Enhancement of gravimetric forced flow through system to determine sorption, swelling, and mass transfer characteristics of liquid sorbents

An existing apparatus for forced flow through of liquid sorbents has been enhanced with an optically accessible system including a transparent crucible, high pressure viewing cell, and camera. With this optical system, the active surface area between gas and liquid can be determined in situ for the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Review of scientific instruments 2018-04, Vol.89 (4), p.045102-045102
Hauptverfasser: Dresp, G., Petermann, M., Fieback, T. M.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 045102
container_issue 4
container_start_page 045102
container_title Review of scientific instruments
container_volume 89
creator Dresp, G.
Petermann, M.
Fieback, T. M.
description An existing apparatus for forced flow through of liquid sorbents has been enhanced with an optically accessible system including a transparent crucible, high pressure viewing cell, and camera. With this optical system, the active surface area between gas and liquid can be determined in situ for the first time under industrial process conditions while maintaining the accuracy of a magnetic suspension balance. Additionally, occurring swelling and the resulting buoyancy changes can now be corrected, further improving the quality of the data. Validation measurements focusing on the sorption isotherms, swelling, and bubble geometry of 1-butyl-3-methylimidazolium tetrafluoroborate with nitrogen at 303 K and up to 17 MPa, as well as with carbon dioxide at 303 K, 323 K, and 373 K at up to 3.5 MPa were completed. Absorption of nitrogen resulted in no observable volume change, whereas absorption of carbon dioxide resulted in temperature independent swelling of up to 9.8%. The gas bubble’s structure and behavior during its ascend through the liquid was optically tracked in situ. Combining these two data sets with the absorption kinetics forms the basis to determine the measuring system independent mass transfer coefficients, which are applicable in other laboratory scale and industrial processes.
doi_str_mv 10.1063/1.5011125
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmed_primary_29716350</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2033377968</sourcerecordid><originalsourceid>FETCH-LOGICAL-c352t-31ba0d2d4a732888311493453f54b9d95f118477fc494dff11d455fd55a843e53</originalsourceid><addsrcrecordid>eNp9kM1qGzEUhUVoaByni7xA0bItmVR3JM3PsoQ0DQSySdeDrB9bZUaydTUxfoa-dMfYSReB3M3lwnfOuRxCLoFdA6v4d7iWDABKeUJmwJq2qKuSfyAzxrgoqlo0Z-Qc8Q-bRgJ8JGdlW0PFJZuRv7dhpYK2gw2ZRkeXST37webkNXUxaWuo6-OW5lWK43JFcYfZDjRHamy2afDBUoxpnX0MVxS3tu99WF5RFQwdFCLNSQV0NlG9UknpSeMxe437sN5vRm_2-sUUjxfk1Kke7afjnpPfP2-fbn4VD4939zc_HgrNZZkLDgvFTGmEqnnZNA0HEC0XkjspFq1ppQNoRF07LVph3HQZIaUzUqpGcCv5nHw5-K5T3IwWczd41NPnKtg4Ylcyznldt1UzoV8PqE4RMVnXrZMfVNp1wLp99x10x-4n9vPRdlwM1rySL2VPwLcDgNpntW_slXmO6b9TtzbuPfht9D-fmZya</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2033377968</pqid></control><display><type>article</type><title>Enhancement of gravimetric forced flow through system to determine sorption, swelling, and mass transfer characteristics of liquid sorbents</title><source>AIP Journals Complete</source><source>Alma/SFX Local Collection</source><creator>Dresp, G. ; Petermann, M. ; Fieback, T. M.</creator><creatorcontrib>Dresp, G. ; Petermann, M. ; Fieback, T. M.</creatorcontrib><description>An existing apparatus for forced flow through of liquid sorbents has been enhanced with an optically accessible system including a transparent crucible, high pressure viewing cell, and camera. With this optical system, the active surface area between gas and liquid can be determined in situ for the first time under industrial process conditions while maintaining the accuracy of a magnetic suspension balance. Additionally, occurring swelling and the resulting buoyancy changes can now be corrected, further improving the quality of the data. Validation measurements focusing on the sorption isotherms, swelling, and bubble geometry of 1-butyl-3-methylimidazolium tetrafluoroborate with nitrogen at 303 K and up to 17 MPa, as well as with carbon dioxide at 303 K, 323 K, and 373 K at up to 3.5 MPa were completed. Absorption of nitrogen resulted in no observable volume change, whereas absorption of carbon dioxide resulted in temperature independent swelling of up to 9.8%. The gas bubble’s structure and behavior during its ascend through the liquid was optically tracked in situ. Combining these two data sets with the absorption kinetics forms the basis to determine the measuring system independent mass transfer coefficients, which are applicable in other laboratory scale and industrial processes.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.5011125</identifier><identifier>PMID: 29716350</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>United States</publisher><ispartof>Review of scientific instruments, 2018-04, Vol.89 (4), p.045102-045102</ispartof><rights>Author(s)</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c352t-31ba0d2d4a732888311493453f54b9d95f118477fc494dff11d455fd55a843e53</cites><orcidid>0000-0003-4921-1426 ; 0000-0001-7844-9674 ; 0000000349211426 ; 0000000178449674</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.5011125$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,780,784,794,4512,27924,27925,76384</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29716350$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Dresp, G.</creatorcontrib><creatorcontrib>Petermann, M.</creatorcontrib><creatorcontrib>Fieback, T. M.</creatorcontrib><title>Enhancement of gravimetric forced flow through system to determine sorption, swelling, and mass transfer characteristics of liquid sorbents</title><title>Review of scientific instruments</title><addtitle>Rev Sci Instrum</addtitle><description>An existing apparatus for forced flow through of liquid sorbents has been enhanced with an optically accessible system including a transparent crucible, high pressure viewing cell, and camera. With this optical system, the active surface area between gas and liquid can be determined in situ for the first time under industrial process conditions while maintaining the accuracy of a magnetic suspension balance. Additionally, occurring swelling and the resulting buoyancy changes can now be corrected, further improving the quality of the data. Validation measurements focusing on the sorption isotherms, swelling, and bubble geometry of 1-butyl-3-methylimidazolium tetrafluoroborate with nitrogen at 303 K and up to 17 MPa, as well as with carbon dioxide at 303 K, 323 K, and 373 K at up to 3.5 MPa were completed. Absorption of nitrogen resulted in no observable volume change, whereas absorption of carbon dioxide resulted in temperature independent swelling of up to 9.8%. The gas bubble’s structure and behavior during its ascend through the liquid was optically tracked in situ. Combining these two data sets with the absorption kinetics forms the basis to determine the measuring system independent mass transfer coefficients, which are applicable in other laboratory scale and industrial processes.</description><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp9kM1qGzEUhUVoaByni7xA0bItmVR3JM3PsoQ0DQSySdeDrB9bZUaydTUxfoa-dMfYSReB3M3lwnfOuRxCLoFdA6v4d7iWDABKeUJmwJq2qKuSfyAzxrgoqlo0Z-Qc8Q-bRgJ8JGdlW0PFJZuRv7dhpYK2gw2ZRkeXST37webkNXUxaWuo6-OW5lWK43JFcYfZDjRHamy2afDBUoxpnX0MVxS3tu99WF5RFQwdFCLNSQV0NlG9UknpSeMxe437sN5vRm_2-sUUjxfk1Kke7afjnpPfP2-fbn4VD4939zc_HgrNZZkLDgvFTGmEqnnZNA0HEC0XkjspFq1ppQNoRF07LVph3HQZIaUzUqpGcCv5nHw5-K5T3IwWczd41NPnKtg4Ylcyznldt1UzoV8PqE4RMVnXrZMfVNp1wLp99x10x-4n9vPRdlwM1rySL2VPwLcDgNpntW_slXmO6b9TtzbuPfht9D-fmZya</recordid><startdate>20180401</startdate><enddate>20180401</enddate><creator>Dresp, G.</creator><creator>Petermann, M.</creator><creator>Fieback, T. M.</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-4921-1426</orcidid><orcidid>https://orcid.org/0000-0001-7844-9674</orcidid><orcidid>https://orcid.org/0000000349211426</orcidid><orcidid>https://orcid.org/0000000178449674</orcidid></search><sort><creationdate>20180401</creationdate><title>Enhancement of gravimetric forced flow through system to determine sorption, swelling, and mass transfer characteristics of liquid sorbents</title><author>Dresp, G. ; Petermann, M. ; Fieback, T. M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c352t-31ba0d2d4a732888311493453f54b9d95f118477fc494dff11d455fd55a843e53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Dresp, G.</creatorcontrib><creatorcontrib>Petermann, M.</creatorcontrib><creatorcontrib>Fieback, T. M.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Dresp, G.</au><au>Petermann, M.</au><au>Fieback, T. M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Enhancement of gravimetric forced flow through system to determine sorption, swelling, and mass transfer characteristics of liquid sorbents</atitle><jtitle>Review of scientific instruments</jtitle><addtitle>Rev Sci Instrum</addtitle><date>2018-04-01</date><risdate>2018</risdate><volume>89</volume><issue>4</issue><spage>045102</spage><epage>045102</epage><pages>045102-045102</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>An existing apparatus for forced flow through of liquid sorbents has been enhanced with an optically accessible system including a transparent crucible, high pressure viewing cell, and camera. With this optical system, the active surface area between gas and liquid can be determined in situ for the first time under industrial process conditions while maintaining the accuracy of a magnetic suspension balance. Additionally, occurring swelling and the resulting buoyancy changes can now be corrected, further improving the quality of the data. Validation measurements focusing on the sorption isotherms, swelling, and bubble geometry of 1-butyl-3-methylimidazolium tetrafluoroborate with nitrogen at 303 K and up to 17 MPa, as well as with carbon dioxide at 303 K, 323 K, and 373 K at up to 3.5 MPa were completed. Absorption of nitrogen resulted in no observable volume change, whereas absorption of carbon dioxide resulted in temperature independent swelling of up to 9.8%. The gas bubble’s structure and behavior during its ascend through the liquid was optically tracked in situ. Combining these two data sets with the absorption kinetics forms the basis to determine the measuring system independent mass transfer coefficients, which are applicable in other laboratory scale and industrial processes.</abstract><cop>United States</cop><pmid>29716350</pmid><doi>10.1063/1.5011125</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0003-4921-1426</orcidid><orcidid>https://orcid.org/0000-0001-7844-9674</orcidid><orcidid>https://orcid.org/0000000349211426</orcidid><orcidid>https://orcid.org/0000000178449674</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0034-6748
ispartof Review of scientific instruments, 2018-04, Vol.89 (4), p.045102-045102
issn 0034-6748
1089-7623
language eng
recordid cdi_pubmed_primary_29716350
source AIP Journals Complete; Alma/SFX Local Collection
title Enhancement of gravimetric forced flow through system to determine sorption, swelling, and mass transfer characteristics of liquid sorbents
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T22%3A05%3A45IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Enhancement%20of%20gravimetric%20forced%20flow%20through%20system%20to%20determine%20sorption,%20swelling,%20and%20mass%20transfer%20characteristics%20of%20liquid%20sorbents&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Dresp,%20G.&rft.date=2018-04-01&rft.volume=89&rft.issue=4&rft.spage=045102&rft.epage=045102&rft.pages=045102-045102&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.5011125&rft_dat=%3Cproquest_pubme%3E2033377968%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2033377968&rft_id=info:pmid/29716350&rfr_iscdi=true