The influence of orifice height on flow rate of powder excipients
The influence of the orifice height of a cylindrical, flat-bottomed hopper on the mass flow rate of the free-flowable size fractions of sodium chloride and boric acid was investigated. It was observed that a zone of sudden acceleration of the mass flow under gravity occurred when a critical orifice...
Gespeichert in:
Veröffentlicht in: | Pharmazie 2011-12, Vol.66 (12), p.953-955 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 955 |
---|---|
container_issue | 12 |
container_start_page | 953 |
container_title | Pharmazie |
container_volume | 66 |
creator | Zatloukal Šklubalová |
description | The influence of the orifice height of a cylindrical, flat-bottomed hopper on the mass flow rate of the free-flowable size fractions of sodium chloride and boric acid was investigated. It was observed that a zone of sudden acceleration of the mass flow under gravity occurred when a
critical orifice height had been achieved. Based on the results, an orifice diameter equal to 12 mm with a height of between 8-16 mm is recommended for the faster flow of sodium chloride while an orifice diameter equal to 8 mm with a height of less than 8 mm is appropriate for the slower
flow of boric acid. In summary, the orifice height should be taken into consideration as an important parameter of a cylindrical test hopper in order to obtain a reproducible and comparable mass flow as the single-point characteristic of powder flowability. |
doi_str_mv | 10.1691/ph.2011.1074 |
format | Article |
fullrecord | <record><control><sourceid>pubtec_pubme</sourceid><recordid>TN_cdi_pubmed_primary_22312701</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ingid>govi/pharmaz/2011/00000066/00000012/art00010</ingid><sourcerecordid>govi/pharmaz/2011/00000066/00000012/art00010</sourcerecordid><originalsourceid>FETCH-LOGICAL-i344t-529eeeaa6bfdde20e550b3fa227692ff3d85483ded5246943b845059819857ac3</originalsourceid><addsrcrecordid>eNp1kbtPwzAQxj2AaClszCgbU4tfcZyxKk-pEgxltpzknLhK4-AkBfrX4z4YueU-6b776R4I3RA8IyIl9201o5iQGcEJP0NjjBmZJoTzEbrsujXGVFAhL9CIUkZogskYzVcVRLYx9QBNDpEzkfPW2CArsGXVR66JTO2-Iq_7Q7l1XwX4CL5z21po-u4KnRtdd3B9yhP08fS4WrxMl2_Pr4v5cmoZ5_00pikAaC0yUxRAMcQxzpjRlCYipcawQsZcsgKKmHKRcpZJHuM4lSSVcaJzNkF3R27r3ecAXa82tsuhrnUDbuhUSnEihUxJcN6enEO2gUK13m60_1F_WwfDw9FgmzKsoNXaDb4Jw6vSba1qK-03eqf2p1T4EEKcBKFK-34vcMC8_4Ox-ZG0f8D-_morRBNaKaYES8IUCUhVgNFD3atee1XuVBeQv3uRhlM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>920786891</pqid></control><display><type>article</type><title>The influence of orifice height on flow rate of powder excipients</title><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>IngentaConnect Free/Open Access Journals</source><creator>Zatloukal ; Šklubalová</creator><creatorcontrib>Zatloukal ; Šklubalová</creatorcontrib><description>The influence of the orifice height of a cylindrical, flat-bottomed hopper on the mass flow rate of the free-flowable size fractions of sodium chloride and boric acid was investigated. It was observed that a zone of sudden acceleration of the mass flow under gravity occurred when a
critical orifice height had been achieved. Based on the results, an orifice diameter equal to 12 mm with a height of between 8-16 mm is recommended for the faster flow of sodium chloride while an orifice diameter equal to 8 mm with a height of less than 8 mm is appropriate for the slower
flow of boric acid. In summary, the orifice height should be taken into consideration as an important parameter of a cylindrical test hopper in order to obtain a reproducible and comparable mass flow as the single-point characteristic of powder flowability.</description><identifier>ISSN: 0031-7144</identifier><identifier>DOI: 10.1691/ph.2011.1074</identifier><identifier>PMID: 22312701</identifier><language>eng</language><publisher>Germany: Govi-Verlag</publisher><subject>Boric Acids ; Excipients ; Humidity ; Particle Size ; Powders ; Reproducibility of Results ; Sodium Chloride ; Technology, Pharmaceutical - standards ; Temperature ; Vibration</subject><ispartof>Pharmazie, 2011-12, Vol.66 (12), p.953-955</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>288,314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/22312701$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Zatloukal</creatorcontrib><creatorcontrib>Šklubalová</creatorcontrib><title>The influence of orifice height on flow rate of powder excipients</title><title>Pharmazie</title><addtitle>Pharmazie</addtitle><addtitle>Pharmazie</addtitle><description>The influence of the orifice height of a cylindrical, flat-bottomed hopper on the mass flow rate of the free-flowable size fractions of sodium chloride and boric acid was investigated. It was observed that a zone of sudden acceleration of the mass flow under gravity occurred when a
critical orifice height had been achieved. Based on the results, an orifice diameter equal to 12 mm with a height of between 8-16 mm is recommended for the faster flow of sodium chloride while an orifice diameter equal to 8 mm with a height of less than 8 mm is appropriate for the slower
flow of boric acid. In summary, the orifice height should be taken into consideration as an important parameter of a cylindrical test hopper in order to obtain a reproducible and comparable mass flow as the single-point characteristic of powder flowability.</description><subject>Boric Acids</subject><subject>Excipients</subject><subject>Humidity</subject><subject>Particle Size</subject><subject>Powders</subject><subject>Reproducibility of Results</subject><subject>Sodium Chloride</subject><subject>Technology, Pharmaceutical - standards</subject><subject>Temperature</subject><subject>Vibration</subject><issn>0031-7144</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kbtPwzAQxj2AaClszCgbU4tfcZyxKk-pEgxltpzknLhK4-AkBfrX4z4YueU-6b776R4I3RA8IyIl9201o5iQGcEJP0NjjBmZJoTzEbrsujXGVFAhL9CIUkZogskYzVcVRLYx9QBNDpEzkfPW2CArsGXVR66JTO2-Iq_7Q7l1XwX4CL5z21po-u4KnRtdd3B9yhP08fS4WrxMl2_Pr4v5cmoZ5_00pikAaC0yUxRAMcQxzpjRlCYipcawQsZcsgKKmHKRcpZJHuM4lSSVcaJzNkF3R27r3ecAXa82tsuhrnUDbuhUSnEihUxJcN6enEO2gUK13m60_1F_WwfDw9FgmzKsoNXaDb4Jw6vSba1qK-03eqf2p1T4EEKcBKFK-34vcMC8_4Ox-ZG0f8D-_morRBNaKaYES8IUCUhVgNFD3atee1XuVBeQv3uRhlM</recordid><startdate>20111201</startdate><enddate>20111201</enddate><creator>Zatloukal</creator><creator>Šklubalová</creator><general>Govi-Verlag</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>20111201</creationdate><title>The influence of orifice height on flow rate of powder excipients</title><author>Zatloukal ; Šklubalová</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i344t-529eeeaa6bfdde20e550b3fa227692ff3d85483ded5246943b845059819857ac3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Boric Acids</topic><topic>Excipients</topic><topic>Humidity</topic><topic>Particle Size</topic><topic>Powders</topic><topic>Reproducibility of Results</topic><topic>Sodium Chloride</topic><topic>Technology, Pharmaceutical - standards</topic><topic>Temperature</topic><topic>Vibration</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zatloukal</creatorcontrib><creatorcontrib>Šklubalová</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Pharmazie</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zatloukal</au><au>Šklubalová</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The influence of orifice height on flow rate of powder excipients</atitle><jtitle>Pharmazie</jtitle><stitle>Pharmazie</stitle><addtitle>Pharmazie</addtitle><date>2011-12-01</date><risdate>2011</risdate><volume>66</volume><issue>12</issue><spage>953</spage><epage>955</epage><pages>953-955</pages><issn>0031-7144</issn><abstract>The influence of the orifice height of a cylindrical, flat-bottomed hopper on the mass flow rate of the free-flowable size fractions of sodium chloride and boric acid was investigated. It was observed that a zone of sudden acceleration of the mass flow under gravity occurred when a
critical orifice height had been achieved. Based on the results, an orifice diameter equal to 12 mm with a height of between 8-16 mm is recommended for the faster flow of sodium chloride while an orifice diameter equal to 8 mm with a height of less than 8 mm is appropriate for the slower
flow of boric acid. In summary, the orifice height should be taken into consideration as an important parameter of a cylindrical test hopper in order to obtain a reproducible and comparable mass flow as the single-point characteristic of powder flowability.</abstract><cop>Germany</cop><pub>Govi-Verlag</pub><pmid>22312701</pmid><doi>10.1691/ph.2011.1074</doi><tpages>3</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0031-7144 |
ispartof | Pharmazie, 2011-12, Vol.66 (12), p.953-955 |
issn | 0031-7144 |
language | eng |
recordid | cdi_pubmed_primary_22312701 |
source | MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; IngentaConnect Free/Open Access Journals |
subjects | Boric Acids Excipients Humidity Particle Size Powders Reproducibility of Results Sodium Chloride Technology, Pharmaceutical - standards Temperature Vibration |
title | The influence of orifice height on flow rate of powder excipients |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T20%3A11%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubtec_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20influence%20of%20orifice%20height%20on%20flow%20rate%20of%20powder%20excipients&rft.jtitle=Pharmazie&rft.au=Zatloukal&rft.date=2011-12-01&rft.volume=66&rft.issue=12&rft.spage=953&rft.epage=955&rft.pages=953-955&rft.issn=0031-7144&rft_id=info:doi/10.1691/ph.2011.1074&rft_dat=%3Cpubtec_pubme%3Egovi/pharmaz/2011/00000066/00000012/art00010%3C/pubtec_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=920786891&rft_id=info:pmid/22312701&rft_ingid=govi/pharmaz/2011/00000066/00000012/art00010&rfr_iscdi=true |