Optimization of operation of a three-electrode gyrotron with the use of a flow-type calorimeter
Results are presented for measurements of microwave power of the Borets-75/0.8 gyrotron with recovery of residual electron energy, which were performed by a flow-type calorimeter. This gyrotron is a part of the ECR plasma heating complex put into operation in 2010 at the L-2M stellarator. The new ca...
Gespeichert in:
Veröffentlicht in: | Review of scientific instruments 2013-01, Vol.84 (1), p.013507-013507 |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 013507 |
---|---|
container_issue | 1 |
container_start_page | 013507 |
container_title | Review of scientific instruments |
container_volume | 84 |
creator | Kharchev, Nikolay K. Batanov, German M. Kolik, Leonid V. Malakhov, Dmitrii V. Petrov, Aleksandr Ye Sarksyan, Karen A. Skvortsova, Nina N. Stepakhin, Vladimir D. Belousov, Vladimir I. Malygin, Sergei A. Tai, Yevgenii M. |
description | Results are presented for measurements of microwave power of the Borets-75/0.8 gyrotron with recovery of residual electron energy, which were performed by a flow-type calorimeter. This gyrotron is a part of the ECR plasma heating complex put into operation in 2010 at the L-2M stellarator. The new calorimeter is capable of measuring microwave power up to 0.5 MW. Monitoring of the microwave power makes it possible to control the parameters of the gyrotron power supply unit (its voltage and current) and the magnetic field of the cryomagnet in order to optimize the gyrotron operation and arrive at maximum efficiency. |
doi_str_mv | 10.1063/1.4773544 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmed_primary_23387650</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1429864212</sourcerecordid><originalsourceid>FETCH-LOGICAL-c416t-e64748d60f8895979604c63ab871b35c6eafde361a9f7fd7e614066e0dcfbac83</originalsourceid><addsrcrecordid>eNqF0c9rHCEUB3AJDckm7aH_QBnopQlMoqM-nWMJ_QWBXJqzuM4zO2V2nKrbsP3r43Y220Oh8aLih-d7fAl5y-gVo8Cv2ZVQikshjsiCUd3WChr-iiwo5aIGJfQpOUvpBy1LMnZCThvOtQJJF8TcTblf979t7sNYBV-FCePhYqu8iog1DuhyDB1WD9sYymmsHvu8Kq9YbRLO1A_hsc7bCStnhxD7NWaMr8mxt0PCN_v9nNx__vT95mt9e_fl283H29oJBrlGEKXNDqjXupWtaoEKB9wutWJLLh2g9R1yYLb1yncKgQkKgLRzfmmd5ufk_Vw3pNyb5PqMbuXCOJbGTdMwKrncqQ-zmmL4ucGUzbpPDofBjhg2yTDRtBpEw5qXaaOlAAmaFnoxUxdDShG9mcr0Nm4No2YXkGFmH1Cx7_ZlN8s1dgf5nEgBlzPYzfAniIP5FeLfSmbq_P_wv18_Ab52pko</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1285465680</pqid></control><display><type>article</type><title>Optimization of operation of a three-electrode gyrotron with the use of a flow-type calorimeter</title><source>AIP Journals Complete</source><source>AIP Digital Archive</source><source>Alma/SFX Local Collection</source><creator>Kharchev, Nikolay K. ; Batanov, German M. ; Kolik, Leonid V. ; Malakhov, Dmitrii V. ; Petrov, Aleksandr Ye ; Sarksyan, Karen A. ; Skvortsova, Nina N. ; Stepakhin, Vladimir D. ; Belousov, Vladimir I. ; Malygin, Sergei A. ; Tai, Yevgenii M.</creator><creatorcontrib>Kharchev, Nikolay K. ; Batanov, German M. ; Kolik, Leonid V. ; Malakhov, Dmitrii V. ; Petrov, Aleksandr Ye ; Sarksyan, Karen A. ; Skvortsova, Nina N. ; Stepakhin, Vladimir D. ; Belousov, Vladimir I. ; Malygin, Sergei A. ; Tai, Yevgenii M.</creatorcontrib><description>Results are presented for measurements of microwave power of the Borets-75/0.8 gyrotron with recovery of residual electron energy, which were performed by a flow-type calorimeter. This gyrotron is a part of the ECR plasma heating complex put into operation in 2010 at the L-2M stellarator. The new calorimeter is capable of measuring microwave power up to 0.5 MW. Monitoring of the microwave power makes it possible to control the parameters of the gyrotron power supply unit (its voltage and current) and the magnetic field of the cryomagnet in order to optimize the gyrotron operation and arrive at maximum efficiency.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.4773544</identifier><identifier>PMID: 23387650</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>United States</publisher><subject>70 PLASMA PHYSICS AND FUSION TECHNOLOGY ; CALORIMETERS ; Electric potential ; ELECTRODES ; ELECTRON CYCLOTRON-RESONANCE ; Gyrotrons ; INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY ; Magnetic fields ; MICROWAVE AMPLIFIERS ; MICROWAVE HEATING ; Microwaves ; Monitoring ; OPERATION ; OPTIMIZATION ; PLASMA HEATING ; Power supplies ; RF SYSTEMS ; Voltage</subject><ispartof>Review of scientific instruments, 2013-01, Vol.84 (1), p.013507-013507</ispartof><rights>American Institute of Physics</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c416t-e64748d60f8895979604c63ab871b35c6eafde361a9f7fd7e614066e0dcfbac83</citedby><cites>FETCH-LOGICAL-c416t-e64748d60f8895979604c63ab871b35c6eafde361a9f7fd7e614066e0dcfbac83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.4773544$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>230,314,776,780,790,881,1553,4498,27901,27902,76127,76133</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23387650$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://www.osti.gov/biblio/22105358$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Kharchev, Nikolay K.</creatorcontrib><creatorcontrib>Batanov, German M.</creatorcontrib><creatorcontrib>Kolik, Leonid V.</creatorcontrib><creatorcontrib>Malakhov, Dmitrii V.</creatorcontrib><creatorcontrib>Petrov, Aleksandr Ye</creatorcontrib><creatorcontrib>Sarksyan, Karen A.</creatorcontrib><creatorcontrib>Skvortsova, Nina N.</creatorcontrib><creatorcontrib>Stepakhin, Vladimir D.</creatorcontrib><creatorcontrib>Belousov, Vladimir I.</creatorcontrib><creatorcontrib>Malygin, Sergei A.</creatorcontrib><creatorcontrib>Tai, Yevgenii M.</creatorcontrib><title>Optimization of operation of a three-electrode gyrotron with the use of a flow-type calorimeter</title><title>Review of scientific instruments</title><addtitle>Rev Sci Instrum</addtitle><description>Results are presented for measurements of microwave power of the Borets-75/0.8 gyrotron with recovery of residual electron energy, which were performed by a flow-type calorimeter. This gyrotron is a part of the ECR plasma heating complex put into operation in 2010 at the L-2M stellarator. The new calorimeter is capable of measuring microwave power up to 0.5 MW. Monitoring of the microwave power makes it possible to control the parameters of the gyrotron power supply unit (its voltage and current) and the magnetic field of the cryomagnet in order to optimize the gyrotron operation and arrive at maximum efficiency.</description><subject>70 PLASMA PHYSICS AND FUSION TECHNOLOGY</subject><subject>CALORIMETERS</subject><subject>Electric potential</subject><subject>ELECTRODES</subject><subject>ELECTRON CYCLOTRON-RESONANCE</subject><subject>Gyrotrons</subject><subject>INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY</subject><subject>Magnetic fields</subject><subject>MICROWAVE AMPLIFIERS</subject><subject>MICROWAVE HEATING</subject><subject>Microwaves</subject><subject>Monitoring</subject><subject>OPERATION</subject><subject>OPTIMIZATION</subject><subject>PLASMA HEATING</subject><subject>Power supplies</subject><subject>RF SYSTEMS</subject><subject>Voltage</subject><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNqF0c9rHCEUB3AJDckm7aH_QBnopQlMoqM-nWMJ_QWBXJqzuM4zO2V2nKrbsP3r43Y220Oh8aLih-d7fAl5y-gVo8Cv2ZVQikshjsiCUd3WChr-iiwo5aIGJfQpOUvpBy1LMnZCThvOtQJJF8TcTblf979t7sNYBV-FCePhYqu8iog1DuhyDB1WD9sYymmsHvu8Kq9YbRLO1A_hsc7bCStnhxD7NWaMr8mxt0PCN_v9nNx__vT95mt9e_fl283H29oJBrlGEKXNDqjXupWtaoEKB9wutWJLLh2g9R1yYLb1yncKgQkKgLRzfmmd5ufk_Vw3pNyb5PqMbuXCOJbGTdMwKrncqQ-zmmL4ucGUzbpPDofBjhg2yTDRtBpEw5qXaaOlAAmaFnoxUxdDShG9mcr0Nm4No2YXkGFmH1Cx7_ZlN8s1dgf5nEgBlzPYzfAniIP5FeLfSmbq_P_wv18_Ab52pko</recordid><startdate>20130101</startdate><enddate>20130101</enddate><creator>Kharchev, Nikolay K.</creator><creator>Batanov, German M.</creator><creator>Kolik, Leonid V.</creator><creator>Malakhov, Dmitrii V.</creator><creator>Petrov, Aleksandr Ye</creator><creator>Sarksyan, Karen A.</creator><creator>Skvortsova, Nina N.</creator><creator>Stepakhin, Vladimir D.</creator><creator>Belousov, Vladimir I.</creator><creator>Malygin, Sergei A.</creator><creator>Tai, Yevgenii M.</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>OTOTI</scope></search><sort><creationdate>20130101</creationdate><title>Optimization of operation of a three-electrode gyrotron with the use of a flow-type calorimeter</title><author>Kharchev, Nikolay K. ; Batanov, German M. ; Kolik, Leonid V. ; Malakhov, Dmitrii V. ; Petrov, Aleksandr Ye ; Sarksyan, Karen A. ; Skvortsova, Nina N. ; Stepakhin, Vladimir D. ; Belousov, Vladimir I. ; Malygin, Sergei A. ; Tai, Yevgenii M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c416t-e64748d60f8895979604c63ab871b35c6eafde361a9f7fd7e614066e0dcfbac83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>70 PLASMA PHYSICS AND FUSION TECHNOLOGY</topic><topic>CALORIMETERS</topic><topic>Electric potential</topic><topic>ELECTRODES</topic><topic>ELECTRON CYCLOTRON-RESONANCE</topic><topic>Gyrotrons</topic><topic>INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY</topic><topic>Magnetic fields</topic><topic>MICROWAVE AMPLIFIERS</topic><topic>MICROWAVE HEATING</topic><topic>Microwaves</topic><topic>Monitoring</topic><topic>OPERATION</topic><topic>OPTIMIZATION</topic><topic>PLASMA HEATING</topic><topic>Power supplies</topic><topic>RF SYSTEMS</topic><topic>Voltage</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kharchev, Nikolay K.</creatorcontrib><creatorcontrib>Batanov, German M.</creatorcontrib><creatorcontrib>Kolik, Leonid V.</creatorcontrib><creatorcontrib>Malakhov, Dmitrii V.</creatorcontrib><creatorcontrib>Petrov, Aleksandr Ye</creatorcontrib><creatorcontrib>Sarksyan, Karen A.</creatorcontrib><creatorcontrib>Skvortsova, Nina N.</creatorcontrib><creatorcontrib>Stepakhin, Vladimir D.</creatorcontrib><creatorcontrib>Belousov, Vladimir I.</creatorcontrib><creatorcontrib>Malygin, Sergei A.</creatorcontrib><creatorcontrib>Tai, Yevgenii M.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Electronics & Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>OSTI.GOV</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kharchev, Nikolay K.</au><au>Batanov, German M.</au><au>Kolik, Leonid V.</au><au>Malakhov, Dmitrii V.</au><au>Petrov, Aleksandr Ye</au><au>Sarksyan, Karen A.</au><au>Skvortsova, Nina N.</au><au>Stepakhin, Vladimir D.</au><au>Belousov, Vladimir I.</au><au>Malygin, Sergei A.</au><au>Tai, Yevgenii M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Optimization of operation of a three-electrode gyrotron with the use of a flow-type calorimeter</atitle><jtitle>Review of scientific instruments</jtitle><addtitle>Rev Sci Instrum</addtitle><date>2013-01-01</date><risdate>2013</risdate><volume>84</volume><issue>1</issue><spage>013507</spage><epage>013507</epage><pages>013507-013507</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>Results are presented for measurements of microwave power of the Borets-75/0.8 gyrotron with recovery of residual electron energy, which were performed by a flow-type calorimeter. This gyrotron is a part of the ECR plasma heating complex put into operation in 2010 at the L-2M stellarator. The new calorimeter is capable of measuring microwave power up to 0.5 MW. Monitoring of the microwave power makes it possible to control the parameters of the gyrotron power supply unit (its voltage and current) and the magnetic field of the cryomagnet in order to optimize the gyrotron operation and arrive at maximum efficiency.</abstract><cop>United States</cop><pmid>23387650</pmid><doi>10.1063/1.4773544</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0034-6748 |
ispartof | Review of scientific instruments, 2013-01, Vol.84 (1), p.013507-013507 |
issn | 0034-6748 1089-7623 |
language | eng |
recordid | cdi_pubmed_primary_23387650 |
source | AIP Journals Complete; AIP Digital Archive; Alma/SFX Local Collection |
subjects | 70 PLASMA PHYSICS AND FUSION TECHNOLOGY CALORIMETERS Electric potential ELECTRODES ELECTRON CYCLOTRON-RESONANCE Gyrotrons INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY Magnetic fields MICROWAVE AMPLIFIERS MICROWAVE HEATING Microwaves Monitoring OPERATION OPTIMIZATION PLASMA HEATING Power supplies RF SYSTEMS Voltage |
title | Optimization of operation of a three-electrode gyrotron with the use of a flow-type calorimeter |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T21%3A46%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Optimization%20of%20operation%20of%20a%20three-electrode%20gyrotron%20with%20the%20use%20of%20a%20flow-type%20calorimeter&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Kharchev,%20Nikolay%20K.&rft.date=2013-01-01&rft.volume=84&rft.issue=1&rft.spage=013507&rft.epage=013507&rft.pages=013507-013507&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.4773544&rft_dat=%3Cproquest_pubme%3E1429864212%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1285465680&rft_id=info:pmid/23387650&rfr_iscdi=true |