SU‐E‐T‐90: Investigation of Different Bleaching Wavelengths on the Absorbed‐Dose Sensitivity of NanoDot OSLDs Exposed to 6 MV X‐Ray Beams

Purpose: To determine the effect of different bleaching wavelengths on the luminescence response of Al2O3:C optically stimulated luminescence detectors (OSLDs) exposed to accumulated doses of 6 MV photon beams. Methods: OSLDs of the nanoDot type were used and readout with a microStar InLight reader....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical Physics 2012-06, Vol.39 (6), p.3723-3723
Hauptverfasser: Omotayo, A, Cygler, J, Sawakuchi, G
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3723
container_issue 6
container_start_page 3723
container_title Medical Physics
container_volume 39
creator Omotayo, A
Cygler, J
Sawakuchi, G
description Purpose: To determine the effect of different bleaching wavelengths on the luminescence response of Al2O3:C optically stimulated luminescence detectors (OSLDs) exposed to accumulated doses of 6 MV photon beams. Methods: OSLDs of the nanoDot type were used and readout with a microStar InLight reader. To determine the effect of different bleaching wavelengths on the luminescence response of nanoDot OSLDs, we optically reset (bleached) the OSLDs with 26 W fluorescent lamps in two modes: (i) directly under the lamps for 10, 120 and 600 min; and (ii) with a long pass filter for 55, 600 and 2400 min. The long pass filter blocks wavelengths below 495 nm, hence the longer bleaching duration to attain equivalent OSL signals as bleaching directly under the lamps. Changes in the sensitivity of the nanoDot OSLDs were determined for an irradiation‐readout‐bleaching‐readout cycle, after irradiations with 1 and 10 Gy dose fractions. Results: The nanoDot OSLDs presented a linear response to dose up to 2 Gy and supra‐linear response afterwards. They produced different OSL signal loss and fading behaviors for doses of 1 and 10 Gy. OSLDs bleached for 120 min and 600 min without and with the filter in 1 Gy fractions, did not exhibit any significant change in sensitivity over an accumulated dose of 7 Gy. The OSLDs exposed with 10 Gy fractions exhibited a small under‐response when bleached with filter, and an over‐response when bleached directly without filter. Conclusions: The nanoDot OSLDs may be reused without a significant sensitivity change for accumulated doses below 7 Gy. However, for accumulated doses beyond 10 Gy, nanoDot OSLDs show significant sensitivity change and hence, need to be recalibrated for reuse. We also concluded that the light spectrum used to reset the OSLDs has an influence on the sensitivity of the detectors. Natural Sciences and Engineering Research Council of Canada
doi_str_mv 10.1118/1.4735147
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmed_primary_28517131</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1900126041</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2337-dce7f0b00e1cee6a1b0970005032e614ddbc3e1ab500699e676015edc813f5fa3</originalsourceid><addsrcrecordid>eNp9kctOGzEUhq2qqAToghdAXpZKA-eM55LpDki4SAGqBkp3I4_nTGI0GadjJ5Adj4DEG_IkGJKyK4sje_H5s_7zM7aNsIeI3X3ci1IRY5R-Yp3QX4MohOwz6wBkURBGEK-zDWtvASARMXxh62E3xhQFdtjT8Pr54bHv58pPBj_4WTMn6_RIOm0abire01VFLTWOH9Yk1Vg3I34j51RTM3Jjyz3lxsQPCmvagkqv6RlLfEiN1U7PtVu8Wi5kY3rG8cvhoGd5_37qmZI7wxN-_pv_8a9-yQU_JDmxW2ytkrWlr6tzk10f96-OToPB5cnZ0cEgUKEQaVAqSisoAAgVUSKxgCz1GWMQISUYlWWhBKEsYp87yyhJE8CYStVFUcWVFJvs29I7bc3fmQ-dT7RVVNeyITOzOWYAGCYQoUd3l6hqjbUtVfm01RPZLnKE_LWDHPNVB57dWWlnxYTKd_Lf0j0QLIE7XdPi_6b8_OdK-H3JW6XdWy0f_P4C4lqfvQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1900126041</pqid></control><display><type>article</type><title>SU‐E‐T‐90: Investigation of Different Bleaching Wavelengths on the Absorbed‐Dose Sensitivity of NanoDot OSLDs Exposed to 6 MV X‐Ray Beams</title><source>Wiley Online Library Journals Frontfile Complete</source><source>Alma/SFX Local Collection</source><creator>Omotayo, A ; Cygler, J ; Sawakuchi, G</creator><creatorcontrib>Omotayo, A ; Cygler, J ; Sawakuchi, G</creatorcontrib><description>Purpose: To determine the effect of different bleaching wavelengths on the luminescence response of Al2O3:C optically stimulated luminescence detectors (OSLDs) exposed to accumulated doses of 6 MV photon beams. Methods: OSLDs of the nanoDot type were used and readout with a microStar InLight reader. To determine the effect of different bleaching wavelengths on the luminescence response of nanoDot OSLDs, we optically reset (bleached) the OSLDs with 26 W fluorescent lamps in two modes: (i) directly under the lamps for 10, 120 and 600 min; and (ii) with a long pass filter for 55, 600 and 2400 min. The long pass filter blocks wavelengths below 495 nm, hence the longer bleaching duration to attain equivalent OSL signals as bleaching directly under the lamps. Changes in the sensitivity of the nanoDot OSLDs were determined for an irradiation‐readout‐bleaching‐readout cycle, after irradiations with 1 and 10 Gy dose fractions. Results: The nanoDot OSLDs presented a linear response to dose up to 2 Gy and supra‐linear response afterwards. They produced different OSL signal loss and fading behaviors for doses of 1 and 10 Gy. OSLDs bleached for 120 min and 600 min without and with the filter in 1 Gy fractions, did not exhibit any significant change in sensitivity over an accumulated dose of 7 Gy. The OSLDs exposed with 10 Gy fractions exhibited a small under‐response when bleached with filter, and an over‐response when bleached directly without filter. Conclusions: The nanoDot OSLDs may be reused without a significant sensitivity change for accumulated doses below 7 Gy. However, for accumulated doses beyond 10 Gy, nanoDot OSLDs show significant sensitivity change and hence, need to be recalibrated for reuse. We also concluded that the light spectrum used to reset the OSLDs has an influence on the sensitivity of the detectors. Natural Sciences and Engineering Research Council of Canada</description><identifier>ISSN: 0094-2405</identifier><identifier>EISSN: 2473-4209</identifier><identifier>DOI: 10.1118/1.4735147</identifier><identifier>PMID: 28517131</identifier><identifier>CODEN: MPHYA6</identifier><language>eng</language><publisher>United States: American Association of Physicists in Medicine</publisher><subject>Luminescence ; Nanodots ; Optical sensors ; Optically stimulated luminescence ; Ozone ; Particle beam detectors ; Photons ; Visible spectra</subject><ispartof>Medical Physics, 2012-06, Vol.39 (6), p.3723-3723</ispartof><rights>American Association of Physicists in Medicine</rights><rights>2012 American Association of Physicists in Medicine</rights><rights>2012 American Association of Physicists in Medicine.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1118%2F1.4735147$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>309,310,314,776,780,785,786,1411,23910,23911,25119,27903,27904,45554</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28517131$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Omotayo, A</creatorcontrib><creatorcontrib>Cygler, J</creatorcontrib><creatorcontrib>Sawakuchi, G</creatorcontrib><title>SU‐E‐T‐90: Investigation of Different Bleaching Wavelengths on the Absorbed‐Dose Sensitivity of NanoDot OSLDs Exposed to 6 MV X‐Ray Beams</title><title>Medical Physics</title><addtitle>Med Phys</addtitle><description>Purpose: To determine the effect of different bleaching wavelengths on the luminescence response of Al2O3:C optically stimulated luminescence detectors (OSLDs) exposed to accumulated doses of 6 MV photon beams. Methods: OSLDs of the nanoDot type were used and readout with a microStar InLight reader. To determine the effect of different bleaching wavelengths on the luminescence response of nanoDot OSLDs, we optically reset (bleached) the OSLDs with 26 W fluorescent lamps in two modes: (i) directly under the lamps for 10, 120 and 600 min; and (ii) with a long pass filter for 55, 600 and 2400 min. The long pass filter blocks wavelengths below 495 nm, hence the longer bleaching duration to attain equivalent OSL signals as bleaching directly under the lamps. Changes in the sensitivity of the nanoDot OSLDs were determined for an irradiation‐readout‐bleaching‐readout cycle, after irradiations with 1 and 10 Gy dose fractions. Results: The nanoDot OSLDs presented a linear response to dose up to 2 Gy and supra‐linear response afterwards. They produced different OSL signal loss and fading behaviors for doses of 1 and 10 Gy. OSLDs bleached for 120 min and 600 min without and with the filter in 1 Gy fractions, did not exhibit any significant change in sensitivity over an accumulated dose of 7 Gy. The OSLDs exposed with 10 Gy fractions exhibited a small under‐response when bleached with filter, and an over‐response when bleached directly without filter. Conclusions: The nanoDot OSLDs may be reused without a significant sensitivity change for accumulated doses below 7 Gy. However, for accumulated doses beyond 10 Gy, nanoDot OSLDs show significant sensitivity change and hence, need to be recalibrated for reuse. We also concluded that the light spectrum used to reset the OSLDs has an influence on the sensitivity of the detectors. Natural Sciences and Engineering Research Council of Canada</description><subject>Luminescence</subject><subject>Nanodots</subject><subject>Optical sensors</subject><subject>Optically stimulated luminescence</subject><subject>Ozone</subject><subject>Particle beam detectors</subject><subject>Photons</subject><subject>Visible spectra</subject><issn>0094-2405</issn><issn>2473-4209</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNp9kctOGzEUhq2qqAToghdAXpZKA-eM55LpDki4SAGqBkp3I4_nTGI0GadjJ5Adj4DEG_IkGJKyK4sje_H5s_7zM7aNsIeI3X3ci1IRY5R-Yp3QX4MohOwz6wBkURBGEK-zDWtvASARMXxh62E3xhQFdtjT8Pr54bHv58pPBj_4WTMn6_RIOm0abire01VFLTWOH9Yk1Vg3I34j51RTM3Jjyz3lxsQPCmvagkqv6RlLfEiN1U7PtVu8Wi5kY3rG8cvhoGd5_37qmZI7wxN-_pv_8a9-yQU_JDmxW2ytkrWlr6tzk10f96-OToPB5cnZ0cEgUKEQaVAqSisoAAgVUSKxgCz1GWMQISUYlWWhBKEsYp87yyhJE8CYStVFUcWVFJvs29I7bc3fmQ-dT7RVVNeyITOzOWYAGCYQoUd3l6hqjbUtVfm01RPZLnKE_LWDHPNVB57dWWlnxYTKd_Lf0j0QLIE7XdPi_6b8_OdK-H3JW6XdWy0f_P4C4lqfvQ</recordid><startdate>201206</startdate><enddate>201206</enddate><creator>Omotayo, A</creator><creator>Cygler, J</creator><creator>Sawakuchi, G</creator><general>American Association of Physicists in Medicine</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201206</creationdate><title>SU‐E‐T‐90: Investigation of Different Bleaching Wavelengths on the Absorbed‐Dose Sensitivity of NanoDot OSLDs Exposed to 6 MV X‐Ray Beams</title><author>Omotayo, A ; Cygler, J ; Sawakuchi, G</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2337-dce7f0b00e1cee6a1b0970005032e614ddbc3e1ab500699e676015edc813f5fa3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Luminescence</topic><topic>Nanodots</topic><topic>Optical sensors</topic><topic>Optically stimulated luminescence</topic><topic>Ozone</topic><topic>Particle beam detectors</topic><topic>Photons</topic><topic>Visible spectra</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Omotayo, A</creatorcontrib><creatorcontrib>Cygler, J</creatorcontrib><creatorcontrib>Sawakuchi, G</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Medical Physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Omotayo, A</au><au>Cygler, J</au><au>Sawakuchi, G</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>SU‐E‐T‐90: Investigation of Different Bleaching Wavelengths on the Absorbed‐Dose Sensitivity of NanoDot OSLDs Exposed to 6 MV X‐Ray Beams</atitle><jtitle>Medical Physics</jtitle><addtitle>Med Phys</addtitle><date>2012-06</date><risdate>2012</risdate><volume>39</volume><issue>6</issue><spage>3723</spage><epage>3723</epage><pages>3723-3723</pages><issn>0094-2405</issn><eissn>2473-4209</eissn><coden>MPHYA6</coden><abstract>Purpose: To determine the effect of different bleaching wavelengths on the luminescence response of Al2O3:C optically stimulated luminescence detectors (OSLDs) exposed to accumulated doses of 6 MV photon beams. Methods: OSLDs of the nanoDot type were used and readout with a microStar InLight reader. To determine the effect of different bleaching wavelengths on the luminescence response of nanoDot OSLDs, we optically reset (bleached) the OSLDs with 26 W fluorescent lamps in two modes: (i) directly under the lamps for 10, 120 and 600 min; and (ii) with a long pass filter for 55, 600 and 2400 min. The long pass filter blocks wavelengths below 495 nm, hence the longer bleaching duration to attain equivalent OSL signals as bleaching directly under the lamps. Changes in the sensitivity of the nanoDot OSLDs were determined for an irradiation‐readout‐bleaching‐readout cycle, after irradiations with 1 and 10 Gy dose fractions. Results: The nanoDot OSLDs presented a linear response to dose up to 2 Gy and supra‐linear response afterwards. They produced different OSL signal loss and fading behaviors for doses of 1 and 10 Gy. OSLDs bleached for 120 min and 600 min without and with the filter in 1 Gy fractions, did not exhibit any significant change in sensitivity over an accumulated dose of 7 Gy. The OSLDs exposed with 10 Gy fractions exhibited a small under‐response when bleached with filter, and an over‐response when bleached directly without filter. Conclusions: The nanoDot OSLDs may be reused without a significant sensitivity change for accumulated doses below 7 Gy. However, for accumulated doses beyond 10 Gy, nanoDot OSLDs show significant sensitivity change and hence, need to be recalibrated for reuse. We also concluded that the light spectrum used to reset the OSLDs has an influence on the sensitivity of the detectors. Natural Sciences and Engineering Research Council of Canada</abstract><cop>United States</cop><pub>American Association of Physicists in Medicine</pub><pmid>28517131</pmid><doi>10.1118/1.4735147</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0094-2405
ispartof Medical Physics, 2012-06, Vol.39 (6), p.3723-3723
issn 0094-2405
2473-4209
language eng
recordid cdi_pubmed_primary_28517131
source Wiley Online Library Journals Frontfile Complete; Alma/SFX Local Collection
subjects Luminescence
Nanodots
Optical sensors
Optically stimulated luminescence
Ozone
Particle beam detectors
Photons
Visible spectra
title SU‐E‐T‐90: Investigation of Different Bleaching Wavelengths on the Absorbed‐Dose Sensitivity of NanoDot OSLDs Exposed to 6 MV X‐Ray Beams
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-23T14%3A44%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=SU%E2%80%90E%E2%80%90T%E2%80%9090:%20Investigation%20of%20Different%20Bleaching%20Wavelengths%20on%20the%20Absorbed%E2%80%90Dose%20Sensitivity%20of%20NanoDot%20OSLDs%20Exposed%20to%206%20MV%20X%E2%80%90Ray%20Beams&rft.jtitle=Medical%20Physics&rft.au=Omotayo,%20A&rft.date=2012-06&rft.volume=39&rft.issue=6&rft.spage=3723&rft.epage=3723&rft.pages=3723-3723&rft.issn=0094-2405&rft.eissn=2473-4209&rft.coden=MPHYA6&rft_id=info:doi/10.1118/1.4735147&rft_dat=%3Cproquest_pubme%3E1900126041%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1900126041&rft_id=info:pmid/28517131&rfr_iscdi=true