MRI-Conditional Breast Tissue Expander: First In-Human Multi-Case Assessment of MRI-Related Complications and Image Quality
This study aims to assess potential complications and effects on the magnetic resonance imaging (MRI) image quality of a new MRI-conditional breast tissue expander (Motiva Flora ) in its first in-human multi-case application. Twenty-four patients with 36 expanders underwent non-contrast breast MRI w...
Gespeichert in:
Veröffentlicht in: | Journal of clinical medicine 2023-06, Vol.12 (13), p.4410 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This study aims to assess potential complications and effects on the magnetic resonance imaging (MRI) image quality of a new MRI-conditional breast tissue expander (Motiva Flora
) in its first in-human multi-case application. Twenty-four patients with 36 expanders underwent non-contrast breast MRI with T1-weighted, T2-weighted, and diffusion-weighted imaging (DWI) sequences on a 3 T unit before breast tissue expander exchange surgery, being monitored during and after MRI for potential complications. Three board-certified breast radiologists blindly and independently reviewed image quality using a four-level scale ("poor", "sufficient", "good", and "excellent"), with inter-reader reliability being assessed with Kendall's τ
. The maximum diameters of RFID-related artifacts on T1-weighted and DWI sequences were compared with the Wilcoxon signed-rank test. All 24 examinations were completed without patient-related or device-related complications. The T1-weighted and T2-weighted sequences of all the examinations had "excellent" image quality and a median 11 mm (IQR 9-12 mm) RFID artifact maximum diameter, significantly lower (
< 0.001) than on the DWI images (median 32.5 mm, IQR 28.5-34.5 mm). DWI quality was rated at least "good" in 63% of the examinations, with strong inter-reader reliability (Kendall's τ
0.837, 95% CI 0.687-0.952). This first in-human study confirms the MRI-conditional profile of this new expander, which does not affect the image quality of T1-weighted and T2-weighted sequences and moderately affects DWI quality. |
---|---|
ISSN: | 2077-0383 2077-0383 |
DOI: | 10.3390/jcm12134410 |