Optimal flushing agents for integrated optical and acoustic imaging systems

An increasing number of integrated optical and acoustic intravascular imaging systems have been developed and hold great promise for accurately diagnosing vulnerable plaques and guiding atherosclerosis treatment. However, in any intravascular environment, the vascular lumen is filled with blood, a h...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of biomedical optics 2015-05, Vol.20 (5), p.056005-056005
Hauptverfasser: Li, Jiawen, Minami, Hataka, Steward, Earl, Ma, Teng, Mohar, Dilbahar, Robertson, Claire, Shung, Kirk, Zhou, Qifa, Patel, Pranav, Chen, Zhongping
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 056005
container_issue 5
container_start_page 056005
container_title Journal of biomedical optics
container_volume 20
creator Li, Jiawen
Minami, Hataka
Steward, Earl
Ma, Teng
Mohar, Dilbahar
Robertson, Claire
Shung, Kirk
Zhou, Qifa
Patel, Pranav
Chen, Zhongping
description An increasing number of integrated optical and acoustic intravascular imaging systems have been developed and hold great promise for accurately diagnosing vulnerable plaques and guiding atherosclerosis treatment. However, in any intravascular environment, the vascular lumen is filled with blood, a high-scattering source for optical and high-frequency ultrasound signals. Blood must be flushed away to provide clearer images. To our knowledge, no research has been performed to find the ideal flushing agent for combined optical and acoustic imaging techniques. We selected three solutions as potential flushing agents for their image-enhancing effects: mannitol, dextran, and iohexol. Testing of these flushing agents was performed in a closed-loop circulation model and in vivo on rabbits. We found that a high concentration of dextran was the most useful for simultaneous intravascular ultrasound and optical coherence tomography imaging.
doi_str_mv 10.1117/1.JBO.20.5.056005
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmed_primary_25985096</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1682204110</sourcerecordid><originalsourceid>FETCH-LOGICAL-c515t-d62b7eea68cbb7a638a5cbfe8d2339fa4a090ea03ed72a25bb1dc5210f76e7fa3</originalsourceid><addsrcrecordid>eNp1kc1O3TAQhS1UVCjtA3RTZdlNwtiJHWdTidJSCki3C7q2HGccgnKT1E6Q6NN34AKFQlf-mXM-H88w9p5Dxjkv93l28nmVCchkBlIByC22y2mTCqH5K9qDztNcKb3D3sR4CQBaVeo12xGy0hIqtctOV9PcrW2f-H6JF93QJrbFYY6JH0PSDTO2wc7YJCPJHMns0CTWjUukY0LG9sYSr-OM6_iWbXvbR3x3t-6xn0dfzw-P07PVt--HB2epk1zOaaNEXSJapV1dl1bl2kpXe9SNyPPK28JCBWghx6YUVsi65o2TgoMvFZbe5nvs04Y7LfUaG0d5g-3NFChPuDaj7czTytBdmHa8MkWRS1EIAny8A4Tx14JxNusuOux7OyB9zXClhYCCcyAp30hdGGMM6B-e4WBuhmC4oSEYAUaazRDI8-FxvgfHfddJcL4RxKlDczkuYaB-_eX87qZ_obd3B4G63uOPL0fPylPjCZu9hP1_0D9L1q8X</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1682204110</pqid></control><display><type>article</type><title>Optimal flushing agents for integrated optical and acoustic imaging systems</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>PubMed Central</source><creator>Li, Jiawen ; Minami, Hataka ; Steward, Earl ; Ma, Teng ; Mohar, Dilbahar ; Robertson, Claire ; Shung, Kirk ; Zhou, Qifa ; Patel, Pranav ; Chen, Zhongping</creator><creatorcontrib>Li, Jiawen ; Minami, Hataka ; Steward, Earl ; Ma, Teng ; Mohar, Dilbahar ; Robertson, Claire ; Shung, Kirk ; Zhou, Qifa ; Patel, Pranav ; Chen, Zhongping</creatorcontrib><description>An increasing number of integrated optical and acoustic intravascular imaging systems have been developed and hold great promise for accurately diagnosing vulnerable plaques and guiding atherosclerosis treatment. However, in any intravascular environment, the vascular lumen is filled with blood, a high-scattering source for optical and high-frequency ultrasound signals. Blood must be flushed away to provide clearer images. To our knowledge, no research has been performed to find the ideal flushing agent for combined optical and acoustic imaging techniques. We selected three solutions as potential flushing agents for their image-enhancing effects: mannitol, dextran, and iohexol. Testing of these flushing agents was performed in a closed-loop circulation model and in vivo on rabbits. We found that a high concentration of dextran was the most useful for simultaneous intravascular ultrasound and optical coherence tomography imaging.</description><identifier>ISSN: 1083-3668</identifier><identifier>EISSN: 1560-2281</identifier><identifier>DOI: 10.1117/1.JBO.20.5.056005</identifier><identifier>PMID: 25985096</identifier><language>eng</language><publisher>United States: Society of Photo-Optical Instrumentation Engineers</publisher><subject>Animals ; Contrast Media ; Coronary Vessels - anatomy &amp; histology ; Coronary Vessels - diagnostic imaging ; Dextrans ; Image Enhancement - methods ; Iohexol ; Mannitol ; Rabbits ; Reproducibility of Results ; Research Papers: Imaging ; Sensitivity and Specificity ; Tomography, Optical Coherence - methods ; Ultrasonography, Interventional - methods</subject><ispartof>Journal of biomedical optics, 2015-05, Vol.20 (5), p.056005-056005</ispartof><rights>2015 Society of Photo-Optical Instrumentation Engineers (SPIE)</rights><rights>2015 Society of Photo-Optical Instrumentation Engineers (SPIE) 2015 Society of Photo-Optical Instrumentation Engineers</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c515t-d62b7eea68cbb7a638a5cbfe8d2339fa4a090ea03ed72a25bb1dc5210f76e7fa3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4435242/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4435242/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,727,780,784,885,27923,27924,53790,53792</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25985096$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Li, Jiawen</creatorcontrib><creatorcontrib>Minami, Hataka</creatorcontrib><creatorcontrib>Steward, Earl</creatorcontrib><creatorcontrib>Ma, Teng</creatorcontrib><creatorcontrib>Mohar, Dilbahar</creatorcontrib><creatorcontrib>Robertson, Claire</creatorcontrib><creatorcontrib>Shung, Kirk</creatorcontrib><creatorcontrib>Zhou, Qifa</creatorcontrib><creatorcontrib>Patel, Pranav</creatorcontrib><creatorcontrib>Chen, Zhongping</creatorcontrib><title>Optimal flushing agents for integrated optical and acoustic imaging systems</title><title>Journal of biomedical optics</title><addtitle>J. Biomed. Opt</addtitle><description>An increasing number of integrated optical and acoustic intravascular imaging systems have been developed and hold great promise for accurately diagnosing vulnerable plaques and guiding atherosclerosis treatment. However, in any intravascular environment, the vascular lumen is filled with blood, a high-scattering source for optical and high-frequency ultrasound signals. Blood must be flushed away to provide clearer images. To our knowledge, no research has been performed to find the ideal flushing agent for combined optical and acoustic imaging techniques. We selected three solutions as potential flushing agents for their image-enhancing effects: mannitol, dextran, and iohexol. Testing of these flushing agents was performed in a closed-loop circulation model and in vivo on rabbits. We found that a high concentration of dextran was the most useful for simultaneous intravascular ultrasound and optical coherence tomography imaging.</description><subject>Animals</subject><subject>Contrast Media</subject><subject>Coronary Vessels - anatomy &amp; histology</subject><subject>Coronary Vessels - diagnostic imaging</subject><subject>Dextrans</subject><subject>Image Enhancement - methods</subject><subject>Iohexol</subject><subject>Mannitol</subject><subject>Rabbits</subject><subject>Reproducibility of Results</subject><subject>Research Papers: Imaging</subject><subject>Sensitivity and Specificity</subject><subject>Tomography, Optical Coherence - methods</subject><subject>Ultrasonography, Interventional - methods</subject><issn>1083-3668</issn><issn>1560-2281</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kc1O3TAQhS1UVCjtA3RTZdlNwtiJHWdTidJSCki3C7q2HGccgnKT1E6Q6NN34AKFQlf-mXM-H88w9p5Dxjkv93l28nmVCchkBlIByC22y2mTCqH5K9qDztNcKb3D3sR4CQBaVeo12xGy0hIqtctOV9PcrW2f-H6JF93QJrbFYY6JH0PSDTO2wc7YJCPJHMns0CTWjUukY0LG9sYSr-OM6_iWbXvbR3x3t-6xn0dfzw-P07PVt--HB2epk1zOaaNEXSJapV1dl1bl2kpXe9SNyPPK28JCBWghx6YUVsi65o2TgoMvFZbe5nvs04Y7LfUaG0d5g-3NFChPuDaj7czTytBdmHa8MkWRS1EIAny8A4Tx14JxNusuOux7OyB9zXClhYCCcyAp30hdGGMM6B-e4WBuhmC4oSEYAUaazRDI8-FxvgfHfddJcL4RxKlDczkuYaB-_eX87qZ_obd3B4G63uOPL0fPylPjCZu9hP1_0D9L1q8X</recordid><startdate>20150501</startdate><enddate>20150501</enddate><creator>Li, Jiawen</creator><creator>Minami, Hataka</creator><creator>Steward, Earl</creator><creator>Ma, Teng</creator><creator>Mohar, Dilbahar</creator><creator>Robertson, Claire</creator><creator>Shung, Kirk</creator><creator>Zhou, Qifa</creator><creator>Patel, Pranav</creator><creator>Chen, Zhongping</creator><general>Society of Photo-Optical Instrumentation Engineers</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20150501</creationdate><title>Optimal flushing agents for integrated optical and acoustic imaging systems</title><author>Li, Jiawen ; Minami, Hataka ; Steward, Earl ; Ma, Teng ; Mohar, Dilbahar ; Robertson, Claire ; Shung, Kirk ; Zhou, Qifa ; Patel, Pranav ; Chen, Zhongping</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c515t-d62b7eea68cbb7a638a5cbfe8d2339fa4a090ea03ed72a25bb1dc5210f76e7fa3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Animals</topic><topic>Contrast Media</topic><topic>Coronary Vessels - anatomy &amp; histology</topic><topic>Coronary Vessels - diagnostic imaging</topic><topic>Dextrans</topic><topic>Image Enhancement - methods</topic><topic>Iohexol</topic><topic>Mannitol</topic><topic>Rabbits</topic><topic>Reproducibility of Results</topic><topic>Research Papers: Imaging</topic><topic>Sensitivity and Specificity</topic><topic>Tomography, Optical Coherence - methods</topic><topic>Ultrasonography, Interventional - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Li, Jiawen</creatorcontrib><creatorcontrib>Minami, Hataka</creatorcontrib><creatorcontrib>Steward, Earl</creatorcontrib><creatorcontrib>Ma, Teng</creatorcontrib><creatorcontrib>Mohar, Dilbahar</creatorcontrib><creatorcontrib>Robertson, Claire</creatorcontrib><creatorcontrib>Shung, Kirk</creatorcontrib><creatorcontrib>Zhou, Qifa</creatorcontrib><creatorcontrib>Patel, Pranav</creatorcontrib><creatorcontrib>Chen, Zhongping</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of biomedical optics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Li, Jiawen</au><au>Minami, Hataka</au><au>Steward, Earl</au><au>Ma, Teng</au><au>Mohar, Dilbahar</au><au>Robertson, Claire</au><au>Shung, Kirk</au><au>Zhou, Qifa</au><au>Patel, Pranav</au><au>Chen, Zhongping</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Optimal flushing agents for integrated optical and acoustic imaging systems</atitle><jtitle>Journal of biomedical optics</jtitle><addtitle>J. Biomed. Opt</addtitle><date>2015-05-01</date><risdate>2015</risdate><volume>20</volume><issue>5</issue><spage>056005</spage><epage>056005</epage><pages>056005-056005</pages><issn>1083-3668</issn><eissn>1560-2281</eissn><abstract>An increasing number of integrated optical and acoustic intravascular imaging systems have been developed and hold great promise for accurately diagnosing vulnerable plaques and guiding atherosclerosis treatment. However, in any intravascular environment, the vascular lumen is filled with blood, a high-scattering source for optical and high-frequency ultrasound signals. Blood must be flushed away to provide clearer images. To our knowledge, no research has been performed to find the ideal flushing agent for combined optical and acoustic imaging techniques. We selected three solutions as potential flushing agents for their image-enhancing effects: mannitol, dextran, and iohexol. Testing of these flushing agents was performed in a closed-loop circulation model and in vivo on rabbits. We found that a high concentration of dextran was the most useful for simultaneous intravascular ultrasound and optical coherence tomography imaging.</abstract><cop>United States</cop><pub>Society of Photo-Optical Instrumentation Engineers</pub><pmid>25985096</pmid><doi>10.1117/1.JBO.20.5.056005</doi><tpages>1</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1083-3668
ispartof Journal of biomedical optics, 2015-05, Vol.20 (5), p.056005-056005
issn 1083-3668
1560-2281
language eng
recordid cdi_pubmed_primary_25985096
source MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; PubMed Central
subjects Animals
Contrast Media
Coronary Vessels - anatomy & histology
Coronary Vessels - diagnostic imaging
Dextrans
Image Enhancement - methods
Iohexol
Mannitol
Rabbits
Reproducibility of Results
Research Papers: Imaging
Sensitivity and Specificity
Tomography, Optical Coherence - methods
Ultrasonography, Interventional - methods
title Optimal flushing agents for integrated optical and acoustic imaging systems
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T11%3A42%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Optimal%20flushing%20agents%20for%20integrated%20optical%20and%20acoustic%20imaging%20systems&rft.jtitle=Journal%20of%20biomedical%20optics&rft.au=Li,%20Jiawen&rft.date=2015-05-01&rft.volume=20&rft.issue=5&rft.spage=056005&rft.epage=056005&rft.pages=056005-056005&rft.issn=1083-3668&rft.eissn=1560-2281&rft_id=info:doi/10.1117/1.JBO.20.5.056005&rft_dat=%3Cproquest_pubme%3E1682204110%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1682204110&rft_id=info:pmid/25985096&rfr_iscdi=true