Effect of Endo-Z bur or Bladesonic ultrasonic tip on the adaptation of filling material. A micro-CT study
This study aimed to evaluate the effect of apicoectomy performed with a bur or an ultrasonic tip on the adaptation of the filling material to root canal dentin. Twenty human mandibular incisors were selected and prepared with a ProDesign Logic system up to diameter 40/.05. The root canals were fille...
Gespeichert in:
Veröffentlicht in: | Brazilian dental journal 2023, Vol.34 (5), p.29-35 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 35 |
---|---|
container_issue | 5 |
container_start_page | 29 |
container_title | Brazilian dental journal |
container_volume | 34 |
creator | Souza, Pedro Henrique Fiorin de Oliveira Santos-Junior, Airton Pinto, Jáder Camilo Tavares, Karina Ines Medina Carita Guerreiro-Tanomaru, Juliane Maria Tanomaru-Filho, Mário |
description | This study aimed to evaluate the effect of apicoectomy performed with a bur or an ultrasonic tip on the adaptation of the filling material to root canal dentin. Twenty human mandibular incisors were selected and prepared with a ProDesign Logic system up to diameter 40/.05. The root canals were filled with Bio-C Sealer (Angelus, PR, Brazil) using the single cone technique and were stored at 37ºC and 95% relative humidity for 7 days. After this period, the apicoectomy of the 3 millimeters of the root apex was performed using Endo-Z bur (Dentsply Sirona) or Bladesonic ultrasonic tip (Helse Ultrasonic, Santa Rosa de Viterbo, Brazil) (n=10). The specimens were scanned by micro-computed tomography (micro-CT; SkyScan 1176) with a voxel size of 8.74 µm after obturation and after apicoectomy. The percentage of voids at the interface between the filling material and the root canal wall was evaluated in the apical 4 mm of the root after apicoectomy, besides the time cutting to both devices. The data obtained were submitted to paired and unpaired t-tests (α = 0.05). Endo-Z and Bladesonic increased the percentage of voids between the filling material and the dentin after apicectomy (p0.05). Endo-Z has a shorter time to perform apicoectomy compared to Bladesonic (p |
doi_str_mv | 10.1590/0103-6440202305474 |
format | Article |
fullrecord | <record><control><sourceid>pubmed_cross</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_10759957</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>38133470</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3084-500a7ededc26b05c645e0c190f1c9cb09eb973135d7b045688b63f54e915ff343</originalsourceid><addsrcrecordid>eNpVkMtOwzAQRS0EoqXwAyyQfyBlHNtxvEKlKg-pEpuyYWM5jt0aJXGUBxJ_j6tCRVczo5l75uoidEtgTriEeyBAk4wxSCGlwJlgZ2hKcsgSJjI4R9PjwQRd9f0nxENG5SWa0JxQygRMkV85Z82Ag8OrpgzJBy7GDocOP1a6tH1ovMFjNXT60A6-xaHBw85iXep20IOPYxQ7X1W-2eJaD7bzuprjBa696UKy3OB-GMvva3ThdNXbm986Q-9Pq83yJVm_Pb8uF-vEUMhZwgG0sKUtTZoVwE3GuAVDJDhipClA2kIKSigvRQGMZ3leZNRxZiXhzlFGZ-jhwG3Hoo4Y20T3lWo7X-vuWwXt1emm8Tu1DV-KgOBSchEJ6YEQ7fd9Z91RTEDtk1f7YNVJ8lF09__tUfIXNf0B5mp-3g</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Effect of Endo-Z bur or Bladesonic ultrasonic tip on the adaptation of filling material. A micro-CT study</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central</source><source>PubMed Central Open Access</source><creator>Souza, Pedro Henrique Fiorin de ; Oliveira Santos-Junior, Airton ; Pinto, Jáder Camilo ; Tavares, Karina Ines Medina Carita ; Guerreiro-Tanomaru, Juliane Maria ; Tanomaru-Filho, Mário</creator><creatorcontrib>Souza, Pedro Henrique Fiorin de ; Oliveira Santos-Junior, Airton ; Pinto, Jáder Camilo ; Tavares, Karina Ines Medina Carita ; Guerreiro-Tanomaru, Juliane Maria ; Tanomaru-Filho, Mário</creatorcontrib><description>This study aimed to evaluate the effect of apicoectomy performed with a bur or an ultrasonic tip on the adaptation of the filling material to root canal dentin. Twenty human mandibular incisors were selected and prepared with a ProDesign Logic system up to diameter 40/.05. The root canals were filled with Bio-C Sealer (Angelus, PR, Brazil) using the single cone technique and were stored at 37ºC and 95% relative humidity for 7 days. After this period, the apicoectomy of the 3 millimeters of the root apex was performed using Endo-Z bur (Dentsply Sirona) or Bladesonic ultrasonic tip (Helse Ultrasonic, Santa Rosa de Viterbo, Brazil) (n=10). The specimens were scanned by micro-computed tomography (micro-CT; SkyScan 1176) with a voxel size of 8.74 µm after obturation and after apicoectomy. The percentage of voids at the interface between the filling material and the root canal wall was evaluated in the apical 4 mm of the root after apicoectomy, besides the time cutting to both devices. The data obtained were submitted to paired and unpaired t-tests (α = 0.05). Endo-Z and Bladesonic increased the percentage of voids between the filling material and the dentin after apicectomy (p<0.05), and they were similar (p>0.05). Endo-Z has a shorter time to perform apicoectomy compared to Bladesonic (p<0.05). Apicectomies with Endo-Z or Bladesonic could harm the material/dentin interface, while the Endo-Z bur was faster than the Bladesonic ultrasonic tip.</description><identifier>ISSN: 0103-6440</identifier><identifier>EISSN: 1806-4760</identifier><identifier>DOI: 10.1590/0103-6440202305474</identifier><identifier>PMID: 38133470</identifier><language>eng</language><publisher>Brazil: Fundação Odontológica de Ribeirão Preto</publisher><ispartof>Brazilian dental journal, 2023, Vol.34 (5), p.29-35</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c3084-500a7ededc26b05c645e0c190f1c9cb09eb973135d7b045688b63f54e915ff343</cites><orcidid>0000-0003-2023-1589 ; 0000-0002-4173-8285 ; 0000-0003-1916-1675 ; 0000-0002-2574-4706 ; 0000-0003-0446-2037 ; 0000-0001-7916-7900</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC10759957/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC10759957/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,723,776,780,881,4010,27900,27901,27902,53766,53768</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38133470$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Souza, Pedro Henrique Fiorin de</creatorcontrib><creatorcontrib>Oliveira Santos-Junior, Airton</creatorcontrib><creatorcontrib>Pinto, Jáder Camilo</creatorcontrib><creatorcontrib>Tavares, Karina Ines Medina Carita</creatorcontrib><creatorcontrib>Guerreiro-Tanomaru, Juliane Maria</creatorcontrib><creatorcontrib>Tanomaru-Filho, Mário</creatorcontrib><title>Effect of Endo-Z bur or Bladesonic ultrasonic tip on the adaptation of filling material. A micro-CT study</title><title>Brazilian dental journal</title><addtitle>Braz Dent J</addtitle><description>This study aimed to evaluate the effect of apicoectomy performed with a bur or an ultrasonic tip on the adaptation of the filling material to root canal dentin. Twenty human mandibular incisors were selected and prepared with a ProDesign Logic system up to diameter 40/.05. The root canals were filled with Bio-C Sealer (Angelus, PR, Brazil) using the single cone technique and were stored at 37ºC and 95% relative humidity for 7 days. After this period, the apicoectomy of the 3 millimeters of the root apex was performed using Endo-Z bur (Dentsply Sirona) or Bladesonic ultrasonic tip (Helse Ultrasonic, Santa Rosa de Viterbo, Brazil) (n=10). The specimens were scanned by micro-computed tomography (micro-CT; SkyScan 1176) with a voxel size of 8.74 µm after obturation and after apicoectomy. The percentage of voids at the interface between the filling material and the root canal wall was evaluated in the apical 4 mm of the root after apicoectomy, besides the time cutting to both devices. The data obtained were submitted to paired and unpaired t-tests (α = 0.05). Endo-Z and Bladesonic increased the percentage of voids between the filling material and the dentin after apicectomy (p<0.05), and they were similar (p>0.05). Endo-Z has a shorter time to perform apicoectomy compared to Bladesonic (p<0.05). Apicectomies with Endo-Z or Bladesonic could harm the material/dentin interface, while the Endo-Z bur was faster than the Bladesonic ultrasonic tip.</description><issn>0103-6440</issn><issn>1806-4760</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNpVkMtOwzAQRS0EoqXwAyyQfyBlHNtxvEKlKg-pEpuyYWM5jt0aJXGUBxJ_j6tCRVczo5l75uoidEtgTriEeyBAk4wxSCGlwJlgZ2hKcsgSJjI4R9PjwQRd9f0nxENG5SWa0JxQygRMkV85Z82Ag8OrpgzJBy7GDocOP1a6tH1ovMFjNXT60A6-xaHBw85iXep20IOPYxQ7X1W-2eJaD7bzuprjBa696UKy3OB-GMvva3ThdNXbm986Q-9Pq83yJVm_Pb8uF-vEUMhZwgG0sKUtTZoVwE3GuAVDJDhipClA2kIKSigvRQGMZ3leZNRxZiXhzlFGZ-jhwG3Hoo4Y20T3lWo7X-vuWwXt1emm8Tu1DV-KgOBSchEJ6YEQ7fd9Z91RTEDtk1f7YNVJ8lF09__tUfIXNf0B5mp-3g</recordid><startdate>2023</startdate><enddate>2023</enddate><creator>Souza, Pedro Henrique Fiorin de</creator><creator>Oliveira Santos-Junior, Airton</creator><creator>Pinto, Jáder Camilo</creator><creator>Tavares, Karina Ines Medina Carita</creator><creator>Guerreiro-Tanomaru, Juliane Maria</creator><creator>Tanomaru-Filho, Mário</creator><general>Fundação Odontológica de Ribeirão Preto</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0003-2023-1589</orcidid><orcidid>https://orcid.org/0000-0002-4173-8285</orcidid><orcidid>https://orcid.org/0000-0003-1916-1675</orcidid><orcidid>https://orcid.org/0000-0002-2574-4706</orcidid><orcidid>https://orcid.org/0000-0003-0446-2037</orcidid><orcidid>https://orcid.org/0000-0001-7916-7900</orcidid></search><sort><creationdate>2023</creationdate><title>Effect of Endo-Z bur or Bladesonic ultrasonic tip on the adaptation of filling material. A micro-CT study</title><author>Souza, Pedro Henrique Fiorin de ; Oliveira Santos-Junior, Airton ; Pinto, Jáder Camilo ; Tavares, Karina Ines Medina Carita ; Guerreiro-Tanomaru, Juliane Maria ; Tanomaru-Filho, Mário</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3084-500a7ededc26b05c645e0c190f1c9cb09eb973135d7b045688b63f54e915ff343</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Souza, Pedro Henrique Fiorin de</creatorcontrib><creatorcontrib>Oliveira Santos-Junior, Airton</creatorcontrib><creatorcontrib>Pinto, Jáder Camilo</creatorcontrib><creatorcontrib>Tavares, Karina Ines Medina Carita</creatorcontrib><creatorcontrib>Guerreiro-Tanomaru, Juliane Maria</creatorcontrib><creatorcontrib>Tanomaru-Filho, Mário</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Brazilian dental journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Souza, Pedro Henrique Fiorin de</au><au>Oliveira Santos-Junior, Airton</au><au>Pinto, Jáder Camilo</au><au>Tavares, Karina Ines Medina Carita</au><au>Guerreiro-Tanomaru, Juliane Maria</au><au>Tanomaru-Filho, Mário</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of Endo-Z bur or Bladesonic ultrasonic tip on the adaptation of filling material. A micro-CT study</atitle><jtitle>Brazilian dental journal</jtitle><addtitle>Braz Dent J</addtitle><date>2023</date><risdate>2023</risdate><volume>34</volume><issue>5</issue><spage>29</spage><epage>35</epage><pages>29-35</pages><issn>0103-6440</issn><eissn>1806-4760</eissn><abstract>This study aimed to evaluate the effect of apicoectomy performed with a bur or an ultrasonic tip on the adaptation of the filling material to root canal dentin. Twenty human mandibular incisors were selected and prepared with a ProDesign Logic system up to diameter 40/.05. The root canals were filled with Bio-C Sealer (Angelus, PR, Brazil) using the single cone technique and were stored at 37ºC and 95% relative humidity for 7 days. After this period, the apicoectomy of the 3 millimeters of the root apex was performed using Endo-Z bur (Dentsply Sirona) or Bladesonic ultrasonic tip (Helse Ultrasonic, Santa Rosa de Viterbo, Brazil) (n=10). The specimens were scanned by micro-computed tomography (micro-CT; SkyScan 1176) with a voxel size of 8.74 µm after obturation and after apicoectomy. The percentage of voids at the interface between the filling material and the root canal wall was evaluated in the apical 4 mm of the root after apicoectomy, besides the time cutting to both devices. The data obtained were submitted to paired and unpaired t-tests (α = 0.05). Endo-Z and Bladesonic increased the percentage of voids between the filling material and the dentin after apicectomy (p<0.05), and they were similar (p>0.05). Endo-Z has a shorter time to perform apicoectomy compared to Bladesonic (p<0.05). Apicectomies with Endo-Z or Bladesonic could harm the material/dentin interface, while the Endo-Z bur was faster than the Bladesonic ultrasonic tip.</abstract><cop>Brazil</cop><pub>Fundação Odontológica de Ribeirão Preto</pub><pmid>38133470</pmid><doi>10.1590/0103-6440202305474</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0003-2023-1589</orcidid><orcidid>https://orcid.org/0000-0002-4173-8285</orcidid><orcidid>https://orcid.org/0000-0003-1916-1675</orcidid><orcidid>https://orcid.org/0000-0002-2574-4706</orcidid><orcidid>https://orcid.org/0000-0003-0446-2037</orcidid><orcidid>https://orcid.org/0000-0001-7916-7900</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0103-6440 |
ispartof | Brazilian dental journal, 2023, Vol.34 (5), p.29-35 |
issn | 0103-6440 1806-4760 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_10759957 |
source | Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central; PubMed Central Open Access |
title | Effect of Endo-Z bur or Bladesonic ultrasonic tip on the adaptation of filling material. A micro-CT study |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-12T16%3A36%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20Endo-Z%20bur%20or%20Bladesonic%20ultrasonic%20tip%20on%20the%20adaptation%20of%20filling%20material.%20A%20micro-CT%20study&rft.jtitle=Brazilian%20dental%20journal&rft.au=Souza,%20Pedro%20Henrique%20Fiorin%20de&rft.date=2023&rft.volume=34&rft.issue=5&rft.spage=29&rft.epage=35&rft.pages=29-35&rft.issn=0103-6440&rft.eissn=1806-4760&rft_id=info:doi/10.1590/0103-6440202305474&rft_dat=%3Cpubmed_cross%3E38133470%3C/pubmed_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/38133470&rfr_iscdi=true |