Quantitative assessment of cardiac 123 iodo-metaiodobenzylguanidine SPECT/CT in patients with arrhythmogenic right ventricular cardiomyopathy: Novel insight in disease monitoring

The heart-to-mediastinum ratio (H/M-Ratio) of iodo-metaiodobenzylguanidine ( I-MIBG) represents state-of-the-art assessment for sympathetic dysfunction in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to evaluate quantitative reconstruction of I-MIBG uptake an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of nuclear cardiology 2024-09, Vol.39, p.101911
Hauptverfasser: Hagen, Johannes M, Zacherl, Mathias J, Brendel, Matthias, Clauß, Sebastian, Kääb, Stefan, Bartenstein, Peter, Todica, Andrei, Böning, Guido, Fischer, Maximilian
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page 101911
container_title Journal of nuclear cardiology
container_volume 39
creator Hagen, Johannes M
Zacherl, Mathias J
Brendel, Matthias
Clauß, Sebastian
Kääb, Stefan
Bartenstein, Peter
Todica, Andrei
Böning, Guido
Fischer, Maximilian
description The heart-to-mediastinum ratio (H/M-Ratio) of iodo-metaiodobenzylguanidine ( I-MIBG) represents state-of-the-art assessment for sympathetic dysfunction in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to evaluate quantitative reconstruction of I-MIBG uptake and to demonstrate its correlation with echocardiographic parameters. Cardiac innervation was assessed in 23 patients diagnosed with definite ARVC or borderline ARVC and 12 patients with other cardiac disease presenting arrhythmia, using quantitative I-MIBG Single Photon Emission Computed Tomography/Computed Tomography (SPECT/CT) imaging. Tracer uptake was evaluated in the left (LV) and right ventricle (RV) based on a CT scan after quantitative image reconstruction. The relationship between tracer uptake and echocardiographic parameter data was examined. Absolute quantification of I-MIBG uptake in the LV and RV is feasible and correlates accurately with the gold standard H/M Ratio. When comparing sensitivity and specificity, the area under the curve (AUC) favors standardized uptake value (SUV) of the RV over the right-ventricle-to-mediastinum-ratio (RV/M-Ratio) for diagnosing ARVC. A reduced RV-SUV in patients with definite ARVC is associated with reduced RV function. RV polar maps revealed globally reduced I-MIBG uptake without segment-specific reduction in the RV. Quantitative I-MIBG SPECT in ARCV patients offers robust potential for clinical reporting and demonstrates a significant correlation with RV function. Segmental RV analysis needs to be evaluated in larger samples. In summary, cardiac I-MIBG imaging using SUV could facilitate image-guided therapy in patients diagnosed with ARVC.
doi_str_mv 10.1016/j.nuclcard.2024.101911
format Article
fullrecord <record><control><sourceid>pubmed</sourceid><recordid>TN_cdi_pubmed_primary_39009215</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>39009215</sourcerecordid><originalsourceid>FETCH-pubmed_primary_390092153</originalsourceid><addsrcrecordid>eNqFj01OwzAQhS0kRMvPFaq5QFI7IZXCNipihUBkX7nJNJkqtiPbCTLH4oQ4_KxZzdPMe9_TMLYRPBVc7LbnVE_N0EjbphnP7pdlKcQFW4siz5JdUYgVu3buzDkv87K8Yqu8jDITxZp9vk5Se_LS04wgnUPnFGoP5gQLkWQDIsuBTGsShV4u4oj6IwxdTFJLGuHtZV_V26oG0jBGUsw7eCffg7S2D75XpkNNDVjqeg9zvFtqpkHanw6jgom5PjzAs5lxiBz37Yy8lhxKh6CMJm8s6e6WXZ7k4PDud96wzeO-rp6ScToqbA-jJSVtOPw9mf9r-ALtB2ny</addsrcrecordid><sourcetype>Index Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Quantitative assessment of cardiac 123 iodo-metaiodobenzylguanidine SPECT/CT in patients with arrhythmogenic right ventricular cardiomyopathy: Novel insight in disease monitoring</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Hagen, Johannes M ; Zacherl, Mathias J ; Brendel, Matthias ; Clauß, Sebastian ; Kääb, Stefan ; Bartenstein, Peter ; Todica, Andrei ; Böning, Guido ; Fischer, Maximilian</creator><creatorcontrib>Hagen, Johannes M ; Zacherl, Mathias J ; Brendel, Matthias ; Clauß, Sebastian ; Kääb, Stefan ; Bartenstein, Peter ; Todica, Andrei ; Böning, Guido ; Fischer, Maximilian</creatorcontrib><description>The heart-to-mediastinum ratio (H/M-Ratio) of iodo-metaiodobenzylguanidine ( I-MIBG) represents state-of-the-art assessment for sympathetic dysfunction in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to evaluate quantitative reconstruction of I-MIBG uptake and to demonstrate its correlation with echocardiographic parameters. Cardiac innervation was assessed in 23 patients diagnosed with definite ARVC or borderline ARVC and 12 patients with other cardiac disease presenting arrhythmia, using quantitative I-MIBG Single Photon Emission Computed Tomography/Computed Tomography (SPECT/CT) imaging. Tracer uptake was evaluated in the left (LV) and right ventricle (RV) based on a CT scan after quantitative image reconstruction. The relationship between tracer uptake and echocardiographic parameter data was examined. Absolute quantification of I-MIBG uptake in the LV and RV is feasible and correlates accurately with the gold standard H/M Ratio. When comparing sensitivity and specificity, the area under the curve (AUC) favors standardized uptake value (SUV) of the RV over the right-ventricle-to-mediastinum-ratio (RV/M-Ratio) for diagnosing ARVC. A reduced RV-SUV in patients with definite ARVC is associated with reduced RV function. RV polar maps revealed globally reduced I-MIBG uptake without segment-specific reduction in the RV. Quantitative I-MIBG SPECT in ARCV patients offers robust potential for clinical reporting and demonstrates a significant correlation with RV function. Segmental RV analysis needs to be evaluated in larger samples. In summary, cardiac I-MIBG imaging using SUV could facilitate image-guided therapy in patients diagnosed with ARVC.</description><identifier>EISSN: 1532-6551</identifier><identifier>DOI: 10.1016/j.nuclcard.2024.101911</identifier><identifier>PMID: 39009215</identifier><language>eng</language><publisher>United States</publisher><subject>3-Iodobenzylguanidine ; Adult ; Aged ; Arrhythmogenic Right Ventricular Dysplasia - diagnostic imaging ; Echocardiography - methods ; Female ; Heart - diagnostic imaging ; Heart Ventricles - diagnostic imaging ; Humans ; Male ; Middle Aged ; Radiopharmaceuticals ; Single Photon Emission Computed Tomography Computed Tomography - methods</subject><ispartof>Journal of nuclear cardiology, 2024-09, Vol.39, p.101911</ispartof><rights>Copyright © 2024 The Authors. Published by Elsevier Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39009215$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hagen, Johannes M</creatorcontrib><creatorcontrib>Zacherl, Mathias J</creatorcontrib><creatorcontrib>Brendel, Matthias</creatorcontrib><creatorcontrib>Clauß, Sebastian</creatorcontrib><creatorcontrib>Kääb, Stefan</creatorcontrib><creatorcontrib>Bartenstein, Peter</creatorcontrib><creatorcontrib>Todica, Andrei</creatorcontrib><creatorcontrib>Böning, Guido</creatorcontrib><creatorcontrib>Fischer, Maximilian</creatorcontrib><title>Quantitative assessment of cardiac 123 iodo-metaiodobenzylguanidine SPECT/CT in patients with arrhythmogenic right ventricular cardiomyopathy: Novel insight in disease monitoring</title><title>Journal of nuclear cardiology</title><addtitle>J Nucl Cardiol</addtitle><description>The heart-to-mediastinum ratio (H/M-Ratio) of iodo-metaiodobenzylguanidine ( I-MIBG) represents state-of-the-art assessment for sympathetic dysfunction in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to evaluate quantitative reconstruction of I-MIBG uptake and to demonstrate its correlation with echocardiographic parameters. Cardiac innervation was assessed in 23 patients diagnosed with definite ARVC or borderline ARVC and 12 patients with other cardiac disease presenting arrhythmia, using quantitative I-MIBG Single Photon Emission Computed Tomography/Computed Tomography (SPECT/CT) imaging. Tracer uptake was evaluated in the left (LV) and right ventricle (RV) based on a CT scan after quantitative image reconstruction. The relationship between tracer uptake and echocardiographic parameter data was examined. Absolute quantification of I-MIBG uptake in the LV and RV is feasible and correlates accurately with the gold standard H/M Ratio. When comparing sensitivity and specificity, the area under the curve (AUC) favors standardized uptake value (SUV) of the RV over the right-ventricle-to-mediastinum-ratio (RV/M-Ratio) for diagnosing ARVC. A reduced RV-SUV in patients with definite ARVC is associated with reduced RV function. RV polar maps revealed globally reduced I-MIBG uptake without segment-specific reduction in the RV. Quantitative I-MIBG SPECT in ARCV patients offers robust potential for clinical reporting and demonstrates a significant correlation with RV function. Segmental RV analysis needs to be evaluated in larger samples. In summary, cardiac I-MIBG imaging using SUV could facilitate image-guided therapy in patients diagnosed with ARVC.</description><subject>3-Iodobenzylguanidine</subject><subject>Adult</subject><subject>Aged</subject><subject>Arrhythmogenic Right Ventricular Dysplasia - diagnostic imaging</subject><subject>Echocardiography - methods</subject><subject>Female</subject><subject>Heart - diagnostic imaging</subject><subject>Heart Ventricles - diagnostic imaging</subject><subject>Humans</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Radiopharmaceuticals</subject><subject>Single Photon Emission Computed Tomography Computed Tomography - methods</subject><issn>1532-6551</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFj01OwzAQhS0kRMvPFaq5QFI7IZXCNipihUBkX7nJNJkqtiPbCTLH4oQ4_KxZzdPMe9_TMLYRPBVc7LbnVE_N0EjbphnP7pdlKcQFW4siz5JdUYgVu3buzDkv87K8Yqu8jDITxZp9vk5Se_LS04wgnUPnFGoP5gQLkWQDIsuBTGsShV4u4oj6IwxdTFJLGuHtZV_V26oG0jBGUsw7eCffg7S2D75XpkNNDVjqeg9zvFtqpkHanw6jgom5PjzAs5lxiBz37Yy8lhxKh6CMJm8s6e6WXZ7k4PDud96wzeO-rp6ScToqbA-jJSVtOPw9mf9r-ALtB2ny</recordid><startdate>202409</startdate><enddate>202409</enddate><creator>Hagen, Johannes M</creator><creator>Zacherl, Mathias J</creator><creator>Brendel, Matthias</creator><creator>Clauß, Sebastian</creator><creator>Kääb, Stefan</creator><creator>Bartenstein, Peter</creator><creator>Todica, Andrei</creator><creator>Böning, Guido</creator><creator>Fischer, Maximilian</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope></search><sort><creationdate>202409</creationdate><title>Quantitative assessment of cardiac 123 iodo-metaiodobenzylguanidine SPECT/CT in patients with arrhythmogenic right ventricular cardiomyopathy: Novel insight in disease monitoring</title><author>Hagen, Johannes M ; Zacherl, Mathias J ; Brendel, Matthias ; Clauß, Sebastian ; Kääb, Stefan ; Bartenstein, Peter ; Todica, Andrei ; Böning, Guido ; Fischer, Maximilian</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-pubmed_primary_390092153</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>3-Iodobenzylguanidine</topic><topic>Adult</topic><topic>Aged</topic><topic>Arrhythmogenic Right Ventricular Dysplasia - diagnostic imaging</topic><topic>Echocardiography - methods</topic><topic>Female</topic><topic>Heart - diagnostic imaging</topic><topic>Heart Ventricles - diagnostic imaging</topic><topic>Humans</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Radiopharmaceuticals</topic><topic>Single Photon Emission Computed Tomography Computed Tomography - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hagen, Johannes M</creatorcontrib><creatorcontrib>Zacherl, Mathias J</creatorcontrib><creatorcontrib>Brendel, Matthias</creatorcontrib><creatorcontrib>Clauß, Sebastian</creatorcontrib><creatorcontrib>Kääb, Stefan</creatorcontrib><creatorcontrib>Bartenstein, Peter</creatorcontrib><creatorcontrib>Todica, Andrei</creatorcontrib><creatorcontrib>Böning, Guido</creatorcontrib><creatorcontrib>Fischer, Maximilian</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><jtitle>Journal of nuclear cardiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hagen, Johannes M</au><au>Zacherl, Mathias J</au><au>Brendel, Matthias</au><au>Clauß, Sebastian</au><au>Kääb, Stefan</au><au>Bartenstein, Peter</au><au>Todica, Andrei</au><au>Böning, Guido</au><au>Fischer, Maximilian</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Quantitative assessment of cardiac 123 iodo-metaiodobenzylguanidine SPECT/CT in patients with arrhythmogenic right ventricular cardiomyopathy: Novel insight in disease monitoring</atitle><jtitle>Journal of nuclear cardiology</jtitle><addtitle>J Nucl Cardiol</addtitle><date>2024-09</date><risdate>2024</risdate><volume>39</volume><spage>101911</spage><pages>101911-</pages><eissn>1532-6551</eissn><abstract>The heart-to-mediastinum ratio (H/M-Ratio) of iodo-metaiodobenzylguanidine ( I-MIBG) represents state-of-the-art assessment for sympathetic dysfunction in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to evaluate quantitative reconstruction of I-MIBG uptake and to demonstrate its correlation with echocardiographic parameters. Cardiac innervation was assessed in 23 patients diagnosed with definite ARVC or borderline ARVC and 12 patients with other cardiac disease presenting arrhythmia, using quantitative I-MIBG Single Photon Emission Computed Tomography/Computed Tomography (SPECT/CT) imaging. Tracer uptake was evaluated in the left (LV) and right ventricle (RV) based on a CT scan after quantitative image reconstruction. The relationship between tracer uptake and echocardiographic parameter data was examined. Absolute quantification of I-MIBG uptake in the LV and RV is feasible and correlates accurately with the gold standard H/M Ratio. When comparing sensitivity and specificity, the area under the curve (AUC) favors standardized uptake value (SUV) of the RV over the right-ventricle-to-mediastinum-ratio (RV/M-Ratio) for diagnosing ARVC. A reduced RV-SUV in patients with definite ARVC is associated with reduced RV function. RV polar maps revealed globally reduced I-MIBG uptake without segment-specific reduction in the RV. Quantitative I-MIBG SPECT in ARCV patients offers robust potential for clinical reporting and demonstrates a significant correlation with RV function. Segmental RV analysis needs to be evaluated in larger samples. In summary, cardiac I-MIBG imaging using SUV could facilitate image-guided therapy in patients diagnosed with ARVC.</abstract><cop>United States</cop><pmid>39009215</pmid><doi>10.1016/j.nuclcard.2024.101911</doi></addata></record>
fulltext fulltext
identifier EISSN: 1532-6551
ispartof Journal of nuclear cardiology, 2024-09, Vol.39, p.101911
issn 1532-6551
language eng
recordid cdi_pubmed_primary_39009215
source MEDLINE; Alma/SFX Local Collection
subjects 3-Iodobenzylguanidine
Adult
Aged
Arrhythmogenic Right Ventricular Dysplasia - diagnostic imaging
Echocardiography - methods
Female
Heart - diagnostic imaging
Heart Ventricles - diagnostic imaging
Humans
Male
Middle Aged
Radiopharmaceuticals
Single Photon Emission Computed Tomography Computed Tomography - methods
title Quantitative assessment of cardiac 123 iodo-metaiodobenzylguanidine SPECT/CT in patients with arrhythmogenic right ventricular cardiomyopathy: Novel insight in disease monitoring
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T17%3A45%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Quantitative%20assessment%20of%20cardiac%20123%20iodo-metaiodobenzylguanidine%20SPECT/CT%20in%20patients%20with%20arrhythmogenic%20right%20ventricular%20cardiomyopathy:%20Novel%20insight%20in%20disease%20monitoring&rft.jtitle=Journal%20of%20nuclear%20cardiology&rft.au=Hagen,%20Johannes%20M&rft.date=2024-09&rft.volume=39&rft.spage=101911&rft.pages=101911-&rft.eissn=1532-6551&rft_id=info:doi/10.1016/j.nuclcard.2024.101911&rft_dat=%3Cpubmed%3E39009215%3C/pubmed%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/39009215&rfr_iscdi=true