Retinal laser lenses: magnification, spot size, and field of view

Proper use of ophthalmoscopic contact lenses for retinal photocoagulation requires knowledge of their comparative magnification, spot size, and field of view. We determined these parameters for four commonly used lenses, using data measured from optical components of the lenses and a commonly used p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:British journal of ophthalmology 1990-03, Vol.74 (3), p.177-179
Hauptverfasser: Mainster, M A, Crossman, J L, Erickson, P J, Heacock, G L
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 179
container_issue 3
container_start_page 177
container_title British journal of ophthalmology
container_volume 74
creator Mainster, M A
Crossman, J L
Erickson, P J
Heacock, G L
description Proper use of ophthalmoscopic contact lenses for retinal photocoagulation requires knowledge of their comparative magnification, spot size, and field of view. We determined these parameters for four commonly used lenses, using data measured from optical components of the lenses and a commonly used photo-coagulator slit-lamp and spot size changer. A Krieger lens has 8% more working field of view and 29% less magnification than a Goldmann lens. A Panfundoscope lens has 84% more working field of view and 24% less magnification than a Goldmann lens. A Mainster lens has 58% more working field of view and 3% more magnification than a Goldmann lens. For Goldmann, Krieger, Panfundoscope, and Mainster lenses, respectively, retinal spot size is 8%, 53%, 41%, and 5% greater than photo-coagulator spot size settings. The field of view of each lens is increased in myopic and decreased in hyperopic patients. Anterior segment irradiance is higher than retinal irradiance for 1000 microns spot size settings with a Panfundoscope or Mainster lens, and this setting should be avoided, especially in patients with hazy ocular media.
doi_str_mv 10.1136/bjo.74.3.177
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_1042043</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3969825111</sourcerecordid><originalsourceid>FETCH-LOGICAL-b535t-eac29b25d0a29e78310cb11460c9a0a65e2a63e270f1ed4b76349aec690b0f093</originalsourceid><addsrcrecordid>eNp9kc2LFDEUxIMo6-zqzavQoKyX6fEl6U42HoRl_FhhUdDVg5fwOv16zdjdGZOe9eOvN8MMg3rwFEL9XlFUMfaAw4JzqZ42q7DQ1UIuuNa32IxX6qwUoM1tNgMAXXKu-F12nNIqf4Xi-ogdCSlEzfWMnb-nyY_YFz0mikVPY6L0rBjwevSddzj5MM6LtA5Tkfwvmhc4tkXnqW-L0BU3nr7fY3c67BPd378n7OOrl1fLi_Ly3es3y_PLsqllPZWETphG1C2gMKTPJAfX8BwWnEFAVZNAJUlo6Di1VaOVrAySUwYa6MDIE_Z857veNAO1jsYpYm_X0Q8Yf9qA3v6tjP6LvQ43lkMloJLZ4HRvEMO3DaXJDj456nscKWyS1UZzmYNl8NE_4CpsYi4p2VwxgFRab_PMd5SLIaVI3SEKB7sdxuZhrK6s3F5l_OGf8Q_wfomsP97rmBz2XcTR-XTAcg2ag8hYucN8mujHQcb41SotdW3fflra5Yerzy9MbexF5p_s-GZY_T_gb5olsLo</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1770036779</pqid></control><display><type>article</type><title>Retinal laser lenses: magnification, spot size, and field of view</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central</source><source>Alma/SFX Local Collection</source><creator>Mainster, M A ; Crossman, J L ; Erickson, P J ; Heacock, G L</creator><creatorcontrib>Mainster, M A ; Crossman, J L ; Erickson, P J ; Heacock, G L</creatorcontrib><description>Proper use of ophthalmoscopic contact lenses for retinal photocoagulation requires knowledge of their comparative magnification, spot size, and field of view. We determined these parameters for four commonly used lenses, using data measured from optical components of the lenses and a commonly used photo-coagulator slit-lamp and spot size changer. A Krieger lens has 8% more working field of view and 29% less magnification than a Goldmann lens. A Panfundoscope lens has 84% more working field of view and 24% less magnification than a Goldmann lens. A Mainster lens has 58% more working field of view and 3% more magnification than a Goldmann lens. For Goldmann, Krieger, Panfundoscope, and Mainster lenses, respectively, retinal spot size is 8%, 53%, 41%, and 5% greater than photo-coagulator spot size settings. The field of view of each lens is increased in myopic and decreased in hyperopic patients. Anterior segment irradiance is higher than retinal irradiance for 1000 microns spot size settings with a Panfundoscope or Mainster lens, and this setting should be avoided, especially in patients with hazy ocular media.</description><identifier>ISSN: 0007-1161</identifier><identifier>EISSN: 1468-2079</identifier><identifier>DOI: 10.1136/bjo.74.3.177</identifier><identifier>PMID: 2322517</identifier><identifier>CODEN: BJOPAL</identifier><language>eng</language><publisher>BMA House, Tavistock Square, London, WC1H 9JR: BMJ Publishing Group Ltd</publisher><subject>Biological and medical sciences ; Contact Lenses ; Eye ; Humans ; Light Coagulation - instrumentation ; Medical sciences ; Models, Anatomic ; Ophthalmoscopy ; Optics and Photonics ; Retina - surgery ; Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases ; Surgery of the eye and orbit</subject><ispartof>British journal of ophthalmology, 1990-03, Vol.74 (3), p.177-179</ispartof><rights>1990 INIST-CNRS</rights><rights>Copyright BMJ Publishing Group LTD Mar 1990</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-b535t-eac29b25d0a29e78310cb11460c9a0a65e2a63e270f1ed4b76349aec690b0f093</citedby><cites>FETCH-LOGICAL-b535t-eac29b25d0a29e78310cb11460c9a0a65e2a63e270f1ed4b76349aec690b0f093</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC1042043/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC1042043/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,723,776,780,881,27903,27904,53769,53771</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=6907102$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/2322517$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Mainster, M A</creatorcontrib><creatorcontrib>Crossman, J L</creatorcontrib><creatorcontrib>Erickson, P J</creatorcontrib><creatorcontrib>Heacock, G L</creatorcontrib><title>Retinal laser lenses: magnification, spot size, and field of view</title><title>British journal of ophthalmology</title><addtitle>Br J Ophthalmol</addtitle><description>Proper use of ophthalmoscopic contact lenses for retinal photocoagulation requires knowledge of their comparative magnification, spot size, and field of view. We determined these parameters for four commonly used lenses, using data measured from optical components of the lenses and a commonly used photo-coagulator slit-lamp and spot size changer. A Krieger lens has 8% more working field of view and 29% less magnification than a Goldmann lens. A Panfundoscope lens has 84% more working field of view and 24% less magnification than a Goldmann lens. A Mainster lens has 58% more working field of view and 3% more magnification than a Goldmann lens. For Goldmann, Krieger, Panfundoscope, and Mainster lenses, respectively, retinal spot size is 8%, 53%, 41%, and 5% greater than photo-coagulator spot size settings. The field of view of each lens is increased in myopic and decreased in hyperopic patients. Anterior segment irradiance is higher than retinal irradiance for 1000 microns spot size settings with a Panfundoscope or Mainster lens, and this setting should be avoided, especially in patients with hazy ocular media.</description><subject>Biological and medical sciences</subject><subject>Contact Lenses</subject><subject>Eye</subject><subject>Humans</subject><subject>Light Coagulation - instrumentation</subject><subject>Medical sciences</subject><subject>Models, Anatomic</subject><subject>Ophthalmoscopy</subject><subject>Optics and Photonics</subject><subject>Retina - surgery</subject><subject>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</subject><subject>Surgery of the eye and orbit</subject><issn>0007-1161</issn><issn>1468-2079</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1990</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><recordid>eNp9kc2LFDEUxIMo6-zqzavQoKyX6fEl6U42HoRl_FhhUdDVg5fwOv16zdjdGZOe9eOvN8MMg3rwFEL9XlFUMfaAw4JzqZ42q7DQ1UIuuNa32IxX6qwUoM1tNgMAXXKu-F12nNIqf4Xi-ogdCSlEzfWMnb-nyY_YFz0mikVPY6L0rBjwevSddzj5MM6LtA5Tkfwvmhc4tkXnqW-L0BU3nr7fY3c67BPd378n7OOrl1fLi_Ly3es3y_PLsqllPZWETphG1C2gMKTPJAfX8BwWnEFAVZNAJUlo6Di1VaOVrAySUwYa6MDIE_Z857veNAO1jsYpYm_X0Q8Yf9qA3v6tjP6LvQ43lkMloJLZ4HRvEMO3DaXJDj456nscKWyS1UZzmYNl8NE_4CpsYi4p2VwxgFRab_PMd5SLIaVI3SEKB7sdxuZhrK6s3F5l_OGf8Q_wfomsP97rmBz2XcTR-XTAcg2ag8hYucN8mujHQcb41SotdW3fflra5Yerzy9MbexF5p_s-GZY_T_gb5olsLo</recordid><startdate>19900301</startdate><enddate>19900301</enddate><creator>Mainster, M A</creator><creator>Crossman, J L</creator><creator>Erickson, P J</creator><creator>Heacock, G L</creator><general>BMJ Publishing Group Ltd</general><general>BMJ</general><general>BMJ Publishing Group LTD</general><scope>BSCLL</scope><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>BTHHO</scope><scope>CCPQU</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>M1P</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>19900301</creationdate><title>Retinal laser lenses: magnification, spot size, and field of view</title><author>Mainster, M A ; Crossman, J L ; Erickson, P J ; Heacock, G L</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-b535t-eac29b25d0a29e78310cb11460c9a0a65e2a63e270f1ed4b76349aec690b0f093</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1990</creationdate><topic>Biological and medical sciences</topic><topic>Contact Lenses</topic><topic>Eye</topic><topic>Humans</topic><topic>Light Coagulation - instrumentation</topic><topic>Medical sciences</topic><topic>Models, Anatomic</topic><topic>Ophthalmoscopy</topic><topic>Optics and Photonics</topic><topic>Retina - surgery</topic><topic>Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases</topic><topic>Surgery of the eye and orbit</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mainster, M A</creatorcontrib><creatorcontrib>Crossman, J L</creatorcontrib><creatorcontrib>Erickson, P J</creatorcontrib><creatorcontrib>Heacock, G L</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central</collection><collection>BMJ Journals</collection><collection>ProQuest One Community College</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>British journal of ophthalmology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mainster, M A</au><au>Crossman, J L</au><au>Erickson, P J</au><au>Heacock, G L</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Retinal laser lenses: magnification, spot size, and field of view</atitle><jtitle>British journal of ophthalmology</jtitle><addtitle>Br J Ophthalmol</addtitle><date>1990-03-01</date><risdate>1990</risdate><volume>74</volume><issue>3</issue><spage>177</spage><epage>179</epage><pages>177-179</pages><issn>0007-1161</issn><eissn>1468-2079</eissn><coden>BJOPAL</coden><abstract>Proper use of ophthalmoscopic contact lenses for retinal photocoagulation requires knowledge of their comparative magnification, spot size, and field of view. We determined these parameters for four commonly used lenses, using data measured from optical components of the lenses and a commonly used photo-coagulator slit-lamp and spot size changer. A Krieger lens has 8% more working field of view and 29% less magnification than a Goldmann lens. A Panfundoscope lens has 84% more working field of view and 24% less magnification than a Goldmann lens. A Mainster lens has 58% more working field of view and 3% more magnification than a Goldmann lens. For Goldmann, Krieger, Panfundoscope, and Mainster lenses, respectively, retinal spot size is 8%, 53%, 41%, and 5% greater than photo-coagulator spot size settings. The field of view of each lens is increased in myopic and decreased in hyperopic patients. Anterior segment irradiance is higher than retinal irradiance for 1000 microns spot size settings with a Panfundoscope or Mainster lens, and this setting should be avoided, especially in patients with hazy ocular media.</abstract><cop>BMA House, Tavistock Square, London, WC1H 9JR</cop><pub>BMJ Publishing Group Ltd</pub><pmid>2322517</pmid><doi>10.1136/bjo.74.3.177</doi><tpages>3</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0007-1161
ispartof British journal of ophthalmology, 1990-03, Vol.74 (3), p.177-179
issn 0007-1161
1468-2079
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_1042043
source MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central; Alma/SFX Local Collection
subjects Biological and medical sciences
Contact Lenses
Eye
Humans
Light Coagulation - instrumentation
Medical sciences
Models, Anatomic
Ophthalmoscopy
Optics and Photonics
Retina - surgery
Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases
Surgery of the eye and orbit
title Retinal laser lenses: magnification, spot size, and field of view
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-23T16%3A32%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Retinal%20laser%20lenses:%20magnification,%20spot%20size,%20and%20field%20of%20view&rft.jtitle=British%20journal%20of%20ophthalmology&rft.au=Mainster,%20M%20A&rft.date=1990-03-01&rft.volume=74&rft.issue=3&rft.spage=177&rft.epage=179&rft.pages=177-179&rft.issn=0007-1161&rft.eissn=1468-2079&rft.coden=BJOPAL&rft_id=info:doi/10.1136/bjo.74.3.177&rft_dat=%3Cproquest_pubme%3E3969825111%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1770036779&rft_id=info:pmid/2322517&rfr_iscdi=true