Clinically feasible B 1 field correction for multi-organ sodium imaging at 3 T

Sodium MRI allows the non-invasive quantification of intra-organ sodium concentration. RF inhomogeneity introduces uncertainty in this estimated concentration. B field corrections can be used to overcome some of these limitations. However, the low signal-to-noise ratio in sodium MRI makes accurate B...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:NMR in biomedicine 2023-02, Vol.36 (2), p.e4835
Hauptverfasser: Vaeggemose, Michael, Schulte, Rolf F, Laustsen, Christoffer
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 2
container_start_page e4835
container_title NMR in biomedicine
container_volume 36
creator Vaeggemose, Michael
Schulte, Rolf F
Laustsen, Christoffer
description Sodium MRI allows the non-invasive quantification of intra-organ sodium concentration. RF inhomogeneity introduces uncertainty in this estimated concentration. B field corrections can be used to overcome some of these limitations. However, the low signal-to-noise ratio in sodium MRI makes accurate B mapping in reasonable scan times challenging. The study aims to evaluate Bloch-Siegert off-resonance (BLOSI) B field correction for sodium MRI using a 3D Fermat looped, orthogonally encoded trajectories (FLORET) read-out trajectory. We propose a clinically feasible B field map correction method for sodium imaging at 3 T, evaluating five healthy subjects' brain, heart blood, kidneys, and thigh muscle. We scanned the subjects twice for repeatability measures and used sodium phantoms to determine organ total sodium concentration. Conventional proton scans were compared with sodium images for organ structural integrity. The BLOSI approach based on the 3D FLORET read-out trajectory was used in B field correction and 3D density-adapted radial acquisition for sodium imaging. Results indicate improvements in sodium imaging based on B field correction in a clinically feasible protocol. Improvements are determined in all organs by enhanced anatomical representation, organ homogeneity, and an increase in the total sodium concentration after applying a B field correction. The proposed BLOSI-based B field correction using a 3D FLORET read-out trajectory is clinically feasible for sodium imaging, which is shown in the brain, heart, kidney, and thigh muscle. This supports using fast B field mapping in the clinical setting.
doi_str_mv 10.1002/nbm.4835
format Article
fullrecord <record><control><sourceid>pubmed_cross</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_10078323</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>36115017</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1513-4fa21b44762fabe37d3557dfd69467b0416733016947491a4b2cf67c3c81bd973</originalsourceid><addsrcrecordid>eNpVkM9KAzEQh4MotlbBJ5AcvWzNJNnN7km0-A8KeqjnJckmayS7Kdmt0FuvvqZP4pZq0dMwzDe_GT6EzoFMgRB61apmynOWHqAxkKJIgBf0EI1JkdKE8ZyM0EnXvRNCcs7oMRqxDCAlIMboZeZd67T0fo2tkZ1T3uBbDNg64yusQ4xG9y602IaIm5XvXRJiLVvchcqtGuwaWbu2xrLH7GvzuThFR1b6zpz91Al6vb9bzB6T-fPD0-xmnmhIgSXcSgqKc5FRK5VhomJpKipbZQXPhCIcMsEYgaEVvADJFdU2E5rpHFRVCDZB17vc5Uo1ptKm7aP05TIOD8V1GaQr_09a91bW4aMchImcUTYkXO4SdAxdF43dLwPZUrQctJZbrQN68ffYHvz1yL4BWiBzcA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Clinically feasible B 1 field correction for multi-organ sodium imaging at 3 T</title><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><creator>Vaeggemose, Michael ; Schulte, Rolf F ; Laustsen, Christoffer</creator><creatorcontrib>Vaeggemose, Michael ; Schulte, Rolf F ; Laustsen, Christoffer</creatorcontrib><description>Sodium MRI allows the non-invasive quantification of intra-organ sodium concentration. RF inhomogeneity introduces uncertainty in this estimated concentration. B field corrections can be used to overcome some of these limitations. However, the low signal-to-noise ratio in sodium MRI makes accurate B mapping in reasonable scan times challenging. The study aims to evaluate Bloch-Siegert off-resonance (BLOSI) B field correction for sodium MRI using a 3D Fermat looped, orthogonally encoded trajectories (FLORET) read-out trajectory. We propose a clinically feasible B field map correction method for sodium imaging at 3 T, evaluating five healthy subjects' brain, heart blood, kidneys, and thigh muscle. We scanned the subjects twice for repeatability measures and used sodium phantoms to determine organ total sodium concentration. Conventional proton scans were compared with sodium images for organ structural integrity. The BLOSI approach based on the 3D FLORET read-out trajectory was used in B field correction and 3D density-adapted radial acquisition for sodium imaging. Results indicate improvements in sodium imaging based on B field correction in a clinically feasible protocol. Improvements are determined in all organs by enhanced anatomical representation, organ homogeneity, and an increase in the total sodium concentration after applying a B field correction. The proposed BLOSI-based B field correction using a 3D FLORET read-out trajectory is clinically feasible for sodium imaging, which is shown in the brain, heart, kidney, and thigh muscle. This supports using fast B field mapping in the clinical setting.</description><identifier>ISSN: 0952-3480</identifier><identifier>EISSN: 1099-1492</identifier><identifier>DOI: 10.1002/nbm.4835</identifier><identifier>PMID: 36115017</identifier><language>eng</language><publisher>England: John Wiley and Sons Inc</publisher><subject>Brain - diagnostic imaging ; Heart ; Humans ; Magnetic Resonance Imaging - methods ; Phantoms, Imaging ; Sodium</subject><ispartof>NMR in biomedicine, 2023-02, Vol.36 (2), p.e4835</ispartof><rights>2022 The Authors. NMR in Biomedicine published by John Wiley &amp; Sons Ltd.</rights><rights>2022 The Authors. published by John Wiley &amp; Sons Ltd.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c1513-4fa21b44762fabe37d3557dfd69467b0416733016947491a4b2cf67c3c81bd973</citedby><cites>FETCH-LOGICAL-c1513-4fa21b44762fabe37d3557dfd69467b0416733016947491a4b2cf67c3c81bd973</cites><orcidid>0000-0002-0317-2911 ; 0000-0001-7666-6819</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36115017$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Vaeggemose, Michael</creatorcontrib><creatorcontrib>Schulte, Rolf F</creatorcontrib><creatorcontrib>Laustsen, Christoffer</creatorcontrib><title>Clinically feasible B 1 field correction for multi-organ sodium imaging at 3 T</title><title>NMR in biomedicine</title><addtitle>NMR Biomed</addtitle><description>Sodium MRI allows the non-invasive quantification of intra-organ sodium concentration. RF inhomogeneity introduces uncertainty in this estimated concentration. B field corrections can be used to overcome some of these limitations. However, the low signal-to-noise ratio in sodium MRI makes accurate B mapping in reasonable scan times challenging. The study aims to evaluate Bloch-Siegert off-resonance (BLOSI) B field correction for sodium MRI using a 3D Fermat looped, orthogonally encoded trajectories (FLORET) read-out trajectory. We propose a clinically feasible B field map correction method for sodium imaging at 3 T, evaluating five healthy subjects' brain, heart blood, kidneys, and thigh muscle. We scanned the subjects twice for repeatability measures and used sodium phantoms to determine organ total sodium concentration. Conventional proton scans were compared with sodium images for organ structural integrity. The BLOSI approach based on the 3D FLORET read-out trajectory was used in B field correction and 3D density-adapted radial acquisition for sodium imaging. Results indicate improvements in sodium imaging based on B field correction in a clinically feasible protocol. Improvements are determined in all organs by enhanced anatomical representation, organ homogeneity, and an increase in the total sodium concentration after applying a B field correction. The proposed BLOSI-based B field correction using a 3D FLORET read-out trajectory is clinically feasible for sodium imaging, which is shown in the brain, heart, kidney, and thigh muscle. This supports using fast B field mapping in the clinical setting.</description><subject>Brain - diagnostic imaging</subject><subject>Heart</subject><subject>Humans</subject><subject>Magnetic Resonance Imaging - methods</subject><subject>Phantoms, Imaging</subject><subject>Sodium</subject><issn>0952-3480</issn><issn>1099-1492</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpVkM9KAzEQh4MotlbBJ5AcvWzNJNnN7km0-A8KeqjnJckmayS7Kdmt0FuvvqZP4pZq0dMwzDe_GT6EzoFMgRB61apmynOWHqAxkKJIgBf0EI1JkdKE8ZyM0EnXvRNCcs7oMRqxDCAlIMboZeZd67T0fo2tkZ1T3uBbDNg64yusQ4xG9y602IaIm5XvXRJiLVvchcqtGuwaWbu2xrLH7GvzuThFR1b6zpz91Al6vb9bzB6T-fPD0-xmnmhIgSXcSgqKc5FRK5VhomJpKipbZQXPhCIcMsEYgaEVvADJFdU2E5rpHFRVCDZB17vc5Uo1ptKm7aP05TIOD8V1GaQr_09a91bW4aMchImcUTYkXO4SdAxdF43dLwPZUrQctJZbrQN68ffYHvz1yL4BWiBzcA</recordid><startdate>202302</startdate><enddate>202302</enddate><creator>Vaeggemose, Michael</creator><creator>Schulte, Rolf F</creator><creator>Laustsen, Christoffer</creator><general>John Wiley and Sons Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0002-0317-2911</orcidid><orcidid>https://orcid.org/0000-0001-7666-6819</orcidid></search><sort><creationdate>202302</creationdate><title>Clinically feasible B 1 field correction for multi-organ sodium imaging at 3 T</title><author>Vaeggemose, Michael ; Schulte, Rolf F ; Laustsen, Christoffer</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1513-4fa21b44762fabe37d3557dfd69467b0416733016947491a4b2cf67c3c81bd973</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Brain - diagnostic imaging</topic><topic>Heart</topic><topic>Humans</topic><topic>Magnetic Resonance Imaging - methods</topic><topic>Phantoms, Imaging</topic><topic>Sodium</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Vaeggemose, Michael</creatorcontrib><creatorcontrib>Schulte, Rolf F</creatorcontrib><creatorcontrib>Laustsen, Christoffer</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>NMR in biomedicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Vaeggemose, Michael</au><au>Schulte, Rolf F</au><au>Laustsen, Christoffer</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Clinically feasible B 1 field correction for multi-organ sodium imaging at 3 T</atitle><jtitle>NMR in biomedicine</jtitle><addtitle>NMR Biomed</addtitle><date>2023-02</date><risdate>2023</risdate><volume>36</volume><issue>2</issue><spage>e4835</spage><pages>e4835-</pages><issn>0952-3480</issn><eissn>1099-1492</eissn><abstract>Sodium MRI allows the non-invasive quantification of intra-organ sodium concentration. RF inhomogeneity introduces uncertainty in this estimated concentration. B field corrections can be used to overcome some of these limitations. However, the low signal-to-noise ratio in sodium MRI makes accurate B mapping in reasonable scan times challenging. The study aims to evaluate Bloch-Siegert off-resonance (BLOSI) B field correction for sodium MRI using a 3D Fermat looped, orthogonally encoded trajectories (FLORET) read-out trajectory. We propose a clinically feasible B field map correction method for sodium imaging at 3 T, evaluating five healthy subjects' brain, heart blood, kidneys, and thigh muscle. We scanned the subjects twice for repeatability measures and used sodium phantoms to determine organ total sodium concentration. Conventional proton scans were compared with sodium images for organ structural integrity. The BLOSI approach based on the 3D FLORET read-out trajectory was used in B field correction and 3D density-adapted radial acquisition for sodium imaging. Results indicate improvements in sodium imaging based on B field correction in a clinically feasible protocol. Improvements are determined in all organs by enhanced anatomical representation, organ homogeneity, and an increase in the total sodium concentration after applying a B field correction. The proposed BLOSI-based B field correction using a 3D FLORET read-out trajectory is clinically feasible for sodium imaging, which is shown in the brain, heart, kidney, and thigh muscle. This supports using fast B field mapping in the clinical setting.</abstract><cop>England</cop><pub>John Wiley and Sons Inc</pub><pmid>36115017</pmid><doi>10.1002/nbm.4835</doi><orcidid>https://orcid.org/0000-0002-0317-2911</orcidid><orcidid>https://orcid.org/0000-0001-7666-6819</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0952-3480
ispartof NMR in biomedicine, 2023-02, Vol.36 (2), p.e4835
issn 0952-3480
1099-1492
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_10078323
source MEDLINE; Wiley Online Library Journals Frontfile Complete
subjects Brain - diagnostic imaging
Heart
Humans
Magnetic Resonance Imaging - methods
Phantoms, Imaging
Sodium
title Clinically feasible B 1 field correction for multi-organ sodium imaging at 3 T
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T02%3A55%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Clinically%20feasible%20B%201%20field%20correction%20for%20multi-organ%20sodium%20imaging%20at%203%E2%80%89T&rft.jtitle=NMR%20in%20biomedicine&rft.au=Vaeggemose,%20Michael&rft.date=2023-02&rft.volume=36&rft.issue=2&rft.spage=e4835&rft.pages=e4835-&rft.issn=0952-3480&rft.eissn=1099-1492&rft_id=info:doi/10.1002/nbm.4835&rft_dat=%3Cpubmed_cross%3E36115017%3C/pubmed_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/36115017&rfr_iscdi=true