Graphene oxide-gold nanoparticle-aptamer complexed probe for detecting amyloid beta oligomer by ELISA-based immunoassay

Highly sensitive and easy detection method for Alzheimer's disease (AD) with a suitable biomarker is mandatory for preventing the factors resulting from AD. This research reports a modified ELISA with graphene for the detection of AD biomarker amyloid beta (Aβ) oligomer. Gold nanoparticle (AuNP...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of immunological methods 2021-02, Vol.489, p.112942, Article 112942
Hauptverfasser: Zhao, Jing, Chang, Wenlong, Liu, Lu, Xing, Xiaoming, Zhang, Chao, Meng, Huihong, Gopinath, Subash C.B., Lakshmipriya, Thangavel, Chen, Yeng, Liu, Yonggang
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page 112942
container_title Journal of immunological methods
container_volume 489
creator Zhao, Jing
Chang, Wenlong
Liu, Lu
Xing, Xiaoming
Zhang, Chao
Meng, Huihong
Gopinath, Subash C.B.
Lakshmipriya, Thangavel
Chen, Yeng
Liu, Yonggang
description Highly sensitive and easy detection method for Alzheimer's disease (AD) with a suitable biomarker is mandatory for preventing the factors resulting from AD. This research reports a modified ELISA with graphene for the detection of AD biomarker amyloid beta (Aβ) oligomer. Gold nanoparticle (AuNP) conjugated aptamer was used as the capture probe and attached on ELISA-graphene oxide surface through the amine linker. Antibody was used as the detection molecule to reach the maximum detection of Aβ oligomer. Suitable level of APTMS (2%), size of AuNP (30 nm) and aptamer concentration (2 μM) were optimized. This sandwich pattern of aptamer-Aβ oligomer-antibody helps to reach the detection at 50 pM on the optimized ELISA surface and the control experiments in the absence of Aβ oligomer or anti-Aβ oligomer antibody did not show the significant optical detection at 492 nm, indicting the specific detection. Further, Aβ oligomer spiked artificial cerebrospinal fluid did not interfere the detection of Aβ oligomer, confirming the selective detection. This new and modified ELISA surface helps to reach the lower detection of Aβ oligomer and diagnose AD.
doi_str_mv 10.1016/j.jim.2020.112942
format Article
fullrecord <record><control><sourceid>pubmed_elsev</sourceid><recordid>TN_cdi_pubmed_primary_33333060</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0022175920302362</els_id><sourcerecordid>33333060</sourcerecordid><originalsourceid>FETCH-LOGICAL-e230t-e94d27d91a240a9919dfeb388dda0d9a5e92f0075c5f32c92a551db65d26478f3</originalsourceid><addsrcrecordid>eNo1kN1OwzAMhSMEYmPwANygvECHk_4t4mqaxpg0iQvgOnIbd6RqmyrtgL49rQa-sS2dYx1_jN0LWAoQyWO5LG29lCDHXUgVyQs2F6tUBqmC-JLNAaQMRBqrGbvpuhIABCRwzWbhVOM4Z987j-0nNcTdjzUUHF1leIONa9H3Nq8owLbHmjzPXd1W9EOGt95lxAvnuaGe8t42R471UDlreEY9clfZo5s82cC3h_3bOsiwG422rk-Nw67D4ZZdFVh1dPfXF-zjefu-eQkOr7v9Zn0ISIbQB6QiI1OjBMoIUCmhTEFZuFoZg2AUxqRkAZDGeVyEMlcS41iYLImNTKJ0VYQL9nC-256ymoxuva3RD_qfwCh4OgtoTPFlyesut9TkZKwff9PGWS1AT7x1qUfeeuKtz7zDX8DtdDg</addsrcrecordid><sourcetype>Index Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Graphene oxide-gold nanoparticle-aptamer complexed probe for detecting amyloid beta oligomer by ELISA-based immunoassay</title><source>Access via ScienceDirect (Elsevier)</source><creator>Zhao, Jing ; Chang, Wenlong ; Liu, Lu ; Xing, Xiaoming ; Zhang, Chao ; Meng, Huihong ; Gopinath, Subash C.B. ; Lakshmipriya, Thangavel ; Chen, Yeng ; Liu, Yonggang</creator><creatorcontrib>Zhao, Jing ; Chang, Wenlong ; Liu, Lu ; Xing, Xiaoming ; Zhang, Chao ; Meng, Huihong ; Gopinath, Subash C.B. ; Lakshmipriya, Thangavel ; Chen, Yeng ; Liu, Yonggang</creatorcontrib><description>Highly sensitive and easy detection method for Alzheimer's disease (AD) with a suitable biomarker is mandatory for preventing the factors resulting from AD. This research reports a modified ELISA with graphene for the detection of AD biomarker amyloid beta (Aβ) oligomer. Gold nanoparticle (AuNP) conjugated aptamer was used as the capture probe and attached on ELISA-graphene oxide surface through the amine linker. Antibody was used as the detection molecule to reach the maximum detection of Aβ oligomer. Suitable level of APTMS (2%), size of AuNP (30 nm) and aptamer concentration (2 μM) were optimized. This sandwich pattern of aptamer-Aβ oligomer-antibody helps to reach the detection at 50 pM on the optimized ELISA surface and the control experiments in the absence of Aβ oligomer or anti-Aβ oligomer antibody did not show the significant optical detection at 492 nm, indicting the specific detection. Further, Aβ oligomer spiked artificial cerebrospinal fluid did not interfere the detection of Aβ oligomer, confirming the selective detection. This new and modified ELISA surface helps to reach the lower detection of Aβ oligomer and diagnose AD.</description><identifier>ISSN: 0022-1759</identifier><identifier>EISSN: 1872-7905</identifier><identifier>DOI: 10.1016/j.jim.2020.112942</identifier><identifier>PMID: 33333060</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Alzheimer's disease ; Aptamer ; Biomarker ; Nanomaterial</subject><ispartof>Journal of immunological methods, 2021-02, Vol.489, p.112942, Article 112942</ispartof><rights>2020 Elsevier B.V.</rights><rights>Copyright © 2020 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.jim.2020.112942$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33333060$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Zhao, Jing</creatorcontrib><creatorcontrib>Chang, Wenlong</creatorcontrib><creatorcontrib>Liu, Lu</creatorcontrib><creatorcontrib>Xing, Xiaoming</creatorcontrib><creatorcontrib>Zhang, Chao</creatorcontrib><creatorcontrib>Meng, Huihong</creatorcontrib><creatorcontrib>Gopinath, Subash C.B.</creatorcontrib><creatorcontrib>Lakshmipriya, Thangavel</creatorcontrib><creatorcontrib>Chen, Yeng</creatorcontrib><creatorcontrib>Liu, Yonggang</creatorcontrib><title>Graphene oxide-gold nanoparticle-aptamer complexed probe for detecting amyloid beta oligomer by ELISA-based immunoassay</title><title>Journal of immunological methods</title><addtitle>J Immunol Methods</addtitle><description>Highly sensitive and easy detection method for Alzheimer's disease (AD) with a suitable biomarker is mandatory for preventing the factors resulting from AD. This research reports a modified ELISA with graphene for the detection of AD biomarker amyloid beta (Aβ) oligomer. Gold nanoparticle (AuNP) conjugated aptamer was used as the capture probe and attached on ELISA-graphene oxide surface through the amine linker. Antibody was used as the detection molecule to reach the maximum detection of Aβ oligomer. Suitable level of APTMS (2%), size of AuNP (30 nm) and aptamer concentration (2 μM) were optimized. This sandwich pattern of aptamer-Aβ oligomer-antibody helps to reach the detection at 50 pM on the optimized ELISA surface and the control experiments in the absence of Aβ oligomer or anti-Aβ oligomer antibody did not show the significant optical detection at 492 nm, indicting the specific detection. Further, Aβ oligomer spiked artificial cerebrospinal fluid did not interfere the detection of Aβ oligomer, confirming the selective detection. This new and modified ELISA surface helps to reach the lower detection of Aβ oligomer and diagnose AD.</description><subject>Alzheimer's disease</subject><subject>Aptamer</subject><subject>Biomarker</subject><subject>Nanomaterial</subject><issn>0022-1759</issn><issn>1872-7905</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNo1kN1OwzAMhSMEYmPwANygvECHk_4t4mqaxpg0iQvgOnIbd6RqmyrtgL49rQa-sS2dYx1_jN0LWAoQyWO5LG29lCDHXUgVyQs2F6tUBqmC-JLNAaQMRBqrGbvpuhIABCRwzWbhVOM4Z987j-0nNcTdjzUUHF1leIONa9H3Nq8owLbHmjzPXd1W9EOGt95lxAvnuaGe8t42R471UDlreEY9clfZo5s82cC3h_3bOsiwG422rk-Nw67D4ZZdFVh1dPfXF-zjefu-eQkOr7v9Zn0ISIbQB6QiI1OjBMoIUCmhTEFZuFoZg2AUxqRkAZDGeVyEMlcS41iYLImNTKJ0VYQL9nC-256ymoxuva3RD_qfwCh4OgtoTPFlyesut9TkZKwff9PGWS1AT7x1qUfeeuKtz7zDX8DtdDg</recordid><startdate>202102</startdate><enddate>202102</enddate><creator>Zhao, Jing</creator><creator>Chang, Wenlong</creator><creator>Liu, Lu</creator><creator>Xing, Xiaoming</creator><creator>Zhang, Chao</creator><creator>Meng, Huihong</creator><creator>Gopinath, Subash C.B.</creator><creator>Lakshmipriya, Thangavel</creator><creator>Chen, Yeng</creator><creator>Liu, Yonggang</creator><general>Elsevier B.V</general><scope>NPM</scope></search><sort><creationdate>202102</creationdate><title>Graphene oxide-gold nanoparticle-aptamer complexed probe for detecting amyloid beta oligomer by ELISA-based immunoassay</title><author>Zhao, Jing ; Chang, Wenlong ; Liu, Lu ; Xing, Xiaoming ; Zhang, Chao ; Meng, Huihong ; Gopinath, Subash C.B. ; Lakshmipriya, Thangavel ; Chen, Yeng ; Liu, Yonggang</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-e230t-e94d27d91a240a9919dfeb388dda0d9a5e92f0075c5f32c92a551db65d26478f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Alzheimer's disease</topic><topic>Aptamer</topic><topic>Biomarker</topic><topic>Nanomaterial</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zhao, Jing</creatorcontrib><creatorcontrib>Chang, Wenlong</creatorcontrib><creatorcontrib>Liu, Lu</creatorcontrib><creatorcontrib>Xing, Xiaoming</creatorcontrib><creatorcontrib>Zhang, Chao</creatorcontrib><creatorcontrib>Meng, Huihong</creatorcontrib><creatorcontrib>Gopinath, Subash C.B.</creatorcontrib><creatorcontrib>Lakshmipriya, Thangavel</creatorcontrib><creatorcontrib>Chen, Yeng</creatorcontrib><creatorcontrib>Liu, Yonggang</creatorcontrib><collection>PubMed</collection><jtitle>Journal of immunological methods</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zhao, Jing</au><au>Chang, Wenlong</au><au>Liu, Lu</au><au>Xing, Xiaoming</au><au>Zhang, Chao</au><au>Meng, Huihong</au><au>Gopinath, Subash C.B.</au><au>Lakshmipriya, Thangavel</au><au>Chen, Yeng</au><au>Liu, Yonggang</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Graphene oxide-gold nanoparticle-aptamer complexed probe for detecting amyloid beta oligomer by ELISA-based immunoassay</atitle><jtitle>Journal of immunological methods</jtitle><addtitle>J Immunol Methods</addtitle><date>2021-02</date><risdate>2021</risdate><volume>489</volume><spage>112942</spage><pages>112942-</pages><artnum>112942</artnum><issn>0022-1759</issn><eissn>1872-7905</eissn><abstract>Highly sensitive and easy detection method for Alzheimer's disease (AD) with a suitable biomarker is mandatory for preventing the factors resulting from AD. This research reports a modified ELISA with graphene for the detection of AD biomarker amyloid beta (Aβ) oligomer. Gold nanoparticle (AuNP) conjugated aptamer was used as the capture probe and attached on ELISA-graphene oxide surface through the amine linker. Antibody was used as the detection molecule to reach the maximum detection of Aβ oligomer. Suitable level of APTMS (2%), size of AuNP (30 nm) and aptamer concentration (2 μM) were optimized. This sandwich pattern of aptamer-Aβ oligomer-antibody helps to reach the detection at 50 pM on the optimized ELISA surface and the control experiments in the absence of Aβ oligomer or anti-Aβ oligomer antibody did not show the significant optical detection at 492 nm, indicting the specific detection. Further, Aβ oligomer spiked artificial cerebrospinal fluid did not interfere the detection of Aβ oligomer, confirming the selective detection. This new and modified ELISA surface helps to reach the lower detection of Aβ oligomer and diagnose AD.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>33333060</pmid><doi>10.1016/j.jim.2020.112942</doi></addata></record>
fulltext fulltext
identifier ISSN: 0022-1759
ispartof Journal of immunological methods, 2021-02, Vol.489, p.112942, Article 112942
issn 0022-1759
1872-7905
language eng
recordid cdi_pubmed_primary_33333060
source Access via ScienceDirect (Elsevier)
subjects Alzheimer's disease
Aptamer
Biomarker
Nanomaterial
title Graphene oxide-gold nanoparticle-aptamer complexed probe for detecting amyloid beta oligomer by ELISA-based immunoassay
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T18%3A54%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_elsev&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Graphene%20oxide-gold%20nanoparticle-aptamer%20complexed%20probe%20for%20detecting%20amyloid%20beta%20oligomer%20by%20ELISA-based%20immunoassay&rft.jtitle=Journal%20of%20immunological%20methods&rft.au=Zhao,%20Jing&rft.date=2021-02&rft.volume=489&rft.spage=112942&rft.pages=112942-&rft.artnum=112942&rft.issn=0022-1759&rft.eissn=1872-7905&rft_id=info:doi/10.1016/j.jim.2020.112942&rft_dat=%3Cpubmed_elsev%3E33333060%3C/pubmed_elsev%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/33333060&rft_els_id=S0022175920302362&rfr_iscdi=true