Effect of valve spacing on peristaltic pumping

Peristaltic fluid pumping due to a periodically propagating contraction wave in a vessel fitted with one-way elastic valves is investigated numerically. It is concluded that the valve spacing within the vessel relative to the contraction wavelength plays a critical role in providing efficient pumpin...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Bioinspiration & biomimetics 2023-03, Vol.18 (3), p.35002
Hauptverfasser: Wolf, Ki Tae, Poorghani, Amir, Dixon, J Brandon, Alexeev, Alexander
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 3
container_start_page 35002
container_title Bioinspiration & biomimetics
container_volume 18
creator Wolf, Ki Tae
Poorghani, Amir
Dixon, J Brandon
Alexeev, Alexander
description Peristaltic fluid pumping due to a periodically propagating contraction wave in a vessel fitted with one-way elastic valves is investigated numerically. It is concluded that the valve spacing within the vessel relative to the contraction wavelength plays a critical role in providing efficient pumping. When the valve spacing does not match the wavelength, the valves open asynchronously and the volume of the vessel segments bounded by two consecutive valves changes periodically, thereby inducing volumetric fluid pumping. The volumetric pumping leads to higher pumping flowrate and efficiency against an adverse pressure gradient. The optimum pumping occurs when the ratio of valve spacing to contraction wavelength is about2/3. This pumping regime is characterized by a longer period during which the valves are open. The results are useful for further understanding the pumping features of lymphatic system and provide insight into the design of biomimetic pumping devices.
doi_str_mv 10.1088/1748-3190/acbe85
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmed_primary_36821859</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2780065622</sourcerecordid><originalsourceid>FETCH-LOGICAL-c433t-267b43f5abf61453bd4b86f261a6470dac626d53fa48a1e79d2ffb581bfbe95f3</originalsourceid><addsrcrecordid>eNp1kL1PwzAQxS0EoqWwM6GMDKT1R-w4CxKqyodUiQVmy3bs4iqNg51U4r8nVUoEA9Od7t57d_oBcI3gHEHOFyjPeEpQARdSK8PpCZiOo9Ox53gCLmLcQkizguNzMCGMY8RpMQXzlbVGt4m3yV5We5PERmpXbxJfJ40JLrayap1Omm7X9ONLcGZlFc3Vsc7A--Pqbfmcrl-fXpYP61RnhLQpZrnKiKVSWYYySlSZKc4sZkiyLIel1AyzkhIrMy6RyYsSW6soR8oqU1BLZuB-yG06tTOlNnUbZCWa4HYyfAkvnfi7qd2H2Pi9KIoihyzvA26PAcF_dia2YueiNlUla-O7KHDOIWSUYdxL4SDVwccYjB3PICgOmMWBozgwFQPm3nLz-73R8MO1F9wNAucbsfVdqHta_-d9A7Brh98</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2780065622</pqid></control><display><type>article</type><title>Effect of valve spacing on peristaltic pumping</title><source>Institute of Physics Journals</source><source>MEDLINE</source><creator>Wolf, Ki Tae ; Poorghani, Amir ; Dixon, J Brandon ; Alexeev, Alexander</creator><creatorcontrib>Wolf, Ki Tae ; Poorghani, Amir ; Dixon, J Brandon ; Alexeev, Alexander</creatorcontrib><description>Peristaltic fluid pumping due to a periodically propagating contraction wave in a vessel fitted with one-way elastic valves is investigated numerically. It is concluded that the valve spacing within the vessel relative to the contraction wavelength plays a critical role in providing efficient pumping. When the valve spacing does not match the wavelength, the valves open asynchronously and the volume of the vessel segments bounded by two consecutive valves changes periodically, thereby inducing volumetric fluid pumping. The volumetric pumping leads to higher pumping flowrate and efficiency against an adverse pressure gradient. The optimum pumping occurs when the ratio of valve spacing to contraction wavelength is about2/3. This pumping regime is characterized by a longer period during which the valves are open. The results are useful for further understanding the pumping features of lymphatic system and provide insight into the design of biomimetic pumping devices.</description><identifier>ISSN: 1748-3182</identifier><identifier>EISSN: 1748-3190</identifier><identifier>DOI: 10.1088/1748-3190/acbe85</identifier><identifier>PMID: 36821859</identifier><identifier>CODEN: BBIICI</identifier><language>eng</language><publisher>England: IOP Publishing</publisher><subject>elastic valves ; flow-vessel interaction ; Models, Biological ; Peristalsis ; peristaltic micro pumping ; valve spacing</subject><ispartof>Bioinspiration &amp; biomimetics, 2023-03, Vol.18 (3), p.35002</ispartof><rights>2023 The Author(s). Published by IOP Publishing Ltd</rights><rights>Creative Commons Attribution license.</rights><rights>2023 The Author(s). Published by IOP Publishing Ltd 2023</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c433t-267b43f5abf61453bd4b86f261a6470dac626d53fa48a1e79d2ffb581bfbe95f3</citedby><cites>FETCH-LOGICAL-c433t-267b43f5abf61453bd4b86f261a6470dac626d53fa48a1e79d2ffb581bfbe95f3</cites><orcidid>0000-0002-8285-0003</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/1748-3190/acbe85/pdf$$EPDF$$P50$$Giop$$Hfree_for_read</linktopdf><link.rule.ids>230,314,780,784,885,27924,27925,53846,53893</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36821859$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Wolf, Ki Tae</creatorcontrib><creatorcontrib>Poorghani, Amir</creatorcontrib><creatorcontrib>Dixon, J Brandon</creatorcontrib><creatorcontrib>Alexeev, Alexander</creatorcontrib><title>Effect of valve spacing on peristaltic pumping</title><title>Bioinspiration &amp; biomimetics</title><addtitle>BB</addtitle><addtitle>Bioinspir. Biomim</addtitle><description>Peristaltic fluid pumping due to a periodically propagating contraction wave in a vessel fitted with one-way elastic valves is investigated numerically. It is concluded that the valve spacing within the vessel relative to the contraction wavelength plays a critical role in providing efficient pumping. When the valve spacing does not match the wavelength, the valves open asynchronously and the volume of the vessel segments bounded by two consecutive valves changes periodically, thereby inducing volumetric fluid pumping. The volumetric pumping leads to higher pumping flowrate and efficiency against an adverse pressure gradient. The optimum pumping occurs when the ratio of valve spacing to contraction wavelength is about2/3. This pumping regime is characterized by a longer period during which the valves are open. The results are useful for further understanding the pumping features of lymphatic system and provide insight into the design of biomimetic pumping devices.</description><subject>elastic valves</subject><subject>flow-vessel interaction</subject><subject>Models, Biological</subject><subject>Peristalsis</subject><subject>peristaltic micro pumping</subject><subject>valve spacing</subject><issn>1748-3182</issn><issn>1748-3190</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>O3W</sourceid><sourceid>EIF</sourceid><recordid>eNp1kL1PwzAQxS0EoqWwM6GMDKT1R-w4CxKqyodUiQVmy3bs4iqNg51U4r8nVUoEA9Od7t57d_oBcI3gHEHOFyjPeEpQARdSK8PpCZiOo9Ox53gCLmLcQkizguNzMCGMY8RpMQXzlbVGt4m3yV5We5PERmpXbxJfJ40JLrayap1Omm7X9ONLcGZlFc3Vsc7A--Pqbfmcrl-fXpYP61RnhLQpZrnKiKVSWYYySlSZKc4sZkiyLIel1AyzkhIrMy6RyYsSW6soR8oqU1BLZuB-yG06tTOlNnUbZCWa4HYyfAkvnfi7qd2H2Pi9KIoihyzvA26PAcF_dia2YueiNlUla-O7KHDOIWSUYdxL4SDVwccYjB3PICgOmMWBozgwFQPm3nLz-73R8MO1F9wNAucbsfVdqHta_-d9A7Brh98</recordid><startdate>20230309</startdate><enddate>20230309</enddate><creator>Wolf, Ki Tae</creator><creator>Poorghani, Amir</creator><creator>Dixon, J Brandon</creator><creator>Alexeev, Alexander</creator><general>IOP Publishing</general><scope>O3W</scope><scope>TSCCA</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0002-8285-0003</orcidid></search><sort><creationdate>20230309</creationdate><title>Effect of valve spacing on peristaltic pumping</title><author>Wolf, Ki Tae ; Poorghani, Amir ; Dixon, J Brandon ; Alexeev, Alexander</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c433t-267b43f5abf61453bd4b86f261a6470dac626d53fa48a1e79d2ffb581bfbe95f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>elastic valves</topic><topic>flow-vessel interaction</topic><topic>Models, Biological</topic><topic>Peristalsis</topic><topic>peristaltic micro pumping</topic><topic>valve spacing</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wolf, Ki Tae</creatorcontrib><creatorcontrib>Poorghani, Amir</creatorcontrib><creatorcontrib>Dixon, J Brandon</creatorcontrib><creatorcontrib>Alexeev, Alexander</creatorcontrib><collection>Institute of Physics Open Access Journal Titles</collection><collection>IOPscience (Open Access)</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Bioinspiration &amp; biomimetics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wolf, Ki Tae</au><au>Poorghani, Amir</au><au>Dixon, J Brandon</au><au>Alexeev, Alexander</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of valve spacing on peristaltic pumping</atitle><jtitle>Bioinspiration &amp; biomimetics</jtitle><stitle>BB</stitle><addtitle>Bioinspir. Biomim</addtitle><date>2023-03-09</date><risdate>2023</risdate><volume>18</volume><issue>3</issue><spage>35002</spage><pages>35002-</pages><issn>1748-3182</issn><eissn>1748-3190</eissn><coden>BBIICI</coden><abstract>Peristaltic fluid pumping due to a periodically propagating contraction wave in a vessel fitted with one-way elastic valves is investigated numerically. It is concluded that the valve spacing within the vessel relative to the contraction wavelength plays a critical role in providing efficient pumping. When the valve spacing does not match the wavelength, the valves open asynchronously and the volume of the vessel segments bounded by two consecutive valves changes periodically, thereby inducing volumetric fluid pumping. The volumetric pumping leads to higher pumping flowrate and efficiency against an adverse pressure gradient. The optimum pumping occurs when the ratio of valve spacing to contraction wavelength is about2/3. This pumping regime is characterized by a longer period during which the valves are open. The results are useful for further understanding the pumping features of lymphatic system and provide insight into the design of biomimetic pumping devices.</abstract><cop>England</cop><pub>IOP Publishing</pub><pmid>36821859</pmid><doi>10.1088/1748-3190/acbe85</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0002-8285-0003</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1748-3182
ispartof Bioinspiration & biomimetics, 2023-03, Vol.18 (3), p.35002
issn 1748-3182
1748-3190
language eng
recordid cdi_pubmed_primary_36821859
source Institute of Physics Journals; MEDLINE
subjects elastic valves
flow-vessel interaction
Models, Biological
Peristalsis
peristaltic micro pumping
valve spacing
title Effect of valve spacing on peristaltic pumping
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T10%3A06%3A04IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20valve%20spacing%20on%20peristaltic%20pumping&rft.jtitle=Bioinspiration%20&%20biomimetics&rft.au=Wolf,%20Ki%20Tae&rft.date=2023-03-09&rft.volume=18&rft.issue=3&rft.spage=35002&rft.pages=35002-&rft.issn=1748-3182&rft.eissn=1748-3190&rft.coden=BBIICI&rft_id=info:doi/10.1088/1748-3190/acbe85&rft_dat=%3Cproquest_pubme%3E2780065622%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2780065622&rft_id=info:pmid/36821859&rfr_iscdi=true