Lithium inelastic cross-sections and their impact on micro and nano dosimetry of boron neutron capture

To present a new set of lithium-ion cross-sections for (i) ionization and excitation processes down to 700 eV, and (ii) charge-exchange processes down to 1 keV u . To evaluate the impact of the use of these cross-sections on micro a nano dosimetric quantities in the context of boron neutron capture...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physics in medicine & biology 2024-07, Vol.69 (14), p.145016
Hauptverfasser: D-Kondo, Naoki, Ortiz, Ramon, Faddegon, Bruce, Incerti, Sebastien, Tran, H N, Francis, Z, Moreno Barbosa, Eduardo, Schuemann, Jan, Ramos-Méndez, José
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 14
container_start_page 145016
container_title Physics in medicine & biology
container_volume 69
creator D-Kondo, Naoki
Ortiz, Ramon
Faddegon, Bruce
Incerti, Sebastien
Tran, H N
Francis, Z
Moreno Barbosa, Eduardo
Schuemann, Jan
Ramos-Méndez, José
description To present a new set of lithium-ion cross-sections for (i) ionization and excitation processes down to 700 eV, and (ii) charge-exchange processes down to 1 keV u . To evaluate the impact of the use of these cross-sections on micro a nano dosimetric quantities in the context of boron neutron capture (BNC) applications/techniques. The Classical Trajectory Monte Carlo method was used to calculate Li ion charge-exchange cross sections in the energy range of 1 keV u to 10 MeV u . Partial Li ion charge states ionization and excitation cross-sections were calculated using a detailed charge screening factor. The cross-sections were implemented in Geant4-DNA v10.07 and simulations and verified using TOPAS-nBio by calculating stopping power and continuous slowing down approximation (CSDA) range against data from ICRU and SRIM. Further microdosimetric and nanodosimetric calculations were performed to quantify differences against other simulation approaches for low energy Li ions. These calculations were: lineal energy spectra ( ( ) and ( )), frequency mean lineal energyyF-, dose mean lineal energyyD-and ionization cluster size distribution analysis. Microdosimetric calculations were compared against a previous MC study that neglected charge-exchange and excitation processes. Nanodosimetric results were compared against pure ionization scaled cross-sections calculations. Calculated stopping power differences between ICRU and Geant4-DNA decreased from 33.78% to 6.9%. The CSDA range difference decreased from 621% to 34% when compared against SRIM calculations. Geant4-DNA/TOPAS calculated dose mean lineal energy differed by 128% from the previous Monte Carlo. Ionization cluster size frequency distributions for Li ions differed by 76%-344.11% for 21 keV and 2 MeV respectively. With a decrease in the within 9% at 10 keV and agreeing after the 100 keV. With the new set of cross-sections being able to better simulate low energy behaviors of Li ions. This work shows an increase in detail gained from the use of a more complete set of low energy cross-sections which include charge exchange processes. Significant differences to previous simulation results were found at the microdosimetric and nanodosimetric scales that suggest that Li ions cause less ionizations per path length traveled but with more energy deposits. Microdosimetry results suggest that the BNC's contribution to cellular death may be mainly due to alpha particle production when boron-based drugs are distributed i
doi_str_mv 10.1088/1361-6560/ad5f72
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmed_primary_38964312</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3076017450</sourcerecordid><originalsourceid>FETCH-LOGICAL-c286t-706d9668d4ddd09ac91a07f0c5ba6860d761b6be745d24e0c2717390d15739963</originalsourceid><addsrcrecordid>eNp1kc1r3DAQxUVpaLZp7z0VHVuokxl_jO1jCG1TWOglOQtZklkFW3IluZD_PnI23V5aEDwY_eY9eMPYB4RLhK67woqwoIbgSupmbMtXbHcavWY7gAqLHpvmnL2N8QEAsSvrN-y86nqqKyx3bNzbdLDrzK0zk4zJKq6Cj7GIRiXrXeTSaZ4OxgZu50WqxL3js83Q84-TznPto51NCo_cj3zwIRPOrGlTJZe0BvOOnY1yiub9i16w-29f725ui_3P7z9urveFKjtKRQuke6JO11pr6KXqUUI7gmoGSR2BbgkHGkxbN7qsDaiyxbbqQWOTpafqgn0--h7kJJZgZxkehZdW3F7vxTaDmuoOS_qNmf10ZJfgf60mJjHbqMw0SWf8GkUFLQHmKMgoHNHnboIZT94IYruE2GoXW-3ieIm88vHFfR1mo08Lf6r_G2_9Ih78GlwuRizzIKgXWOfXAJJY9JjRL_9A_xv9BJOCnto</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3076017450</pqid></control><display><type>article</type><title>Lithium inelastic cross-sections and their impact on micro and nano dosimetry of boron neutron capture</title><source>MEDLINE</source><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>D-Kondo, Naoki ; Ortiz, Ramon ; Faddegon, Bruce ; Incerti, Sebastien ; Tran, H N ; Francis, Z ; Moreno Barbosa, Eduardo ; Schuemann, Jan ; Ramos-Méndez, José</creator><creatorcontrib>D-Kondo, Naoki ; Ortiz, Ramon ; Faddegon, Bruce ; Incerti, Sebastien ; Tran, H N ; Francis, Z ; Moreno Barbosa, Eduardo ; Schuemann, Jan ; Ramos-Méndez, José</creatorcontrib><description>To present a new set of lithium-ion cross-sections for (i) ionization and excitation processes down to 700 eV, and (ii) charge-exchange processes down to 1 keV u . To evaluate the impact of the use of these cross-sections on micro a nano dosimetric quantities in the context of boron neutron capture (BNC) applications/techniques. The Classical Trajectory Monte Carlo method was used to calculate Li ion charge-exchange cross sections in the energy range of 1 keV u to 10 MeV u . Partial Li ion charge states ionization and excitation cross-sections were calculated using a detailed charge screening factor. The cross-sections were implemented in Geant4-DNA v10.07 and simulations and verified using TOPAS-nBio by calculating stopping power and continuous slowing down approximation (CSDA) range against data from ICRU and SRIM. Further microdosimetric and nanodosimetric calculations were performed to quantify differences against other simulation approaches for low energy Li ions. These calculations were: lineal energy spectra ( ( ) and ( )), frequency mean lineal energyyF-, dose mean lineal energyyD-and ionization cluster size distribution analysis. Microdosimetric calculations were compared against a previous MC study that neglected charge-exchange and excitation processes. Nanodosimetric results were compared against pure ionization scaled cross-sections calculations. Calculated stopping power differences between ICRU and Geant4-DNA decreased from 33.78% to 6.9%. The CSDA range difference decreased from 621% to 34% when compared against SRIM calculations. Geant4-DNA/TOPAS calculated dose mean lineal energy differed by 128% from the previous Monte Carlo. Ionization cluster size frequency distributions for Li ions differed by 76%-344.11% for 21 keV and 2 MeV respectively. With a decrease in the within 9% at 10 keV and agreeing after the 100 keV. With the new set of cross-sections being able to better simulate low energy behaviors of Li ions. This work shows an increase in detail gained from the use of a more complete set of low energy cross-sections which include charge exchange processes. Significant differences to previous simulation results were found at the microdosimetric and nanodosimetric scales that suggest that Li ions cause less ionizations per path length traveled but with more energy deposits. Microdosimetry results suggest that the BNC's contribution to cellular death may be mainly due to alpha particle production when boron-based drugs are distributed in the cellular membrane and beyond and by Li when it is at the cell cytoplasm regions.</description><identifier>ISSN: 0031-9155</identifier><identifier>ISSN: 1361-6560</identifier><identifier>EISSN: 1361-6560</identifier><identifier>DOI: 10.1088/1361-6560/ad5f72</identifier><identifier>PMID: 38964312</identifier><identifier>CODEN: PHMBA7</identifier><language>eng</language><publisher>England: IOP Publishing</publisher><subject>Bioengineering ; BNCT ; Boron Neutron Capture Therapy - methods ; Elasticity ; ionization detail ; Life Sciences ; Lithium - chemistry ; lithium ions ; low energy ; Medical Physics ; Monte Carlo Method ; Monte Carlo track structure ; Nanotechnology ; Nuclear medicine ; Physics ; Radiometry</subject><ispartof>Physics in medicine &amp; biology, 2024-07, Vol.69 (14), p.145016</ispartof><rights>2024 Institute of Physics and Engineering in Medicine</rights><rights>2024 Institute of Physics and Engineering in Medicine.</rights><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c286t-706d9668d4ddd09ac91a07f0c5ba6860d761b6be745d24e0c2717390d15739963</cites><orcidid>0000-0002-1114-2640 ; 0000-0002-8106-5142 ; 0000-0002-4410-1925 ; 0000-0002-0619-2053 ; 0000-0002-7554-8818 ; 0000-0002-4573-1582 ; 0000-0002-4628-8121</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/1361-6560/ad5f72/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>230,314,776,780,881,27901,27902,53821,53868</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38964312$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://hal.science/hal-04648126$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>D-Kondo, Naoki</creatorcontrib><creatorcontrib>Ortiz, Ramon</creatorcontrib><creatorcontrib>Faddegon, Bruce</creatorcontrib><creatorcontrib>Incerti, Sebastien</creatorcontrib><creatorcontrib>Tran, H N</creatorcontrib><creatorcontrib>Francis, Z</creatorcontrib><creatorcontrib>Moreno Barbosa, Eduardo</creatorcontrib><creatorcontrib>Schuemann, Jan</creatorcontrib><creatorcontrib>Ramos-Méndez, José</creatorcontrib><title>Lithium inelastic cross-sections and their impact on micro and nano dosimetry of boron neutron capture</title><title>Physics in medicine &amp; biology</title><addtitle>PMB</addtitle><addtitle>Phys. Med. Biol</addtitle><description>To present a new set of lithium-ion cross-sections for (i) ionization and excitation processes down to 700 eV, and (ii) charge-exchange processes down to 1 keV u . To evaluate the impact of the use of these cross-sections on micro a nano dosimetric quantities in the context of boron neutron capture (BNC) applications/techniques. The Classical Trajectory Monte Carlo method was used to calculate Li ion charge-exchange cross sections in the energy range of 1 keV u to 10 MeV u . Partial Li ion charge states ionization and excitation cross-sections were calculated using a detailed charge screening factor. The cross-sections were implemented in Geant4-DNA v10.07 and simulations and verified using TOPAS-nBio by calculating stopping power and continuous slowing down approximation (CSDA) range against data from ICRU and SRIM. Further microdosimetric and nanodosimetric calculations were performed to quantify differences against other simulation approaches for low energy Li ions. These calculations were: lineal energy spectra ( ( ) and ( )), frequency mean lineal energyyF-, dose mean lineal energyyD-and ionization cluster size distribution analysis. Microdosimetric calculations were compared against a previous MC study that neglected charge-exchange and excitation processes. Nanodosimetric results were compared against pure ionization scaled cross-sections calculations. Calculated stopping power differences between ICRU and Geant4-DNA decreased from 33.78% to 6.9%. The CSDA range difference decreased from 621% to 34% when compared against SRIM calculations. Geant4-DNA/TOPAS calculated dose mean lineal energy differed by 128% from the previous Monte Carlo. Ionization cluster size frequency distributions for Li ions differed by 76%-344.11% for 21 keV and 2 MeV respectively. With a decrease in the within 9% at 10 keV and agreeing after the 100 keV. With the new set of cross-sections being able to better simulate low energy behaviors of Li ions. This work shows an increase in detail gained from the use of a more complete set of low energy cross-sections which include charge exchange processes. Significant differences to previous simulation results were found at the microdosimetric and nanodosimetric scales that suggest that Li ions cause less ionizations per path length traveled but with more energy deposits. Microdosimetry results suggest that the BNC's contribution to cellular death may be mainly due to alpha particle production when boron-based drugs are distributed in the cellular membrane and beyond and by Li when it is at the cell cytoplasm regions.</description><subject>Bioengineering</subject><subject>BNCT</subject><subject>Boron Neutron Capture Therapy - methods</subject><subject>Elasticity</subject><subject>ionization detail</subject><subject>Life Sciences</subject><subject>Lithium - chemistry</subject><subject>lithium ions</subject><subject>low energy</subject><subject>Medical Physics</subject><subject>Monte Carlo Method</subject><subject>Monte Carlo track structure</subject><subject>Nanotechnology</subject><subject>Nuclear medicine</subject><subject>Physics</subject><subject>Radiometry</subject><issn>0031-9155</issn><issn>1361-6560</issn><issn>1361-6560</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kc1r3DAQxUVpaLZp7z0VHVuokxl_jO1jCG1TWOglOQtZklkFW3IluZD_PnI23V5aEDwY_eY9eMPYB4RLhK67woqwoIbgSupmbMtXbHcavWY7gAqLHpvmnL2N8QEAsSvrN-y86nqqKyx3bNzbdLDrzK0zk4zJKq6Cj7GIRiXrXeTSaZ4OxgZu50WqxL3js83Q84-TznPto51NCo_cj3zwIRPOrGlTJZe0BvOOnY1yiub9i16w-29f725ui_3P7z9urveFKjtKRQuke6JO11pr6KXqUUI7gmoGSR2BbgkHGkxbN7qsDaiyxbbqQWOTpafqgn0--h7kJJZgZxkehZdW3F7vxTaDmuoOS_qNmf10ZJfgf60mJjHbqMw0SWf8GkUFLQHmKMgoHNHnboIZT94IYruE2GoXW-3ieIm88vHFfR1mo08Lf6r_G2_9Ih78GlwuRizzIKgXWOfXAJJY9JjRL_9A_xv9BJOCnto</recordid><startdate>20240715</startdate><enddate>20240715</enddate><creator>D-Kondo, Naoki</creator><creator>Ortiz, Ramon</creator><creator>Faddegon, Bruce</creator><creator>Incerti, Sebastien</creator><creator>Tran, H N</creator><creator>Francis, Z</creator><creator>Moreno Barbosa, Eduardo</creator><creator>Schuemann, Jan</creator><creator>Ramos-Méndez, José</creator><general>IOP Publishing</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>1XC</scope><scope>VOOES</scope><orcidid>https://orcid.org/0000-0002-1114-2640</orcidid><orcidid>https://orcid.org/0000-0002-8106-5142</orcidid><orcidid>https://orcid.org/0000-0002-4410-1925</orcidid><orcidid>https://orcid.org/0000-0002-0619-2053</orcidid><orcidid>https://orcid.org/0000-0002-7554-8818</orcidid><orcidid>https://orcid.org/0000-0002-4573-1582</orcidid><orcidid>https://orcid.org/0000-0002-4628-8121</orcidid></search><sort><creationdate>20240715</creationdate><title>Lithium inelastic cross-sections and their impact on micro and nano dosimetry of boron neutron capture</title><author>D-Kondo, Naoki ; Ortiz, Ramon ; Faddegon, Bruce ; Incerti, Sebastien ; Tran, H N ; Francis, Z ; Moreno Barbosa, Eduardo ; Schuemann, Jan ; Ramos-Méndez, José</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c286t-706d9668d4ddd09ac91a07f0c5ba6860d761b6be745d24e0c2717390d15739963</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Bioengineering</topic><topic>BNCT</topic><topic>Boron Neutron Capture Therapy - methods</topic><topic>Elasticity</topic><topic>ionization detail</topic><topic>Life Sciences</topic><topic>Lithium - chemistry</topic><topic>lithium ions</topic><topic>low energy</topic><topic>Medical Physics</topic><topic>Monte Carlo Method</topic><topic>Monte Carlo track structure</topic><topic>Nanotechnology</topic><topic>Nuclear medicine</topic><topic>Physics</topic><topic>Radiometry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>D-Kondo, Naoki</creatorcontrib><creatorcontrib>Ortiz, Ramon</creatorcontrib><creatorcontrib>Faddegon, Bruce</creatorcontrib><creatorcontrib>Incerti, Sebastien</creatorcontrib><creatorcontrib>Tran, H N</creatorcontrib><creatorcontrib>Francis, Z</creatorcontrib><creatorcontrib>Moreno Barbosa, Eduardo</creatorcontrib><creatorcontrib>Schuemann, Jan</creatorcontrib><creatorcontrib>Ramos-Méndez, José</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Hyper Article en Ligne (HAL)</collection><collection>Hyper Article en Ligne (HAL) (Open Access)</collection><jtitle>Physics in medicine &amp; biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>D-Kondo, Naoki</au><au>Ortiz, Ramon</au><au>Faddegon, Bruce</au><au>Incerti, Sebastien</au><au>Tran, H N</au><au>Francis, Z</au><au>Moreno Barbosa, Eduardo</au><au>Schuemann, Jan</au><au>Ramos-Méndez, José</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Lithium inelastic cross-sections and their impact on micro and nano dosimetry of boron neutron capture</atitle><jtitle>Physics in medicine &amp; biology</jtitle><stitle>PMB</stitle><addtitle>Phys. Med. Biol</addtitle><date>2024-07-15</date><risdate>2024</risdate><volume>69</volume><issue>14</issue><spage>145016</spage><pages>145016-</pages><issn>0031-9155</issn><issn>1361-6560</issn><eissn>1361-6560</eissn><coden>PHMBA7</coden><abstract>To present a new set of lithium-ion cross-sections for (i) ionization and excitation processes down to 700 eV, and (ii) charge-exchange processes down to 1 keV u . To evaluate the impact of the use of these cross-sections on micro a nano dosimetric quantities in the context of boron neutron capture (BNC) applications/techniques. The Classical Trajectory Monte Carlo method was used to calculate Li ion charge-exchange cross sections in the energy range of 1 keV u to 10 MeV u . Partial Li ion charge states ionization and excitation cross-sections were calculated using a detailed charge screening factor. The cross-sections were implemented in Geant4-DNA v10.07 and simulations and verified using TOPAS-nBio by calculating stopping power and continuous slowing down approximation (CSDA) range against data from ICRU and SRIM. Further microdosimetric and nanodosimetric calculations were performed to quantify differences against other simulation approaches for low energy Li ions. These calculations were: lineal energy spectra ( ( ) and ( )), frequency mean lineal energyyF-, dose mean lineal energyyD-and ionization cluster size distribution analysis. Microdosimetric calculations were compared against a previous MC study that neglected charge-exchange and excitation processes. Nanodosimetric results were compared against pure ionization scaled cross-sections calculations. Calculated stopping power differences between ICRU and Geant4-DNA decreased from 33.78% to 6.9%. The CSDA range difference decreased from 621% to 34% when compared against SRIM calculations. Geant4-DNA/TOPAS calculated dose mean lineal energy differed by 128% from the previous Monte Carlo. Ionization cluster size frequency distributions for Li ions differed by 76%-344.11% for 21 keV and 2 MeV respectively. With a decrease in the within 9% at 10 keV and agreeing after the 100 keV. With the new set of cross-sections being able to better simulate low energy behaviors of Li ions. This work shows an increase in detail gained from the use of a more complete set of low energy cross-sections which include charge exchange processes. Significant differences to previous simulation results were found at the microdosimetric and nanodosimetric scales that suggest that Li ions cause less ionizations per path length traveled but with more energy deposits. Microdosimetry results suggest that the BNC's contribution to cellular death may be mainly due to alpha particle production when boron-based drugs are distributed in the cellular membrane and beyond and by Li when it is at the cell cytoplasm regions.</abstract><cop>England</cop><pub>IOP Publishing</pub><pmid>38964312</pmid><doi>10.1088/1361-6560/ad5f72</doi><tpages>16</tpages><orcidid>https://orcid.org/0000-0002-1114-2640</orcidid><orcidid>https://orcid.org/0000-0002-8106-5142</orcidid><orcidid>https://orcid.org/0000-0002-4410-1925</orcidid><orcidid>https://orcid.org/0000-0002-0619-2053</orcidid><orcidid>https://orcid.org/0000-0002-7554-8818</orcidid><orcidid>https://orcid.org/0000-0002-4573-1582</orcidid><orcidid>https://orcid.org/0000-0002-4628-8121</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0031-9155
ispartof Physics in medicine & biology, 2024-07, Vol.69 (14), p.145016
issn 0031-9155
1361-6560
1361-6560
language eng
recordid cdi_pubmed_primary_38964312
source MEDLINE; IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
subjects Bioengineering
BNCT
Boron Neutron Capture Therapy - methods
Elasticity
ionization detail
Life Sciences
Lithium - chemistry
lithium ions
low energy
Medical Physics
Monte Carlo Method
Monte Carlo track structure
Nanotechnology
Nuclear medicine
Physics
Radiometry
title Lithium inelastic cross-sections and their impact on micro and nano dosimetry of boron neutron capture
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T06%3A53%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Lithium%20inelastic%20cross-sections%20and%20their%20impact%20on%20micro%20and%20nano%20dosimetry%20of%20boron%20neutron%20capture&rft.jtitle=Physics%20in%20medicine%20&%20biology&rft.au=D-Kondo,%20Naoki&rft.date=2024-07-15&rft.volume=69&rft.issue=14&rft.spage=145016&rft.pages=145016-&rft.issn=0031-9155&rft.eissn=1361-6560&rft.coden=PHMBA7&rft_id=info:doi/10.1088/1361-6560/ad5f72&rft_dat=%3Cproquest_pubme%3E3076017450%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3076017450&rft_id=info:pmid/38964312&rfr_iscdi=true