Study of a method for theoretical calculation of the efficiency of a LaBr 3 (Ce) for detecting gamma-rays from point sources

A theoretical model for calculating the full-energy peak efficiency of scintillator detector is proposed in this paper. The effective penetration distance of gamma-rays in Ø3.81cm × 3.81 cm LaBr (Ce) crystal, aluminum shell and MgO reflector is analyzed. The calculation model for point source detect...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied radiation and isotopes 2024-07, Vol.212, p.111446
Hauptverfasser: Ye, Erlei, Shen, Chunxia, Nan, Hongjie, Lai, Yongfang
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page 111446
container_title Applied radiation and isotopes
container_volume 212
creator Ye, Erlei
Shen, Chunxia
Nan, Hongjie
Lai, Yongfang
description A theoretical model for calculating the full-energy peak efficiency of scintillator detector is proposed in this paper. The effective penetration distance of gamma-rays in Ø3.81cm × 3.81 cm LaBr (Ce) crystal, aluminum shell and MgO reflector is analyzed. The calculation model for point source detection efficiency is derived, and the attenuation of gamma-rays in the detector shell is computed by theoretical calculation method. This method is used to calculate the efficiency of LaBr (Ce) with a size of Ø3.81 × 3.81 cm for detecting gamma-rays from point sources of Cs and Co located in different positions. Compared with experimental data and Monte Carlo (MC) simulation results, the maximum relative deviation is less than 5%. The attenuation of gamma-rays with an energy of 60 keV is more than 50%. The fitted efficiency calibration curve in the energy range of 60 keV-1500 keV is in good agreement with the simulation results. The results show that this method is suitable for calculating the efficiency of the LaBr (Ce) detector using point sources, especially for analyzing low-energy gamma ray sources. By taking into account the attenuation of the gamma-rays by the detector shell, the measurement accuracy can be effectively improved. The proposed method can be extended for the efficiency calibration of scintillator detectors with various shapes and provides a new approach for 'source-less' efficiency calibration of detectors.
doi_str_mv 10.1016/j.apradiso.2024.111446
format Article
fullrecord <record><control><sourceid>pubmed</sourceid><recordid>TN_cdi_pubmed_primary_39043060</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>39043060</sourcerecordid><originalsourceid>FETCH-pubmed_primary_390430603</originalsourceid><addsrcrecordid>eNqFjrFOwzAURS0kRAvlF6o3wpDwnFghWalADN1gr17t59ZVHEe2M0Ti4ymozAxXd7jnSFeItcRSomyeTiWNkYxLoaywUqWUUqnmSixl-1wVXYu4ELcpnRBRtV11IxZ1h6rGBpfi6yNPZoZggcBzPgYDNkTIRw6Rs9PUwzl66im7MPxw5wnYWqcdD_pibuklQg0PG3781Q1n1tkNBziQ91REmhPYGDyMwQ0ZUpii5rQS15b6xPeXvhPrt9fPzXsxTnvPZjdG5ynOu7-79b_AN-K8Uvw</addsrcrecordid><sourcetype>Index Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Study of a method for theoretical calculation of the efficiency of a LaBr 3 (Ce) for detecting gamma-rays from point sources</title><source>Elsevier ScienceDirect Journals</source><creator>Ye, Erlei ; Shen, Chunxia ; Nan, Hongjie ; Lai, Yongfang</creator><creatorcontrib>Ye, Erlei ; Shen, Chunxia ; Nan, Hongjie ; Lai, Yongfang</creatorcontrib><description>A theoretical model for calculating the full-energy peak efficiency of scintillator detector is proposed in this paper. The effective penetration distance of gamma-rays in Ø3.81cm × 3.81 cm LaBr (Ce) crystal, aluminum shell and MgO reflector is analyzed. The calculation model for point source detection efficiency is derived, and the attenuation of gamma-rays in the detector shell is computed by theoretical calculation method. This method is used to calculate the efficiency of LaBr (Ce) with a size of Ø3.81 × 3.81 cm for detecting gamma-rays from point sources of Cs and Co located in different positions. Compared with experimental data and Monte Carlo (MC) simulation results, the maximum relative deviation is less than 5%. The attenuation of gamma-rays with an energy of 60 keV is more than 50%. The fitted efficiency calibration curve in the energy range of 60 keV-1500 keV is in good agreement with the simulation results. The results show that this method is suitable for calculating the efficiency of the LaBr (Ce) detector using point sources, especially for analyzing low-energy gamma ray sources. By taking into account the attenuation of the gamma-rays by the detector shell, the measurement accuracy can be effectively improved. The proposed method can be extended for the efficiency calibration of scintillator detectors with various shapes and provides a new approach for 'source-less' efficiency calibration of detectors.</description><identifier>EISSN: 1872-9800</identifier><identifier>DOI: 10.1016/j.apradiso.2024.111446</identifier><identifier>PMID: 39043060</identifier><language>eng</language><publisher>England</publisher><ispartof>Applied radiation and isotopes, 2024-07, Vol.212, p.111446</ispartof><rights>Copyright © 2024 Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39043060$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ye, Erlei</creatorcontrib><creatorcontrib>Shen, Chunxia</creatorcontrib><creatorcontrib>Nan, Hongjie</creatorcontrib><creatorcontrib>Lai, Yongfang</creatorcontrib><title>Study of a method for theoretical calculation of the efficiency of a LaBr 3 (Ce) for detecting gamma-rays from point sources</title><title>Applied radiation and isotopes</title><addtitle>Appl Radiat Isot</addtitle><description>A theoretical model for calculating the full-energy peak efficiency of scintillator detector is proposed in this paper. The effective penetration distance of gamma-rays in Ø3.81cm × 3.81 cm LaBr (Ce) crystal, aluminum shell and MgO reflector is analyzed. The calculation model for point source detection efficiency is derived, and the attenuation of gamma-rays in the detector shell is computed by theoretical calculation method. This method is used to calculate the efficiency of LaBr (Ce) with a size of Ø3.81 × 3.81 cm for detecting gamma-rays from point sources of Cs and Co located in different positions. Compared with experimental data and Monte Carlo (MC) simulation results, the maximum relative deviation is less than 5%. The attenuation of gamma-rays with an energy of 60 keV is more than 50%. The fitted efficiency calibration curve in the energy range of 60 keV-1500 keV is in good agreement with the simulation results. The results show that this method is suitable for calculating the efficiency of the LaBr (Ce) detector using point sources, especially for analyzing low-energy gamma ray sources. By taking into account the attenuation of the gamma-rays by the detector shell, the measurement accuracy can be effectively improved. The proposed method can be extended for the efficiency calibration of scintillator detectors with various shapes and provides a new approach for 'source-less' efficiency calibration of detectors.</description><issn>1872-9800</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNqFjrFOwzAURS0kRAvlF6o3wpDwnFghWalADN1gr17t59ZVHEe2M0Ti4ymozAxXd7jnSFeItcRSomyeTiWNkYxLoaywUqWUUqnmSixl-1wVXYu4ELcpnRBRtV11IxZ1h6rGBpfi6yNPZoZggcBzPgYDNkTIRw6Rs9PUwzl66im7MPxw5wnYWqcdD_pibuklQg0PG3781Q1n1tkNBziQ91REmhPYGDyMwQ0ZUpii5rQS15b6xPeXvhPrt9fPzXsxTnvPZjdG5ynOu7-79b_AN-K8Uvw</recordid><startdate>20240714</startdate><enddate>20240714</enddate><creator>Ye, Erlei</creator><creator>Shen, Chunxia</creator><creator>Nan, Hongjie</creator><creator>Lai, Yongfang</creator><scope>NPM</scope></search><sort><creationdate>20240714</creationdate><title>Study of a method for theoretical calculation of the efficiency of a LaBr 3 (Ce) for detecting gamma-rays from point sources</title><author>Ye, Erlei ; Shen, Chunxia ; Nan, Hongjie ; Lai, Yongfang</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-pubmed_primary_390430603</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ye, Erlei</creatorcontrib><creatorcontrib>Shen, Chunxia</creatorcontrib><creatorcontrib>Nan, Hongjie</creatorcontrib><creatorcontrib>Lai, Yongfang</creatorcontrib><collection>PubMed</collection><jtitle>Applied radiation and isotopes</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ye, Erlei</au><au>Shen, Chunxia</au><au>Nan, Hongjie</au><au>Lai, Yongfang</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Study of a method for theoretical calculation of the efficiency of a LaBr 3 (Ce) for detecting gamma-rays from point sources</atitle><jtitle>Applied radiation and isotopes</jtitle><addtitle>Appl Radiat Isot</addtitle><date>2024-07-14</date><risdate>2024</risdate><volume>212</volume><spage>111446</spage><pages>111446-</pages><eissn>1872-9800</eissn><abstract>A theoretical model for calculating the full-energy peak efficiency of scintillator detector is proposed in this paper. The effective penetration distance of gamma-rays in Ø3.81cm × 3.81 cm LaBr (Ce) crystal, aluminum shell and MgO reflector is analyzed. The calculation model for point source detection efficiency is derived, and the attenuation of gamma-rays in the detector shell is computed by theoretical calculation method. This method is used to calculate the efficiency of LaBr (Ce) with a size of Ø3.81 × 3.81 cm for detecting gamma-rays from point sources of Cs and Co located in different positions. Compared with experimental data and Monte Carlo (MC) simulation results, the maximum relative deviation is less than 5%. The attenuation of gamma-rays with an energy of 60 keV is more than 50%. The fitted efficiency calibration curve in the energy range of 60 keV-1500 keV is in good agreement with the simulation results. The results show that this method is suitable for calculating the efficiency of the LaBr (Ce) detector using point sources, especially for analyzing low-energy gamma ray sources. By taking into account the attenuation of the gamma-rays by the detector shell, the measurement accuracy can be effectively improved. The proposed method can be extended for the efficiency calibration of scintillator detectors with various shapes and provides a new approach for 'source-less' efficiency calibration of detectors.</abstract><cop>England</cop><pmid>39043060</pmid><doi>10.1016/j.apradiso.2024.111446</doi></addata></record>
fulltext fulltext
identifier EISSN: 1872-9800
ispartof Applied radiation and isotopes, 2024-07, Vol.212, p.111446
issn 1872-9800
language eng
recordid cdi_pubmed_primary_39043060
source Elsevier ScienceDirect Journals
title Study of a method for theoretical calculation of the efficiency of a LaBr 3 (Ce) for detecting gamma-rays from point sources
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T01%3A58%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Study%20of%20a%20method%20for%20theoretical%20calculation%20of%20the%20efficiency%20of%20a%20LaBr%203%20(Ce)%20for%20detecting%20gamma-rays%20from%20point%20sources&rft.jtitle=Applied%20radiation%20and%20isotopes&rft.au=Ye,%20Erlei&rft.date=2024-07-14&rft.volume=212&rft.spage=111446&rft.pages=111446-&rft.eissn=1872-9800&rft_id=info:doi/10.1016/j.apradiso.2024.111446&rft_dat=%3Cpubmed%3E39043060%3C/pubmed%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/39043060&rfr_iscdi=true