Free and bound sodium identification by skin dielectric properties separation algorithm of bioelectrical impedance spectroscopy (spa-BIS) in human skin model

Free and bound sodium in human skin models have been identified by two proposals: skin's phantom fabrication and skin's dielectric properties separation algorithm of bioelectrical impedance spectroscopy ( -BIS). The -BIS consist of conductivity-permittivity separation, contact impedance co...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biomedical physics & engineering express 2023-09, Vol.9 (5), p.55010
Hauptverfasser: Ibrahim, Kiagus A, Wicaksono, Ridwan, Baidillah, Marlin R, Ito, Koichi, Takei, Masahiro
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Free and bound sodium in human skin models have been identified by two proposals: skin's phantom fabrication and skin's dielectric properties separation algorithm of bioelectrical impedance spectroscopy ( -BIS). The -BIS consist of conductivity-permittivity separation, contact impedance compensation, and a correlation score algorithm based on the vessel with a bipolar electrode. The skin phantom fabrication comprises a recipe combination with temperature-controlled protocol and sodium molarity calculation. In experiments, the human skin models are created to mimic the electrical properties of skin under1MHzwith several different sodium molarities. Based on five types of human skin models with five samples of each group, the free sodium type conductivity and concentration resultsR2=0.9903-following a linear trendline of concentration change in skin tissues theorems with the fRequency range from1kHzto1MHz,while the bound sodium type resultsR2=0.9061-.The -BIS compensate7-16Ωof vessel contact impedance. The dielectric properties of each type have been extracted with less than 10% of the average standard deviation, which is considered an accurate identification method of dermis dielectric properties. The algorithm successfully identifies sodium type: free sodium has a negative, and bound sodium has a positive correlation score trend. As an additional discussion, the different time-dependent effects, the different water content, and different agar content analyses have been provided in this study. As a robust analysis method, the -BIS has a prominent performance to replace a Na-MRI in terms of free and bound sodium identification.
ISSN:2057-1976
2057-1976
DOI:10.1088/2057-1976/ace7d8