Comparative analysis of fixation configurations and their effect on outcome after medial open-wedge high tibial osteotomy

The purposes of this study were to analyze and compare 1) the postoperative fixation configurations, and 2) radiological and clinical outcomes between the new conceptual fixation device (LCfit) and the conventional locking plates. Retrospective comparative analysis of 304 cases who underwent open-we...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association 2020-07, Vol.25 (4), p.627-634
Hauptverfasser: Lee, Eui Soo, Kim, Tae Woo, Jo, In Ho, Lee, Yong Seuk
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 634
container_issue 4
container_start_page 627
container_title Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association
container_volume 25
creator Lee, Eui Soo
Kim, Tae Woo
Jo, In Ho
Lee, Yong Seuk
description The purposes of this study were to analyze and compare 1) the postoperative fixation configurations, and 2) radiological and clinical outcomes between the new conceptual fixation device (LCfit) and the conventional locking plates. Retrospective comparative analysis of 304 cases who underwent open-wedge high tibial osteotomy with four different locking plate systems including the LCfit system was conducted. In analyzing the fixation configuration of each locking plate system, the plate position, the gap between plate and bone, screw angle, and screw length were evaluated from postoperative CT scans. The clinical outcomes and radiological parameters of four patient groups corresponding to the four locking plate systems were also compared. In the analysis of the fixation configurations, the LCfit system showed more posteromedial plate position, decreased gap between plate and bone, reduced screw angle, and longer screw length compared to the other three locking plates. However, there were no significant differences in clinical outcomes and radiological parameters such as hip-knee-ankle angle, weight-bearing line position, medial proximal tibial angle, and posterior slope between the four groups. The newly designed fixation system (LCfit) for open-wedge high tibial osteotomy showed fixation configurations that have theoretical mechanical advantages over conventional anatomical locking plates. However, there were no significant differences in clinical outcomes and radiological parameters between LCfit and the other locking plate systems. Level III, retrospective cohort study.
doi_str_mv 10.1016/j.jos.2019.06.018
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_pubmed_primary_31320145</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0949265819302027</els_id><sourcerecordid>2261244945</sourcerecordid><originalsourceid>FETCH-LOGICAL-c377t-9871b2cffcb42b6b9faf413ecb839e35cf4dd2ac9690a171ab207de23cf14ca43</originalsourceid><addsrcrecordid>eNp9kMtu2zAQRYkiRe26_YBuCi6zkcqXJBNZBUbaBjDQTbsmKGpo05BEh6Sc-O9DP5JlV4MZnHuBOQh9o6SkhNY_duXOx5IRKktSl4QuP6A5FbwuGGH8Bs2JFLJgdbWcoc8x7gihTSWrT2jGKc8pUc3RceWHvQ46uQNgPer-GF3E3mLrXvLRj9j40brNFM5bzEyH0xZcwGAtmIQz4qdk_JDzNkHAA3RO99jvYSyeodsA3rrNFifXns8xgU9-OH5BH63uI3y9zgX69_Ph7-p3sf7z63F1vy4Mb5pUyGVDW2asNa1gbd1Kq62gHEy75BJ4ZazoOqaNrCXRtKG6ZaTpgHFjqTBa8AW6vfTug3-aICY1uGig7_UIfoqKsZoyIaSoMkovqAk-xgBW7YMbdDgqStTJuNqpbFydjCtSq2w8Z75f66c2f_6eeFOcgbsLAPnJg4OgonEwmmwpZH-q8-4_9a_f_JS8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2261244945</pqid></control><display><type>article</type><title>Comparative analysis of fixation configurations and their effect on outcome after medial open-wedge high tibial osteotomy</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Lee, Eui Soo ; Kim, Tae Woo ; Jo, In Ho ; Lee, Yong Seuk</creator><creatorcontrib>Lee, Eui Soo ; Kim, Tae Woo ; Jo, In Ho ; Lee, Yong Seuk</creatorcontrib><description>The purposes of this study were to analyze and compare 1) the postoperative fixation configurations, and 2) radiological and clinical outcomes between the new conceptual fixation device (LCfit) and the conventional locking plates. Retrospective comparative analysis of 304 cases who underwent open-wedge high tibial osteotomy with four different locking plate systems including the LCfit system was conducted. In analyzing the fixation configuration of each locking plate system, the plate position, the gap between plate and bone, screw angle, and screw length were evaluated from postoperative CT scans. The clinical outcomes and radiological parameters of four patient groups corresponding to the four locking plate systems were also compared. In the analysis of the fixation configurations, the LCfit system showed more posteromedial plate position, decreased gap between plate and bone, reduced screw angle, and longer screw length compared to the other three locking plates. However, there were no significant differences in clinical outcomes and radiological parameters such as hip-knee-ankle angle, weight-bearing line position, medial proximal tibial angle, and posterior slope between the four groups. The newly designed fixation system (LCfit) for open-wedge high tibial osteotomy showed fixation configurations that have theoretical mechanical advantages over conventional anatomical locking plates. However, there were no significant differences in clinical outcomes and radiological parameters between LCfit and the other locking plate systems. Level III, retrospective cohort study.</description><identifier>ISSN: 0949-2658</identifier><identifier>EISSN: 1436-2023</identifier><identifier>DOI: 10.1016/j.jos.2019.06.018</identifier><identifier>PMID: 31320145</identifier><language>eng</language><publisher>Japan: Elsevier B.V</publisher><subject>Disability Evaluation ; Equipment Design ; Female ; Humans ; Internal Fixators ; Male ; Middle Aged ; Osteoarthritis, Knee - diagnostic imaging ; Osteoarthritis, Knee - surgery ; Osteotomy - instrumentation ; Osteotomy - methods ; Retrospective Studies</subject><ispartof>Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association, 2020-07, Vol.25 (4), p.627-634</ispartof><rights>2019 The Japanese Orthopaedic Association</rights><rights>Copyright © 2019 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c377t-9871b2cffcb42b6b9faf413ecb839e35cf4dd2ac9690a171ab207de23cf14ca43</citedby><cites>FETCH-LOGICAL-c377t-9871b2cffcb42b6b9faf413ecb839e35cf4dd2ac9690a171ab207de23cf14ca43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27905,27906</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31320145$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lee, Eui Soo</creatorcontrib><creatorcontrib>Kim, Tae Woo</creatorcontrib><creatorcontrib>Jo, In Ho</creatorcontrib><creatorcontrib>Lee, Yong Seuk</creatorcontrib><title>Comparative analysis of fixation configurations and their effect on outcome after medial open-wedge high tibial osteotomy</title><title>Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association</title><addtitle>J Orthop Sci</addtitle><description>The purposes of this study were to analyze and compare 1) the postoperative fixation configurations, and 2) radiological and clinical outcomes between the new conceptual fixation device (LCfit) and the conventional locking plates. Retrospective comparative analysis of 304 cases who underwent open-wedge high tibial osteotomy with four different locking plate systems including the LCfit system was conducted. In analyzing the fixation configuration of each locking plate system, the plate position, the gap between plate and bone, screw angle, and screw length were evaluated from postoperative CT scans. The clinical outcomes and radiological parameters of four patient groups corresponding to the four locking plate systems were also compared. In the analysis of the fixation configurations, the LCfit system showed more posteromedial plate position, decreased gap between plate and bone, reduced screw angle, and longer screw length compared to the other three locking plates. However, there were no significant differences in clinical outcomes and radiological parameters such as hip-knee-ankle angle, weight-bearing line position, medial proximal tibial angle, and posterior slope between the four groups. The newly designed fixation system (LCfit) for open-wedge high tibial osteotomy showed fixation configurations that have theoretical mechanical advantages over conventional anatomical locking plates. However, there were no significant differences in clinical outcomes and radiological parameters between LCfit and the other locking plate systems. Level III, retrospective cohort study.</description><subject>Disability Evaluation</subject><subject>Equipment Design</subject><subject>Female</subject><subject>Humans</subject><subject>Internal Fixators</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Osteoarthritis, Knee - diagnostic imaging</subject><subject>Osteoarthritis, Knee - surgery</subject><subject>Osteotomy - instrumentation</subject><subject>Osteotomy - methods</subject><subject>Retrospective Studies</subject><issn>0949-2658</issn><issn>1436-2023</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kMtu2zAQRYkiRe26_YBuCi6zkcqXJBNZBUbaBjDQTbsmKGpo05BEh6Sc-O9DP5JlV4MZnHuBOQh9o6SkhNY_duXOx5IRKktSl4QuP6A5FbwuGGH8Bs2JFLJgdbWcoc8x7gihTSWrT2jGKc8pUc3RceWHvQ46uQNgPer-GF3E3mLrXvLRj9j40brNFM5bzEyH0xZcwGAtmIQz4qdk_JDzNkHAA3RO99jvYSyeodsA3rrNFifXns8xgU9-OH5BH63uI3y9zgX69_Ph7-p3sf7z63F1vy4Mb5pUyGVDW2asNa1gbd1Kq62gHEy75BJ4ZazoOqaNrCXRtKG6ZaTpgHFjqTBa8AW6vfTug3-aICY1uGig7_UIfoqKsZoyIaSoMkovqAk-xgBW7YMbdDgqStTJuNqpbFydjCtSq2w8Z75f66c2f_6eeFOcgbsLAPnJg4OgonEwmmwpZH-q8-4_9a_f_JS8</recordid><startdate>202007</startdate><enddate>202007</enddate><creator>Lee, Eui Soo</creator><creator>Kim, Tae Woo</creator><creator>Jo, In Ho</creator><creator>Lee, Yong Seuk</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>202007</creationdate><title>Comparative analysis of fixation configurations and their effect on outcome after medial open-wedge high tibial osteotomy</title><author>Lee, Eui Soo ; Kim, Tae Woo ; Jo, In Ho ; Lee, Yong Seuk</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c377t-9871b2cffcb42b6b9faf413ecb839e35cf4dd2ac9690a171ab207de23cf14ca43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Disability Evaluation</topic><topic>Equipment Design</topic><topic>Female</topic><topic>Humans</topic><topic>Internal Fixators</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Osteoarthritis, Knee - diagnostic imaging</topic><topic>Osteoarthritis, Knee - surgery</topic><topic>Osteotomy - instrumentation</topic><topic>Osteotomy - methods</topic><topic>Retrospective Studies</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lee, Eui Soo</creatorcontrib><creatorcontrib>Kim, Tae Woo</creatorcontrib><creatorcontrib>Jo, In Ho</creatorcontrib><creatorcontrib>Lee, Yong Seuk</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lee, Eui Soo</au><au>Kim, Tae Woo</au><au>Jo, In Ho</au><au>Lee, Yong Seuk</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparative analysis of fixation configurations and their effect on outcome after medial open-wedge high tibial osteotomy</atitle><jtitle>Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association</jtitle><addtitle>J Orthop Sci</addtitle><date>2020-07</date><risdate>2020</risdate><volume>25</volume><issue>4</issue><spage>627</spage><epage>634</epage><pages>627-634</pages><issn>0949-2658</issn><eissn>1436-2023</eissn><abstract>The purposes of this study were to analyze and compare 1) the postoperative fixation configurations, and 2) radiological and clinical outcomes between the new conceptual fixation device (LCfit) and the conventional locking plates. Retrospective comparative analysis of 304 cases who underwent open-wedge high tibial osteotomy with four different locking plate systems including the LCfit system was conducted. In analyzing the fixation configuration of each locking plate system, the plate position, the gap between plate and bone, screw angle, and screw length were evaluated from postoperative CT scans. The clinical outcomes and radiological parameters of four patient groups corresponding to the four locking plate systems were also compared. In the analysis of the fixation configurations, the LCfit system showed more posteromedial plate position, decreased gap between plate and bone, reduced screw angle, and longer screw length compared to the other three locking plates. However, there were no significant differences in clinical outcomes and radiological parameters such as hip-knee-ankle angle, weight-bearing line position, medial proximal tibial angle, and posterior slope between the four groups. The newly designed fixation system (LCfit) for open-wedge high tibial osteotomy showed fixation configurations that have theoretical mechanical advantages over conventional anatomical locking plates. However, there were no significant differences in clinical outcomes and radiological parameters between LCfit and the other locking plate systems. Level III, retrospective cohort study.</abstract><cop>Japan</cop><pub>Elsevier B.V</pub><pmid>31320145</pmid><doi>10.1016/j.jos.2019.06.018</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0949-2658
ispartof Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association, 2020-07, Vol.25 (4), p.627-634
issn 0949-2658
1436-2023
language eng
recordid cdi_pubmed_primary_31320145
source MEDLINE; Alma/SFX Local Collection
subjects Disability Evaluation
Equipment Design
Female
Humans
Internal Fixators
Male
Middle Aged
Osteoarthritis, Knee - diagnostic imaging
Osteoarthritis, Knee - surgery
Osteotomy - instrumentation
Osteotomy - methods
Retrospective Studies
title Comparative analysis of fixation configurations and their effect on outcome after medial open-wedge high tibial osteotomy
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T06%3A37%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparative%20analysis%20of%20fixation%20configurations%20and%20their%20effect%20on%20outcome%20after%20medial%20open-wedge%20high%20tibial%20osteotomy&rft.jtitle=Journal%20of%20orthopaedic%20science%20:%20official%20journal%20of%20the%20Japanese%20Orthopaedic%20Association&rft.au=Lee,%20Eui%20Soo&rft.date=2020-07&rft.volume=25&rft.issue=4&rft.spage=627&rft.epage=634&rft.pages=627-634&rft.issn=0949-2658&rft.eissn=1436-2023&rft_id=info:doi/10.1016/j.jos.2019.06.018&rft_dat=%3Cproquest_cross%3E2261244945%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2261244945&rft_id=info:pmid/31320145&rft_els_id=S0949265819302027&rfr_iscdi=true