Utilizing Leadless Pacemakers in Extremely Elderly Patients With a Conventional Pacemaker System: A Two-Year Follow-Up Case Series Without Generator Extraction in High-Risk Scenarios

Background and objectives Leadless pacemakers, known for their safer clinical profile, offer significant advantages for elderly patients at a higher risk of complications associated with transvenous pacemaker procedures, particularly those susceptible to high-risk bleeding and infections related to...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Curēus (Palo Alto, CA) CA), 2024-08, Vol.16 (8), p.e67003
Hauptverfasser: Chu, Man Fong, Tam, Weng Chio, Lam, Kuok Wun, Chan, Chon Hou, Évora, Màrio, Lam, U Po
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 8
container_start_page e67003
container_title Curēus (Palo Alto, CA)
container_volume 16
creator Chu, Man Fong
Tam, Weng Chio
Lam, Kuok Wun
Chan, Chon Hou
Évora, Màrio
Lam, U Po
description Background and objectives Leadless pacemakers, known for their safer clinical profile, offer significant advantages for elderly patients at a higher risk of complications associated with transvenous pacemaker procedures, particularly those susceptible to high-risk bleeding and infections related to cardiac implantable electronic device interventions. This study explores an alternative use of leadless pacemakers without removing existing transvenous systems, deviating from conventional generator replacement and lead re-interventions. Methods This study was conducted with full approval from the Institutional Review Board, Medical Ethical Committee, Centro Hospitalar Conde São Januário, Macau. Between January 2018 and December 2021, we conducted a retrospective case series involving extremely elderly individuals (aged 85 years or older) at a high risk of complications, necessitating either generator replacement or lead re-implantation. The study considered implanting a leadless pacemaker (Micra; Medtronic, Minneapolis, MN, USA) without removing the transvenous generator. For the primary endpoints, we evaluated procedure-related complications and clinical outcomes during hospitalization. Secondary endpoints included the stability of parameters and any unexpected interference or interactions between the two systems during the two-year follow-up. Results Eleven patients (aged 86-101) were enrolled, most receiving antiplatelet or anticoagulation therapy. Leadless pacemaker implantation proceeded without major complications or adverse clinical outcomes during hospitalization. Regular follow-up was conducted every three to six months for adjusting pacemaker parameters and interrogating each patient. Over two years, three patients died from non-cardiac causes: two from infection and one from spontaneous intracranial hemorrhage, while eight completed regular follow-ups. We didn't detect any episodes of ventricular arrhythmias or intracardiac capture from the transvenous pacemaker system. We observed the stability in both the longevity and the voltage of the conventional generator battery, maintaining similar parameters without significant depletion (mean voltage decline: -0.07V/year). Parameters of the leadless pacemaker remained consistently normal without interference with existing pacing systems. Conclusion Implanting leadless pacemakers without removing transvenous pacemaker generators appears safe and effective for extremely elderly patients who are at high risk
doi_str_mv 10.7759/cureus.67003
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11403653</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3106457668</sourcerecordid><originalsourceid>FETCH-LOGICAL-c300t-7fc7c8ac8698a2d66fe7e79e996e71e56e69d7fea45a39da2931b9195b44d4e13</originalsourceid><addsrcrecordid>eNpdkkFvEzEQhVcIRKvSG2dkiQsHttjrXXvNBVVR2iJFomoaIU7WxDtJ3HrXqe1tCT-M38emaUvhNGP585vn0cuyt4weSVmpT6YP2McjISnlL7L9gok6r1ldvnzW72WHMV5RShmVBZX0dbbHVVELyfh-9nuWrLO_bLckE4TGYYzkHAy2cI0hEtuR8c8UsEW3IWPXYBjqOSSLXYrku00rAmTku9vhbH0H7u9jMt3EhO1nckwu73z-AyGQE--cv8tnazKCiGSKweJOxveJnGKHAZIP9zPBbBW3Ds7scpVf2HhNpgY7CNbHN9mrBbiIhw_1IJudjC9HZ_nk2-nX0fEkN5zSlMuFkaYGUwtVQ9EIsUCJUqFSAiXDSqBQjVwglBVw1UChOJsrpqp5WTYlMn6Qfdnprvt5i80wfjDm9DrYFsJGe7D635vOrvTS32rGSspFxQeFDw8Kwd_0GJNubTToHHTo-6g5o6KspBD1gL7_D73yfRiWuqUY47VkBR2ojzvKBB9jwMWTG0b1NhR6Fwp9H4oBf_f8B0_wYwT4H9aGt28</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3111387120</pqid></control><display><type>article</type><title>Utilizing Leadless Pacemakers in Extremely Elderly Patients With a Conventional Pacemaker System: A Two-Year Follow-Up Case Series Without Generator Extraction in High-Risk Scenarios</title><source>PubMed Central</source><source>PubMed Central Open Access</source><creator>Chu, Man Fong ; Tam, Weng Chio ; Lam, Kuok Wun ; Chan, Chon Hou ; Évora, Màrio ; Lam, U Po</creator><creatorcontrib>Chu, Man Fong ; Tam, Weng Chio ; Lam, Kuok Wun ; Chan, Chon Hou ; Évora, Màrio ; Lam, U Po</creatorcontrib><description>Background and objectives Leadless pacemakers, known for their safer clinical profile, offer significant advantages for elderly patients at a higher risk of complications associated with transvenous pacemaker procedures, particularly those susceptible to high-risk bleeding and infections related to cardiac implantable electronic device interventions. This study explores an alternative use of leadless pacemakers without removing existing transvenous systems, deviating from conventional generator replacement and lead re-interventions. Methods This study was conducted with full approval from the Institutional Review Board, Medical Ethical Committee, Centro Hospitalar Conde São Januário, Macau. Between January 2018 and December 2021, we conducted a retrospective case series involving extremely elderly individuals (aged 85 years or older) at a high risk of complications, necessitating either generator replacement or lead re-implantation. The study considered implanting a leadless pacemaker (Micra; Medtronic, Minneapolis, MN, USA) without removing the transvenous generator. For the primary endpoints, we evaluated procedure-related complications and clinical outcomes during hospitalization. Secondary endpoints included the stability of parameters and any unexpected interference or interactions between the two systems during the two-year follow-up. Results Eleven patients (aged 86-101) were enrolled, most receiving antiplatelet or anticoagulation therapy. Leadless pacemaker implantation proceeded without major complications or adverse clinical outcomes during hospitalization. Regular follow-up was conducted every three to six months for adjusting pacemaker parameters and interrogating each patient. Over two years, three patients died from non-cardiac causes: two from infection and one from spontaneous intracranial hemorrhage, while eight completed regular follow-ups. We didn't detect any episodes of ventricular arrhythmias or intracardiac capture from the transvenous pacemaker system. We observed the stability in both the longevity and the voltage of the conventional generator battery, maintaining similar parameters without significant depletion (mean voltage decline: -0.07V/year). Parameters of the leadless pacemaker remained consistently normal without interference with existing pacing systems. Conclusion Implanting leadless pacemakers without removing transvenous pacemaker generators appears safe and effective for extremely elderly patients who are at high risk of complications. Comprehensive two-year follow-up supports the safety and viability of this approach. Opting for this approach instead of conventional generator replacement, with or without additional lead implantation, may be reasonable in this population. However, further research within this patient cohort, such as exploring long-term outcomes beyond two years or comparing clinical outcomes with conventional strategies, may be necessary.</description><identifier>ISSN: 2168-8184</identifier><identifier>EISSN: 2168-8184</identifier><identifier>DOI: 10.7759/cureus.67003</identifier><identifier>PMID: 39286713</identifier><language>eng</language><publisher>United States: Cureus Inc</publisher><subject>Body mass index ; Cardiac arrhythmia ; Cardiology ; Cardiovascular disease ; Clinical outcomes ; Diabetes ; Hematoma ; Infections ; Kidney diseases ; Older people ; Pacemakers ; Patients ; Questioning</subject><ispartof>Curēus (Palo Alto, CA), 2024-08, Vol.16 (8), p.e67003</ispartof><rights>Copyright © 2024, Chu et al.</rights><rights>Copyright © 2024, Chu et al. This work is published under https://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>Copyright © 2024, Chu et al. 2024 Chu et al.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c300t-7fc7c8ac8698a2d66fe7e79e996e71e56e69d7fea45a39da2931b9195b44d4e13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC11403653/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC11403653/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,723,776,780,881,27901,27902,53766,53768</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39286713$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Chu, Man Fong</creatorcontrib><creatorcontrib>Tam, Weng Chio</creatorcontrib><creatorcontrib>Lam, Kuok Wun</creatorcontrib><creatorcontrib>Chan, Chon Hou</creatorcontrib><creatorcontrib>Évora, Màrio</creatorcontrib><creatorcontrib>Lam, U Po</creatorcontrib><title>Utilizing Leadless Pacemakers in Extremely Elderly Patients With a Conventional Pacemaker System: A Two-Year Follow-Up Case Series Without Generator Extraction in High-Risk Scenarios</title><title>Curēus (Palo Alto, CA)</title><addtitle>Cureus</addtitle><description>Background and objectives Leadless pacemakers, known for their safer clinical profile, offer significant advantages for elderly patients at a higher risk of complications associated with transvenous pacemaker procedures, particularly those susceptible to high-risk bleeding and infections related to cardiac implantable electronic device interventions. This study explores an alternative use of leadless pacemakers without removing existing transvenous systems, deviating from conventional generator replacement and lead re-interventions. Methods This study was conducted with full approval from the Institutional Review Board, Medical Ethical Committee, Centro Hospitalar Conde São Januário, Macau. Between January 2018 and December 2021, we conducted a retrospective case series involving extremely elderly individuals (aged 85 years or older) at a high risk of complications, necessitating either generator replacement or lead re-implantation. The study considered implanting a leadless pacemaker (Micra; Medtronic, Minneapolis, MN, USA) without removing the transvenous generator. For the primary endpoints, we evaluated procedure-related complications and clinical outcomes during hospitalization. Secondary endpoints included the stability of parameters and any unexpected interference or interactions between the two systems during the two-year follow-up. Results Eleven patients (aged 86-101) were enrolled, most receiving antiplatelet or anticoagulation therapy. Leadless pacemaker implantation proceeded without major complications or adverse clinical outcomes during hospitalization. Regular follow-up was conducted every three to six months for adjusting pacemaker parameters and interrogating each patient. Over two years, three patients died from non-cardiac causes: two from infection and one from spontaneous intracranial hemorrhage, while eight completed regular follow-ups. We didn't detect any episodes of ventricular arrhythmias or intracardiac capture from the transvenous pacemaker system. We observed the stability in both the longevity and the voltage of the conventional generator battery, maintaining similar parameters without significant depletion (mean voltage decline: -0.07V/year). Parameters of the leadless pacemaker remained consistently normal without interference with existing pacing systems. Conclusion Implanting leadless pacemakers without removing transvenous pacemaker generators appears safe and effective for extremely elderly patients who are at high risk of complications. Comprehensive two-year follow-up supports the safety and viability of this approach. Opting for this approach instead of conventional generator replacement, with or without additional lead implantation, may be reasonable in this population. However, further research within this patient cohort, such as exploring long-term outcomes beyond two years or comparing clinical outcomes with conventional strategies, may be necessary.</description><subject>Body mass index</subject><subject>Cardiac arrhythmia</subject><subject>Cardiology</subject><subject>Cardiovascular disease</subject><subject>Clinical outcomes</subject><subject>Diabetes</subject><subject>Hematoma</subject><subject>Infections</subject><subject>Kidney diseases</subject><subject>Older people</subject><subject>Pacemakers</subject><subject>Patients</subject><subject>Questioning</subject><issn>2168-8184</issn><issn>2168-8184</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>BENPR</sourceid><recordid>eNpdkkFvEzEQhVcIRKvSG2dkiQsHttjrXXvNBVVR2iJFomoaIU7WxDtJ3HrXqe1tCT-M38emaUvhNGP585vn0cuyt4weSVmpT6YP2McjISnlL7L9gok6r1ldvnzW72WHMV5RShmVBZX0dbbHVVELyfh-9nuWrLO_bLckE4TGYYzkHAy2cI0hEtuR8c8UsEW3IWPXYBjqOSSLXYrku00rAmTku9vhbH0H7u9jMt3EhO1nckwu73z-AyGQE--cv8tnazKCiGSKweJOxveJnGKHAZIP9zPBbBW3Ds7scpVf2HhNpgY7CNbHN9mrBbiIhw_1IJudjC9HZ_nk2-nX0fEkN5zSlMuFkaYGUwtVQ9EIsUCJUqFSAiXDSqBQjVwglBVw1UChOJsrpqp5WTYlMn6Qfdnprvt5i80wfjDm9DrYFsJGe7D635vOrvTS32rGSspFxQeFDw8Kwd_0GJNubTToHHTo-6g5o6KspBD1gL7_D73yfRiWuqUY47VkBR2ojzvKBB9jwMWTG0b1NhR6Fwp9H4oBf_f8B0_wYwT4H9aGt28</recordid><startdate>20240816</startdate><enddate>20240816</enddate><creator>Chu, Man Fong</creator><creator>Tam, Weng Chio</creator><creator>Lam, Kuok Wun</creator><creator>Chan, Chon Hou</creator><creator>Évora, Màrio</creator><creator>Lam, U Po</creator><general>Cureus Inc</general><general>Cureus</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20240816</creationdate><title>Utilizing Leadless Pacemakers in Extremely Elderly Patients With a Conventional Pacemaker System: A Two-Year Follow-Up Case Series Without Generator Extraction in High-Risk Scenarios</title><author>Chu, Man Fong ; Tam, Weng Chio ; Lam, Kuok Wun ; Chan, Chon Hou ; Évora, Màrio ; Lam, U Po</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c300t-7fc7c8ac8698a2d66fe7e79e996e71e56e69d7fea45a39da2931b9195b44d4e13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Body mass index</topic><topic>Cardiac arrhythmia</topic><topic>Cardiology</topic><topic>Cardiovascular disease</topic><topic>Clinical outcomes</topic><topic>Diabetes</topic><topic>Hematoma</topic><topic>Infections</topic><topic>Kidney diseases</topic><topic>Older people</topic><topic>Pacemakers</topic><topic>Patients</topic><topic>Questioning</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chu, Man Fong</creatorcontrib><creatorcontrib>Tam, Weng Chio</creatorcontrib><creatorcontrib>Lam, Kuok Wun</creatorcontrib><creatorcontrib>Chan, Chon Hou</creatorcontrib><creatorcontrib>Évora, Màrio</creatorcontrib><creatorcontrib>Lam, U Po</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Curēus (Palo Alto, CA)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chu, Man Fong</au><au>Tam, Weng Chio</au><au>Lam, Kuok Wun</au><au>Chan, Chon Hou</au><au>Évora, Màrio</au><au>Lam, U Po</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Utilizing Leadless Pacemakers in Extremely Elderly Patients With a Conventional Pacemaker System: A Two-Year Follow-Up Case Series Without Generator Extraction in High-Risk Scenarios</atitle><jtitle>Curēus (Palo Alto, CA)</jtitle><addtitle>Cureus</addtitle><date>2024-08-16</date><risdate>2024</risdate><volume>16</volume><issue>8</issue><spage>e67003</spage><pages>e67003-</pages><issn>2168-8184</issn><eissn>2168-8184</eissn><abstract>Background and objectives Leadless pacemakers, known for their safer clinical profile, offer significant advantages for elderly patients at a higher risk of complications associated with transvenous pacemaker procedures, particularly those susceptible to high-risk bleeding and infections related to cardiac implantable electronic device interventions. This study explores an alternative use of leadless pacemakers without removing existing transvenous systems, deviating from conventional generator replacement and lead re-interventions. Methods This study was conducted with full approval from the Institutional Review Board, Medical Ethical Committee, Centro Hospitalar Conde São Januário, Macau. Between January 2018 and December 2021, we conducted a retrospective case series involving extremely elderly individuals (aged 85 years or older) at a high risk of complications, necessitating either generator replacement or lead re-implantation. The study considered implanting a leadless pacemaker (Micra; Medtronic, Minneapolis, MN, USA) without removing the transvenous generator. For the primary endpoints, we evaluated procedure-related complications and clinical outcomes during hospitalization. Secondary endpoints included the stability of parameters and any unexpected interference or interactions between the two systems during the two-year follow-up. Results Eleven patients (aged 86-101) were enrolled, most receiving antiplatelet or anticoagulation therapy. Leadless pacemaker implantation proceeded without major complications or adverse clinical outcomes during hospitalization. Regular follow-up was conducted every three to six months for adjusting pacemaker parameters and interrogating each patient. Over two years, three patients died from non-cardiac causes: two from infection and one from spontaneous intracranial hemorrhage, while eight completed regular follow-ups. We didn't detect any episodes of ventricular arrhythmias or intracardiac capture from the transvenous pacemaker system. We observed the stability in both the longevity and the voltage of the conventional generator battery, maintaining similar parameters without significant depletion (mean voltage decline: -0.07V/year). Parameters of the leadless pacemaker remained consistently normal without interference with existing pacing systems. Conclusion Implanting leadless pacemakers without removing transvenous pacemaker generators appears safe and effective for extremely elderly patients who are at high risk of complications. Comprehensive two-year follow-up supports the safety and viability of this approach. Opting for this approach instead of conventional generator replacement, with or without additional lead implantation, may be reasonable in this population. However, further research within this patient cohort, such as exploring long-term outcomes beyond two years or comparing clinical outcomes with conventional strategies, may be necessary.</abstract><cop>United States</cop><pub>Cureus Inc</pub><pmid>39286713</pmid><doi>10.7759/cureus.67003</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2168-8184
ispartof Curēus (Palo Alto, CA), 2024-08, Vol.16 (8), p.e67003
issn 2168-8184
2168-8184
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11403653
source PubMed Central; PubMed Central Open Access
subjects Body mass index
Cardiac arrhythmia
Cardiology
Cardiovascular disease
Clinical outcomes
Diabetes
Hematoma
Infections
Kidney diseases
Older people
Pacemakers
Patients
Questioning
title Utilizing Leadless Pacemakers in Extremely Elderly Patients With a Conventional Pacemaker System: A Two-Year Follow-Up Case Series Without Generator Extraction in High-Risk Scenarios
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T05%3A22%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Utilizing%20Leadless%20Pacemakers%20in%20Extremely%20Elderly%20Patients%20With%20a%20Conventional%20Pacemaker%20System:%20A%20Two-Year%20Follow-Up%20Case%20Series%20Without%20Generator%20Extraction%20in%20High-Risk%20Scenarios&rft.jtitle=Cur%C4%93us%20(Palo%20Alto,%20CA)&rft.au=Chu,%20Man%20Fong&rft.date=2024-08-16&rft.volume=16&rft.issue=8&rft.spage=e67003&rft.pages=e67003-&rft.issn=2168-8184&rft.eissn=2168-8184&rft_id=info:doi/10.7759/cureus.67003&rft_dat=%3Cproquest_pubme%3E3106457668%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3111387120&rft_id=info:pmid/39286713&rfr_iscdi=true