How low can we go with the dialysate flow? A retrospective study on the safety and adequacy of a water-saving dialysis prescription

ABSTRACT Background Green nephrology encompasses all initiatives in kidney care that have a positive impact on climate and environment. To prepare the dialysate, at least 120 L of water are needed for one 4-h session with a dialysate flow (Qd) set at 500 mL/min. A lower dialysate flow rate is associ...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical kidney journal 2024-08, Vol.17 (8), p.sfae238
Hauptverfasser: Rydzewska-Rosołowska, Alicja, Głowińska, Irena, Kakareko, Katarzyna, Pietruczuk, Adam, Hryszko, Tomasz
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:ABSTRACT Background Green nephrology encompasses all initiatives in kidney care that have a positive impact on climate and environment. To prepare the dialysate, at least 120 L of water are needed for one 4-h session with a dialysate flow (Qd) set at 500 mL/min. A lower dialysate flow rate is associated with a significant reduction in the amount of water used. The aim of this study was to check whether change of Qd from 500 mL/min to 300 mL/min has a significant impact on dialysis adequacy. Methods The study was a retrospective analysis. Due to administrative issues, a satellite dialysis center reduced their dialysate flow to 300 mL/min for a month. The center then increased Qd to 500 mL/min again. We analyzed laboratory data from 3 months before dialysate flow reduction, in the month with Qd reduced to 300 mL/min, and from 3 months thereafter with Qd set at 500 mL/min. Results Twenty-four people were included in the final analysis. There were no significant changes in urea reduction ratio caused by lower rate of Qd [64.50 (61.75–71.00) vs 67.00 (63.00–72.25) vs 69.00 (63.75–72.25), analysis of variance F(2,46) = 0.71, P = .50]. Similarly, hemodialysis adequacy expressed by Kt/V did not differ at any Qd [1.23 (1.12–1.41) vs 1.25 (1.18–1.40) vs 1.35 (1.19–1.48), ANOVA F(2,46) = 2.51, P = .09]. There was a small but statistically significant increase in mean predialysis potassium with lower Qd [potassium = 5.18 (95% confidence interval, 95% CI, 4.96–5.44) vs 5.46 (95% CI 5.23–5.69) vs 5.23 (95% CI 4.99–5.47) mmol/L at Qd = 500, 300 and 500 mL/min, respectively, P = .039]. Conclusion Reduction in dialysate flow rate to 300 mL/min seems safe and does not cause any short-term negative effects in this small study. Thus, we might be able to achieve a similar therapeutic effect while saving water consumption. Larger, long-term studies incorporating patient-reported outcome measures are needed to confirm the efficacy of this approach. Graphical Abstract Graphical Abstract Video Abstract 10.1093/ckj/sfae238 Video Abstract Watch the video abstract of this contribution https://academic.oup.com/ckj/pages/author_videos sfae238Media1 6360973178112
ISSN:2048-8505
2048-8513
DOI:10.1093/ckj/sfae238