Systematic Workflow and Electrogram guidance to reduce X-ray Exposure Time during cryoballoon ablation of atrial fibrillation: the SWEET-Cryo strategy
Abstract Aims Cryoballoon pulmonary vein isolation (CB-PVI) offers similar efficacy to point-by-point radiofrequency PVI for patients with atrial fibrillation (AF), but generally with higher X-ray exposure. Strategies aimed at reducing fluoroscopy mostly rely on other costly imaging techniques, limi...
Gespeichert in:
Veröffentlicht in: | Europace (London, England) England), 2023-08, Vol.25 (9) |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Abstract
Aims
Cryoballoon pulmonary vein isolation (CB-PVI) offers similar efficacy to point-by-point radiofrequency PVI for patients with atrial fibrillation (AF), but generally with higher X-ray exposure. Strategies aimed at reducing fluoroscopy mostly rely on other costly imaging techniques, limiting their applicability. We designed a Systematic Workflow and Electrogram guidance to reduce X-ray Exposure Time during CB-PVI (SWEET-Cryo) strategy and analysed its impact on fluoroscopy use and acute procedural and clinical outcomes.
Methods and results
We enrolled 100 patients with paroxysmal or persistent AF undergoing CB-PVI by two operators with different levels of expertise. Patients treated with the SWEET-Cryo strategy (prospective cohort; n = 50) or conventional fluoroscopy (retrospective control cohort; n = 50) were compared. When applied by the senior operator, the SWEET-Cryo strategy significantly reduced the mean fluoroscopy time (FT) (2.6 ± 1.25 vs. 20.3 ± 10.8 min) and mean dose area product (DAP) (5.1 ± 3.8 vs. 35.3 ± 22.3 Gy cm2) compared with those of the control group, respectively (P < 0.001). Significant reductions in FT (6.4 ± 2.5 min vs. 32.5 ± 10.05) and DAP (13.9 ± 7.7 vs. 92.3 ± 63.8) were also achieved by the less experienced operator (P < 0.001). No difference was observed in acute and long-term complications or freedom from AF between fluoroscopy strategies during a 33-month median follow-up. Mean FT was maintained below 3 min in randomly selected cases performed during the follow-up period.
Conclusion
In contrast to conventional protocols and regardless of the operator’s experience, the optimized SWEET-Cryo strategy dramatically reduced fluoroscopy exposure during CB-PVI. The efficacy, safety, or added costs of the ablation procedure were not compromised.
Graphical Abstract