Parameters That Can Be Used to Quantify Reduction Accuracy in Talar Neck Fractures and Malunions: A PRISMA-Compliant Scoping Review and Meta-Analysis
Understanding the three-dimensional anatomy of the talar neck is essential in assessing the accuracy of reduction in talar neck fractures as well as for planning surgical correction for talar malunions. However, the geometrical parameters that describe this anatomy are sparsely reported in the ortho...
Gespeichert in:
Veröffentlicht in: | Curēus (Palo Alto, CA) CA), 2024-04, Vol.16 (4), p.e58161-e58161 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | e58161 |
---|---|
container_issue | 4 |
container_start_page | e58161 |
container_title | Curēus (Palo Alto, CA) |
container_volume | 16 |
creator | Sharma, Siddhartha Jindal, Karan Patel, Sandeep Prabhkar, Sharad Prakash, Mahesh Rammelt, Stefan Dhillon, Mandeep |
description | Understanding the three-dimensional anatomy of the talar neck is essential in assessing the accuracy of reduction in talar neck fractures as well as for planning surgical correction for talar malunions. However, the geometrical parameters that describe this anatomy are sparsely reported in the orthopedics literature. We aimed to identify from the existing literature, geometrical parameters that describe the anatomy of the talar neck, determine how these are measured, and their normative values. A scoping literature review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) extension for scoping reviews (PRISMA-ScR) guidelines. The primary searches were conducted on the PubMed, Embase, and Scopus databases. Any original research study looking at the human talus neck geometry was included. Parameters that described the anatomy of the talar neck were identified, and pooled estimates were determined by the random-effects meta-analysis model. Heterogeneity was assessed by the
test and leave-one-out meta-analysis. Subgroup analysis was done to compare the values of parameters between the Asian and Non-Asian populations. The risk of bias was assessed by the National Institutes of Health (NIH) Case Series Tool. The combined searches yielded 6326 results, of which 21 studies were included in the review and 15 in six different sets of metanalysis. The majority of the studies (n=19, 90.5%) evaluated adult tali, and only two (9.5%) evaluated pediatric tali. In most of the studies (n=13, 61.9%), talus neck geometry was evaluated on dry bones or anatomical specimens; evaluation by imaging techniques (radiographs, CT, MRI, and radiostereometric analysis) was used in eight studies, (39.1%). A total of eight different geometrical parameters (neck length, height, width, declination angle, inclination angle, torsion angle, circumference, and cross-sectional area) were identified. Except for talar torsion, variability was noted in methods of measurement of all other parameters. Subgroup analysis revealed that Asians had a higher neck height as compared to non-Asians; other parameters were not significantly different. Although the literature reports geometrical parameters to assess the talar geometry, the methods of measurement of these parameters are variable. Most of the available literature describes measurement techniques on cadaveric tali, and there is no literature on how these parameters should be measured on |
doi_str_mv | 10.7759/cureus.58161 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11089339</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3054839017</sourcerecordid><originalsourceid>FETCH-LOGICAL-c300t-689d0f66693f686712eeb62c585435b271cd4b667150ffe2593dbfa038066f413</originalsourceid><addsrcrecordid>eNpdkU1PFTEUhidGIgTYuTZN3LhwoJ3OdDpuzHgjSgKKcFk3nc4pFGfaSz8w94f4fy1cJGjSpE3P06fn5C2K1wQftG3THarkIYWDhhNGXhQ7FWG85ITXL5-dt4v9EG4wxgS3FW7xq2Kb8rYmvO12it9n0ssZIviAltcyooW06BOgywAjig79SNJGo9foHMakonEW9Sr_KtUaGYuWcpIefQP1Ex3lu5jbCUjaEZ3KKdlMhw-oR2fnxxenfblw82oy2YculFsZe5WldwZ-bR5AlGVv5bQOJuwVW1pOAfYf993i8ujzcvG1PPn-5XjRn5SKYhxLxrsRa8ZYRzXjrCUVwMAq1fCmps1QtUSN9cByocFaQ9V0dBy0xJRjxnRN6G7xceNdpWGGUYGNXk5i5c0s_Vo4acS_FWuuxZW7E4Rg3lHaZcO7R4N3twlCFLMJCqZJWnApCIqbmtMOkzajb_9Db1zyeeJ7ilW8pnll6v2GUt6F4EE_dUOwuM9cbDIXD5ln_M3zCZ7gvwnTP1geqJE</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3062843843</pqid></control><display><type>article</type><title>Parameters That Can Be Used to Quantify Reduction Accuracy in Talar Neck Fractures and Malunions: A PRISMA-Compliant Scoping Review and Meta-Analysis</title><source>PubMed Central</source><source>PubMed Central Open Access</source><creator>Sharma, Siddhartha ; Jindal, Karan ; Patel, Sandeep ; Prabhkar, Sharad ; Prakash, Mahesh ; Rammelt, Stefan ; Dhillon, Mandeep</creator><creatorcontrib>Sharma, Siddhartha ; Jindal, Karan ; Patel, Sandeep ; Prabhkar, Sharad ; Prakash, Mahesh ; Rammelt, Stefan ; Dhillon, Mandeep</creatorcontrib><description>Understanding the three-dimensional anatomy of the talar neck is essential in assessing the accuracy of reduction in talar neck fractures as well as for planning surgical correction for talar malunions. However, the geometrical parameters that describe this anatomy are sparsely reported in the orthopedics literature. We aimed to identify from the existing literature, geometrical parameters that describe the anatomy of the talar neck, determine how these are measured, and their normative values. A scoping literature review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) extension for scoping reviews (PRISMA-ScR) guidelines. The primary searches were conducted on the PubMed, Embase, and Scopus databases. Any original research study looking at the human talus neck geometry was included. Parameters that described the anatomy of the talar neck were identified, and pooled estimates were determined by the random-effects meta-analysis model. Heterogeneity was assessed by the
test and leave-one-out meta-analysis. Subgroup analysis was done to compare the values of parameters between the Asian and Non-Asian populations. The risk of bias was assessed by the National Institutes of Health (NIH) Case Series Tool. The combined searches yielded 6326 results, of which 21 studies were included in the review and 15 in six different sets of metanalysis. The majority of the studies (n=19, 90.5%) evaluated adult tali, and only two (9.5%) evaluated pediatric tali. In most of the studies (n=13, 61.9%), talus neck geometry was evaluated on dry bones or anatomical specimens; evaluation by imaging techniques (radiographs, CT, MRI, and radiostereometric analysis) was used in eight studies, (39.1%). A total of eight different geometrical parameters (neck length, height, width, declination angle, inclination angle, torsion angle, circumference, and cross-sectional area) were identified. Except for talar torsion, variability was noted in methods of measurement of all other parameters. Subgroup analysis revealed that Asians had a higher neck height as compared to non-Asians; other parameters were not significantly different. Although the literature reports geometrical parameters to assess the talar geometry, the methods of measurement of these parameters are variable. Most of the available literature describes measurement techniques on cadaveric tali, and there is no literature on how these parameters should be measured on conventional CT or MRI slices. Further research needs to focus on the standardization of measurement techniques for these parameters on conventional CT and/or MRI scans.</description><identifier>ISSN: 2168-8184</identifier><identifier>EISSN: 2168-8184</identifier><identifier>DOI: 10.7759/cureus.58161</identifier><identifier>PMID: 38741879</identifier><language>eng</language><publisher>United States: Cureus Inc</publisher><subject>Anatomy ; Biometrics ; Citation management software ; Fractures ; Geometry ; Measurement techniques ; Meta-analysis ; Morphology ; Neck ; Orthopedics ; Trauma</subject><ispartof>Curēus (Palo Alto, CA), 2024-04, Vol.16 (4), p.e58161-e58161</ispartof><rights>Copyright © 2024, Sharma et al.</rights><rights>Copyright © 2024, Sharma et al. This work is published under https://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>Copyright © 2024, Sharma et al. 2024 Sharma et al.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c300t-689d0f66693f686712eeb62c585435b271cd4b667150ffe2593dbfa038066f413</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC11089339/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC11089339/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,723,776,780,881,27903,27904,53769,53771</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38741879$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sharma, Siddhartha</creatorcontrib><creatorcontrib>Jindal, Karan</creatorcontrib><creatorcontrib>Patel, Sandeep</creatorcontrib><creatorcontrib>Prabhkar, Sharad</creatorcontrib><creatorcontrib>Prakash, Mahesh</creatorcontrib><creatorcontrib>Rammelt, Stefan</creatorcontrib><creatorcontrib>Dhillon, Mandeep</creatorcontrib><title>Parameters That Can Be Used to Quantify Reduction Accuracy in Talar Neck Fractures and Malunions: A PRISMA-Compliant Scoping Review and Meta-Analysis</title><title>Curēus (Palo Alto, CA)</title><addtitle>Cureus</addtitle><description>Understanding the three-dimensional anatomy of the talar neck is essential in assessing the accuracy of reduction in talar neck fractures as well as for planning surgical correction for talar malunions. However, the geometrical parameters that describe this anatomy are sparsely reported in the orthopedics literature. We aimed to identify from the existing literature, geometrical parameters that describe the anatomy of the talar neck, determine how these are measured, and their normative values. A scoping literature review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) extension for scoping reviews (PRISMA-ScR) guidelines. The primary searches were conducted on the PubMed, Embase, and Scopus databases. Any original research study looking at the human talus neck geometry was included. Parameters that described the anatomy of the talar neck were identified, and pooled estimates were determined by the random-effects meta-analysis model. Heterogeneity was assessed by the
test and leave-one-out meta-analysis. Subgroup analysis was done to compare the values of parameters between the Asian and Non-Asian populations. The risk of bias was assessed by the National Institutes of Health (NIH) Case Series Tool. The combined searches yielded 6326 results, of which 21 studies were included in the review and 15 in six different sets of metanalysis. The majority of the studies (n=19, 90.5%) evaluated adult tali, and only two (9.5%) evaluated pediatric tali. In most of the studies (n=13, 61.9%), talus neck geometry was evaluated on dry bones or anatomical specimens; evaluation by imaging techniques (radiographs, CT, MRI, and radiostereometric analysis) was used in eight studies, (39.1%). A total of eight different geometrical parameters (neck length, height, width, declination angle, inclination angle, torsion angle, circumference, and cross-sectional area) were identified. Except for talar torsion, variability was noted in methods of measurement of all other parameters. Subgroup analysis revealed that Asians had a higher neck height as compared to non-Asians; other parameters were not significantly different. Although the literature reports geometrical parameters to assess the talar geometry, the methods of measurement of these parameters are variable. Most of the available literature describes measurement techniques on cadaveric tali, and there is no literature on how these parameters should be measured on conventional CT or MRI slices. Further research needs to focus on the standardization of measurement techniques for these parameters on conventional CT and/or MRI scans.</description><subject>Anatomy</subject><subject>Biometrics</subject><subject>Citation management software</subject><subject>Fractures</subject><subject>Geometry</subject><subject>Measurement techniques</subject><subject>Meta-analysis</subject><subject>Morphology</subject><subject>Neck</subject><subject>Orthopedics</subject><subject>Trauma</subject><issn>2168-8184</issn><issn>2168-8184</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>BENPR</sourceid><recordid>eNpdkU1PFTEUhidGIgTYuTZN3LhwoJ3OdDpuzHgjSgKKcFk3nc4pFGfaSz8w94f4fy1cJGjSpE3P06fn5C2K1wQftG3THarkIYWDhhNGXhQ7FWG85ITXL5-dt4v9EG4wxgS3FW7xq2Kb8rYmvO12it9n0ssZIviAltcyooW06BOgywAjig79SNJGo9foHMakonEW9Sr_KtUaGYuWcpIefQP1Ex3lu5jbCUjaEZ3KKdlMhw-oR2fnxxenfblw82oy2YculFsZe5WldwZ-bR5AlGVv5bQOJuwVW1pOAfYf993i8ujzcvG1PPn-5XjRn5SKYhxLxrsRa8ZYRzXjrCUVwMAq1fCmps1QtUSN9cByocFaQ9V0dBy0xJRjxnRN6G7xceNdpWGGUYGNXk5i5c0s_Vo4acS_FWuuxZW7E4Rg3lHaZcO7R4N3twlCFLMJCqZJWnApCIqbmtMOkzajb_9Db1zyeeJ7ilW8pnll6v2GUt6F4EE_dUOwuM9cbDIXD5ln_M3zCZ7gvwnTP1geqJE</recordid><startdate>20240413</startdate><enddate>20240413</enddate><creator>Sharma, Siddhartha</creator><creator>Jindal, Karan</creator><creator>Patel, Sandeep</creator><creator>Prabhkar, Sharad</creator><creator>Prakash, Mahesh</creator><creator>Rammelt, Stefan</creator><creator>Dhillon, Mandeep</creator><general>Cureus Inc</general><general>Cureus</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20240413</creationdate><title>Parameters That Can Be Used to Quantify Reduction Accuracy in Talar Neck Fractures and Malunions: A PRISMA-Compliant Scoping Review and Meta-Analysis</title><author>Sharma, Siddhartha ; Jindal, Karan ; Patel, Sandeep ; Prabhkar, Sharad ; Prakash, Mahesh ; Rammelt, Stefan ; Dhillon, Mandeep</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c300t-689d0f66693f686712eeb62c585435b271cd4b667150ffe2593dbfa038066f413</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Anatomy</topic><topic>Biometrics</topic><topic>Citation management software</topic><topic>Fractures</topic><topic>Geometry</topic><topic>Measurement techniques</topic><topic>Meta-analysis</topic><topic>Morphology</topic><topic>Neck</topic><topic>Orthopedics</topic><topic>Trauma</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sharma, Siddhartha</creatorcontrib><creatorcontrib>Jindal, Karan</creatorcontrib><creatorcontrib>Patel, Sandeep</creatorcontrib><creatorcontrib>Prabhkar, Sharad</creatorcontrib><creatorcontrib>Prakash, Mahesh</creatorcontrib><creatorcontrib>Rammelt, Stefan</creatorcontrib><creatorcontrib>Dhillon, Mandeep</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Curēus (Palo Alto, CA)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sharma, Siddhartha</au><au>Jindal, Karan</au><au>Patel, Sandeep</au><au>Prabhkar, Sharad</au><au>Prakash, Mahesh</au><au>Rammelt, Stefan</au><au>Dhillon, Mandeep</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Parameters That Can Be Used to Quantify Reduction Accuracy in Talar Neck Fractures and Malunions: A PRISMA-Compliant Scoping Review and Meta-Analysis</atitle><jtitle>Curēus (Palo Alto, CA)</jtitle><addtitle>Cureus</addtitle><date>2024-04-13</date><risdate>2024</risdate><volume>16</volume><issue>4</issue><spage>e58161</spage><epage>e58161</epage><pages>e58161-e58161</pages><issn>2168-8184</issn><eissn>2168-8184</eissn><abstract>Understanding the three-dimensional anatomy of the talar neck is essential in assessing the accuracy of reduction in talar neck fractures as well as for planning surgical correction for talar malunions. However, the geometrical parameters that describe this anatomy are sparsely reported in the orthopedics literature. We aimed to identify from the existing literature, geometrical parameters that describe the anatomy of the talar neck, determine how these are measured, and their normative values. A scoping literature review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) extension for scoping reviews (PRISMA-ScR) guidelines. The primary searches were conducted on the PubMed, Embase, and Scopus databases. Any original research study looking at the human talus neck geometry was included. Parameters that described the anatomy of the talar neck were identified, and pooled estimates were determined by the random-effects meta-analysis model. Heterogeneity was assessed by the
test and leave-one-out meta-analysis. Subgroup analysis was done to compare the values of parameters between the Asian and Non-Asian populations. The risk of bias was assessed by the National Institutes of Health (NIH) Case Series Tool. The combined searches yielded 6326 results, of which 21 studies were included in the review and 15 in six different sets of metanalysis. The majority of the studies (n=19, 90.5%) evaluated adult tali, and only two (9.5%) evaluated pediatric tali. In most of the studies (n=13, 61.9%), talus neck geometry was evaluated on dry bones or anatomical specimens; evaluation by imaging techniques (radiographs, CT, MRI, and radiostereometric analysis) was used in eight studies, (39.1%). A total of eight different geometrical parameters (neck length, height, width, declination angle, inclination angle, torsion angle, circumference, and cross-sectional area) were identified. Except for talar torsion, variability was noted in methods of measurement of all other parameters. Subgroup analysis revealed that Asians had a higher neck height as compared to non-Asians; other parameters were not significantly different. Although the literature reports geometrical parameters to assess the talar geometry, the methods of measurement of these parameters are variable. Most of the available literature describes measurement techniques on cadaveric tali, and there is no literature on how these parameters should be measured on conventional CT or MRI slices. Further research needs to focus on the standardization of measurement techniques for these parameters on conventional CT and/or MRI scans.</abstract><cop>United States</cop><pub>Cureus Inc</pub><pmid>38741879</pmid><doi>10.7759/cureus.58161</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2168-8184 |
ispartof | Curēus (Palo Alto, CA), 2024-04, Vol.16 (4), p.e58161-e58161 |
issn | 2168-8184 2168-8184 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11089339 |
source | PubMed Central; PubMed Central Open Access |
subjects | Anatomy Biometrics Citation management software Fractures Geometry Measurement techniques Meta-analysis Morphology Neck Orthopedics Trauma |
title | Parameters That Can Be Used to Quantify Reduction Accuracy in Talar Neck Fractures and Malunions: A PRISMA-Compliant Scoping Review and Meta-Analysis |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T19%3A42%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Parameters%20That%20Can%20Be%20Used%20to%20Quantify%20Reduction%20Accuracy%20in%20Talar%20Neck%20Fractures%20and%20Malunions:%20A%20PRISMA-Compliant%20Scoping%20Review%20and%20Meta-Analysis&rft.jtitle=Cur%C4%93us%20(Palo%20Alto,%20CA)&rft.au=Sharma,%20Siddhartha&rft.date=2024-04-13&rft.volume=16&rft.issue=4&rft.spage=e58161&rft.epage=e58161&rft.pages=e58161-e58161&rft.issn=2168-8184&rft.eissn=2168-8184&rft_id=info:doi/10.7759/cureus.58161&rft_dat=%3Cproquest_pubme%3E3054839017%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3062843843&rft_id=info:pmid/38741879&rfr_iscdi=true |