Design and synthesis of a TICT-based red-emissive fluorescent probe for the rapid and selective detection of HSA in human biofluids and live cell imaging
Here, we report the design and synthesis of a D π A-based fluorescent probe, ( E )-4-(4-(dibutylamine)-2-hydroxystyryl)-1-methylquinolin-1-ium (DHMQ), which is nonfluorescent in ∼100% PBS buffer medium due to a twisted intra molecular charge transfer (TICT) phenomenon and it becomes highly fluoresce...
Gespeichert in:
Veröffentlicht in: | Journal of materials chemistry. B, Materials for biology and medicine Materials for biology and medicine, 2024-09, Vol.12 (35), p.8791-88 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 88 |
---|---|
container_issue | 35 |
container_start_page | 8791 |
container_title | Journal of materials chemistry. B, Materials for biology and medicine |
container_volume | 12 |
creator | Moni, Dolan Sasmal, Mihir Katarkar, Atul Basu, Anamika Ali, Mahammad |
description | Here, we report the design and synthesis of a D π A-based fluorescent probe, (
E
)-4-(4-(dibutylamine)-2-hydroxystyryl)-1-methylquinolin-1-ium (DHMQ), which is nonfluorescent in ∼100% PBS buffer medium due to a twisted intra molecular charge transfer (TICT) phenomenon and it becomes highly fluorescent (∼149 fold) in the presence of human serum albumin (HSA), owing to the restriction of its intramolecular free rotation inside the hydrophobic binding cavity of HSA. The site-selective fluorescence displacement assay and molecular docking studies clearly reveal that DHMQ selectively binds at subdomain IB of HSA. The 3
σ
/slope method was adopted to determine the limit of detection (LOD) value, which was as low as 2.39 nM in ∼100% PBS medium, indicating its high sensitivity towards HSA. The low dissociation constant value [
K
d
= (1.066 ± 0.017) μM] suggests a strong complexation between the DHMQ and HSA. Importantly, it has been demonstrated that DHMQ is capable of detecting HSA in real human serum and urine samples and was found to be suitable for live cell imaging of HSA.
A D π A-based probe, DHMQ, is nonfluorescent in ∼100% PBS due to its TICT behaviour, while it becomes highly fluorescent in the presence of HSA, owing to restriction of its intramolecular free rotation inside the hydrophobic cavity of HSA. |
doi_str_mv | 10.1039/d4tb01101e |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmed_primary_39145384</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3102671225</sourcerecordid><originalsourceid>FETCH-LOGICAL-c226t-d5a84f25a55c2c4908ab68d745079380709d48c5b3266a934f1c2f96cd3f15bd3</originalsourceid><addsrcrecordid>eNpdkUtLJDEUhYM4qDhuZq8E3IhQM3lWpZbaPkGYhS3Mrkglt9pIddImVYI_xX9rytYWJpvcm3z3cA8HoV-U_KaE13-sGFpCKaGwhfYYkaSoJFXbm5r820UHKT2RfBQtFRc7aJfXVEiuxB56u4DkFh5rb3F69cNjbhMOHdZ4fjubF61OYHEEW8DSpeReAHf9GCIkA37Aqxja_BIizpM46pWzaynowQwTbWGYquAn0Zv7M-w8fhyX2uPWhSzlbPqY6CfYQN9jt9QL5xc_0Y9O9wkOPu999HB1OZ_dFHd_r29nZ3eFYawcCiu1Eh2TWkrDjKiJ0m2pbCUkqWquSEVqK5SRLWdlqWsuOmpYV5fG8o7K1vJ9dLLWzV6eR0hDk41Oi2gPYUwNJzWnleRUZfT4P_QpjNHn7RpOCSsrypjM1OmaMjGkFKFrVjF7iq8NJc2UWXMh5ucfmV1m-OhTcmyXYDfoV0IZOFwDMZnN73fo_B30Z5rv</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3102671225</pqid></control><display><type>article</type><title>Design and synthesis of a TICT-based red-emissive fluorescent probe for the rapid and selective detection of HSA in human biofluids and live cell imaging</title><source>MEDLINE</source><source>Royal Society Of Chemistry Journals 2008-</source><creator>Moni, Dolan ; Sasmal, Mihir ; Katarkar, Atul ; Basu, Anamika ; Ali, Mahammad</creator><creatorcontrib>Moni, Dolan ; Sasmal, Mihir ; Katarkar, Atul ; Basu, Anamika ; Ali, Mahammad</creatorcontrib><description>Here, we report the design and synthesis of a D π A-based fluorescent probe, (
E
)-4-(4-(dibutylamine)-2-hydroxystyryl)-1-methylquinolin-1-ium (DHMQ), which is nonfluorescent in ∼100% PBS buffer medium due to a twisted intra molecular charge transfer (TICT) phenomenon and it becomes highly fluorescent (∼149 fold) in the presence of human serum albumin (HSA), owing to the restriction of its intramolecular free rotation inside the hydrophobic binding cavity of HSA. The site-selective fluorescence displacement assay and molecular docking studies clearly reveal that DHMQ selectively binds at subdomain IB of HSA. The 3
σ
/slope method was adopted to determine the limit of detection (LOD) value, which was as low as 2.39 nM in ∼100% PBS medium, indicating its high sensitivity towards HSA. The low dissociation constant value [
K
d
= (1.066 ± 0.017) μM] suggests a strong complexation between the DHMQ and HSA. Importantly, it has been demonstrated that DHMQ is capable of detecting HSA in real human serum and urine samples and was found to be suitable for live cell imaging of HSA.
A D π A-based probe, DHMQ, is nonfluorescent in ∼100% PBS due to its TICT behaviour, while it becomes highly fluorescent in the presence of HSA, owing to restriction of its intramolecular free rotation inside the hydrophobic cavity of HSA.</description><identifier>ISSN: 2050-750X</identifier><identifier>ISSN: 2050-7518</identifier><identifier>EISSN: 2050-7518</identifier><identifier>DOI: 10.1039/d4tb01101e</identifier><identifier>PMID: 39145384</identifier><language>eng</language><publisher>England: Royal Society of Chemistry</publisher><subject>Charge transfer ; Fluorescent Dyes - chemical synthesis ; Fluorescent Dyes - chemistry ; Fluorescent indicators ; Human serum albumin ; Humans ; Hydrophobicity ; Molecular docking ; Molecular Docking Simulation ; Molecular Structure ; Optical Imaging ; Serum albumin ; Serum Albumin, Human - analysis ; Serum Albumin, Human - metabolism ; Synthesis</subject><ispartof>Journal of materials chemistry. B, Materials for biology and medicine, 2024-09, Vol.12 (35), p.8791-88</ispartof><rights>Copyright Royal Society of Chemistry 2024</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c226t-d5a84f25a55c2c4908ab68d745079380709d48c5b3266a934f1c2f96cd3f15bd3</cites><orcidid>0000-0003-0756-0468 ; 0000-0002-4284-7774</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,778,782,27911,27912</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39145384$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Moni, Dolan</creatorcontrib><creatorcontrib>Sasmal, Mihir</creatorcontrib><creatorcontrib>Katarkar, Atul</creatorcontrib><creatorcontrib>Basu, Anamika</creatorcontrib><creatorcontrib>Ali, Mahammad</creatorcontrib><title>Design and synthesis of a TICT-based red-emissive fluorescent probe for the rapid and selective detection of HSA in human biofluids and live cell imaging</title><title>Journal of materials chemistry. B, Materials for biology and medicine</title><addtitle>J Mater Chem B</addtitle><description>Here, we report the design and synthesis of a D π A-based fluorescent probe, (
E
)-4-(4-(dibutylamine)-2-hydroxystyryl)-1-methylquinolin-1-ium (DHMQ), which is nonfluorescent in ∼100% PBS buffer medium due to a twisted intra molecular charge transfer (TICT) phenomenon and it becomes highly fluorescent (∼149 fold) in the presence of human serum albumin (HSA), owing to the restriction of its intramolecular free rotation inside the hydrophobic binding cavity of HSA. The site-selective fluorescence displacement assay and molecular docking studies clearly reveal that DHMQ selectively binds at subdomain IB of HSA. The 3
σ
/slope method was adopted to determine the limit of detection (LOD) value, which was as low as 2.39 nM in ∼100% PBS medium, indicating its high sensitivity towards HSA. The low dissociation constant value [
K
d
= (1.066 ± 0.017) μM] suggests a strong complexation between the DHMQ and HSA. Importantly, it has been demonstrated that DHMQ is capable of detecting HSA in real human serum and urine samples and was found to be suitable for live cell imaging of HSA.
A D π A-based probe, DHMQ, is nonfluorescent in ∼100% PBS due to its TICT behaviour, while it becomes highly fluorescent in the presence of HSA, owing to restriction of its intramolecular free rotation inside the hydrophobic cavity of HSA.</description><subject>Charge transfer</subject><subject>Fluorescent Dyes - chemical synthesis</subject><subject>Fluorescent Dyes - chemistry</subject><subject>Fluorescent indicators</subject><subject>Human serum albumin</subject><subject>Humans</subject><subject>Hydrophobicity</subject><subject>Molecular docking</subject><subject>Molecular Docking Simulation</subject><subject>Molecular Structure</subject><subject>Optical Imaging</subject><subject>Serum albumin</subject><subject>Serum Albumin, Human - analysis</subject><subject>Serum Albumin, Human - metabolism</subject><subject>Synthesis</subject><issn>2050-750X</issn><issn>2050-7518</issn><issn>2050-7518</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpdkUtLJDEUhYM4qDhuZq8E3IhQM3lWpZbaPkGYhS3Mrkglt9pIddImVYI_xX9rytYWJpvcm3z3cA8HoV-U_KaE13-sGFpCKaGwhfYYkaSoJFXbm5r820UHKT2RfBQtFRc7aJfXVEiuxB56u4DkFh5rb3F69cNjbhMOHdZ4fjubF61OYHEEW8DSpeReAHf9GCIkA37Aqxja_BIizpM46pWzaynowQwTbWGYquAn0Zv7M-w8fhyX2uPWhSzlbPqY6CfYQN9jt9QL5xc_0Y9O9wkOPu999HB1OZ_dFHd_r29nZ3eFYawcCiu1Eh2TWkrDjKiJ0m2pbCUkqWquSEVqK5SRLWdlqWsuOmpYV5fG8o7K1vJ9dLLWzV6eR0hDk41Oi2gPYUwNJzWnleRUZfT4P_QpjNHn7RpOCSsrypjM1OmaMjGkFKFrVjF7iq8NJc2UWXMh5ucfmV1m-OhTcmyXYDfoV0IZOFwDMZnN73fo_B30Z5rv</recordid><startdate>20240911</startdate><enddate>20240911</enddate><creator>Moni, Dolan</creator><creator>Sasmal, Mihir</creator><creator>Katarkar, Atul</creator><creator>Basu, Anamika</creator><creator>Ali, Mahammad</creator><general>Royal Society of Chemistry</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-0756-0468</orcidid><orcidid>https://orcid.org/0000-0002-4284-7774</orcidid></search><sort><creationdate>20240911</creationdate><title>Design and synthesis of a TICT-based red-emissive fluorescent probe for the rapid and selective detection of HSA in human biofluids and live cell imaging</title><author>Moni, Dolan ; Sasmal, Mihir ; Katarkar, Atul ; Basu, Anamika ; Ali, Mahammad</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c226t-d5a84f25a55c2c4908ab68d745079380709d48c5b3266a934f1c2f96cd3f15bd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Charge transfer</topic><topic>Fluorescent Dyes - chemical synthesis</topic><topic>Fluorescent Dyes - chemistry</topic><topic>Fluorescent indicators</topic><topic>Human serum albumin</topic><topic>Humans</topic><topic>Hydrophobicity</topic><topic>Molecular docking</topic><topic>Molecular Docking Simulation</topic><topic>Molecular Structure</topic><topic>Optical Imaging</topic><topic>Serum albumin</topic><topic>Serum Albumin, Human - analysis</topic><topic>Serum Albumin, Human - metabolism</topic><topic>Synthesis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Moni, Dolan</creatorcontrib><creatorcontrib>Sasmal, Mihir</creatorcontrib><creatorcontrib>Katarkar, Atul</creatorcontrib><creatorcontrib>Basu, Anamika</creatorcontrib><creatorcontrib>Ali, Mahammad</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of materials chemistry. B, Materials for biology and medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Moni, Dolan</au><au>Sasmal, Mihir</au><au>Katarkar, Atul</au><au>Basu, Anamika</au><au>Ali, Mahammad</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Design and synthesis of a TICT-based red-emissive fluorescent probe for the rapid and selective detection of HSA in human biofluids and live cell imaging</atitle><jtitle>Journal of materials chemistry. B, Materials for biology and medicine</jtitle><addtitle>J Mater Chem B</addtitle><date>2024-09-11</date><risdate>2024</risdate><volume>12</volume><issue>35</issue><spage>8791</spage><epage>88</epage><pages>8791-88</pages><issn>2050-750X</issn><issn>2050-7518</issn><eissn>2050-7518</eissn><abstract>Here, we report the design and synthesis of a D π A-based fluorescent probe, (
E
)-4-(4-(dibutylamine)-2-hydroxystyryl)-1-methylquinolin-1-ium (DHMQ), which is nonfluorescent in ∼100% PBS buffer medium due to a twisted intra molecular charge transfer (TICT) phenomenon and it becomes highly fluorescent (∼149 fold) in the presence of human serum albumin (HSA), owing to the restriction of its intramolecular free rotation inside the hydrophobic binding cavity of HSA. The site-selective fluorescence displacement assay and molecular docking studies clearly reveal that DHMQ selectively binds at subdomain IB of HSA. The 3
σ
/slope method was adopted to determine the limit of detection (LOD) value, which was as low as 2.39 nM in ∼100% PBS medium, indicating its high sensitivity towards HSA. The low dissociation constant value [
K
d
= (1.066 ± 0.017) μM] suggests a strong complexation between the DHMQ and HSA. Importantly, it has been demonstrated that DHMQ is capable of detecting HSA in real human serum and urine samples and was found to be suitable for live cell imaging of HSA.
A D π A-based probe, DHMQ, is nonfluorescent in ∼100% PBS due to its TICT behaviour, while it becomes highly fluorescent in the presence of HSA, owing to restriction of its intramolecular free rotation inside the hydrophobic cavity of HSA.</abstract><cop>England</cop><pub>Royal Society of Chemistry</pub><pmid>39145384</pmid><doi>10.1039/d4tb01101e</doi><tpages>1</tpages><orcidid>https://orcid.org/0000-0003-0756-0468</orcidid><orcidid>https://orcid.org/0000-0002-4284-7774</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2050-750X |
ispartof | Journal of materials chemistry. B, Materials for biology and medicine, 2024-09, Vol.12 (35), p.8791-88 |
issn | 2050-750X 2050-7518 2050-7518 |
language | eng |
recordid | cdi_pubmed_primary_39145384 |
source | MEDLINE; Royal Society Of Chemistry Journals 2008- |
subjects | Charge transfer Fluorescent Dyes - chemical synthesis Fluorescent Dyes - chemistry Fluorescent indicators Human serum albumin Humans Hydrophobicity Molecular docking Molecular Docking Simulation Molecular Structure Optical Imaging Serum albumin Serum Albumin, Human - analysis Serum Albumin, Human - metabolism Synthesis |
title | Design and synthesis of a TICT-based red-emissive fluorescent probe for the rapid and selective detection of HSA in human biofluids and live cell imaging |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T23%3A04%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Design%20and%20synthesis%20of%20a%20TICT-based%20red-emissive%20fluorescent%20probe%20for%20the%20rapid%20and%20selective%20detection%20of%20HSA%20in%20human%20biofluids%20and%20live%20cell%20imaging&rft.jtitle=Journal%20of%20materials%20chemistry.%20B,%20Materials%20for%20biology%20and%20medicine&rft.au=Moni,%20Dolan&rft.date=2024-09-11&rft.volume=12&rft.issue=35&rft.spage=8791&rft.epage=88&rft.pages=8791-88&rft.issn=2050-750X&rft.eissn=2050-7518&rft_id=info:doi/10.1039/d4tb01101e&rft_dat=%3Cproquest_pubme%3E3102671225%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3102671225&rft_id=info:pmid/39145384&rfr_iscdi=true |