A fully integrated microfluidic platform for highly sensitive analysis of immunochemical parameters
We present a novel fully integrated centrifugal microfluidic platform for highly sensitive immunoassays in point-of-care settings. The platform consists of a disposable cartridge containing structures for assay processing, a porous membrane and all dried reagents required for the analysis. Additiona...
Gespeichert in:
Veröffentlicht in: | Analyst (London) 2017-11, Vol.142 (22), p.426-4214 |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 4214 |
---|---|
container_issue | 22 |
container_start_page | 426 |
container_title | Analyst (London) |
container_volume | 142 |
creator | Lutz, Sascha Lopez-Calle, Eloisa Espindola, Pamela Boehm, Christoph Brueckner, Thorsten Spinke, Juergen Marcinowski, Moritz Keller, Thomas Tgetgel, Armin Herbert, Nicolas Fischer, Thomas Beiersdorf, Erik |
description | We present a novel fully integrated centrifugal microfluidic platform for highly sensitive immunoassays in point-of-care settings. The platform consists of a disposable cartridge containing structures for assay processing, a porous membrane and all dried reagents required for the analysis. Additionally, a blister containing a washing buffer is connected to a new aliquoting structure enabling the serial aliquoting of washing buffer for repetitive bound-free separation steps. The proof-of-concept for two immunoassays is shown in the cartridge with each requiring only 30 μL of whole blood or plasma as the sample material. The detection of the cardiac marker Troponin T with a functional sensitivity of 7.55 ng L
−1
(cv = 10%) within 11 minutes is shown based on samples from ten donors which were measured with six breadboard instruments to prove the platform capability for highly sensitive measurements at diagnostic relevant concentrations. Furthermore an assay for the cardiac marker NT-proBNP (five donors, six instruments) with a time-to-result of 12 minutes demonstrates that high-titer analytes (43 to 16.566 ng L
−1
) can be measured as well. A method comparison of our platform with a state-of-the-art laboratory analyzer proves an excellent correlation of the measured analyte concentrations. All results are obtained from injection moulded cartridges and all components of the platform are compatible for mass production.
A fully integrated cartridge for highly sensitive immunochemical analysis of cardiac markers with new microfluidic functionalities is presented. |
doi_str_mv | 10.1039/c7an00547d |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmed_primary_29043325</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2010821828</sourcerecordid><originalsourceid>FETCH-LOGICAL-c337t-1596e7eb7605dc30edc5ca5a44e1639dd9e4549206202dcfa1767a5fa19d70ca3</originalsourceid><addsrcrecordid>eNpdkUtLAzEQgIMotlYv3pWAFxFW89hsdo-lPqHoRc9Lmsy2KdmHya7Qf2-0VcHLDMN8MzDfIHRKyTUlvLjRUjWEiFSaPTSmPEsTIVi-j8aEEJ6wTKQjdBTCOpaUCHKIRqwgKedMjJGe4mpwboNt08PSqx4Mrq32beUGa6zGnVN91foax4BXdrmKbIAm2N5-AFaNcptgA24rbOt6aFq9gjivHO6UVzX04MMxOqiUC3CyyxP0dn_3OntM5i8PT7PpPNGcyz6hoshAwkJmRBjNCRgttBIqTYFmvDCmgFSkBSMZI8zoSlGZSSViLowkWvEJutzu7Xz7PkDoy9oGDc6pBtohlLQQLIqRVEb04h-6bgcfjwkli5JyRnOWR-pqS0UfIXioys7bWvlNSUn5pb6cyenzt_rbCJ_vVg6LGswv-uM6AmdbwAf92_37Hf8EnrqJTw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2010821828</pqid></control><display><type>article</type><title>A fully integrated microfluidic platform for highly sensitive analysis of immunochemical parameters</title><source>MEDLINE</source><source>Royal Society of Chemistry Journals Archive (1841-2007)</source><source>Royal Society Of Chemistry Journals 2008-</source><source>Alma/SFX Local Collection</source><creator>Lutz, Sascha ; Lopez-Calle, Eloisa ; Espindola, Pamela ; Boehm, Christoph ; Brueckner, Thorsten ; Spinke, Juergen ; Marcinowski, Moritz ; Keller, Thomas ; Tgetgel, Armin ; Herbert, Nicolas ; Fischer, Thomas ; Beiersdorf, Erik</creator><creatorcontrib>Lutz, Sascha ; Lopez-Calle, Eloisa ; Espindola, Pamela ; Boehm, Christoph ; Brueckner, Thorsten ; Spinke, Juergen ; Marcinowski, Moritz ; Keller, Thomas ; Tgetgel, Armin ; Herbert, Nicolas ; Fischer, Thomas ; Beiersdorf, Erik</creatorcontrib><description>We present a novel fully integrated centrifugal microfluidic platform for highly sensitive immunoassays in point-of-care settings. The platform consists of a disposable cartridge containing structures for assay processing, a porous membrane and all dried reagents required for the analysis. Additionally, a blister containing a washing buffer is connected to a new aliquoting structure enabling the serial aliquoting of washing buffer for repetitive bound-free separation steps. The proof-of-concept for two immunoassays is shown in the cartridge with each requiring only 30 μL of whole blood or plasma as the sample material. The detection of the cardiac marker Troponin T with a functional sensitivity of 7.55 ng L
−1
(cv = 10%) within 11 minutes is shown based on samples from ten donors which were measured with six breadboard instruments to prove the platform capability for highly sensitive measurements at diagnostic relevant concentrations. Furthermore an assay for the cardiac marker NT-proBNP (five donors, six instruments) with a time-to-result of 12 minutes demonstrates that high-titer analytes (43 to 16.566 ng L
−1
) can be measured as well. A method comparison of our platform with a state-of-the-art laboratory analyzer proves an excellent correlation of the measured analyte concentrations. All results are obtained from injection moulded cartridges and all components of the platform are compatible for mass production.
A fully integrated cartridge for highly sensitive immunochemical analysis of cardiac markers with new microfluidic functionalities is presented.</description><identifier>ISSN: 0003-2654</identifier><identifier>EISSN: 1364-5528</identifier><identifier>DOI: 10.1039/c7an00547d</identifier><identifier>PMID: 29043325</identifier><language>eng</language><publisher>England: Royal Society of Chemistry</publisher><subject>Analytical chemistry ; Biomarkers - analysis ; Blistering ; Buffers ; Cartridges ; Correlation analysis ; Diagnostic systems ; Humans ; Immunoassay ; Injection molding ; Mass production ; Microfluidic Analytical Techniques ; Natriuretic Peptide, Brain - analysis ; Parameter sensitivity ; Peptide Fragments - analysis ; Point-of-Care Systems ; Reagents ; Troponin T - analysis ; Washing</subject><ispartof>Analyst (London), 2017-11, Vol.142 (22), p.426-4214</ispartof><rights>Copyright Royal Society of Chemistry 2017</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c337t-1596e7eb7605dc30edc5ca5a44e1639dd9e4549206202dcfa1767a5fa19d70ca3</citedby><cites>FETCH-LOGICAL-c337t-1596e7eb7605dc30edc5ca5a44e1639dd9e4549206202dcfa1767a5fa19d70ca3</cites><orcidid>0000-0002-1401-3625</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,2831,2832,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29043325$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lutz, Sascha</creatorcontrib><creatorcontrib>Lopez-Calle, Eloisa</creatorcontrib><creatorcontrib>Espindola, Pamela</creatorcontrib><creatorcontrib>Boehm, Christoph</creatorcontrib><creatorcontrib>Brueckner, Thorsten</creatorcontrib><creatorcontrib>Spinke, Juergen</creatorcontrib><creatorcontrib>Marcinowski, Moritz</creatorcontrib><creatorcontrib>Keller, Thomas</creatorcontrib><creatorcontrib>Tgetgel, Armin</creatorcontrib><creatorcontrib>Herbert, Nicolas</creatorcontrib><creatorcontrib>Fischer, Thomas</creatorcontrib><creatorcontrib>Beiersdorf, Erik</creatorcontrib><title>A fully integrated microfluidic platform for highly sensitive analysis of immunochemical parameters</title><title>Analyst (London)</title><addtitle>Analyst</addtitle><description>We present a novel fully integrated centrifugal microfluidic platform for highly sensitive immunoassays in point-of-care settings. The platform consists of a disposable cartridge containing structures for assay processing, a porous membrane and all dried reagents required for the analysis. Additionally, a blister containing a washing buffer is connected to a new aliquoting structure enabling the serial aliquoting of washing buffer for repetitive bound-free separation steps. The proof-of-concept for two immunoassays is shown in the cartridge with each requiring only 30 μL of whole blood or plasma as the sample material. The detection of the cardiac marker Troponin T with a functional sensitivity of 7.55 ng L
−1
(cv = 10%) within 11 minutes is shown based on samples from ten donors which were measured with six breadboard instruments to prove the platform capability for highly sensitive measurements at diagnostic relevant concentrations. Furthermore an assay for the cardiac marker NT-proBNP (five donors, six instruments) with a time-to-result of 12 minutes demonstrates that high-titer analytes (43 to 16.566 ng L
−1
) can be measured as well. A method comparison of our platform with a state-of-the-art laboratory analyzer proves an excellent correlation of the measured analyte concentrations. All results are obtained from injection moulded cartridges and all components of the platform are compatible for mass production.
A fully integrated cartridge for highly sensitive immunochemical analysis of cardiac markers with new microfluidic functionalities is presented.</description><subject>Analytical chemistry</subject><subject>Biomarkers - analysis</subject><subject>Blistering</subject><subject>Buffers</subject><subject>Cartridges</subject><subject>Correlation analysis</subject><subject>Diagnostic systems</subject><subject>Humans</subject><subject>Immunoassay</subject><subject>Injection molding</subject><subject>Mass production</subject><subject>Microfluidic Analytical Techniques</subject><subject>Natriuretic Peptide, Brain - analysis</subject><subject>Parameter sensitivity</subject><subject>Peptide Fragments - analysis</subject><subject>Point-of-Care Systems</subject><subject>Reagents</subject><subject>Troponin T - analysis</subject><subject>Washing</subject><issn>0003-2654</issn><issn>1364-5528</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpdkUtLAzEQgIMotlYv3pWAFxFW89hsdo-lPqHoRc9Lmsy2KdmHya7Qf2-0VcHLDMN8MzDfIHRKyTUlvLjRUjWEiFSaPTSmPEsTIVi-j8aEEJ6wTKQjdBTCOpaUCHKIRqwgKedMjJGe4mpwboNt08PSqx4Mrq32beUGa6zGnVN91foax4BXdrmKbIAm2N5-AFaNcptgA24rbOt6aFq9gjivHO6UVzX04MMxOqiUC3CyyxP0dn_3OntM5i8PT7PpPNGcyz6hoshAwkJmRBjNCRgttBIqTYFmvDCmgFSkBSMZI8zoSlGZSSViLowkWvEJutzu7Xz7PkDoy9oGDc6pBtohlLQQLIqRVEb04h-6bgcfjwkli5JyRnOWR-pqS0UfIXioys7bWvlNSUn5pb6cyenzt_rbCJ_vVg6LGswv-uM6AmdbwAf92_37Hf8EnrqJTw</recordid><startdate>20171106</startdate><enddate>20171106</enddate><creator>Lutz, Sascha</creator><creator>Lopez-Calle, Eloisa</creator><creator>Espindola, Pamela</creator><creator>Boehm, Christoph</creator><creator>Brueckner, Thorsten</creator><creator>Spinke, Juergen</creator><creator>Marcinowski, Moritz</creator><creator>Keller, Thomas</creator><creator>Tgetgel, Armin</creator><creator>Herbert, Nicolas</creator><creator>Fischer, Thomas</creator><creator>Beiersdorf, Erik</creator><general>Royal Society of Chemistry</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-1401-3625</orcidid></search><sort><creationdate>20171106</creationdate><title>A fully integrated microfluidic platform for highly sensitive analysis of immunochemical parameters</title><author>Lutz, Sascha ; Lopez-Calle, Eloisa ; Espindola, Pamela ; Boehm, Christoph ; Brueckner, Thorsten ; Spinke, Juergen ; Marcinowski, Moritz ; Keller, Thomas ; Tgetgel, Armin ; Herbert, Nicolas ; Fischer, Thomas ; Beiersdorf, Erik</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c337t-1596e7eb7605dc30edc5ca5a44e1639dd9e4549206202dcfa1767a5fa19d70ca3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Analytical chemistry</topic><topic>Biomarkers - analysis</topic><topic>Blistering</topic><topic>Buffers</topic><topic>Cartridges</topic><topic>Correlation analysis</topic><topic>Diagnostic systems</topic><topic>Humans</topic><topic>Immunoassay</topic><topic>Injection molding</topic><topic>Mass production</topic><topic>Microfluidic Analytical Techniques</topic><topic>Natriuretic Peptide, Brain - analysis</topic><topic>Parameter sensitivity</topic><topic>Peptide Fragments - analysis</topic><topic>Point-of-Care Systems</topic><topic>Reagents</topic><topic>Troponin T - analysis</topic><topic>Washing</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lutz, Sascha</creatorcontrib><creatorcontrib>Lopez-Calle, Eloisa</creatorcontrib><creatorcontrib>Espindola, Pamela</creatorcontrib><creatorcontrib>Boehm, Christoph</creatorcontrib><creatorcontrib>Brueckner, Thorsten</creatorcontrib><creatorcontrib>Spinke, Juergen</creatorcontrib><creatorcontrib>Marcinowski, Moritz</creatorcontrib><creatorcontrib>Keller, Thomas</creatorcontrib><creatorcontrib>Tgetgel, Armin</creatorcontrib><creatorcontrib>Herbert, Nicolas</creatorcontrib><creatorcontrib>Fischer, Thomas</creatorcontrib><creatorcontrib>Beiersdorf, Erik</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Analyst (London)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lutz, Sascha</au><au>Lopez-Calle, Eloisa</au><au>Espindola, Pamela</au><au>Boehm, Christoph</au><au>Brueckner, Thorsten</au><au>Spinke, Juergen</au><au>Marcinowski, Moritz</au><au>Keller, Thomas</au><au>Tgetgel, Armin</au><au>Herbert, Nicolas</au><au>Fischer, Thomas</au><au>Beiersdorf, Erik</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A fully integrated microfluidic platform for highly sensitive analysis of immunochemical parameters</atitle><jtitle>Analyst (London)</jtitle><addtitle>Analyst</addtitle><date>2017-11-06</date><risdate>2017</risdate><volume>142</volume><issue>22</issue><spage>426</spage><epage>4214</epage><pages>426-4214</pages><issn>0003-2654</issn><eissn>1364-5528</eissn><abstract>We present a novel fully integrated centrifugal microfluidic platform for highly sensitive immunoassays in point-of-care settings. The platform consists of a disposable cartridge containing structures for assay processing, a porous membrane and all dried reagents required for the analysis. Additionally, a blister containing a washing buffer is connected to a new aliquoting structure enabling the serial aliquoting of washing buffer for repetitive bound-free separation steps. The proof-of-concept for two immunoassays is shown in the cartridge with each requiring only 30 μL of whole blood or plasma as the sample material. The detection of the cardiac marker Troponin T with a functional sensitivity of 7.55 ng L
−1
(cv = 10%) within 11 minutes is shown based on samples from ten donors which were measured with six breadboard instruments to prove the platform capability for highly sensitive measurements at diagnostic relevant concentrations. Furthermore an assay for the cardiac marker NT-proBNP (five donors, six instruments) with a time-to-result of 12 minutes demonstrates that high-titer analytes (43 to 16.566 ng L
−1
) can be measured as well. A method comparison of our platform with a state-of-the-art laboratory analyzer proves an excellent correlation of the measured analyte concentrations. All results are obtained from injection moulded cartridges and all components of the platform are compatible for mass production.
A fully integrated cartridge for highly sensitive immunochemical analysis of cardiac markers with new microfluidic functionalities is presented.</abstract><cop>England</cop><pub>Royal Society of Chemistry</pub><pmid>29043325</pmid><doi>10.1039/c7an00547d</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0002-1401-3625</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2654 |
ispartof | Analyst (London), 2017-11, Vol.142 (22), p.426-4214 |
issn | 0003-2654 1364-5528 |
language | eng |
recordid | cdi_pubmed_primary_29043325 |
source | MEDLINE; Royal Society of Chemistry Journals Archive (1841-2007); Royal Society Of Chemistry Journals 2008-; Alma/SFX Local Collection |
subjects | Analytical chemistry Biomarkers - analysis Blistering Buffers Cartridges Correlation analysis Diagnostic systems Humans Immunoassay Injection molding Mass production Microfluidic Analytical Techniques Natriuretic Peptide, Brain - analysis Parameter sensitivity Peptide Fragments - analysis Point-of-Care Systems Reagents Troponin T - analysis Washing |
title | A fully integrated microfluidic platform for highly sensitive analysis of immunochemical parameters |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T02%3A53%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20fully%20integrated%20microfluidic%20platform%20for%20highly%20sensitive%20analysis%20of%20immunochemical%20parameters&rft.jtitle=Analyst%20(London)&rft.au=Lutz,%20Sascha&rft.date=2017-11-06&rft.volume=142&rft.issue=22&rft.spage=426&rft.epage=4214&rft.pages=426-4214&rft.issn=0003-2654&rft.eissn=1364-5528&rft_id=info:doi/10.1039/c7an00547d&rft_dat=%3Cproquest_pubme%3E2010821828%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2010821828&rft_id=info:pmid/29043325&rfr_iscdi=true |