Rapid on-site evaluation (ROSE) versus macroscopic on-site evaluation (MOSE) for endoscopic ultrasound-guided sampling of solid pancreatic lesions: a paired comparative analysis using newer-generation fine needle biopsy needles
Rapid on-site examination (ROSE) during endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) has been a subject of debate. We compared the yield of EUS-FNB with adequacy assessed using macroscopic on-site evaluation (MOSE), and smear cytology with adequacy confirmed by ROSE, acquired using the...
Gespeichert in:
Veröffentlicht in: | Annals of gastroenterology 2023-01, Vol.36 (3), p.340-346 |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 346 |
---|---|
container_issue | 3 |
container_start_page | 340 |
container_title | Annals of gastroenterology |
container_volume | 36 |
creator | Sundaram, Sridhar Chhanchure, Utkarsh Patil, Prachi Seth, Vishal Mahajan, Akhil Bal, Munita Kaushal, Rajiv Kumar Ramadwar, Mukta Prabhudesai, Neelam Bhandare, Manish Shrikhande, Shailesh V Mehta, Shaesta |
description | Rapid on-site examination (ROSE) during endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) has been a subject of debate. We compared the yield of EUS-FNB with adequacy assessed using macroscopic on-site evaluation (MOSE), and smear cytology with adequacy confirmed by ROSE, acquired using the same needle.
Consecutive patients with solid pancreatic lesions (SPLs) who underwent EUS-FNB of pancreatic solid lesions between January 2021 and July 2022 were included. Demographic details, site and size of lesion, number of passes, and the diagnosis by cytology and histopathology of core tissue were noted. The first pass was used for ROSE adequacy assessment and was subsequently sent for cytological assessment. Additional passes were taken subsequently to acquire core tissue. Adequacy was confirmed by MOSE (whitish core of more than 4 mm). Final cytology and histopathology (HPE) were compared for diagnostic accuracy.
One hundred fifty-five patients were included in the analysis during the study period (mean age 55.1+12.9 years; 60% male; 77% in pancreatic head; median size 3.7 cm). The final diagnosis was malignancy in 129, while 26 were negative for malignancy. Sensitivity and specificity for ROSE with cytology in detecting malignant SPLs were 96.9% and 100%, respectively. HPE with MOSE had sensitivity and specificity of 96.1% and 100%, respectively. A comparison of diagnostic accuracy showed no significant difference (P>0.99) between HPE with MOSE and ROSE with cytology, using an FNB needle.
MOSE is as good as ROSE in terms of diagnostic yield for solid pancreatic lesions sampled using newer-generation EUS biopsy needles. |
doi_str_mv | 10.20524/aog.2023.0790 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_10152805</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2810915374</sourcerecordid><originalsourceid>FETCH-LOGICAL-c346t-875b295a7b3cf79166a15a98ff596603844c790a912c8cf781aaca7b6cb1eafe3</originalsourceid><addsrcrecordid>eNptkk1v1DAQhiMEoqVw5Yh8LIcsduLECRdUVeVDKqpU4GxNnEkwcuzgSRbt7-WP4O1uK5A4eTzz-J2x_WbZS8E3Ba8K-QbCmKKi3HDV8kfZqVBtkStZl49TLHiTYiVOsmdEPzivaiXl0-ykVEJKLtRp9vsWZtuz4HOyCzLcglthscGz89ubL1ev2RYjrcQmMDGQCbM1_4U_38FDiAx9fw-ubolAYfV9Pq62x54RTLOzfmRhYBRc6jyDNxGTimEOKWnRWwYpa2PCTZhmiKm4RQYe3I4ssZX2Ah5_YcxH9BgPIwzWY8pi75B1Nsy0O-7oefZkAEf44rieZd_eX329_Jhf33z4dHlxnZtS1kveqKor2gpUV5pBtaKuQVTQNsNQtXXNy0ZKk94YWlGYJhGNADCJrk0nEAYsz7J3B9157SbsDfp0fafnaCeIOx3A6n8r3n7XY9hqwUVVNLxKCudHhRh-rkiLniwZdA48hpV00QjeiqpUMqGbA7r_F4o4PPQRXN9ZQydr6L019N4a6cCrv6d7wO-9UP4Bpaa8Og</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2810915374</pqid></control><display><type>article</type><title>Rapid on-site evaluation (ROSE) versus macroscopic on-site evaluation (MOSE) for endoscopic ultrasound-guided sampling of solid pancreatic lesions: a paired comparative analysis using newer-generation fine needle biopsy needles</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central Open Access</source><source>PubMed Central</source><creator>Sundaram, Sridhar ; Chhanchure, Utkarsh ; Patil, Prachi ; Seth, Vishal ; Mahajan, Akhil ; Bal, Munita ; Kaushal, Rajiv Kumar ; Ramadwar, Mukta ; Prabhudesai, Neelam ; Bhandare, Manish ; Shrikhande, Shailesh V ; Mehta, Shaesta</creator><creatorcontrib>Sundaram, Sridhar ; Chhanchure, Utkarsh ; Patil, Prachi ; Seth, Vishal ; Mahajan, Akhil ; Bal, Munita ; Kaushal, Rajiv Kumar ; Ramadwar, Mukta ; Prabhudesai, Neelam ; Bhandare, Manish ; Shrikhande, Shailesh V ; Mehta, Shaesta</creatorcontrib><description>Rapid on-site examination (ROSE) during endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) has been a subject of debate. We compared the yield of EUS-FNB with adequacy assessed using macroscopic on-site evaluation (MOSE), and smear cytology with adequacy confirmed by ROSE, acquired using the same needle.
Consecutive patients with solid pancreatic lesions (SPLs) who underwent EUS-FNB of pancreatic solid lesions between January 2021 and July 2022 were included. Demographic details, site and size of lesion, number of passes, and the diagnosis by cytology and histopathology of core tissue were noted. The first pass was used for ROSE adequacy assessment and was subsequently sent for cytological assessment. Additional passes were taken subsequently to acquire core tissue. Adequacy was confirmed by MOSE (whitish core of more than 4 mm). Final cytology and histopathology (HPE) were compared for diagnostic accuracy.
One hundred fifty-five patients were included in the analysis during the study period (mean age 55.1+12.9 years; 60% male; 77% in pancreatic head; median size 3.7 cm). The final diagnosis was malignancy in 129, while 26 were negative for malignancy. Sensitivity and specificity for ROSE with cytology in detecting malignant SPLs were 96.9% and 100%, respectively. HPE with MOSE had sensitivity and specificity of 96.1% and 100%, respectively. A comparison of diagnostic accuracy showed no significant difference (P>0.99) between HPE with MOSE and ROSE with cytology, using an FNB needle.
MOSE is as good as ROSE in terms of diagnostic yield for solid pancreatic lesions sampled using newer-generation EUS biopsy needles.</description><identifier>ISSN: 1108-7471</identifier><identifier>ISSN: 1792-7463</identifier><identifier>EISSN: 1792-7463</identifier><identifier>DOI: 10.20524/aog.2023.0790</identifier><identifier>PMID: 37144017</identifier><language>eng</language><publisher>Greece: Hellenic Society of Gastroenterology</publisher><subject>Original</subject><ispartof>Annals of gastroenterology, 2023-01, Vol.36 (3), p.340-346</ispartof><rights>Copyright: © Hellenic Society of Gastroenterology.</rights><rights>Copyright: © Hellenic Society of Gastroenterology 2023</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC10152805/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC10152805/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,724,777,781,882,27905,27906,53772,53774</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/37144017$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sundaram, Sridhar</creatorcontrib><creatorcontrib>Chhanchure, Utkarsh</creatorcontrib><creatorcontrib>Patil, Prachi</creatorcontrib><creatorcontrib>Seth, Vishal</creatorcontrib><creatorcontrib>Mahajan, Akhil</creatorcontrib><creatorcontrib>Bal, Munita</creatorcontrib><creatorcontrib>Kaushal, Rajiv Kumar</creatorcontrib><creatorcontrib>Ramadwar, Mukta</creatorcontrib><creatorcontrib>Prabhudesai, Neelam</creatorcontrib><creatorcontrib>Bhandare, Manish</creatorcontrib><creatorcontrib>Shrikhande, Shailesh V</creatorcontrib><creatorcontrib>Mehta, Shaesta</creatorcontrib><title>Rapid on-site evaluation (ROSE) versus macroscopic on-site evaluation (MOSE) for endoscopic ultrasound-guided sampling of solid pancreatic lesions: a paired comparative analysis using newer-generation fine needle biopsy needles</title><title>Annals of gastroenterology</title><addtitle>Ann Gastroenterol</addtitle><description>Rapid on-site examination (ROSE) during endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) has been a subject of debate. We compared the yield of EUS-FNB with adequacy assessed using macroscopic on-site evaluation (MOSE), and smear cytology with adequacy confirmed by ROSE, acquired using the same needle.
Consecutive patients with solid pancreatic lesions (SPLs) who underwent EUS-FNB of pancreatic solid lesions between January 2021 and July 2022 were included. Demographic details, site and size of lesion, number of passes, and the diagnosis by cytology and histopathology of core tissue were noted. The first pass was used for ROSE adequacy assessment and was subsequently sent for cytological assessment. Additional passes were taken subsequently to acquire core tissue. Adequacy was confirmed by MOSE (whitish core of more than 4 mm). Final cytology and histopathology (HPE) were compared for diagnostic accuracy.
One hundred fifty-five patients were included in the analysis during the study period (mean age 55.1+12.9 years; 60% male; 77% in pancreatic head; median size 3.7 cm). The final diagnosis was malignancy in 129, while 26 were negative for malignancy. Sensitivity and specificity for ROSE with cytology in detecting malignant SPLs were 96.9% and 100%, respectively. HPE with MOSE had sensitivity and specificity of 96.1% and 100%, respectively. A comparison of diagnostic accuracy showed no significant difference (P>0.99) between HPE with MOSE and ROSE with cytology, using an FNB needle.
MOSE is as good as ROSE in terms of diagnostic yield for solid pancreatic lesions sampled using newer-generation EUS biopsy needles.</description><subject>Original</subject><issn>1108-7471</issn><issn>1792-7463</issn><issn>1792-7463</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNptkk1v1DAQhiMEoqVw5Yh8LIcsduLECRdUVeVDKqpU4GxNnEkwcuzgSRbt7-WP4O1uK5A4eTzz-J2x_WbZS8E3Ba8K-QbCmKKi3HDV8kfZqVBtkStZl49TLHiTYiVOsmdEPzivaiXl0-ykVEJKLtRp9vsWZtuz4HOyCzLcglthscGz89ubL1ev2RYjrcQmMDGQCbM1_4U_38FDiAx9fw-ubolAYfV9Pq62x54RTLOzfmRhYBRc6jyDNxGTimEOKWnRWwYpa2PCTZhmiKm4RQYe3I4ssZX2Ah5_YcxH9BgPIwzWY8pi75B1Nsy0O-7oefZkAEf44rieZd_eX329_Jhf33z4dHlxnZtS1kveqKor2gpUV5pBtaKuQVTQNsNQtXXNy0ZKk94YWlGYJhGNADCJrk0nEAYsz7J3B9157SbsDfp0fafnaCeIOx3A6n8r3n7XY9hqwUVVNLxKCudHhRh-rkiLniwZdA48hpV00QjeiqpUMqGbA7r_F4o4PPQRXN9ZQydr6L019N4a6cCrv6d7wO-9UP4Bpaa8Og</recordid><startdate>20230101</startdate><enddate>20230101</enddate><creator>Sundaram, Sridhar</creator><creator>Chhanchure, Utkarsh</creator><creator>Patil, Prachi</creator><creator>Seth, Vishal</creator><creator>Mahajan, Akhil</creator><creator>Bal, Munita</creator><creator>Kaushal, Rajiv Kumar</creator><creator>Ramadwar, Mukta</creator><creator>Prabhudesai, Neelam</creator><creator>Bhandare, Manish</creator><creator>Shrikhande, Shailesh V</creator><creator>Mehta, Shaesta</creator><general>Hellenic Society of Gastroenterology</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20230101</creationdate><title>Rapid on-site evaluation (ROSE) versus macroscopic on-site evaluation (MOSE) for endoscopic ultrasound-guided sampling of solid pancreatic lesions: a paired comparative analysis using newer-generation fine needle biopsy needles</title><author>Sundaram, Sridhar ; Chhanchure, Utkarsh ; Patil, Prachi ; Seth, Vishal ; Mahajan, Akhil ; Bal, Munita ; Kaushal, Rajiv Kumar ; Ramadwar, Mukta ; Prabhudesai, Neelam ; Bhandare, Manish ; Shrikhande, Shailesh V ; Mehta, Shaesta</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c346t-875b295a7b3cf79166a15a98ff596603844c790a912c8cf781aaca7b6cb1eafe3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Original</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sundaram, Sridhar</creatorcontrib><creatorcontrib>Chhanchure, Utkarsh</creatorcontrib><creatorcontrib>Patil, Prachi</creatorcontrib><creatorcontrib>Seth, Vishal</creatorcontrib><creatorcontrib>Mahajan, Akhil</creatorcontrib><creatorcontrib>Bal, Munita</creatorcontrib><creatorcontrib>Kaushal, Rajiv Kumar</creatorcontrib><creatorcontrib>Ramadwar, Mukta</creatorcontrib><creatorcontrib>Prabhudesai, Neelam</creatorcontrib><creatorcontrib>Bhandare, Manish</creatorcontrib><creatorcontrib>Shrikhande, Shailesh V</creatorcontrib><creatorcontrib>Mehta, Shaesta</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Annals of gastroenterology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sundaram, Sridhar</au><au>Chhanchure, Utkarsh</au><au>Patil, Prachi</au><au>Seth, Vishal</au><au>Mahajan, Akhil</au><au>Bal, Munita</au><au>Kaushal, Rajiv Kumar</au><au>Ramadwar, Mukta</au><au>Prabhudesai, Neelam</au><au>Bhandare, Manish</au><au>Shrikhande, Shailesh V</au><au>Mehta, Shaesta</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Rapid on-site evaluation (ROSE) versus macroscopic on-site evaluation (MOSE) for endoscopic ultrasound-guided sampling of solid pancreatic lesions: a paired comparative analysis using newer-generation fine needle biopsy needles</atitle><jtitle>Annals of gastroenterology</jtitle><addtitle>Ann Gastroenterol</addtitle><date>2023-01-01</date><risdate>2023</risdate><volume>36</volume><issue>3</issue><spage>340</spage><epage>346</epage><pages>340-346</pages><issn>1108-7471</issn><issn>1792-7463</issn><eissn>1792-7463</eissn><abstract>Rapid on-site examination (ROSE) during endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) has been a subject of debate. We compared the yield of EUS-FNB with adequacy assessed using macroscopic on-site evaluation (MOSE), and smear cytology with adequacy confirmed by ROSE, acquired using the same needle.
Consecutive patients with solid pancreatic lesions (SPLs) who underwent EUS-FNB of pancreatic solid lesions between January 2021 and July 2022 were included. Demographic details, site and size of lesion, number of passes, and the diagnosis by cytology and histopathology of core tissue were noted. The first pass was used for ROSE adequacy assessment and was subsequently sent for cytological assessment. Additional passes were taken subsequently to acquire core tissue. Adequacy was confirmed by MOSE (whitish core of more than 4 mm). Final cytology and histopathology (HPE) were compared for diagnostic accuracy.
One hundred fifty-five patients were included in the analysis during the study period (mean age 55.1+12.9 years; 60% male; 77% in pancreatic head; median size 3.7 cm). The final diagnosis was malignancy in 129, while 26 were negative for malignancy. Sensitivity and specificity for ROSE with cytology in detecting malignant SPLs were 96.9% and 100%, respectively. HPE with MOSE had sensitivity and specificity of 96.1% and 100%, respectively. A comparison of diagnostic accuracy showed no significant difference (P>0.99) between HPE with MOSE and ROSE with cytology, using an FNB needle.
MOSE is as good as ROSE in terms of diagnostic yield for solid pancreatic lesions sampled using newer-generation EUS biopsy needles.</abstract><cop>Greece</cop><pub>Hellenic Society of Gastroenterology</pub><pmid>37144017</pmid><doi>10.20524/aog.2023.0790</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1108-7471 |
ispartof | Annals of gastroenterology, 2023-01, Vol.36 (3), p.340-346 |
issn | 1108-7471 1792-7463 1792-7463 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_10152805 |
source | Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central Open Access; PubMed Central |
subjects | Original |
title | Rapid on-site evaluation (ROSE) versus macroscopic on-site evaluation (MOSE) for endoscopic ultrasound-guided sampling of solid pancreatic lesions: a paired comparative analysis using newer-generation fine needle biopsy needles |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-18T08%3A52%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Rapid%20on-site%20evaluation%20(ROSE)%20versus%20macroscopic%20on-site%20evaluation%20(MOSE)%20for%20endoscopic%20ultrasound-guided%20sampling%20of%20solid%20pancreatic%20lesions:%20a%20paired%20comparative%20analysis%20using%20newer-generation%20fine%20needle%20biopsy%20needles&rft.jtitle=Annals%20of%20gastroenterology&rft.au=Sundaram,%20Sridhar&rft.date=2023-01-01&rft.volume=36&rft.issue=3&rft.spage=340&rft.epage=346&rft.pages=340-346&rft.issn=1108-7471&rft.eissn=1792-7463&rft_id=info:doi/10.20524/aog.2023.0790&rft_dat=%3Cproquest_pubme%3E2810915374%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2810915374&rft_id=info:pmid/37144017&rfr_iscdi=true |