An evaluation of simultaneously administered free and intrinsic factor bound radioactive cyanocobalamin in the diagnosis of pernicious anaemia in the elderly

The definitive diagnosis of pernicious anaemia (PA) in the elderly is by no means always straightforward, particularly when inappropriate medication has been introduced before the institution of specific investigatory procedures. A detailed haematological study was carried out on 301 patients aged 6...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of clinical pathology 1979-03, Vol.32 (3), p.244-250
Hauptverfasser: Pathy, M. S., Kirkman, S., Molloy, M. J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 250
container_issue 3
container_start_page 244
container_title Journal of clinical pathology
container_volume 32
creator Pathy, M. S.
Kirkman, S.
Molloy, M. J.
description The definitive diagnosis of pernicious anaemia (PA) in the elderly is by no means always straightforward, particularly when inappropriate medication has been introduced before the institution of specific investigatory procedures. A detailed haematological study was carried out on 301 patients aged 60-95 with a serum B12 concentration at the laboratory's lower level of normal of 150 ng per litre (Euglena gracilis assay). The diagnosis of PA was based on strict predetermined haematological criteria. All patients were subsequently studied by the simultaneous oral administration of the dual isotopes 57Co-labelled B12 bound to intrinsic factor and free 58Co-labelled B12 (Dicopac test), and urine was collected over 24 hours after an intramuscular dose of 1 mg nonradioactive B12 for estimation of the 57Co/58Co B12 ratio; 255 patients satisfied all criteria for final analysis. The Radiochemical Centre, Amersham suggests an upper limit of the normal range for the 57Co/58Co ratio of 1·3 with a lower limit for PA of 2·0. We were unable to show a sharp borderline in the 57Co/58Co B12 ratio between those patients shown by other criteria to have PA and those who do not have PA; 34% of the 71 established patients had a ratio below 2·0. From our series a ratio borderline drawn at 1·4 gave only one false negative (1·4% of the PA group). Of the 175 non-PA cases, nine (5%) gave false positive results; four of these had 58Co excretion levels high enough to make misdiagnosis unlikely. In a proportion of patients the 57Co/58Co B12 ratio was estimated at regular intervals for 36-hour periods. Maximum accuracy of isotope measurement on a single specimen was obtained 8-20 hours after isotope dosing. The Dicopac investigation is a useful simple screening test in the differential diagnosis of patients with a megaloblastic bone marrow and combined low serum B12 and folate concentrations. When carried out by the standard technique, the degree of discrimination between normal and abnormal ratios is of limited diagnostic significance in one-third of patients.
doi_str_mv 10.1136/jcp.32.3.244
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_1145630</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3971107971</sourcerecordid><originalsourceid>FETCH-LOGICAL-b476t-cac4a3f9461c677748e8665b767103bd001dfa19fb6274ad7e36d78b83feb3673</originalsourceid><addsrcrecordid>eNp9kc2O0zAUhSPEXxnYsWRhCQk2pNixayebkYaKAaQZEBKwYGPd2DczLold7KSiD8O74ipDBSxYWfL5fO49PkXxmNElY1y-3JjtkldLvqyEuFUsmFBVKZiQt4sFpRUrGyXk_eJBShtKGVeM3yvuiqpZNdWi-HnmCe6gn2B0wZPQkeSGqR_BY5hSvydgB-ddGjGiJV1EJOAtcX6MzidnSAdmDJG0YcrXEawL-cLtkJg9-GBCCz1kh_yCjNdIrIMrH5JLh1FbjN4ZlwdlU8DBwW8Me4ux3z8s7nTQJ3x0c54Un89ff1q_LS8-vHm3PrsoW6HkWBowAnjXCMmMVEqJGmspV62SilHe2hzbdsCarpWVEmAVcmlV3da8w5ZLxU-K09l3O7UDWoM5HvR6G90Aca8DOP234t21vgo7zZhYSU6zwbMbgxi-T5hGPbhksO_nf9RKrKiQtczg03_ATZiiz-E0U4oKxmh1sHsxUyaGlCJ2x1UY1YfOde5c80pznTvP-JM_1z_Cc8lZLmf5UOOPowrxm87Z1Uq__7LW51_55av646U-7Ph85tth8__BvwBDGMfi</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1770411020</pqid></control><display><type>article</type><title>An evaluation of simultaneously administered free and intrinsic factor bound radioactive cyanocobalamin in the diagnosis of pernicious anaemia in the elderly</title><source>MEDLINE</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><source>Alma/SFX Local Collection</source><creator>Pathy, M. S. ; Kirkman, S. ; Molloy, M. J.</creator><creatorcontrib>Pathy, M. S. ; Kirkman, S. ; Molloy, M. J.</creatorcontrib><description>The definitive diagnosis of pernicious anaemia (PA) in the elderly is by no means always straightforward, particularly when inappropriate medication has been introduced before the institution of specific investigatory procedures. A detailed haematological study was carried out on 301 patients aged 60-95 with a serum B12 concentration at the laboratory's lower level of normal of 150 ng per litre (Euglena gracilis assay). The diagnosis of PA was based on strict predetermined haematological criteria. All patients were subsequently studied by the simultaneous oral administration of the dual isotopes 57Co-labelled B12 bound to intrinsic factor and free 58Co-labelled B12 (Dicopac test), and urine was collected over 24 hours after an intramuscular dose of 1 mg nonradioactive B12 for estimation of the 57Co/58Co B12 ratio; 255 patients satisfied all criteria for final analysis. The Radiochemical Centre, Amersham suggests an upper limit of the normal range for the 57Co/58Co ratio of 1·3 with a lower limit for PA of 2·0. We were unable to show a sharp borderline in the 57Co/58Co B12 ratio between those patients shown by other criteria to have PA and those who do not have PA; 34% of the 71 established patients had a ratio below 2·0. From our series a ratio borderline drawn at 1·4 gave only one false negative (1·4% of the PA group). Of the 175 non-PA cases, nine (5%) gave false positive results; four of these had 58Co excretion levels high enough to make misdiagnosis unlikely. In a proportion of patients the 57Co/58Co B12 ratio was estimated at regular intervals for 36-hour periods. Maximum accuracy of isotope measurement on a single specimen was obtained 8-20 hours after isotope dosing. The Dicopac investigation is a useful simple screening test in the differential diagnosis of patients with a megaloblastic bone marrow and combined low serum B12 and folate concentrations. When carried out by the standard technique, the degree of discrimination between normal and abnormal ratios is of limited diagnostic significance in one-third of patients.</description><identifier>ISSN: 0021-9746</identifier><identifier>EISSN: 1472-4146</identifier><identifier>DOI: 10.1136/jcp.32.3.244</identifier><identifier>PMID: 429592</identifier><identifier>CODEN: JCPAAK</identifier><language>eng</language><publisher>England: BMJ Publishing Group Ltd and Association of Clinical Pathologists</publisher><subject>Aged ; Anemia, Megaloblastic - diagnosis ; Anemia, Pernicious - diagnosis ; Cobalt Radioisotopes ; Diagnosis, Differential ; Humans ; Intrinsic Factor - metabolism ; Middle Aged ; Vitamin B 12 - metabolism</subject><ispartof>Journal of clinical pathology, 1979-03, Vol.32 (3), p.244-250</ispartof><rights>Copyright BMJ Publishing Group LTD Mar 1979</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-b476t-cac4a3f9461c677748e8665b767103bd001dfa19fb6274ad7e36d78b83feb3673</citedby><cites>FETCH-LOGICAL-b476t-cac4a3f9461c677748e8665b767103bd001dfa19fb6274ad7e36d78b83feb3673</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC1145630/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC1145630/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/429592$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Pathy, M. S.</creatorcontrib><creatorcontrib>Kirkman, S.</creatorcontrib><creatorcontrib>Molloy, M. J.</creatorcontrib><title>An evaluation of simultaneously administered free and intrinsic factor bound radioactive cyanocobalamin in the diagnosis of pernicious anaemia in the elderly</title><title>Journal of clinical pathology</title><addtitle>J Clin Pathol</addtitle><description>The definitive diagnosis of pernicious anaemia (PA) in the elderly is by no means always straightforward, particularly when inappropriate medication has been introduced before the institution of specific investigatory procedures. A detailed haematological study was carried out on 301 patients aged 60-95 with a serum B12 concentration at the laboratory's lower level of normal of 150 ng per litre (Euglena gracilis assay). The diagnosis of PA was based on strict predetermined haematological criteria. All patients were subsequently studied by the simultaneous oral administration of the dual isotopes 57Co-labelled B12 bound to intrinsic factor and free 58Co-labelled B12 (Dicopac test), and urine was collected over 24 hours after an intramuscular dose of 1 mg nonradioactive B12 for estimation of the 57Co/58Co B12 ratio; 255 patients satisfied all criteria for final analysis. The Radiochemical Centre, Amersham suggests an upper limit of the normal range for the 57Co/58Co ratio of 1·3 with a lower limit for PA of 2·0. We were unable to show a sharp borderline in the 57Co/58Co B12 ratio between those patients shown by other criteria to have PA and those who do not have PA; 34% of the 71 established patients had a ratio below 2·0. From our series a ratio borderline drawn at 1·4 gave only one false negative (1·4% of the PA group). Of the 175 non-PA cases, nine (5%) gave false positive results; four of these had 58Co excretion levels high enough to make misdiagnosis unlikely. In a proportion of patients the 57Co/58Co B12 ratio was estimated at regular intervals for 36-hour periods. Maximum accuracy of isotope measurement on a single specimen was obtained 8-20 hours after isotope dosing. The Dicopac investigation is a useful simple screening test in the differential diagnosis of patients with a megaloblastic bone marrow and combined low serum B12 and folate concentrations. When carried out by the standard technique, the degree of discrimination between normal and abnormal ratios is of limited diagnostic significance in one-third of patients.</description><subject>Aged</subject><subject>Anemia, Megaloblastic - diagnosis</subject><subject>Anemia, Pernicious - diagnosis</subject><subject>Cobalt Radioisotopes</subject><subject>Diagnosis, Differential</subject><subject>Humans</subject><subject>Intrinsic Factor - metabolism</subject><subject>Middle Aged</subject><subject>Vitamin B 12 - metabolism</subject><issn>0021-9746</issn><issn>1472-4146</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1979</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNp9kc2O0zAUhSPEXxnYsWRhCQk2pNixayebkYaKAaQZEBKwYGPd2DczLold7KSiD8O74ipDBSxYWfL5fO49PkXxmNElY1y-3JjtkldLvqyEuFUsmFBVKZiQt4sFpRUrGyXk_eJBShtKGVeM3yvuiqpZNdWi-HnmCe6gn2B0wZPQkeSGqR_BY5hSvydgB-ddGjGiJV1EJOAtcX6MzidnSAdmDJG0YcrXEawL-cLtkJg9-GBCCz1kh_yCjNdIrIMrH5JLh1FbjN4ZlwdlU8DBwW8Me4ux3z8s7nTQJ3x0c54Un89ff1q_LS8-vHm3PrsoW6HkWBowAnjXCMmMVEqJGmspV62SilHe2hzbdsCarpWVEmAVcmlV3da8w5ZLxU-K09l3O7UDWoM5HvR6G90Aca8DOP234t21vgo7zZhYSU6zwbMbgxi-T5hGPbhksO_nf9RKrKiQtczg03_ATZiiz-E0U4oKxmh1sHsxUyaGlCJ2x1UY1YfOde5c80pznTvP-JM_1z_Cc8lZLmf5UOOPowrxm87Z1Uq__7LW51_55av646U-7Ph85tth8__BvwBDGMfi</recordid><startdate>19790301</startdate><enddate>19790301</enddate><creator>Pathy, M. S.</creator><creator>Kirkman, S.</creator><creator>Molloy, M. J.</creator><general>BMJ Publishing Group Ltd and Association of Clinical Pathologists</general><general>BMJ Publishing Group LTD</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>88I</scope><scope>8AF</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BTHHO</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>M2P</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>Q9U</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>19790301</creationdate><title>An evaluation of simultaneously administered free and intrinsic factor bound radioactive cyanocobalamin in the diagnosis of pernicious anaemia in the elderly</title><author>Pathy, M. S. ; Kirkman, S. ; Molloy, M. J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-b476t-cac4a3f9461c677748e8665b767103bd001dfa19fb6274ad7e36d78b83feb3673</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1979</creationdate><topic>Aged</topic><topic>Anemia, Megaloblastic - diagnosis</topic><topic>Anemia, Pernicious - diagnosis</topic><topic>Cobalt Radioisotopes</topic><topic>Diagnosis, Differential</topic><topic>Humans</topic><topic>Intrinsic Factor - metabolism</topic><topic>Middle Aged</topic><topic>Vitamin B 12 - metabolism</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Pathy, M. S.</creatorcontrib><creatorcontrib>Kirkman, S.</creatorcontrib><creatorcontrib>Molloy, M. J.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Science Database (Alumni Edition)</collection><collection>STEM Database</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>BMJ Journals</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Science Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest Central Basic</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of clinical pathology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Pathy, M. S.</au><au>Kirkman, S.</au><au>Molloy, M. J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An evaluation of simultaneously administered free and intrinsic factor bound radioactive cyanocobalamin in the diagnosis of pernicious anaemia in the elderly</atitle><jtitle>Journal of clinical pathology</jtitle><addtitle>J Clin Pathol</addtitle><date>1979-03-01</date><risdate>1979</risdate><volume>32</volume><issue>3</issue><spage>244</spage><epage>250</epage><pages>244-250</pages><issn>0021-9746</issn><eissn>1472-4146</eissn><coden>JCPAAK</coden><abstract>The definitive diagnosis of pernicious anaemia (PA) in the elderly is by no means always straightforward, particularly when inappropriate medication has been introduced before the institution of specific investigatory procedures. A detailed haematological study was carried out on 301 patients aged 60-95 with a serum B12 concentration at the laboratory's lower level of normal of 150 ng per litre (Euglena gracilis assay). The diagnosis of PA was based on strict predetermined haematological criteria. All patients were subsequently studied by the simultaneous oral administration of the dual isotopes 57Co-labelled B12 bound to intrinsic factor and free 58Co-labelled B12 (Dicopac test), and urine was collected over 24 hours after an intramuscular dose of 1 mg nonradioactive B12 for estimation of the 57Co/58Co B12 ratio; 255 patients satisfied all criteria for final analysis. The Radiochemical Centre, Amersham suggests an upper limit of the normal range for the 57Co/58Co ratio of 1·3 with a lower limit for PA of 2·0. We were unable to show a sharp borderline in the 57Co/58Co B12 ratio between those patients shown by other criteria to have PA and those who do not have PA; 34% of the 71 established patients had a ratio below 2·0. From our series a ratio borderline drawn at 1·4 gave only one false negative (1·4% of the PA group). Of the 175 non-PA cases, nine (5%) gave false positive results; four of these had 58Co excretion levels high enough to make misdiagnosis unlikely. In a proportion of patients the 57Co/58Co B12 ratio was estimated at regular intervals for 36-hour periods. Maximum accuracy of isotope measurement on a single specimen was obtained 8-20 hours after isotope dosing. The Dicopac investigation is a useful simple screening test in the differential diagnosis of patients with a megaloblastic bone marrow and combined low serum B12 and folate concentrations. When carried out by the standard technique, the degree of discrimination between normal and abnormal ratios is of limited diagnostic significance in one-third of patients.</abstract><cop>England</cop><pub>BMJ Publishing Group Ltd and Association of Clinical Pathologists</pub><pmid>429592</pmid><doi>10.1136/jcp.32.3.244</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0021-9746
ispartof Journal of clinical pathology, 1979-03, Vol.32 (3), p.244-250
issn 0021-9746
1472-4146
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_1145630
source MEDLINE; EZB-FREE-00999 freely available EZB journals; PubMed Central; Alma/SFX Local Collection
subjects Aged
Anemia, Megaloblastic - diagnosis
Anemia, Pernicious - diagnosis
Cobalt Radioisotopes
Diagnosis, Differential
Humans
Intrinsic Factor - metabolism
Middle Aged
Vitamin B 12 - metabolism
title An evaluation of simultaneously administered free and intrinsic factor bound radioactive cyanocobalamin in the diagnosis of pernicious anaemia in the elderly
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T23%3A16%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20evaluation%20of%20simultaneously%20administered%20free%20and%20intrinsic%20factor%20bound%20radioactive%20cyanocobalamin%20in%20the%20diagnosis%20of%20pernicious%20anaemia%20in%20the%20elderly&rft.jtitle=Journal%20of%20clinical%20pathology&rft.au=Pathy,%20M.%20S.&rft.date=1979-03-01&rft.volume=32&rft.issue=3&rft.spage=244&rft.epage=250&rft.pages=244-250&rft.issn=0021-9746&rft.eissn=1472-4146&rft.coden=JCPAAK&rft_id=info:doi/10.1136/jcp.32.3.244&rft_dat=%3Cproquest_pubme%3E3971107971%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1770411020&rft_id=info:pmid/429592&rfr_iscdi=true