagaki, Shinobu</creator><creator>Dukkipati, Srinivas</creator><creator>Reddy, Vivek Y.</creator><creator>Musikantow, Daniel R.</creator><general>Elsevier Inc</general><general>Elsevier</general><scope>6I.</scope><scope>AAFTH</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0001-7123-4822</orcidid></search><sort><creationdate>20241002</creationdate><title>Fungal Leadless Pacemaker Endocarditis Managed by Percutaneous Vacuum-Assisted Evacuation of Vegetation, Pacemaker Extraction, and Replacement</title><author>Jia, Kelly Q. ; Beerkens, Frans J. ; Zhang, Chi ; Itagaki, Shinobu ; Dukkipati, Srinivas ; Reddy, Vivek Y. ; Musikantow, Daniel R.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2586-d73b85685802ace6d7825638f9edf94626640a156cb83d9362a64fd04f23e4b03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>fungal endocarditis</topic><topic>leadless pacemaker</topic><topic>Rhythm Disorders and Electrophysiology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jia, Kelly Q.</creatorcontrib><creatorcontrib>Beerkens, Frans J.</creatorcontrib><creatorcontrib>Zhang, Chi</creatorcontrib><creatorcontrib>Itagaki, Shinobu</creatorcontrib><creatorcontrib>Dukkipati, Srinivas</creatorcontrib><creatorcontrib>Reddy, Vivek Y.</creatorcontrib><creatorcontrib>Musikantow, Daniel R.</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>JACC. Case reports</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jia, Kelly Q.</au><au>Beerkens, Frans J.</au><au>Zhang, Chi</au><au>Itagaki, Shinobu</au><au>Dukkipati, Srinivas</au><au>Reddy, Vivek Y.</au><au>Musikantow, Daniel R.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fungal Leadless Pacemaker Endocarditis Managed by Percutaneous Vacuum-Assisted Evacuation of Vegetation, Pacemaker Extraction, and Replacement</atitle><jtitle>JACC. Case reports</jtitle><addtitle>JACC Case Rep</addtitle><date>2024-10-02</date><risdate>2024</risdate><volume>29</volume><issue>19</issue><spage>102586</spage><pages>102586-</pages><artnum>102586</artnum><issn>2666-0849</issn><eissn>2666-0849</eissn><abstract>Leadless cardiac pacemakers (LCPs) mitigate the risks of traditional transvenous devices such as lead fracture and infection. Two LCPs are clinically available, using either a helix or tined active fixation approach. There are rare reports of LCP infection—all involving the tined device. We report the first pathologically confirmed fungal endocarditis involving a helix-based LCP. This was successfully managed by catheter-based mechanical vacuum evacuation of the vegetation, followed by device extraction and replacement. [Display omitted]</abstract><cop>Netherlands</cop><pub>Elsevier Inc</pub><pmid>39484317</pmid><doi>10.1016/j.jaccas.2024.102586</doi><orcidid>https://orcid.org/0000-0001-7123-4822</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2666-0849
ispartof JACC. Case reports, 2024-10, Vol.29 (19), p.102586, Article 102586
issn 2666-0849
2666-0849
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11522729
source DOAJ Directory of Open Access Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central; Alma/SFX Local Collection
subjects fungal endocarditis
leadless pacemaker
Rhythm Disorders and Electrophysiology
title Fungal Leadless Pacemaker Endocarditis Managed by Percutaneous Vacuum-Assisted Evacuation of Vegetation, Pacemaker Extraction, and Replacement
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-22T17%3A31%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fungal%20Leadless%20Pacemaker%20Endocarditis%C2%A0Managed%20by%20Percutaneous%20Vacuum-Assisted%20Evacuation%20of%20Vegetation,%20Pacemaker%20Extraction,%20and%20Replacement&rft.jtitle=JACC.%20Case%20reports&rft.au=Jia,%20Kelly%20Q.&rft.date=2024-10-02&rft.volume=29&rft.issue=19&rft.spage=102586&rft.pages=102586-&rft.artnum=102586&rft.issn=2666-0849&rft.eissn=2666-0849&rft_id=info:doi/10.1016/j.jaccas.2024.102586&rft_dat=%3Cproquest_pubme%3E3123075876%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3123075876&rft_id=info:pmid/39484317&rft_els_id=S2666084924004935&rfr_iscdi=true