A parallelized molecular collision cross section package with optimized accuracy and efficiency
Ion mobility-based separation prior to mass spectrometry has become an invaluable tool in the structural elucidation of gas-phase ions and in the characterization of complex mixtures. Application of ion mobility to structural studies requires an accurate methodology to bridge theoretical modelling o...
Gespeichert in:
Veröffentlicht in: | Analyst (London) 2019-02, Vol.144 (5), p.166-167 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 167 |
---|---|
container_issue | 5 |
container_start_page | 166 |
container_title | Analyst (London) |
container_volume | 144 |
creator | Ieritano, Christian Crouse, Jeff Campbell, J. Larry Hopkins, W. Scott |
description | Ion mobility-based separation prior to mass spectrometry has become an invaluable tool in the structural elucidation of gas-phase ions and in the characterization of complex mixtures. Application of ion mobility to structural studies requires an accurate methodology to bridge theoretical modelling of chemical structure with experimental determination of an ion's collision cross section (CCS). Herein, we present a refined methodology for calculating ion CCS using parallel computing architectures that makes use of atom specific parameters, which we have called MobCal-MPI. Tuning of ion-nitrogen van der Waals potentials on a diverse calibration set of 162 molecules returned a RMSE of 2.60% in CCS calculations of molecules containing the elements C, H, O, N, F, P, S, Cl, Br, and I. External validation of the ion-nitrogen potential was performed on an additional 50 compounds not present in the validation set, returning a RMSE of 2.31% for the CCSs of these compounds. Owing to the use of parameters from the MMFF94 forcefield, the calibration of the van der Waals potential can be extended to additional atoms defined in the MMFF94 forcefield (
i.e.
, Li, Na, K, Si, Mg, Ca, Fe, Cu, Zn). We expect that the work presented here will serve as a foundation for facile determination of molecular CCSs, as MobCal-MPI boasts up to 64-fold speedups over traditional calculation packages.
A new parallelized calculation package predicts collision cross sections with high accuracy and efficiency. |
doi_str_mv | 10.1039/c8an02150c |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmed_primary_30649115</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2179381891</sourcerecordid><originalsourceid>FETCH-LOGICAL-c373t-607cef69eb57c0a76c69bc619986c4f75fcff13e2f0898a8413f0e731996abcd3</originalsourceid><addsrcrecordid>eNpd0ctrGzEQB2AREmLHzaX3BEEuobCttFpppaMxfQRMe0nOizwepXK1j0i7BOev7_pRF3ISgz4NMz8R8pGzz5wJ8wW0bVjOJYMzMuVCFZmUuT4nU8aYyHIliwm5SmkzlpxJdkkmgqnCcC6npJrTzkYbAgb_hmtatwFhCDZSaEPwybcNhdimRBNCv6s6C3_sM9JX3_-mbdf7ev_QAgzRwpbaZk3ROQ8eG9h-IBfOhoTXx3NGnr59fVz8yJa_vj8s5ssMRCn6TLES0CmDK1kCs6UCZVaguDFaQeFK6cA5LjB3TBttdcGFY1iKESi7grWYkftD3y62LwOmvqp9AgzBNtgOqcp5aYTm2vCR3r2jm3aIzTjdqLSUWpXjTDPy6aD220d0VRd9beO24qzaxV4t9PznPvbFiG-PLYdVjesT_ZfzCG4OICY43f7_N_EXsFaHgA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2185586737</pqid></control><display><type>article</type><title>A parallelized molecular collision cross section package with optimized accuracy and efficiency</title><source>Royal Society of Chemistry Journals Archive (1841-2007)</source><source>Royal Society Of Chemistry Journals 2008-</source><source>Alma/SFX Local Collection</source><creator>Ieritano, Christian ; Crouse, Jeff ; Campbell, J. Larry ; Hopkins, W. Scott</creator><creatorcontrib>Ieritano, Christian ; Crouse, Jeff ; Campbell, J. Larry ; Hopkins, W. Scott</creatorcontrib><description>Ion mobility-based separation prior to mass spectrometry has become an invaluable tool in the structural elucidation of gas-phase ions and in the characterization of complex mixtures. Application of ion mobility to structural studies requires an accurate methodology to bridge theoretical modelling of chemical structure with experimental determination of an ion's collision cross section (CCS). Herein, we present a refined methodology for calculating ion CCS using parallel computing architectures that makes use of atom specific parameters, which we have called MobCal-MPI. Tuning of ion-nitrogen van der Waals potentials on a diverse calibration set of 162 molecules returned a RMSE of 2.60% in CCS calculations of molecules containing the elements C, H, O, N, F, P, S, Cl, Br, and I. External validation of the ion-nitrogen potential was performed on an additional 50 compounds not present in the validation set, returning a RMSE of 2.31% for the CCSs of these compounds. Owing to the use of parameters from the MMFF94 forcefield, the calibration of the van der Waals potential can be extended to additional atoms defined in the MMFF94 forcefield (
i.e.
, Li, Na, K, Si, Mg, Ca, Fe, Cu, Zn). We expect that the work presented here will serve as a foundation for facile determination of molecular CCSs, as MobCal-MPI boasts up to 64-fold speedups over traditional calculation packages.
A new parallelized calculation package predicts collision cross sections with high accuracy and efficiency.</description><identifier>ISSN: 0003-2654</identifier><identifier>EISSN: 1364-5528</identifier><identifier>DOI: 10.1039/c8an02150c</identifier><identifier>PMID: 30649115</identifier><language>eng</language><publisher>England: Royal Society of Chemistry</publisher><subject>Bridges ; Calcium ; Calibration ; Cross-sections ; Ionic mobility ; Magnesium ; Mass spectrometry ; Molecular collisions ; Nitrogen ; Organic chemistry ; Parallel processing ; Parameters ; Zinc</subject><ispartof>Analyst (London), 2019-02, Vol.144 (5), p.166-167</ispartof><rights>Copyright Royal Society of Chemistry 2019</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c373t-607cef69eb57c0a76c69bc619986c4f75fcff13e2f0898a8413f0e731996abcd3</citedby><cites>FETCH-LOGICAL-c373t-607cef69eb57c0a76c69bc619986c4f75fcff13e2f0898a8413f0e731996abcd3</cites><orcidid>0000-0003-4748-6346 ; 0000-0003-1617-9220</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,2829,2830,27922,27923</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30649115$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ieritano, Christian</creatorcontrib><creatorcontrib>Crouse, Jeff</creatorcontrib><creatorcontrib>Campbell, J. Larry</creatorcontrib><creatorcontrib>Hopkins, W. Scott</creatorcontrib><title>A parallelized molecular collision cross section package with optimized accuracy and efficiency</title><title>Analyst (London)</title><addtitle>Analyst</addtitle><description>Ion mobility-based separation prior to mass spectrometry has become an invaluable tool in the structural elucidation of gas-phase ions and in the characterization of complex mixtures. Application of ion mobility to structural studies requires an accurate methodology to bridge theoretical modelling of chemical structure with experimental determination of an ion's collision cross section (CCS). Herein, we present a refined methodology for calculating ion CCS using parallel computing architectures that makes use of atom specific parameters, which we have called MobCal-MPI. Tuning of ion-nitrogen van der Waals potentials on a diverse calibration set of 162 molecules returned a RMSE of 2.60% in CCS calculations of molecules containing the elements C, H, O, N, F, P, S, Cl, Br, and I. External validation of the ion-nitrogen potential was performed on an additional 50 compounds not present in the validation set, returning a RMSE of 2.31% for the CCSs of these compounds. Owing to the use of parameters from the MMFF94 forcefield, the calibration of the van der Waals potential can be extended to additional atoms defined in the MMFF94 forcefield (
i.e.
, Li, Na, K, Si, Mg, Ca, Fe, Cu, Zn). We expect that the work presented here will serve as a foundation for facile determination of molecular CCSs, as MobCal-MPI boasts up to 64-fold speedups over traditional calculation packages.
A new parallelized calculation package predicts collision cross sections with high accuracy and efficiency.</description><subject>Bridges</subject><subject>Calcium</subject><subject>Calibration</subject><subject>Cross-sections</subject><subject>Ionic mobility</subject><subject>Magnesium</subject><subject>Mass spectrometry</subject><subject>Molecular collisions</subject><subject>Nitrogen</subject><subject>Organic chemistry</subject><subject>Parallel processing</subject><subject>Parameters</subject><subject>Zinc</subject><issn>0003-2654</issn><issn>1364-5528</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNpd0ctrGzEQB2AREmLHzaX3BEEuobCttFpppaMxfQRMe0nOizwepXK1j0i7BOev7_pRF3ISgz4NMz8R8pGzz5wJ8wW0bVjOJYMzMuVCFZmUuT4nU8aYyHIliwm5SmkzlpxJdkkmgqnCcC6npJrTzkYbAgb_hmtatwFhCDZSaEPwybcNhdimRBNCv6s6C3_sM9JX3_-mbdf7ev_QAgzRwpbaZk3ROQ8eG9h-IBfOhoTXx3NGnr59fVz8yJa_vj8s5ssMRCn6TLES0CmDK1kCs6UCZVaguDFaQeFK6cA5LjB3TBttdcGFY1iKESi7grWYkftD3y62LwOmvqp9AgzBNtgOqcp5aYTm2vCR3r2jm3aIzTjdqLSUWpXjTDPy6aD220d0VRd9beO24qzaxV4t9PznPvbFiG-PLYdVjesT_ZfzCG4OICY43f7_N_EXsFaHgA</recordid><startdate>20190225</startdate><enddate>20190225</enddate><creator>Ieritano, Christian</creator><creator>Crouse, Jeff</creator><creator>Campbell, J. Larry</creator><creator>Hopkins, W. Scott</creator><general>Royal Society of Chemistry</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-4748-6346</orcidid><orcidid>https://orcid.org/0000-0003-1617-9220</orcidid></search><sort><creationdate>20190225</creationdate><title>A parallelized molecular collision cross section package with optimized accuracy and efficiency</title><author>Ieritano, Christian ; Crouse, Jeff ; Campbell, J. Larry ; Hopkins, W. Scott</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c373t-607cef69eb57c0a76c69bc619986c4f75fcff13e2f0898a8413f0e731996abcd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Bridges</topic><topic>Calcium</topic><topic>Calibration</topic><topic>Cross-sections</topic><topic>Ionic mobility</topic><topic>Magnesium</topic><topic>Mass spectrometry</topic><topic>Molecular collisions</topic><topic>Nitrogen</topic><topic>Organic chemistry</topic><topic>Parallel processing</topic><topic>Parameters</topic><topic>Zinc</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ieritano, Christian</creatorcontrib><creatorcontrib>Crouse, Jeff</creatorcontrib><creatorcontrib>Campbell, J. Larry</creatorcontrib><creatorcontrib>Hopkins, W. Scott</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Analyst (London)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ieritano, Christian</au><au>Crouse, Jeff</au><au>Campbell, J. Larry</au><au>Hopkins, W. Scott</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A parallelized molecular collision cross section package with optimized accuracy and efficiency</atitle><jtitle>Analyst (London)</jtitle><addtitle>Analyst</addtitle><date>2019-02-25</date><risdate>2019</risdate><volume>144</volume><issue>5</issue><spage>166</spage><epage>167</epage><pages>166-167</pages><issn>0003-2654</issn><eissn>1364-5528</eissn><abstract>Ion mobility-based separation prior to mass spectrometry has become an invaluable tool in the structural elucidation of gas-phase ions and in the characterization of complex mixtures. Application of ion mobility to structural studies requires an accurate methodology to bridge theoretical modelling of chemical structure with experimental determination of an ion's collision cross section (CCS). Herein, we present a refined methodology for calculating ion CCS using parallel computing architectures that makes use of atom specific parameters, which we have called MobCal-MPI. Tuning of ion-nitrogen van der Waals potentials on a diverse calibration set of 162 molecules returned a RMSE of 2.60% in CCS calculations of molecules containing the elements C, H, O, N, F, P, S, Cl, Br, and I. External validation of the ion-nitrogen potential was performed on an additional 50 compounds not present in the validation set, returning a RMSE of 2.31% for the CCSs of these compounds. Owing to the use of parameters from the MMFF94 forcefield, the calibration of the van der Waals potential can be extended to additional atoms defined in the MMFF94 forcefield (
i.e.
, Li, Na, K, Si, Mg, Ca, Fe, Cu, Zn). We expect that the work presented here will serve as a foundation for facile determination of molecular CCSs, as MobCal-MPI boasts up to 64-fold speedups over traditional calculation packages.
A new parallelized calculation package predicts collision cross sections with high accuracy and efficiency.</abstract><cop>England</cop><pub>Royal Society of Chemistry</pub><pmid>30649115</pmid><doi>10.1039/c8an02150c</doi><tpages>11</tpages><orcidid>https://orcid.org/0000-0003-4748-6346</orcidid><orcidid>https://orcid.org/0000-0003-1617-9220</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2654 |
ispartof | Analyst (London), 2019-02, Vol.144 (5), p.166-167 |
issn | 0003-2654 1364-5528 |
language | eng |
recordid | cdi_pubmed_primary_30649115 |
source | Royal Society of Chemistry Journals Archive (1841-2007); Royal Society Of Chemistry Journals 2008-; Alma/SFX Local Collection |
subjects | Bridges Calcium Calibration Cross-sections Ionic mobility Magnesium Mass spectrometry Molecular collisions Nitrogen Organic chemistry Parallel processing Parameters Zinc |
title | A parallelized molecular collision cross section package with optimized accuracy and efficiency |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T22%3A42%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20parallelized%20molecular%20collision%20cross%20section%20package%20with%20optimized%20accuracy%20and%20efficiency&rft.jtitle=Analyst%20(London)&rft.au=Ieritano,%20Christian&rft.date=2019-02-25&rft.volume=144&rft.issue=5&rft.spage=166&rft.epage=167&rft.pages=166-167&rft.issn=0003-2654&rft.eissn=1364-5528&rft_id=info:doi/10.1039/c8an02150c&rft_dat=%3Cproquest_pubme%3E2179381891%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2185586737&rft_id=info:pmid/30649115&rfr_iscdi=true |