Pressure/colorimetric dual-readout immunochromatographic test strip for point-of-care testing of aflatoxin B 1

Immunochromatographic test strip (ITS) for point-of-care testing (POCT) has attracted prominent attention due to the advantages including rapid response, low cost and good portability. Here, we developed a sensitive ITS for detecting aflatoxin B (AFB ) by using dendritic platinum nanoparticles (DPNs...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2021-05, Vol.227, p.122203
Hauptverfasser: Jiang, Shan, Zhang, Lvxia, Li, Jizhou, Ouyang, Hui, Fu, Zhifeng
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page 122203
container_title Talanta (Oxford)
container_volume 227
creator Jiang, Shan
Zhang, Lvxia
Li, Jizhou
Ouyang, Hui
Fu, Zhifeng
description Immunochromatographic test strip (ITS) for point-of-care testing (POCT) has attracted prominent attention due to the advantages including rapid response, low cost and good portability. Here, we developed a sensitive ITS for detecting aflatoxin B (AFB ) by using dendritic platinum nanoparticles (DPNs) as novel pressure/colorimetric dual-readout probes. DPNs-labeled antibody of AFB were used as the signal tracer of the immunochromatographic process. After 10-min competitive immunoreaction, black color appeared on the test line of ITS due to the accumulation of DPNs, which was observed visually as a colorimetric readout for qualitation purpose. Furthermore, DPNs with peroxidase-like activity caused decomposition of hydrogen peroxide aqueous solution to produce pressure change signal in vials, which was detected by a hand-held pressure meter for quantitation purpose. With the pressure readout mode, the detection range was 0.05-10 ng mL , and the detection limit was 0.03 ng mL  (S/N = 3) for AFB . The proposed ITS was successfully utilized for detecting AFB in herbal medicine samples, and the acceptable recoveries of 93.77-114.09% indicated the reliability for real sample detection. It provides a new avenue for POCT with great application potential in various area including drug and food quality control, pollutants monitoring as well as medical diagnosis.
doi_str_mv 10.1016/j.talanta.2021.122203
format Article
fullrecord <record><control><sourceid>pubmed</sourceid><recordid>TN_cdi_pubmed_primary_33714473</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>33714473</sourcerecordid><originalsourceid>FETCH-LOGICAL-p108t-3cbfd9884251b60cc0cb11657a75c0b5b57e9e8671998905a005824136df92a43</originalsourceid><addsrcrecordid>eNo1j8tOwzAURC0kREvhE0D-AafXdhw7S6h4SZVgAevqxrHbVEkc2Y4Ef0_FYzWLOTPSIeSGQ8GBV-tjkbHHMWMhQPCCCyFAnpElN1oyqbRckMuUjgAgJMgLspBS87LUcknGt-hSmqNb29CH2A0ux87SdsaeRYdtmDPthmEegz3EMGAO-4jT4YRklzJNJ3qiPkQ6hW7MLHhmMbqfshv3NHiKvj-tPruR3lN-Rc499sld_-WKfDw-vG-e2fb16WVzt2UTB5OZtI1va2NKoXhTgbVgG84rpVErC41qlHa1M5XmdW1qUAigjCi5rFpfCyzlitz-_k5zM7h2N53MMH7t_sXlNxPwXJA</addsrcrecordid><sourcetype>Index Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Pressure/colorimetric dual-readout immunochromatographic test strip for point-of-care testing of aflatoxin B 1</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><creator>Jiang, Shan ; Zhang, Lvxia ; Li, Jizhou ; Ouyang, Hui ; Fu, Zhifeng</creator><creatorcontrib>Jiang, Shan ; Zhang, Lvxia ; Li, Jizhou ; Ouyang, Hui ; Fu, Zhifeng</creatorcontrib><description>Immunochromatographic test strip (ITS) for point-of-care testing (POCT) has attracted prominent attention due to the advantages including rapid response, low cost and good portability. Here, we developed a sensitive ITS for detecting aflatoxin B (AFB ) by using dendritic platinum nanoparticles (DPNs) as novel pressure/colorimetric dual-readout probes. DPNs-labeled antibody of AFB were used as the signal tracer of the immunochromatographic process. After 10-min competitive immunoreaction, black color appeared on the test line of ITS due to the accumulation of DPNs, which was observed visually as a colorimetric readout for qualitation purpose. Furthermore, DPNs with peroxidase-like activity caused decomposition of hydrogen peroxide aqueous solution to produce pressure change signal in vials, which was detected by a hand-held pressure meter for quantitation purpose. With the pressure readout mode, the detection range was 0.05-10 ng mL , and the detection limit was 0.03 ng mL  (S/N = 3) for AFB . The proposed ITS was successfully utilized for detecting AFB in herbal medicine samples, and the acceptable recoveries of 93.77-114.09% indicated the reliability for real sample detection. It provides a new avenue for POCT with great application potential in various area including drug and food quality control, pollutants monitoring as well as medical diagnosis.</description><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/j.talanta.2021.122203</identifier><identifier>PMID: 33714473</identifier><language>eng</language><publisher>Netherlands</publisher><subject>Aflatoxin B1 - analysis ; Colorimetry ; Limit of Detection ; Metal Nanoparticles ; Platinum ; Point-of-Care Testing ; Reproducibility of Results</subject><ispartof>Talanta (Oxford), 2021-05, Vol.227, p.122203</ispartof><rights>Copyright © 2021 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33714473$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Jiang, Shan</creatorcontrib><creatorcontrib>Zhang, Lvxia</creatorcontrib><creatorcontrib>Li, Jizhou</creatorcontrib><creatorcontrib>Ouyang, Hui</creatorcontrib><creatorcontrib>Fu, Zhifeng</creatorcontrib><title>Pressure/colorimetric dual-readout immunochromatographic test strip for point-of-care testing of aflatoxin B 1</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>Immunochromatographic test strip (ITS) for point-of-care testing (POCT) has attracted prominent attention due to the advantages including rapid response, low cost and good portability. Here, we developed a sensitive ITS for detecting aflatoxin B (AFB ) by using dendritic platinum nanoparticles (DPNs) as novel pressure/colorimetric dual-readout probes. DPNs-labeled antibody of AFB were used as the signal tracer of the immunochromatographic process. After 10-min competitive immunoreaction, black color appeared on the test line of ITS due to the accumulation of DPNs, which was observed visually as a colorimetric readout for qualitation purpose. Furthermore, DPNs with peroxidase-like activity caused decomposition of hydrogen peroxide aqueous solution to produce pressure change signal in vials, which was detected by a hand-held pressure meter for quantitation purpose. With the pressure readout mode, the detection range was 0.05-10 ng mL , and the detection limit was 0.03 ng mL  (S/N = 3) for AFB . The proposed ITS was successfully utilized for detecting AFB in herbal medicine samples, and the acceptable recoveries of 93.77-114.09% indicated the reliability for real sample detection. It provides a new avenue for POCT with great application potential in various area including drug and food quality control, pollutants monitoring as well as medical diagnosis.</description><subject>Aflatoxin B1 - analysis</subject><subject>Colorimetry</subject><subject>Limit of Detection</subject><subject>Metal Nanoparticles</subject><subject>Platinum</subject><subject>Point-of-Care Testing</subject><subject>Reproducibility of Results</subject><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo1j8tOwzAURC0kREvhE0D-AafXdhw7S6h4SZVgAevqxrHbVEkc2Y4Ef0_FYzWLOTPSIeSGQ8GBV-tjkbHHMWMhQPCCCyFAnpElN1oyqbRckMuUjgAgJMgLspBS87LUcknGt-hSmqNb29CH2A0ux87SdsaeRYdtmDPthmEegz3EMGAO-4jT4YRklzJNJ3qiPkQ6hW7MLHhmMbqfshv3NHiKvj-tPruR3lN-Rc499sld_-WKfDw-vG-e2fb16WVzt2UTB5OZtI1va2NKoXhTgbVgG84rpVErC41qlHa1M5XmdW1qUAigjCi5rFpfCyzlitz-_k5zM7h2N53MMH7t_sXlNxPwXJA</recordid><startdate>20210515</startdate><enddate>20210515</enddate><creator>Jiang, Shan</creator><creator>Zhang, Lvxia</creator><creator>Li, Jizhou</creator><creator>Ouyang, Hui</creator><creator>Fu, Zhifeng</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope></search><sort><creationdate>20210515</creationdate><title>Pressure/colorimetric dual-readout immunochromatographic test strip for point-of-care testing of aflatoxin B 1</title><author>Jiang, Shan ; Zhang, Lvxia ; Li, Jizhou ; Ouyang, Hui ; Fu, Zhifeng</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p108t-3cbfd9884251b60cc0cb11657a75c0b5b57e9e8671998905a005824136df92a43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Aflatoxin B1 - analysis</topic><topic>Colorimetry</topic><topic>Limit of Detection</topic><topic>Metal Nanoparticles</topic><topic>Platinum</topic><topic>Point-of-Care Testing</topic><topic>Reproducibility of Results</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jiang, Shan</creatorcontrib><creatorcontrib>Zhang, Lvxia</creatorcontrib><creatorcontrib>Li, Jizhou</creatorcontrib><creatorcontrib>Ouyang, Hui</creatorcontrib><creatorcontrib>Fu, Zhifeng</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jiang, Shan</au><au>Zhang, Lvxia</au><au>Li, Jizhou</au><au>Ouyang, Hui</au><au>Fu, Zhifeng</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Pressure/colorimetric dual-readout immunochromatographic test strip for point-of-care testing of aflatoxin B 1</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>2021-05-15</date><risdate>2021</risdate><volume>227</volume><spage>122203</spage><pages>122203-</pages><eissn>1873-3573</eissn><abstract>Immunochromatographic test strip (ITS) for point-of-care testing (POCT) has attracted prominent attention due to the advantages including rapid response, low cost and good portability. Here, we developed a sensitive ITS for detecting aflatoxin B (AFB ) by using dendritic platinum nanoparticles (DPNs) as novel pressure/colorimetric dual-readout probes. DPNs-labeled antibody of AFB were used as the signal tracer of the immunochromatographic process. After 10-min competitive immunoreaction, black color appeared on the test line of ITS due to the accumulation of DPNs, which was observed visually as a colorimetric readout for qualitation purpose. Furthermore, DPNs with peroxidase-like activity caused decomposition of hydrogen peroxide aqueous solution to produce pressure change signal in vials, which was detected by a hand-held pressure meter for quantitation purpose. With the pressure readout mode, the detection range was 0.05-10 ng mL , and the detection limit was 0.03 ng mL  (S/N = 3) for AFB . The proposed ITS was successfully utilized for detecting AFB in herbal medicine samples, and the acceptable recoveries of 93.77-114.09% indicated the reliability for real sample detection. It provides a new avenue for POCT with great application potential in various area including drug and food quality control, pollutants monitoring as well as medical diagnosis.</abstract><cop>Netherlands</cop><pmid>33714473</pmid><doi>10.1016/j.talanta.2021.122203</doi></addata></record>
fulltext fulltext
identifier EISSN: 1873-3573
ispartof Talanta (Oxford), 2021-05, Vol.227, p.122203
issn 1873-3573
language eng
recordid cdi_pubmed_primary_33714473
source MEDLINE; ScienceDirect Journals (5 years ago - present)
subjects Aflatoxin B1 - analysis
Colorimetry
Limit of Detection
Metal Nanoparticles
Platinum
Point-of-Care Testing
Reproducibility of Results
title Pressure/colorimetric dual-readout immunochromatographic test strip for point-of-care testing of aflatoxin B 1
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T14%3A21%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Pressure/colorimetric%20dual-readout%20immunochromatographic%20test%20strip%20for%20point-of-care%20testing%20of%20aflatoxin%20B%201&rft.jtitle=Talanta%20(Oxford)&rft.au=Jiang,%20Shan&rft.date=2021-05-15&rft.volume=227&rft.spage=122203&rft.pages=122203-&rft.eissn=1873-3573&rft_id=info:doi/10.1016/j.talanta.2021.122203&rft_dat=%3Cpubmed%3E33714473%3C/pubmed%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/33714473&rfr_iscdi=true