Paradoxical intraoperative embolism in a patient with Eisenmenger syndrome undergoing hip arthroplasty
Hip arthroplasty is associated with a high incidence of embolic events that, although usually not relevant at a clinical level, may be an important cause of morbidity and mortality in certain situations. Extreme caution should be taken in patients with cardiac defects that favor communication betwee...
Gespeichert in:
Veröffentlicht in: | Revista española de anestesiología y reanimación 2019-10, Vol.66 (8), p.439 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng ; spa |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 8 |
container_start_page | 439 |
container_title | Revista española de anestesiología y reanimación |
container_volume | 66 |
creator | Tomé Roca, J L López Martín, R Baca Morilla, Y de la Linde Valverde, C |
description | Hip arthroplasty is associated with a high incidence of embolic events that, although usually not relevant at a clinical level, may be an important cause of morbidity and mortality in certain situations. Extreme caution should be taken in patients with cardiac defects that favor communication between the pulmonary and systemic circulation, due to their greater risk of complications. We present the case of a 72-year-old patient who suffered a paradoxical embolism during the intervention, with devastating consequences. |
doi_str_mv | 10.1016/j.redar.2019.03.014 |
format | Article |
fullrecord | <record><control><sourceid>pubmed</sourceid><recordid>TN_cdi_pubmed_primary_31327534</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>31327534</sourcerecordid><originalsourceid>FETCH-LOGICAL-p211t-ec32552c3257b8f8a2c3de52bf708a7a8b5967c879e09d664db23e9380ab80ad3</originalsourceid><addsrcrecordid>eNo1T1tLwzAYDYK4MfcLBMkfaM2ladNHGfMCA33Q5_Fl-bpltGlIMnX_3op64Fw4DwcOITeclZzx-u5YRrQQS8F4WzJZMl5dkLmQFSuk0NWMLFM6sgm1YqJSV2QmuRSNktWcdK8QwY5fbgc9dT5HGANGyO4DKQ5m7F0app4CDVOJPtNPlw907RL6Af0eI01nb-M4ID15i3E_Or-nBxcoxHyIY-gh5fM1ueygT7j88wV5f1i_rZ6Kzcvj8-p-UwTBeS5wJ4VS4kcbozsNU7SohOkapqEBbVRbNzvdtMhaW9eVNUJiKzUDM9HKBbn93Q0nM6DdhugGiOft_2H5Dc-8Wug</addsrcrecordid><sourcetype>Index Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Paradoxical intraoperative embolism in a patient with Eisenmenger syndrome undergoing hip arthroplasty</title><source>Alma/SFX Local Collection</source><creator>Tomé Roca, J L ; López Martín, R ; Baca Morilla, Y ; de la Linde Valverde, C</creator><creatorcontrib>Tomé Roca, J L ; López Martín, R ; Baca Morilla, Y ; de la Linde Valverde, C</creatorcontrib><description>Hip arthroplasty is associated with a high incidence of embolic events that, although usually not relevant at a clinical level, may be an important cause of morbidity and mortality in certain situations. Extreme caution should be taken in patients with cardiac defects that favor communication between the pulmonary and systemic circulation, due to their greater risk of complications. We present the case of a 72-year-old patient who suffered a paradoxical embolism during the intervention, with devastating consequences.</description><identifier>EISSN: 2340-3284</identifier><identifier>DOI: 10.1016/j.redar.2019.03.014</identifier><identifier>PMID: 31327534</identifier><language>eng ; spa</language><publisher>Spain</publisher><ispartof>Revista española de anestesiología y reanimación, 2019-10, Vol.66 (8), p.439</ispartof><rights>Copyright © 2019 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31327534$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Tomé Roca, J L</creatorcontrib><creatorcontrib>López Martín, R</creatorcontrib><creatorcontrib>Baca Morilla, Y</creatorcontrib><creatorcontrib>de la Linde Valverde, C</creatorcontrib><title>Paradoxical intraoperative embolism in a patient with Eisenmenger syndrome undergoing hip arthroplasty</title><title>Revista española de anestesiología y reanimación</title><addtitle>Rev Esp Anestesiol Reanim</addtitle><description>Hip arthroplasty is associated with a high incidence of embolic events that, although usually not relevant at a clinical level, may be an important cause of morbidity and mortality in certain situations. Extreme caution should be taken in patients with cardiac defects that favor communication between the pulmonary and systemic circulation, due to their greater risk of complications. We present the case of a 72-year-old patient who suffered a paradoxical embolism during the intervention, with devastating consequences.</description><issn>2340-3284</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNo1T1tLwzAYDYK4MfcLBMkfaM2ladNHGfMCA33Q5_Fl-bpltGlIMnX_3op64Fw4DwcOITeclZzx-u5YRrQQS8F4WzJZMl5dkLmQFSuk0NWMLFM6sgm1YqJSV2QmuRSNktWcdK8QwY5fbgc9dT5HGANGyO4DKQ5m7F0app4CDVOJPtNPlw907RL6Af0eI01nb-M4ID15i3E_Or-nBxcoxHyIY-gh5fM1ueygT7j88wV5f1i_rZ6Kzcvj8-p-UwTBeS5wJ4VS4kcbozsNU7SohOkapqEBbVRbNzvdtMhaW9eVNUJiKzUDM9HKBbn93Q0nM6DdhugGiOft_2H5Dc-8Wug</recordid><startdate>201910</startdate><enddate>201910</enddate><creator>Tomé Roca, J L</creator><creator>López Martín, R</creator><creator>Baca Morilla, Y</creator><creator>de la Linde Valverde, C</creator><scope>NPM</scope></search><sort><creationdate>201910</creationdate><title>Paradoxical intraoperative embolism in a patient with Eisenmenger syndrome undergoing hip arthroplasty</title><author>Tomé Roca, J L ; López Martín, R ; Baca Morilla, Y ; de la Linde Valverde, C</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p211t-ec32552c3257b8f8a2c3de52bf708a7a8b5967c879e09d664db23e9380ab80ad3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; spa</language><creationdate>2019</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tomé Roca, J L</creatorcontrib><creatorcontrib>López Martín, R</creatorcontrib><creatorcontrib>Baca Morilla, Y</creatorcontrib><creatorcontrib>de la Linde Valverde, C</creatorcontrib><collection>PubMed</collection><jtitle>Revista española de anestesiología y reanimación</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tomé Roca, J L</au><au>López Martín, R</au><au>Baca Morilla, Y</au><au>de la Linde Valverde, C</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Paradoxical intraoperative embolism in a patient with Eisenmenger syndrome undergoing hip arthroplasty</atitle><jtitle>Revista española de anestesiología y reanimación</jtitle><addtitle>Rev Esp Anestesiol Reanim</addtitle><date>2019-10</date><risdate>2019</risdate><volume>66</volume><issue>8</issue><spage>439</spage><pages>439-</pages><eissn>2340-3284</eissn><abstract>Hip arthroplasty is associated with a high incidence of embolic events that, although usually not relevant at a clinical level, may be an important cause of morbidity and mortality in certain situations. Extreme caution should be taken in patients with cardiac defects that favor communication between the pulmonary and systemic circulation, due to their greater risk of complications. We present the case of a 72-year-old patient who suffered a paradoxical embolism during the intervention, with devastating consequences.</abstract><cop>Spain</cop><pmid>31327534</pmid><doi>10.1016/j.redar.2019.03.014</doi></addata></record> |
fulltext | fulltext |
identifier | EISSN: 2340-3284 |
ispartof | Revista española de anestesiología y reanimación, 2019-10, Vol.66 (8), p.439 |
issn | 2340-3284 |
language | eng ; spa |
recordid | cdi_pubmed_primary_31327534 |
source | Alma/SFX Local Collection |
title | Paradoxical intraoperative embolism in a patient with Eisenmenger syndrome undergoing hip arthroplasty |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T16%3A26%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Paradoxical%20intraoperative%20embolism%20in%20a%20patient%20with%20Eisenmenger%20syndrome%20undergoing%20hip%20arthroplasty&rft.jtitle=Revista%20espa%C3%B1ola%20de%20anestesiolog%C3%ADa%20y%20reanimaci%C3%B3n&rft.au=Tom%C3%A9%20Roca,%20J%20L&rft.date=2019-10&rft.volume=66&rft.issue=8&rft.spage=439&rft.pages=439-&rft.eissn=2340-3284&rft_id=info:doi/10.1016/j.redar.2019.03.014&rft_dat=%3Cpubmed%3E31327534%3C/pubmed%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/31327534&rfr_iscdi=true |