A fully integrated microfluidic platform for highly sensitive analysis of immunochemical parameters

We present a novel fully integrated centrifugal microfluidic platform for highly sensitive immunoassays in point-of-care settings. The platform consists of a disposable cartridge containing structures for assay processing, a porous membrane and all dried reagents required for the analysis. Additiona...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analyst (London) 2017-11, Vol.142 (22), p.426-4214
Hauptverfasser: Lutz, Sascha, Lopez-Calle, Eloisa, Espindola, Pamela, Boehm, Christoph, Brueckner, Thorsten, Spinke, Juergen, Marcinowski, Moritz, Keller, Thomas, Tgetgel, Armin, Herbert, Nicolas, Fischer, Thomas, Beiersdorf, Erik
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 4214
container_issue 22
container_start_page 426
container_title Analyst (London)
container_volume 142
creator Lutz, Sascha
Lopez-Calle, Eloisa
Espindola, Pamela
Boehm, Christoph
Brueckner, Thorsten
Spinke, Juergen
Marcinowski, Moritz
Keller, Thomas
Tgetgel, Armin
Herbert, Nicolas
Fischer, Thomas
Beiersdorf, Erik
description We present a novel fully integrated centrifugal microfluidic platform for highly sensitive immunoassays in point-of-care settings. The platform consists of a disposable cartridge containing structures for assay processing, a porous membrane and all dried reagents required for the analysis. Additionally, a blister containing a washing buffer is connected to a new aliquoting structure enabling the serial aliquoting of washing buffer for repetitive bound-free separation steps. The proof-of-concept for two immunoassays is shown in the cartridge with each requiring only 30 μL of whole blood or plasma as the sample material. The detection of the cardiac marker Troponin T with a functional sensitivity of 7.55 ng L −1 (cv = 10%) within 11 minutes is shown based on samples from ten donors which were measured with six breadboard instruments to prove the platform capability for highly sensitive measurements at diagnostic relevant concentrations. Furthermore an assay for the cardiac marker NT-proBNP (five donors, six instruments) with a time-to-result of 12 minutes demonstrates that high-titer analytes (43 to 16.566 ng L −1 ) can be measured as well. A method comparison of our platform with a state-of-the-art laboratory analyzer proves an excellent correlation of the measured analyte concentrations. All results are obtained from injection moulded cartridges and all components of the platform are compatible for mass production. A fully integrated cartridge for highly sensitive immunochemical analysis of cardiac markers with new microfluidic functionalities is presented.
doi_str_mv 10.1039/c7an00547d
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmed_primary_29043325</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2010821828</sourcerecordid><originalsourceid>FETCH-LOGICAL-c337t-1596e7eb7605dc30edc5ca5a44e1639dd9e4549206202dcfa1767a5fa19d70ca3</originalsourceid><addsrcrecordid>eNpdkUtLAzEQgIMotlYv3pWAFxFW89hsdo-lPqHoRc9Lmsy2KdmHya7Qf2-0VcHLDMN8MzDfIHRKyTUlvLjRUjWEiFSaPTSmPEsTIVi-j8aEEJ6wTKQjdBTCOpaUCHKIRqwgKedMjJGe4mpwboNt08PSqx4Mrq32beUGa6zGnVN91foax4BXdrmKbIAm2N5-AFaNcptgA24rbOt6aFq9gjivHO6UVzX04MMxOqiUC3CyyxP0dn_3OntM5i8PT7PpPNGcyz6hoshAwkJmRBjNCRgttBIqTYFmvDCmgFSkBSMZI8zoSlGZSSViLowkWvEJutzu7Xz7PkDoy9oGDc6pBtohlLQQLIqRVEb04h-6bgcfjwkli5JyRnOWR-pqS0UfIXioys7bWvlNSUn5pb6cyenzt_rbCJ_vVg6LGswv-uM6AmdbwAf92_37Hf8EnrqJTw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2010821828</pqid></control><display><type>article</type><title>A fully integrated microfluidic platform for highly sensitive analysis of immunochemical parameters</title><source>MEDLINE</source><source>Royal Society of Chemistry Journals Archive (1841-2007)</source><source>Royal Society Of Chemistry Journals 2008-</source><source>Alma/SFX Local Collection</source><creator>Lutz, Sascha ; Lopez-Calle, Eloisa ; Espindola, Pamela ; Boehm, Christoph ; Brueckner, Thorsten ; Spinke, Juergen ; Marcinowski, Moritz ; Keller, Thomas ; Tgetgel, Armin ; Herbert, Nicolas ; Fischer, Thomas ; Beiersdorf, Erik</creator><creatorcontrib>Lutz, Sascha ; Lopez-Calle, Eloisa ; Espindola, Pamela ; Boehm, Christoph ; Brueckner, Thorsten ; Spinke, Juergen ; Marcinowski, Moritz ; Keller, Thomas ; Tgetgel, Armin ; Herbert, Nicolas ; Fischer, Thomas ; Beiersdorf, Erik</creatorcontrib><description>We present a novel fully integrated centrifugal microfluidic platform for highly sensitive immunoassays in point-of-care settings. The platform consists of a disposable cartridge containing structures for assay processing, a porous membrane and all dried reagents required for the analysis. Additionally, a blister containing a washing buffer is connected to a new aliquoting structure enabling the serial aliquoting of washing buffer for repetitive bound-free separation steps. The proof-of-concept for two immunoassays is shown in the cartridge with each requiring only 30 μL of whole blood or plasma as the sample material. The detection of the cardiac marker Troponin T with a functional sensitivity of 7.55 ng L −1 (cv = 10%) within 11 minutes is shown based on samples from ten donors which were measured with six breadboard instruments to prove the platform capability for highly sensitive measurements at diagnostic relevant concentrations. Furthermore an assay for the cardiac marker NT-proBNP (five donors, six instruments) with a time-to-result of 12 minutes demonstrates that high-titer analytes (43 to 16.566 ng L −1 ) can be measured as well. A method comparison of our platform with a state-of-the-art laboratory analyzer proves an excellent correlation of the measured analyte concentrations. All results are obtained from injection moulded cartridges and all components of the platform are compatible for mass production. A fully integrated cartridge for highly sensitive immunochemical analysis of cardiac markers with new microfluidic functionalities is presented.</description><identifier>ISSN: 0003-2654</identifier><identifier>EISSN: 1364-5528</identifier><identifier>DOI: 10.1039/c7an00547d</identifier><identifier>PMID: 29043325</identifier><language>eng</language><publisher>England: Royal Society of Chemistry</publisher><subject>Analytical chemistry ; Biomarkers - analysis ; Blistering ; Buffers ; Cartridges ; Correlation analysis ; Diagnostic systems ; Humans ; Immunoassay ; Injection molding ; Mass production ; Microfluidic Analytical Techniques ; Natriuretic Peptide, Brain - analysis ; Parameter sensitivity ; Peptide Fragments - analysis ; Point-of-Care Systems ; Reagents ; Troponin T - analysis ; Washing</subject><ispartof>Analyst (London), 2017-11, Vol.142 (22), p.426-4214</ispartof><rights>Copyright Royal Society of Chemistry 2017</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c337t-1596e7eb7605dc30edc5ca5a44e1639dd9e4549206202dcfa1767a5fa19d70ca3</citedby><cites>FETCH-LOGICAL-c337t-1596e7eb7605dc30edc5ca5a44e1639dd9e4549206202dcfa1767a5fa19d70ca3</cites><orcidid>0000-0002-1401-3625</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,2831,2832,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29043325$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lutz, Sascha</creatorcontrib><creatorcontrib>Lopez-Calle, Eloisa</creatorcontrib><creatorcontrib>Espindola, Pamela</creatorcontrib><creatorcontrib>Boehm, Christoph</creatorcontrib><creatorcontrib>Brueckner, Thorsten</creatorcontrib><creatorcontrib>Spinke, Juergen</creatorcontrib><creatorcontrib>Marcinowski, Moritz</creatorcontrib><creatorcontrib>Keller, Thomas</creatorcontrib><creatorcontrib>Tgetgel, Armin</creatorcontrib><creatorcontrib>Herbert, Nicolas</creatorcontrib><creatorcontrib>Fischer, Thomas</creatorcontrib><creatorcontrib>Beiersdorf, Erik</creatorcontrib><title>A fully integrated microfluidic platform for highly sensitive analysis of immunochemical parameters</title><title>Analyst (London)</title><addtitle>Analyst</addtitle><description>We present a novel fully integrated centrifugal microfluidic platform for highly sensitive immunoassays in point-of-care settings. The platform consists of a disposable cartridge containing structures for assay processing, a porous membrane and all dried reagents required for the analysis. Additionally, a blister containing a washing buffer is connected to a new aliquoting structure enabling the serial aliquoting of washing buffer for repetitive bound-free separation steps. The proof-of-concept for two immunoassays is shown in the cartridge with each requiring only 30 μL of whole blood or plasma as the sample material. The detection of the cardiac marker Troponin T with a functional sensitivity of 7.55 ng L −1 (cv = 10%) within 11 minutes is shown based on samples from ten donors which were measured with six breadboard instruments to prove the platform capability for highly sensitive measurements at diagnostic relevant concentrations. Furthermore an assay for the cardiac marker NT-proBNP (five donors, six instruments) with a time-to-result of 12 minutes demonstrates that high-titer analytes (43 to 16.566 ng L −1 ) can be measured as well. A method comparison of our platform with a state-of-the-art laboratory analyzer proves an excellent correlation of the measured analyte concentrations. All results are obtained from injection moulded cartridges and all components of the platform are compatible for mass production. A fully integrated cartridge for highly sensitive immunochemical analysis of cardiac markers with new microfluidic functionalities is presented.</description><subject>Analytical chemistry</subject><subject>Biomarkers - analysis</subject><subject>Blistering</subject><subject>Buffers</subject><subject>Cartridges</subject><subject>Correlation analysis</subject><subject>Diagnostic systems</subject><subject>Humans</subject><subject>Immunoassay</subject><subject>Injection molding</subject><subject>Mass production</subject><subject>Microfluidic Analytical Techniques</subject><subject>Natriuretic Peptide, Brain - analysis</subject><subject>Parameter sensitivity</subject><subject>Peptide Fragments - analysis</subject><subject>Point-of-Care Systems</subject><subject>Reagents</subject><subject>Troponin T - analysis</subject><subject>Washing</subject><issn>0003-2654</issn><issn>1364-5528</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpdkUtLAzEQgIMotlYv3pWAFxFW89hsdo-lPqHoRc9Lmsy2KdmHya7Qf2-0VcHLDMN8MzDfIHRKyTUlvLjRUjWEiFSaPTSmPEsTIVi-j8aEEJ6wTKQjdBTCOpaUCHKIRqwgKedMjJGe4mpwboNt08PSqx4Mrq32beUGa6zGnVN91foax4BXdrmKbIAm2N5-AFaNcptgA24rbOt6aFq9gjivHO6UVzX04MMxOqiUC3CyyxP0dn_3OntM5i8PT7PpPNGcyz6hoshAwkJmRBjNCRgttBIqTYFmvDCmgFSkBSMZI8zoSlGZSSViLowkWvEJutzu7Xz7PkDoy9oGDc6pBtohlLQQLIqRVEb04h-6bgcfjwkli5JyRnOWR-pqS0UfIXioys7bWvlNSUn5pb6cyenzt_rbCJ_vVg6LGswv-uM6AmdbwAf92_37Hf8EnrqJTw</recordid><startdate>20171106</startdate><enddate>20171106</enddate><creator>Lutz, Sascha</creator><creator>Lopez-Calle, Eloisa</creator><creator>Espindola, Pamela</creator><creator>Boehm, Christoph</creator><creator>Brueckner, Thorsten</creator><creator>Spinke, Juergen</creator><creator>Marcinowski, Moritz</creator><creator>Keller, Thomas</creator><creator>Tgetgel, Armin</creator><creator>Herbert, Nicolas</creator><creator>Fischer, Thomas</creator><creator>Beiersdorf, Erik</creator><general>Royal Society of Chemistry</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-1401-3625</orcidid></search><sort><creationdate>20171106</creationdate><title>A fully integrated microfluidic platform for highly sensitive analysis of immunochemical parameters</title><author>Lutz, Sascha ; Lopez-Calle, Eloisa ; Espindola, Pamela ; Boehm, Christoph ; Brueckner, Thorsten ; Spinke, Juergen ; Marcinowski, Moritz ; Keller, Thomas ; Tgetgel, Armin ; Herbert, Nicolas ; Fischer, Thomas ; Beiersdorf, Erik</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c337t-1596e7eb7605dc30edc5ca5a44e1639dd9e4549206202dcfa1767a5fa19d70ca3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Analytical chemistry</topic><topic>Biomarkers - analysis</topic><topic>Blistering</topic><topic>Buffers</topic><topic>Cartridges</topic><topic>Correlation analysis</topic><topic>Diagnostic systems</topic><topic>Humans</topic><topic>Immunoassay</topic><topic>Injection molding</topic><topic>Mass production</topic><topic>Microfluidic Analytical Techniques</topic><topic>Natriuretic Peptide, Brain - analysis</topic><topic>Parameter sensitivity</topic><topic>Peptide Fragments - analysis</topic><topic>Point-of-Care Systems</topic><topic>Reagents</topic><topic>Troponin T - analysis</topic><topic>Washing</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lutz, Sascha</creatorcontrib><creatorcontrib>Lopez-Calle, Eloisa</creatorcontrib><creatorcontrib>Espindola, Pamela</creatorcontrib><creatorcontrib>Boehm, Christoph</creatorcontrib><creatorcontrib>Brueckner, Thorsten</creatorcontrib><creatorcontrib>Spinke, Juergen</creatorcontrib><creatorcontrib>Marcinowski, Moritz</creatorcontrib><creatorcontrib>Keller, Thomas</creatorcontrib><creatorcontrib>Tgetgel, Armin</creatorcontrib><creatorcontrib>Herbert, Nicolas</creatorcontrib><creatorcontrib>Fischer, Thomas</creatorcontrib><creatorcontrib>Beiersdorf, Erik</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Analyst (London)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lutz, Sascha</au><au>Lopez-Calle, Eloisa</au><au>Espindola, Pamela</au><au>Boehm, Christoph</au><au>Brueckner, Thorsten</au><au>Spinke, Juergen</au><au>Marcinowski, Moritz</au><au>Keller, Thomas</au><au>Tgetgel, Armin</au><au>Herbert, Nicolas</au><au>Fischer, Thomas</au><au>Beiersdorf, Erik</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A fully integrated microfluidic platform for highly sensitive analysis of immunochemical parameters</atitle><jtitle>Analyst (London)</jtitle><addtitle>Analyst</addtitle><date>2017-11-06</date><risdate>2017</risdate><volume>142</volume><issue>22</issue><spage>426</spage><epage>4214</epage><pages>426-4214</pages><issn>0003-2654</issn><eissn>1364-5528</eissn><abstract>We present a novel fully integrated centrifugal microfluidic platform for highly sensitive immunoassays in point-of-care settings. The platform consists of a disposable cartridge containing structures for assay processing, a porous membrane and all dried reagents required for the analysis. Additionally, a blister containing a washing buffer is connected to a new aliquoting structure enabling the serial aliquoting of washing buffer for repetitive bound-free separation steps. The proof-of-concept for two immunoassays is shown in the cartridge with each requiring only 30 μL of whole blood or plasma as the sample material. The detection of the cardiac marker Troponin T with a functional sensitivity of 7.55 ng L −1 (cv = 10%) within 11 minutes is shown based on samples from ten donors which were measured with six breadboard instruments to prove the platform capability for highly sensitive measurements at diagnostic relevant concentrations. Furthermore an assay for the cardiac marker NT-proBNP (five donors, six instruments) with a time-to-result of 12 minutes demonstrates that high-titer analytes (43 to 16.566 ng L −1 ) can be measured as well. A method comparison of our platform with a state-of-the-art laboratory analyzer proves an excellent correlation of the measured analyte concentrations. All results are obtained from injection moulded cartridges and all components of the platform are compatible for mass production. A fully integrated cartridge for highly sensitive immunochemical analysis of cardiac markers with new microfluidic functionalities is presented.</abstract><cop>England</cop><pub>Royal Society of Chemistry</pub><pmid>29043325</pmid><doi>10.1039/c7an00547d</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0002-1401-3625</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0003-2654
ispartof Analyst (London), 2017-11, Vol.142 (22), p.426-4214
issn 0003-2654
1364-5528
language eng
recordid cdi_pubmed_primary_29043325
source MEDLINE; Royal Society of Chemistry Journals Archive (1841-2007); Royal Society Of Chemistry Journals 2008-; Alma/SFX Local Collection
subjects Analytical chemistry
Biomarkers - analysis
Blistering
Buffers
Cartridges
Correlation analysis
Diagnostic systems
Humans
Immunoassay
Injection molding
Mass production
Microfluidic Analytical Techniques
Natriuretic Peptide, Brain - analysis
Parameter sensitivity
Peptide Fragments - analysis
Point-of-Care Systems
Reagents
Troponin T - analysis
Washing
title A fully integrated microfluidic platform for highly sensitive analysis of immunochemical parameters
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T02%3A53%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20fully%20integrated%20microfluidic%20platform%20for%20highly%20sensitive%20analysis%20of%20immunochemical%20parameters&rft.jtitle=Analyst%20(London)&rft.au=Lutz,%20Sascha&rft.date=2017-11-06&rft.volume=142&rft.issue=22&rft.spage=426&rft.epage=4214&rft.pages=426-4214&rft.issn=0003-2654&rft.eissn=1364-5528&rft_id=info:doi/10.1039/c7an00547d&rft_dat=%3Cproquest_pubme%3E2010821828%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2010821828&rft_id=info:pmid/29043325&rfr_iscdi=true