Bench-Side Dose Accuracy of an Open-Source Ultra-Low-Cost Insulin-Pump, With Testing Conducted to IEC 60601-2-24
With the prevalence of diabetes higher than ever, governments and people with diabetes are facing significant treatment and indirect costs associated with managing their condition. An ultra-low-cost insulin pump is a possible solution to improving health disparities. This article presents test resul...
Gespeichert in:
Veröffentlicht in: | Journal of diabetes science and technology 2024-05, Vol.18 (3), p.709-713 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 713 |
---|---|
container_issue | 3 |
container_start_page | 709 |
container_title | Journal of diabetes science and technology |
container_volume | 18 |
creator | Payne, Matthew Pooke, Francis Holder-Pearson, Lui Chase, J. Geoffrey de Bock, Martin Campbell, Jake Knopp, Jennifer |
description | With the prevalence of diabetes higher than ever, governments and people with diabetes are facing significant treatment and indirect costs associated with managing their condition. An ultra-low-cost insulin pump is a possible solution to improving health disparities. This article presents test results for an insulin-pump built from low-cost components (bill of materials < $US100). All testing was completed in accordance with IEC60601-2-24, and results were benchmarked against a commercial pump. Results showed the ultra-low-cost pump has comparable accuracy to the commercially available insulin pump with testing displaying an overall accuracy of 0.089% and −0.392%, respectively. These results show that an ultra-low-cost pump can accurately deliver insulin in limited bench testing. Testing in other environments and scenarios is required to fully meet IEC60601-2-24 standards. |
doi_str_mv | 10.1177/19322968221142316 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11089868</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_19322968221142316</sage_id><sourcerecordid>2753301321</sourcerecordid><originalsourceid>FETCH-LOGICAL-c439t-cb3fd0d83be80a6b4355af7bae2ec599eaa3edda74c9d1f72573d5f647d9b80d3</originalsourceid><addsrcrecordid>eNp9UU1P3DAQtRCIr_IDeql85FCDP5LYOVU0hXallUACxNFy7MluUNZO4wS0_75eLUUgJE4zmnnz5s08hL4yesaYlOesFJyXheKcsYwLVuygw02NbIq7b_IDdBTjI6V5pqTcRweiyGRBC3WI-p_g7ZLctg7wrxABX1g7DcaucWiw8fi6B09uwzRYwPfdOBgyD8-kCnHEMx-nrvXkZlr13_FDOy7xHcSx9QtcBe8mO4LDY8CzywqnZZSRJCb7gvYa00U4eYnH6P7q8q76Q-bXv2fVxZzYTJQjsbVoHHVK1KCoKepM5LlpZG2Ag83LEowR4JyRmS0dayTPpXB5k-5yZa2oE8fox5a3n-oVOAs-ie90P7QrM6x1MK1-3_HtUi_Ck2aMqlIVKjGcvjAM4e-ULtOrNlroOuMhTFFzmQtBmeAsQdkWaocQ4wDN6x5G9cYq_cGqNPPtrcDXif_eJMDZFhDNAvRj8sCnh33C-A-us5ss</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2753301321</pqid></control><display><type>article</type><title>Bench-Side Dose Accuracy of an Open-Source Ultra-Low-Cost Insulin-Pump, With Testing Conducted to IEC 60601-2-24</title><source>SAGE Complete A-Z List</source><source>MEDLINE</source><creator>Payne, Matthew ; Pooke, Francis ; Holder-Pearson, Lui ; Chase, J. Geoffrey ; de Bock, Martin ; Campbell, Jake ; Knopp, Jennifer</creator><creatorcontrib>Payne, Matthew ; Pooke, Francis ; Holder-Pearson, Lui ; Chase, J. Geoffrey ; de Bock, Martin ; Campbell, Jake ; Knopp, Jennifer</creatorcontrib><description>With the prevalence of diabetes higher than ever, governments and people with diabetes are facing significant treatment and indirect costs associated with managing their condition. An ultra-low-cost insulin pump is a possible solution to improving health disparities. This article presents test results for an insulin-pump built from low-cost components (bill of materials < $US100). All testing was completed in accordance with IEC60601-2-24, and results were benchmarked against a commercial pump. Results showed the ultra-low-cost pump has comparable accuracy to the commercially available insulin pump with testing displaying an overall accuracy of 0.089% and −0.392%, respectively. These results show that an ultra-low-cost pump can accurately deliver insulin in limited bench testing. Testing in other environments and scenarios is required to fully meet IEC60601-2-24 standards.</description><identifier>ISSN: 1932-2968</identifier><identifier>EISSN: 1932-2968</identifier><identifier>EISSN: 1932-3107</identifier><identifier>DOI: 10.1177/19322968221142316</identifier><identifier>PMID: 36476068</identifier><language>eng</language><publisher>Los Angeles, CA: SAGE Publications</publisher><subject>Equipment Design ; Humans ; Hypoglycemic Agents - administration & dosage ; Hypoglycemic Agents - economics ; Insulin - administration & dosage ; Insulin - economics ; Insulin Infusion Systems - economics ; Technology Reports</subject><ispartof>Journal of diabetes science and technology, 2024-05, Vol.18 (3), p.709-713</ispartof><rights>2022 Diabetes Technology Society</rights><rights>2022 Diabetes Technology Society 2022 Diabetes Technology Society</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c439t-cb3fd0d83be80a6b4355af7bae2ec599eaa3edda74c9d1f72573d5f647d9b80d3</citedby><cites>FETCH-LOGICAL-c439t-cb3fd0d83be80a6b4355af7bae2ec599eaa3edda74c9d1f72573d5f647d9b80d3</cites><orcidid>0000-0003-2375-4756 ; 0000-0001-9989-4849 ; 0000-0003-0454-6679 ; 0000-0001-9343-3961</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://journals.sagepub.com/doi/pdf/10.1177/19322968221142316$$EPDF$$P50$$Gsage$$H</linktopdf><linktohtml>$$Uhttps://journals.sagepub.com/doi/10.1177/19322968221142316$$EHTML$$P50$$Gsage$$H</linktohtml><link.rule.ids>230,314,776,780,881,21798,27901,27902,43597,43598</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36476068$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Payne, Matthew</creatorcontrib><creatorcontrib>Pooke, Francis</creatorcontrib><creatorcontrib>Holder-Pearson, Lui</creatorcontrib><creatorcontrib>Chase, J. Geoffrey</creatorcontrib><creatorcontrib>de Bock, Martin</creatorcontrib><creatorcontrib>Campbell, Jake</creatorcontrib><creatorcontrib>Knopp, Jennifer</creatorcontrib><title>Bench-Side Dose Accuracy of an Open-Source Ultra-Low-Cost Insulin-Pump, With Testing Conducted to IEC 60601-2-24</title><title>Journal of diabetes science and technology</title><addtitle>J Diabetes Sci Technol</addtitle><description>With the prevalence of diabetes higher than ever, governments and people with diabetes are facing significant treatment and indirect costs associated with managing their condition. An ultra-low-cost insulin pump is a possible solution to improving health disparities. This article presents test results for an insulin-pump built from low-cost components (bill of materials < $US100). All testing was completed in accordance with IEC60601-2-24, and results were benchmarked against a commercial pump. Results showed the ultra-low-cost pump has comparable accuracy to the commercially available insulin pump with testing displaying an overall accuracy of 0.089% and −0.392%, respectively. These results show that an ultra-low-cost pump can accurately deliver insulin in limited bench testing. Testing in other environments and scenarios is required to fully meet IEC60601-2-24 standards.</description><subject>Equipment Design</subject><subject>Humans</subject><subject>Hypoglycemic Agents - administration & dosage</subject><subject>Hypoglycemic Agents - economics</subject><subject>Insulin - administration & dosage</subject><subject>Insulin - economics</subject><subject>Insulin Infusion Systems - economics</subject><subject>Technology Reports</subject><issn>1932-2968</issn><issn>1932-2968</issn><issn>1932-3107</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9UU1P3DAQtRCIr_IDeql85FCDP5LYOVU0hXallUACxNFy7MluUNZO4wS0_75eLUUgJE4zmnnz5s08hL4yesaYlOesFJyXheKcsYwLVuygw02NbIq7b_IDdBTjI6V5pqTcRweiyGRBC3WI-p_g7ZLctg7wrxABX1g7DcaucWiw8fi6B09uwzRYwPfdOBgyD8-kCnHEMx-nrvXkZlr13_FDOy7xHcSx9QtcBe8mO4LDY8CzywqnZZSRJCb7gvYa00U4eYnH6P7q8q76Q-bXv2fVxZzYTJQjsbVoHHVK1KCoKepM5LlpZG2Ag83LEowR4JyRmS0dayTPpXB5k-5yZa2oE8fox5a3n-oVOAs-ie90P7QrM6x1MK1-3_HtUi_Ck2aMqlIVKjGcvjAM4e-ULtOrNlroOuMhTFFzmQtBmeAsQdkWaocQ4wDN6x5G9cYq_cGqNPPtrcDXif_eJMDZFhDNAvRj8sCnh33C-A-us5ss</recordid><startdate>20240501</startdate><enddate>20240501</enddate><creator>Payne, Matthew</creator><creator>Pooke, Francis</creator><creator>Holder-Pearson, Lui</creator><creator>Chase, J. Geoffrey</creator><creator>de Bock, Martin</creator><creator>Campbell, Jake</creator><creator>Knopp, Jennifer</creator><general>SAGE Publications</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0003-2375-4756</orcidid><orcidid>https://orcid.org/0000-0001-9989-4849</orcidid><orcidid>https://orcid.org/0000-0003-0454-6679</orcidid><orcidid>https://orcid.org/0000-0001-9343-3961</orcidid></search><sort><creationdate>20240501</creationdate><title>Bench-Side Dose Accuracy of an Open-Source Ultra-Low-Cost Insulin-Pump, With Testing Conducted to IEC 60601-2-24</title><author>Payne, Matthew ; Pooke, Francis ; Holder-Pearson, Lui ; Chase, J. Geoffrey ; de Bock, Martin ; Campbell, Jake ; Knopp, Jennifer</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c439t-cb3fd0d83be80a6b4355af7bae2ec599eaa3edda74c9d1f72573d5f647d9b80d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Equipment Design</topic><topic>Humans</topic><topic>Hypoglycemic Agents - administration & dosage</topic><topic>Hypoglycemic Agents - economics</topic><topic>Insulin - administration & dosage</topic><topic>Insulin - economics</topic><topic>Insulin Infusion Systems - economics</topic><topic>Technology Reports</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Payne, Matthew</creatorcontrib><creatorcontrib>Pooke, Francis</creatorcontrib><creatorcontrib>Holder-Pearson, Lui</creatorcontrib><creatorcontrib>Chase, J. Geoffrey</creatorcontrib><creatorcontrib>de Bock, Martin</creatorcontrib><creatorcontrib>Campbell, Jake</creatorcontrib><creatorcontrib>Knopp, Jennifer</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of diabetes science and technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Payne, Matthew</au><au>Pooke, Francis</au><au>Holder-Pearson, Lui</au><au>Chase, J. Geoffrey</au><au>de Bock, Martin</au><au>Campbell, Jake</au><au>Knopp, Jennifer</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Bench-Side Dose Accuracy of an Open-Source Ultra-Low-Cost Insulin-Pump, With Testing Conducted to IEC 60601-2-24</atitle><jtitle>Journal of diabetes science and technology</jtitle><addtitle>J Diabetes Sci Technol</addtitle><date>2024-05-01</date><risdate>2024</risdate><volume>18</volume><issue>3</issue><spage>709</spage><epage>713</epage><pages>709-713</pages><issn>1932-2968</issn><eissn>1932-2968</eissn><eissn>1932-3107</eissn><abstract>With the prevalence of diabetes higher than ever, governments and people with diabetes are facing significant treatment and indirect costs associated with managing their condition. An ultra-low-cost insulin pump is a possible solution to improving health disparities. This article presents test results for an insulin-pump built from low-cost components (bill of materials < $US100). All testing was completed in accordance with IEC60601-2-24, and results were benchmarked against a commercial pump. Results showed the ultra-low-cost pump has comparable accuracy to the commercially available insulin pump with testing displaying an overall accuracy of 0.089% and −0.392%, respectively. These results show that an ultra-low-cost pump can accurately deliver insulin in limited bench testing. Testing in other environments and scenarios is required to fully meet IEC60601-2-24 standards.</abstract><cop>Los Angeles, CA</cop><pub>SAGE Publications</pub><pmid>36476068</pmid><doi>10.1177/19322968221142316</doi><tpages>5</tpages><orcidid>https://orcid.org/0000-0003-2375-4756</orcidid><orcidid>https://orcid.org/0000-0001-9989-4849</orcidid><orcidid>https://orcid.org/0000-0003-0454-6679</orcidid><orcidid>https://orcid.org/0000-0001-9343-3961</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1932-2968 |
ispartof | Journal of diabetes science and technology, 2024-05, Vol.18 (3), p.709-713 |
issn | 1932-2968 1932-2968 1932-3107 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11089868 |
source | SAGE Complete A-Z List; MEDLINE |
subjects | Equipment Design Humans Hypoglycemic Agents - administration & dosage Hypoglycemic Agents - economics Insulin - administration & dosage Insulin - economics Insulin Infusion Systems - economics Technology Reports |
title | Bench-Side Dose Accuracy of an Open-Source Ultra-Low-Cost Insulin-Pump, With Testing Conducted to IEC 60601-2-24 |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T02%3A27%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Bench-Side%20Dose%20Accuracy%20of%20an%20Open-Source%20Ultra-Low-Cost%20Insulin-Pump,%20With%20Testing%20Conducted%20to%20IEC%2060601-2-24&rft.jtitle=Journal%20of%20diabetes%20science%20and%20technology&rft.au=Payne,%20Matthew&rft.date=2024-05-01&rft.volume=18&rft.issue=3&rft.spage=709&rft.epage=713&rft.pages=709-713&rft.issn=1932-2968&rft.eissn=1932-2968&rft_id=info:doi/10.1177/19322968221142316&rft_dat=%3Cproquest_pubme%3E2753301321%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2753301321&rft_id=info:pmid/36476068&rft_sage_id=10.1177_19322968221142316&rfr_iscdi=true |