MIRD Pamphlet No. 29: MIRDy90-A 90Y Research Microsphere Dosimetry Tool

90Y-microsphere radioembolization has become a well-established treatment option for liver malignancies and is one of the first U.S. Food and Drug Administration–approved unsealed radionuclide brachytherapy devices to incorporate dosimetry-based treatment planning. Several different mathematical mod...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of nuclear medicine (1978) 2024-05, Vol.65 (5), p.1-802
Hauptverfasser: Marquis, Harry, Ramos, Juan C Ocampo, Carter, Lukas M, Zanzonico, Pat, Bolch, Wesley E, Laforest, Richard, Kesner, Adam L
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 802
container_issue 5
container_start_page 1
container_title The Journal of nuclear medicine (1978)
container_volume 65
creator Marquis, Harry
Ramos, Juan C Ocampo
Carter, Lukas M
Zanzonico, Pat
Bolch, Wesley E
Laforest, Richard
Kesner, Adam L
description 90Y-microsphere radioembolization has become a well-established treatment option for liver malignancies and is one of the first U.S. Food and Drug Administration–approved unsealed radionuclide brachytherapy devices to incorporate dosimetry-based treatment planning. Several different mathematical models are used to calculate the patient-specific prescribed activity of 90Y, namely, body surface area (SIR-Spheres only), MIRD single compartment, and MIRD dual compartment (partition). Under the auspices of the MIRDsoft initiative to develop community dosimetry software and tools, the body surface area, MIRD single-compartment, MIRD dual-compartment, and MIRD multicompartment models have been integrated into a MIRDy90 software worksheet. The worksheet was built in MS Excel to estimate and compare prescribed activities calculated via these respective models. The MIRDy90 software was validated against available tools for calculating 90Y prescribed activity. The results of MIRDy90 calculations were compared with those obtained from vendor and community-developed tools, and the calculations agreed well. The MIRDy90 worksheet was developed to provide a vetted tool to better evaluate patient-specific prescribed activities calculated via different models, as well as model influences with respect to varying input parameters. MIRDy90 allows users to interact and visualize the results of various parameter combinations. Variables, equations, and calculations are described in the MIRDy90 documentation and articulated in the MIRDy90 worksheet. The worksheet is distributed as a free tool to build expertise within the medical physics community and create a vetted standard for model and variable management.
doi_str_mv 10.2967/jnumed.123.266743
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11064830</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3050942929</sourcerecordid><originalsourceid>FETCH-LOGICAL-p272t-1137677bf53b527e6e5e8f7264898d0bb1a864c5ac3e57885be1b677d2a056003</originalsourceid><addsrcrecordid>eNpdkE1PwkAQhjdGI4j-AG-bePHSuh_dj3oxBBRJQA3Bg6dmWwZb0nbrbmvCv7dELnqazMwz78w7CF1TErJYqrtd3VWwCSnjIZNSRfwEDangIhB9doqGhEoaCEHEAF14vyOESK31ORpwzbUWNBqi2XK-muI3UzV5CS1-sSFm8T0-VPcxCcY4Jh94BR6My3K8LDJnfZODAzy1vqigdXu8tra8RGdbU3q4OsYRen96XE-eg8XrbD4ZL4KGKdYGlHIllUq3gqeCKZAgQG8Vk5GO9YakKTVaRpkwGQeh-htToGk_sGGGCEkIH6GHX92mS3vvGdStM2XSuKIybp9YUyR_O3WRJ5_2O6GU9Ev4QeH2qODsVwe-TarCZ1CWpgbb-YQTQeKIxSzu0Zt_6M52ru79HSgqNO8fyX8A2_hyOA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3051583383</pqid></control><display><type>article</type><title>MIRD Pamphlet No. 29: MIRDy90-A 90Y Research Microsphere Dosimetry Tool</title><source>EZB-FREE-00999 freely available EZB journals</source><source>Alma/SFX Local Collection</source><creator>Marquis, Harry ; Ramos, Juan C Ocampo ; Carter, Lukas M ; Zanzonico, Pat ; Bolch, Wesley E ; Laforest, Richard ; Kesner, Adam L</creator><creatorcontrib>Marquis, Harry ; Ramos, Juan C Ocampo ; Carter, Lukas M ; Zanzonico, Pat ; Bolch, Wesley E ; Laforest, Richard ; Kesner, Adam L</creatorcontrib><description>90Y-microsphere radioembolization has become a well-established treatment option for liver malignancies and is one of the first U.S. Food and Drug Administration–approved unsealed radionuclide brachytherapy devices to incorporate dosimetry-based treatment planning. Several different mathematical models are used to calculate the patient-specific prescribed activity of 90Y, namely, body surface area (SIR-Spheres only), MIRD single compartment, and MIRD dual compartment (partition). Under the auspices of the MIRDsoft initiative to develop community dosimetry software and tools, the body surface area, MIRD single-compartment, MIRD dual-compartment, and MIRD multicompartment models have been integrated into a MIRDy90 software worksheet. The worksheet was built in MS Excel to estimate and compare prescribed activities calculated via these respective models. The MIRDy90 software was validated against available tools for calculating 90Y prescribed activity. The results of MIRDy90 calculations were compared with those obtained from vendor and community-developed tools, and the calculations agreed well. The MIRDy90 worksheet was developed to provide a vetted tool to better evaluate patient-specific prescribed activities calculated via different models, as well as model influences with respect to varying input parameters. MIRDy90 allows users to interact and visualize the results of various parameter combinations. Variables, equations, and calculations are described in the MIRDy90 documentation and articulated in the MIRDy90 worksheet. The worksheet is distributed as a free tool to build expertise within the medical physics community and create a vetted standard for model and variable management.</description><identifier>ISSN: 0161-5505</identifier><identifier>ISSN: 1535-5667</identifier><identifier>EISSN: 1535-5667</identifier><identifier>DOI: 10.2967/jnumed.123.266743</identifier><identifier>PMID: 38388514</identifier><language>eng</language><publisher>New York: Society of Nuclear Medicine</publisher><subject>Basic Science Investigation ; Brachytherapy ; Dosimeters ; Dosimetry ; Malignancy ; Mathematical models ; Parameters ; Patients ; Radiation therapy ; Radioisotopes ; Software ; Surface area ; Yttrium isotopes</subject><ispartof>The Journal of nuclear medicine (1978), 2024-05, Vol.65 (5), p.1-802</ispartof><rights>Copyright Society of Nuclear Medicine May 1, 2024</rights><rights>2024 by the Society of Nuclear Medicine and Molecular Imaging.</rights><rights>2024 by the Society of Nuclear Medicine and Molecular Imaging. 2024</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27924,27925</link.rule.ids></links><search><creatorcontrib>Marquis, Harry</creatorcontrib><creatorcontrib>Ramos, Juan C Ocampo</creatorcontrib><creatorcontrib>Carter, Lukas M</creatorcontrib><creatorcontrib>Zanzonico, Pat</creatorcontrib><creatorcontrib>Bolch, Wesley E</creatorcontrib><creatorcontrib>Laforest, Richard</creatorcontrib><creatorcontrib>Kesner, Adam L</creatorcontrib><title>MIRD Pamphlet No. 29: MIRDy90-A 90Y Research Microsphere Dosimetry Tool</title><title>The Journal of nuclear medicine (1978)</title><description>90Y-microsphere radioembolization has become a well-established treatment option for liver malignancies and is one of the first U.S. Food and Drug Administration–approved unsealed radionuclide brachytherapy devices to incorporate dosimetry-based treatment planning. Several different mathematical models are used to calculate the patient-specific prescribed activity of 90Y, namely, body surface area (SIR-Spheres only), MIRD single compartment, and MIRD dual compartment (partition). Under the auspices of the MIRDsoft initiative to develop community dosimetry software and tools, the body surface area, MIRD single-compartment, MIRD dual-compartment, and MIRD multicompartment models have been integrated into a MIRDy90 software worksheet. The worksheet was built in MS Excel to estimate and compare prescribed activities calculated via these respective models. The MIRDy90 software was validated against available tools for calculating 90Y prescribed activity. The results of MIRDy90 calculations were compared with those obtained from vendor and community-developed tools, and the calculations agreed well. The MIRDy90 worksheet was developed to provide a vetted tool to better evaluate patient-specific prescribed activities calculated via different models, as well as model influences with respect to varying input parameters. MIRDy90 allows users to interact and visualize the results of various parameter combinations. Variables, equations, and calculations are described in the MIRDy90 documentation and articulated in the MIRDy90 worksheet. The worksheet is distributed as a free tool to build expertise within the medical physics community and create a vetted standard for model and variable management.</description><subject>Basic Science Investigation</subject><subject>Brachytherapy</subject><subject>Dosimeters</subject><subject>Dosimetry</subject><subject>Malignancy</subject><subject>Mathematical models</subject><subject>Parameters</subject><subject>Patients</subject><subject>Radiation therapy</subject><subject>Radioisotopes</subject><subject>Software</subject><subject>Surface area</subject><subject>Yttrium isotopes</subject><issn>0161-5505</issn><issn>1535-5667</issn><issn>1535-5667</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNpdkE1PwkAQhjdGI4j-AG-bePHSuh_dj3oxBBRJQA3Bg6dmWwZb0nbrbmvCv7dELnqazMwz78w7CF1TErJYqrtd3VWwCSnjIZNSRfwEDangIhB9doqGhEoaCEHEAF14vyOESK31ORpwzbUWNBqi2XK-muI3UzV5CS1-sSFm8T0-VPcxCcY4Jh94BR6My3K8LDJnfZODAzy1vqigdXu8tra8RGdbU3q4OsYRen96XE-eg8XrbD4ZL4KGKdYGlHIllUq3gqeCKZAgQG8Vk5GO9YakKTVaRpkwGQeh-htToGk_sGGGCEkIH6GHX92mS3vvGdStM2XSuKIybp9YUyR_O3WRJ5_2O6GU9Ev4QeH2qODsVwe-TarCZ1CWpgbb-YQTQeKIxSzu0Zt_6M52ru79HSgqNO8fyX8A2_hyOA</recordid><startdate>20240501</startdate><enddate>20240501</enddate><creator>Marquis, Harry</creator><creator>Ramos, Juan C Ocampo</creator><creator>Carter, Lukas M</creator><creator>Zanzonico, Pat</creator><creator>Bolch, Wesley E</creator><creator>Laforest, Richard</creator><creator>Kesner, Adam L</creator><general>Society of Nuclear Medicine</general><scope>4T-</scope><scope>8FD</scope><scope>FR3</scope><scope>K9.</scope><scope>M7Z</scope><scope>NAPCQ</scope><scope>P64</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20240501</creationdate><title>MIRD Pamphlet No. 29: MIRDy90-A 90Y Research Microsphere Dosimetry Tool</title><author>Marquis, Harry ; Ramos, Juan C Ocampo ; Carter, Lukas M ; Zanzonico, Pat ; Bolch, Wesley E ; Laforest, Richard ; Kesner, Adam L</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p272t-1137677bf53b527e6e5e8f7264898d0bb1a864c5ac3e57885be1b677d2a056003</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Basic Science Investigation</topic><topic>Brachytherapy</topic><topic>Dosimeters</topic><topic>Dosimetry</topic><topic>Malignancy</topic><topic>Mathematical models</topic><topic>Parameters</topic><topic>Patients</topic><topic>Radiation therapy</topic><topic>Radioisotopes</topic><topic>Software</topic><topic>Surface area</topic><topic>Yttrium isotopes</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Marquis, Harry</creatorcontrib><creatorcontrib>Ramos, Juan C Ocampo</creatorcontrib><creatorcontrib>Carter, Lukas M</creatorcontrib><creatorcontrib>Zanzonico, Pat</creatorcontrib><creatorcontrib>Bolch, Wesley E</creatorcontrib><creatorcontrib>Laforest, Richard</creatorcontrib><creatorcontrib>Kesner, Adam L</creatorcontrib><collection>Docstoc</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Biochemistry Abstracts 1</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>The Journal of nuclear medicine (1978)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Marquis, Harry</au><au>Ramos, Juan C Ocampo</au><au>Carter, Lukas M</au><au>Zanzonico, Pat</au><au>Bolch, Wesley E</au><au>Laforest, Richard</au><au>Kesner, Adam L</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>MIRD Pamphlet No. 29: MIRDy90-A 90Y Research Microsphere Dosimetry Tool</atitle><jtitle>The Journal of nuclear medicine (1978)</jtitle><date>2024-05-01</date><risdate>2024</risdate><volume>65</volume><issue>5</issue><spage>1</spage><epage>802</epage><pages>1-802</pages><issn>0161-5505</issn><issn>1535-5667</issn><eissn>1535-5667</eissn><abstract>90Y-microsphere radioembolization has become a well-established treatment option for liver malignancies and is one of the first U.S. Food and Drug Administration–approved unsealed radionuclide brachytherapy devices to incorporate dosimetry-based treatment planning. Several different mathematical models are used to calculate the patient-specific prescribed activity of 90Y, namely, body surface area (SIR-Spheres only), MIRD single compartment, and MIRD dual compartment (partition). Under the auspices of the MIRDsoft initiative to develop community dosimetry software and tools, the body surface area, MIRD single-compartment, MIRD dual-compartment, and MIRD multicompartment models have been integrated into a MIRDy90 software worksheet. The worksheet was built in MS Excel to estimate and compare prescribed activities calculated via these respective models. The MIRDy90 software was validated against available tools for calculating 90Y prescribed activity. The results of MIRDy90 calculations were compared with those obtained from vendor and community-developed tools, and the calculations agreed well. The MIRDy90 worksheet was developed to provide a vetted tool to better evaluate patient-specific prescribed activities calculated via different models, as well as model influences with respect to varying input parameters. MIRDy90 allows users to interact and visualize the results of various parameter combinations. Variables, equations, and calculations are described in the MIRDy90 documentation and articulated in the MIRDy90 worksheet. The worksheet is distributed as a free tool to build expertise within the medical physics community and create a vetted standard for model and variable management.</abstract><cop>New York</cop><pub>Society of Nuclear Medicine</pub><pmid>38388514</pmid><doi>10.2967/jnumed.123.266743</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0161-5505
ispartof The Journal of nuclear medicine (1978), 2024-05, Vol.65 (5), p.1-802
issn 0161-5505
1535-5667
1535-5667
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_11064830
source EZB-FREE-00999 freely available EZB journals; Alma/SFX Local Collection
subjects Basic Science Investigation
Brachytherapy
Dosimeters
Dosimetry
Malignancy
Mathematical models
Parameters
Patients
Radiation therapy
Radioisotopes
Software
Surface area
Yttrium isotopes
title MIRD Pamphlet No. 29: MIRDy90-A 90Y Research Microsphere Dosimetry Tool
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T01%3A36%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=MIRD%20Pamphlet%20No.%2029:%20MIRDy90-A%2090Y%20Research%20Microsphere%20Dosimetry%20Tool&rft.jtitle=The%20Journal%20of%20nuclear%20medicine%20(1978)&rft.au=Marquis,%20Harry&rft.date=2024-05-01&rft.volume=65&rft.issue=5&rft.spage=1&rft.epage=802&rft.pages=1-802&rft.issn=0161-5505&rft.eissn=1535-5667&rft_id=info:doi/10.2967/jnumed.123.266743&rft_dat=%3Cproquest_pubme%3E3050942929%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3051583383&rft_id=info:pmid/38388514&rfr_iscdi=true