Catheter Placement for Ommaya Reservoirs with Frameless Surgical Navigation: Technical Note

Objective: Infusion of intraventricular chemotherapy requires precise ventricular catheter placement in oncology patients to avoid intraparenchymal infusion. We assessed the safety and precision of using frameless surgical navigation for the placement of Ommaya reservoir catheters. Methods: In 20 co...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Stereotactic and functional neurosurgery 2008-01, Vol.86 (2), p.101-105
Hauptverfasser: Greenfield, Jeffrey P., Schwartz, Theodore H.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 105
container_issue 2
container_start_page 101
container_title Stereotactic and functional neurosurgery
container_volume 86
creator Greenfield, Jeffrey P.
Schwartz, Theodore H.
description Objective: Infusion of intraventricular chemotherapy requires precise ventricular catheter placement in oncology patients to avoid intraparenchymal infusion. We assessed the safety and precision of using frameless surgical navigation for the placement of Ommaya reservoir catheters. Methods: In 20 consecutive patients who required Ommaya reservoirs for the administration of intrathecal chemotherapy, the catheters were positioned with the guidance of frameless stereotaxy. Precision of catheter placement, operative time, operative complications, and postoperative complications were assessed. Results: All catheters were completely within cerebrospinal fluid and 90% were within 5 mm of the intended target, the ipsilateral foramen of Monro. The average operative time was 47 min, and there were no intraoperative complications. There were no reports of leukoencephalopathy, and 3 patients had minor delayed complications. Conclusion: Frameless surgical navigation is a useful and efficient method for ensuring accurate catheter placement during Ommaya reservoir implantation, and it reduces the risk of potential parenchymal toxicity.
doi_str_mv 10.1159/000112431
format Article
fullrecord <record><control><sourceid>pubmed_cross</sourceid><recordid>TN_cdi_pubmed_primary_18073523</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>18073523</sourcerecordid><originalsourceid>FETCH-LOGICAL-c304t-59db77c5e09cae6f510cd77bd729d5e943231b33d82c623f841887a1f224feb13</originalsourceid><addsrcrecordid>eNpF0D1PwzAQBmALgWgpDOwIeWUI-PxRJ2yoagGpogjKxBA5zqUNJE1lu0X99wSlotOdXj13w0vIJbBbAJXcMcYAuBRwRPoguYiY0Py43ds4GgJXPXLm_VfLhNTxKelBzLRQXPTJ58iEJQZ09LUyFmtcBVo0js7q2uwMfUOPbtuUztOfMizpxJkaK_Sevm_corSmoi9mWy5MKJvVPZ2jXa66tAl4Tk4KU3m82M8B-ZiM56OnaDp7fB49TCMrmAyRSvJMa6uQJdbgsFDAbK51lmue5AoTKbiATIg85nbIRRFLiGNtoOBcFpiBGJCb7q91jfcOi3Ttytq4XQos_Sso_S-otdedXW-yGvOD3DfSgqsOfBu3QHcA3f0vwvdpOg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Catheter Placement for Ommaya Reservoirs with Frameless Surgical Navigation: Technical Note</title><source>MEDLINE</source><source>Karger Journals</source><source>Alma/SFX Local Collection</source><creator>Greenfield, Jeffrey P. ; Schwartz, Theodore H.</creator><creatorcontrib>Greenfield, Jeffrey P. ; Schwartz, Theodore H.</creatorcontrib><description>Objective: Infusion of intraventricular chemotherapy requires precise ventricular catheter placement in oncology patients to avoid intraparenchymal infusion. We assessed the safety and precision of using frameless surgical navigation for the placement of Ommaya reservoir catheters. Methods: In 20 consecutive patients who required Ommaya reservoirs for the administration of intrathecal chemotherapy, the catheters were positioned with the guidance of frameless stereotaxy. Precision of catheter placement, operative time, operative complications, and postoperative complications were assessed. Results: All catheters were completely within cerebrospinal fluid and 90% were within 5 mm of the intended target, the ipsilateral foramen of Monro. The average operative time was 47 min, and there were no intraoperative complications. There were no reports of leukoencephalopathy, and 3 patients had minor delayed complications. Conclusion: Frameless surgical navigation is a useful and efficient method for ensuring accurate catheter placement during Ommaya reservoir implantation, and it reduces the risk of potential parenchymal toxicity.</description><identifier>ISSN: 1011-6125</identifier><identifier>EISSN: 1423-0372</identifier><identifier>DOI: 10.1159/000112431</identifier><identifier>PMID: 18073523</identifier><language>eng</language><publisher>Basel, Switzerland</publisher><subject>Adult ; Aged ; Antineoplastic Agents - administration &amp; dosage ; Antineoplastic Agents - therapeutic use ; Catheterization - instrumentation ; Catheterization - methods ; Catheters, Indwelling ; Central Nervous System Neoplasms - drug therapy ; Clinical Study ; Drug Delivery Systems - instrumentation ; Drug Delivery Systems - methods ; Female ; Humans ; Lymphoma - drug therapy ; Male ; Middle Aged ; Neuronavigation - methods ; Neurosurgical Procedures - methods</subject><ispartof>Stereotactic and functional neurosurgery, 2008-01, Vol.86 (2), p.101-105</ispartof><rights>2007 S. Karger AG, Basel</rights><rights>(c) 2007 S. Karger AG, Basel</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c304t-59db77c5e09cae6f510cd77bd729d5e943231b33d82c623f841887a1f224feb13</citedby><cites>FETCH-LOGICAL-c304t-59db77c5e09cae6f510cd77bd729d5e943231b33d82c623f841887a1f224feb13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,2429,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/18073523$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Greenfield, Jeffrey P.</creatorcontrib><creatorcontrib>Schwartz, Theodore H.</creatorcontrib><title>Catheter Placement for Ommaya Reservoirs with Frameless Surgical Navigation: Technical Note</title><title>Stereotactic and functional neurosurgery</title><addtitle>Stereotact Funct Neurosurg</addtitle><description>Objective: Infusion of intraventricular chemotherapy requires precise ventricular catheter placement in oncology patients to avoid intraparenchymal infusion. We assessed the safety and precision of using frameless surgical navigation for the placement of Ommaya reservoir catheters. Methods: In 20 consecutive patients who required Ommaya reservoirs for the administration of intrathecal chemotherapy, the catheters were positioned with the guidance of frameless stereotaxy. Precision of catheter placement, operative time, operative complications, and postoperative complications were assessed. Results: All catheters were completely within cerebrospinal fluid and 90% were within 5 mm of the intended target, the ipsilateral foramen of Monro. The average operative time was 47 min, and there were no intraoperative complications. There were no reports of leukoencephalopathy, and 3 patients had minor delayed complications. Conclusion: Frameless surgical navigation is a useful and efficient method for ensuring accurate catheter placement during Ommaya reservoir implantation, and it reduces the risk of potential parenchymal toxicity.</description><subject>Adult</subject><subject>Aged</subject><subject>Antineoplastic Agents - administration &amp; dosage</subject><subject>Antineoplastic Agents - therapeutic use</subject><subject>Catheterization - instrumentation</subject><subject>Catheterization - methods</subject><subject>Catheters, Indwelling</subject><subject>Central Nervous System Neoplasms - drug therapy</subject><subject>Clinical Study</subject><subject>Drug Delivery Systems - instrumentation</subject><subject>Drug Delivery Systems - methods</subject><subject>Female</subject><subject>Humans</subject><subject>Lymphoma - drug therapy</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Neuronavigation - methods</subject><subject>Neurosurgical Procedures - methods</subject><issn>1011-6125</issn><issn>1423-0372</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpF0D1PwzAQBmALgWgpDOwIeWUI-PxRJ2yoagGpogjKxBA5zqUNJE1lu0X99wSlotOdXj13w0vIJbBbAJXcMcYAuBRwRPoguYiY0Py43ds4GgJXPXLm_VfLhNTxKelBzLRQXPTJ58iEJQZ09LUyFmtcBVo0js7q2uwMfUOPbtuUztOfMizpxJkaK_Sevm_corSmoi9mWy5MKJvVPZ2jXa66tAl4Tk4KU3m82M8B-ZiM56OnaDp7fB49TCMrmAyRSvJMa6uQJdbgsFDAbK51lmue5AoTKbiATIg85nbIRRFLiGNtoOBcFpiBGJCb7q91jfcOi3Ttytq4XQos_Sso_S-otdedXW-yGvOD3DfSgqsOfBu3QHcA3f0vwvdpOg</recordid><startdate>20080101</startdate><enddate>20080101</enddate><creator>Greenfield, Jeffrey P.</creator><creator>Schwartz, Theodore H.</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20080101</creationdate><title>Catheter Placement for Ommaya Reservoirs with Frameless Surgical Navigation: Technical Note</title><author>Greenfield, Jeffrey P. ; Schwartz, Theodore H.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c304t-59db77c5e09cae6f510cd77bd729d5e943231b33d82c623f841887a1f224feb13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Antineoplastic Agents - administration &amp; dosage</topic><topic>Antineoplastic Agents - therapeutic use</topic><topic>Catheterization - instrumentation</topic><topic>Catheterization - methods</topic><topic>Catheters, Indwelling</topic><topic>Central Nervous System Neoplasms - drug therapy</topic><topic>Clinical Study</topic><topic>Drug Delivery Systems - instrumentation</topic><topic>Drug Delivery Systems - methods</topic><topic>Female</topic><topic>Humans</topic><topic>Lymphoma - drug therapy</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Neuronavigation - methods</topic><topic>Neurosurgical Procedures - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Greenfield, Jeffrey P.</creatorcontrib><creatorcontrib>Schwartz, Theodore H.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><jtitle>Stereotactic and functional neurosurgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Greenfield, Jeffrey P.</au><au>Schwartz, Theodore H.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Catheter Placement for Ommaya Reservoirs with Frameless Surgical Navigation: Technical Note</atitle><jtitle>Stereotactic and functional neurosurgery</jtitle><addtitle>Stereotact Funct Neurosurg</addtitle><date>2008-01-01</date><risdate>2008</risdate><volume>86</volume><issue>2</issue><spage>101</spage><epage>105</epage><pages>101-105</pages><issn>1011-6125</issn><eissn>1423-0372</eissn><abstract>Objective: Infusion of intraventricular chemotherapy requires precise ventricular catheter placement in oncology patients to avoid intraparenchymal infusion. We assessed the safety and precision of using frameless surgical navigation for the placement of Ommaya reservoir catheters. Methods: In 20 consecutive patients who required Ommaya reservoirs for the administration of intrathecal chemotherapy, the catheters were positioned with the guidance of frameless stereotaxy. Precision of catheter placement, operative time, operative complications, and postoperative complications were assessed. Results: All catheters were completely within cerebrospinal fluid and 90% were within 5 mm of the intended target, the ipsilateral foramen of Monro. The average operative time was 47 min, and there were no intraoperative complications. There were no reports of leukoencephalopathy, and 3 patients had minor delayed complications. Conclusion: Frameless surgical navigation is a useful and efficient method for ensuring accurate catheter placement during Ommaya reservoir implantation, and it reduces the risk of potential parenchymal toxicity.</abstract><cop>Basel, Switzerland</cop><pmid>18073523</pmid><doi>10.1159/000112431</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1011-6125
ispartof Stereotactic and functional neurosurgery, 2008-01, Vol.86 (2), p.101-105
issn 1011-6125
1423-0372
language eng
recordid cdi_pubmed_primary_18073523
source MEDLINE; Karger Journals; Alma/SFX Local Collection
subjects Adult
Aged
Antineoplastic Agents - administration & dosage
Antineoplastic Agents - therapeutic use
Catheterization - instrumentation
Catheterization - methods
Catheters, Indwelling
Central Nervous System Neoplasms - drug therapy
Clinical Study
Drug Delivery Systems - instrumentation
Drug Delivery Systems - methods
Female
Humans
Lymphoma - drug therapy
Male
Middle Aged
Neuronavigation - methods
Neurosurgical Procedures - methods
title Catheter Placement for Ommaya Reservoirs with Frameless Surgical Navigation: Technical Note
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T05%3A48%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Catheter%20Placement%20for%20Ommaya%20Reservoirs%20with%20Frameless%20Surgical%20Navigation:%20Technical%20Note&rft.jtitle=Stereotactic%20and%20functional%20neurosurgery&rft.au=Greenfield,%20Jeffrey%20P.&rft.date=2008-01-01&rft.volume=86&rft.issue=2&rft.spage=101&rft.epage=105&rft.pages=101-105&rft.issn=1011-6125&rft.eissn=1423-0372&rft_id=info:doi/10.1159/000112431&rft_dat=%3Cpubmed_cross%3E18073523%3C/pubmed_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/18073523&rfr_iscdi=true