Comparing Properties of Audit Data and Routinely Collected Register Data in Case of Performance Assessment of Hip Fracture Treatment in Finland

Objectives: To compare prospective audit data and secondary administrative register data in the production of performance assessment information in the case of hip fracture treatment, and to cross-validate the quality of information. Methods: First, a conceptual model for the performance assessment...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Methods of information in medicine 2007, Vol.46 (5), p.558-566
Hauptverfasser: Sund, R, Nurmi-Lüthje, I, Lüthje, P, Tanninen, S, Narinen, A, Keskimäki, I
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 566
container_issue 5
container_start_page 558
container_title Methods of information in medicine
container_volume 46
creator Sund, R
Nurmi-Lüthje, I
Lüthje, P
Tanninen, S
Narinen, A
Keskimäki, I
description Objectives: To compare prospective audit data and secondary administrative register data in the production of performance assessment information in the case of hip fracture treatment, and to cross-validate the quality of information. Methods: First, a conceptual model for the performance assessment of hip fracture treatment was defined. This model was then utilized in comparisons between the prospective audit data concerning 106 consecutive hip fracture patients from the Kuusankoski Regional Hospital and corresponding register data from the Finnish Health Care Register and the Causes of Death Register. We examined the completeness of registration of patients and also the accuracy and degree of completeness of the registered data. Observed differences were checked against the medical records. Results: Register data lack clinical detail, but outperform prospective data in the recording of inpatient care history. Completeness of the register data is very good. The accuracy of easily measurable variables in the register is at least 95%. The agreement between register and audit data was 86.3% for detailed hip fracture diagnosis. Polyserial correlation between the functional dependency variables was 0.68. Conclusions: Register and audit data have certain limitations and problems, but both seem to be suitable for the performance assessment of hip fracture treatment. To improve the feasibility of the administrative register data, the voluntary input of additional hip fracture event data to the register should be made possible. Standardized instructions that guide the use of available register classifications in a sensible way would improve the quality of data.
doi_str_mv 10.1160/ME0382
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmed_primary_17938779</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>68402823</sourcerecordid><originalsourceid>FETCH-LOGICAL-c5282-1237e8e68829d3e052735694aad44e19ee00bba2a42e860cb6c25cb6139c85293</originalsourceid><addsrcrecordid>eNrFkc-KFDEQxhtR3HHVR5Bc9DaaTv9LH4fZXVdYcZEVvIWadM10lu6kTSUOOy_hG3jwSc04gysIXoWQQOqXr776kmXPc_46z2v-5v05L6R4kM1ElefzhlefH2YzzkU9z0XDT7InRLeccyl5-Tg7yZu2kE3TzrJvSzdO4I3dsGvvJvTBIDG3ZovYmcDOIAAD27GPLgZjcbhjSzcMqAOmO9wYCugPlLFsCYT7t9fo186PYDWyBRESjWjDvnJpJnbhQYfokd14hPCrkt5eGDukRk-zR2sYCJ8dz9Ps08X5zfJyfvXh7bvl4mquKyFFGqpoUGItpWi7AnklmqKq2xKgK0vMW0TOVysQUAqUNderWosq7XnRalmJtjjNXh10J---RKSgRkMah-QBXSRVy5KnRsU9qL0j8rhWkzcj-DuVc7WPXh2iT-CLo2JcjdjdY8esE_DyAITe4Ijq1kVv04x_C_04cKR7CAEi-t9ifQiT2m636o9ah_s1wgZ26YdUxBV6MroPaocmJNCbdUCrQO3UiKF3HSntbLoKpMDr3nxN86fswXfKEEVUNKE2MCRRG0l7MwW1T1pR77bJwzgkk9__t8m6Kf5h8Ccc8gxG</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68402823</pqid></control><display><type>article</type><title>Comparing Properties of Audit Data and Routinely Collected Register Data in Case of Performance Assessment of Hip Fracture Treatment in Finland</title><source>MEDLINE</source><source>Thieme Connect Journals</source><creator>Sund, R ; Nurmi-Lüthje, I ; Lüthje, P ; Tanninen, S ; Narinen, A ; Keskimäki, I</creator><creatorcontrib>Sund, R ; Nurmi-Lüthje, I ; Lüthje, P ; Tanninen, S ; Narinen, A ; Keskimäki, I</creatorcontrib><description>Objectives: To compare prospective audit data and secondary administrative register data in the production of performance assessment information in the case of hip fracture treatment, and to cross-validate the quality of information. Methods: First, a conceptual model for the performance assessment of hip fracture treatment was defined. This model was then utilized in comparisons between the prospective audit data concerning 106 consecutive hip fracture patients from the Kuusankoski Regional Hospital and corresponding register data from the Finnish Health Care Register and the Causes of Death Register. We examined the completeness of registration of patients and also the accuracy and degree of completeness of the registered data. Observed differences were checked against the medical records. Results: Register data lack clinical detail, but outperform prospective data in the recording of inpatient care history. Completeness of the register data is very good. The accuracy of easily measurable variables in the register is at least 95%. The agreement between register and audit data was 86.3% for detailed hip fracture diagnosis. Polyserial correlation between the functional dependency variables was 0.68. Conclusions: Register and audit data have certain limitations and problems, but both seem to be suitable for the performance assessment of hip fracture treatment. To improve the feasibility of the administrative register data, the voluntary input of additional hip fracture event data to the register should be made possible. Standardized instructions that guide the use of available register classifications in a sensible way would improve the quality of data.</description><identifier>ISSN: 0026-1270</identifier><identifier>EISSN: 2511-705X</identifier><identifier>DOI: 10.1160/ME0382</identifier><identifier>PMID: 17938779</identifier><language>eng</language><publisher>Germany: Schattauer Verlag für Medizin und Naturwissenschaften</publisher><subject>accuracy ; completeness ; conceptual model ; Finland ; Health Care Surveys ; Hip Fractures - diagnosis ; Hip Fractures - therapy ; Humans ; Information Systems ; Medical Audit ; Prospective Studies ; Registries ; Sensitivity and Specificity ; Validity</subject><ispartof>Methods of information in medicine, 2007, Vol.46 (5), p.558-566</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c5282-1237e8e68829d3e052735694aad44e19ee00bba2a42e860cb6c25cb6139c85293</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.thieme-connect.de/products/ejournals/pdf/10.1160/ME0382.pdf$$EPDF$$P50$$Gthieme$$H</linktopdf><linktohtml>$$Uhttps://www.thieme-connect.de/products/ejournals/html/10.1160/ME0382$$EHTML$$P50$$Gthieme$$H</linktohtml><link.rule.ids>314,778,782,3007,4012,27906,27907,27908,54542,54543</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/17938779$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sund, R</creatorcontrib><creatorcontrib>Nurmi-Lüthje, I</creatorcontrib><creatorcontrib>Lüthje, P</creatorcontrib><creatorcontrib>Tanninen, S</creatorcontrib><creatorcontrib>Narinen, A</creatorcontrib><creatorcontrib>Keskimäki, I</creatorcontrib><title>Comparing Properties of Audit Data and Routinely Collected Register Data in Case of Performance Assessment of Hip Fracture Treatment in Finland</title><title>Methods of information in medicine</title><addtitle>Methods Inf Med</addtitle><description>Objectives: To compare prospective audit data and secondary administrative register data in the production of performance assessment information in the case of hip fracture treatment, and to cross-validate the quality of information. Methods: First, a conceptual model for the performance assessment of hip fracture treatment was defined. This model was then utilized in comparisons between the prospective audit data concerning 106 consecutive hip fracture patients from the Kuusankoski Regional Hospital and corresponding register data from the Finnish Health Care Register and the Causes of Death Register. We examined the completeness of registration of patients and also the accuracy and degree of completeness of the registered data. Observed differences were checked against the medical records. Results: Register data lack clinical detail, but outperform prospective data in the recording of inpatient care history. Completeness of the register data is very good. The accuracy of easily measurable variables in the register is at least 95%. The agreement between register and audit data was 86.3% for detailed hip fracture diagnosis. Polyserial correlation between the functional dependency variables was 0.68. Conclusions: Register and audit data have certain limitations and problems, but both seem to be suitable for the performance assessment of hip fracture treatment. To improve the feasibility of the administrative register data, the voluntary input of additional hip fracture event data to the register should be made possible. Standardized instructions that guide the use of available register classifications in a sensible way would improve the quality of data.</description><subject>accuracy</subject><subject>completeness</subject><subject>conceptual model</subject><subject>Finland</subject><subject>Health Care Surveys</subject><subject>Hip Fractures - diagnosis</subject><subject>Hip Fractures - therapy</subject><subject>Humans</subject><subject>Information Systems</subject><subject>Medical Audit</subject><subject>Prospective Studies</subject><subject>Registries</subject><subject>Sensitivity and Specificity</subject><subject>Validity</subject><issn>0026-1270</issn><issn>2511-705X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNrFkc-KFDEQxhtR3HHVR5Bc9DaaTv9LH4fZXVdYcZEVvIWadM10lu6kTSUOOy_hG3jwSc04gysIXoWQQOqXr776kmXPc_46z2v-5v05L6R4kM1ElefzhlefH2YzzkU9z0XDT7InRLeccyl5-Tg7yZu2kE3TzrJvSzdO4I3dsGvvJvTBIDG3ZovYmcDOIAAD27GPLgZjcbhjSzcMqAOmO9wYCugPlLFsCYT7t9fo186PYDWyBRESjWjDvnJpJnbhQYfokd14hPCrkt5eGDukRk-zR2sYCJ8dz9Ps08X5zfJyfvXh7bvl4mquKyFFGqpoUGItpWi7AnklmqKq2xKgK0vMW0TOVysQUAqUNderWosq7XnRalmJtjjNXh10J---RKSgRkMah-QBXSRVy5KnRsU9qL0j8rhWkzcj-DuVc7WPXh2iT-CLo2JcjdjdY8esE_DyAITe4Ijq1kVv04x_C_04cKR7CAEi-t9ifQiT2m636o9ah_s1wgZ26YdUxBV6MroPaocmJNCbdUCrQO3UiKF3HSntbLoKpMDr3nxN86fswXfKEEVUNKE2MCRRG0l7MwW1T1pR77bJwzgkk9__t8m6Kf5h8Ccc8gxG</recordid><startdate>2007</startdate><enddate>2007</enddate><creator>Sund, R</creator><creator>Nurmi-Lüthje, I</creator><creator>Lüthje, P</creator><creator>Tanninen, S</creator><creator>Narinen, A</creator><creator>Keskimäki, I</creator><general>Schattauer Verlag für Medizin und Naturwissenschaften</general><general>Schattauer GmbH</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>2007</creationdate><title>Comparing Properties of Audit Data and Routinely Collected Register Data in Case of Performance Assessment of Hip Fracture Treatment in Finland</title><author>Sund, R ; Nurmi-Lüthje, I ; Lüthje, P ; Tanninen, S ; Narinen, A ; Keskimäki, I</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c5282-1237e8e68829d3e052735694aad44e19ee00bba2a42e860cb6c25cb6139c85293</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>accuracy</topic><topic>completeness</topic><topic>conceptual model</topic><topic>Finland</topic><topic>Health Care Surveys</topic><topic>Hip Fractures - diagnosis</topic><topic>Hip Fractures - therapy</topic><topic>Humans</topic><topic>Information Systems</topic><topic>Medical Audit</topic><topic>Prospective Studies</topic><topic>Registries</topic><topic>Sensitivity and Specificity</topic><topic>Validity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sund, R</creatorcontrib><creatorcontrib>Nurmi-Lüthje, I</creatorcontrib><creatorcontrib>Lüthje, P</creatorcontrib><creatorcontrib>Tanninen, S</creatorcontrib><creatorcontrib>Narinen, A</creatorcontrib><creatorcontrib>Keskimäki, I</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Methods of information in medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sund, R</au><au>Nurmi-Lüthje, I</au><au>Lüthje, P</au><au>Tanninen, S</au><au>Narinen, A</au><au>Keskimäki, I</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparing Properties of Audit Data and Routinely Collected Register Data in Case of Performance Assessment of Hip Fracture Treatment in Finland</atitle><jtitle>Methods of information in medicine</jtitle><addtitle>Methods Inf Med</addtitle><date>2007</date><risdate>2007</risdate><volume>46</volume><issue>5</issue><spage>558</spage><epage>566</epage><pages>558-566</pages><issn>0026-1270</issn><eissn>2511-705X</eissn><abstract>Objectives: To compare prospective audit data and secondary administrative register data in the production of performance assessment information in the case of hip fracture treatment, and to cross-validate the quality of information. Methods: First, a conceptual model for the performance assessment of hip fracture treatment was defined. This model was then utilized in comparisons between the prospective audit data concerning 106 consecutive hip fracture patients from the Kuusankoski Regional Hospital and corresponding register data from the Finnish Health Care Register and the Causes of Death Register. We examined the completeness of registration of patients and also the accuracy and degree of completeness of the registered data. Observed differences were checked against the medical records. Results: Register data lack clinical detail, but outperform prospective data in the recording of inpatient care history. Completeness of the register data is very good. The accuracy of easily measurable variables in the register is at least 95%. The agreement between register and audit data was 86.3% for detailed hip fracture diagnosis. Polyserial correlation between the functional dependency variables was 0.68. Conclusions: Register and audit data have certain limitations and problems, but both seem to be suitable for the performance assessment of hip fracture treatment. To improve the feasibility of the administrative register data, the voluntary input of additional hip fracture event data to the register should be made possible. Standardized instructions that guide the use of available register classifications in a sensible way would improve the quality of data.</abstract><cop>Germany</cop><pub>Schattauer Verlag für Medizin und Naturwissenschaften</pub><pmid>17938779</pmid><doi>10.1160/ME0382</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0026-1270
ispartof Methods of information in medicine, 2007, Vol.46 (5), p.558-566
issn 0026-1270
2511-705X
language eng
recordid cdi_pubmed_primary_17938779
source MEDLINE; Thieme Connect Journals
subjects accuracy
completeness
conceptual model
Finland
Health Care Surveys
Hip Fractures - diagnosis
Hip Fractures - therapy
Humans
Information Systems
Medical Audit
Prospective Studies
Registries
Sensitivity and Specificity
Validity
title Comparing Properties of Audit Data and Routinely Collected Register Data in Case of Performance Assessment of Hip Fracture Treatment in Finland
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T23%3A15%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparing%20Properties%20of%20Audit%20Data%20and%20Routinely%20Collected%20Register%20Data%20in%20Case%20of%20Performance%20Assessment%20of%20Hip%20Fracture%20Treatment%20in%20Finland&rft.jtitle=Methods%20of%20information%20in%20medicine&rft.au=Sund,%20R&rft.date=2007&rft.volume=46&rft.issue=5&rft.spage=558&rft.epage=566&rft.pages=558-566&rft.issn=0026-1270&rft.eissn=2511-705X&rft_id=info:doi/10.1160/ME0382&rft_dat=%3Cproquest_pubme%3E68402823%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=68402823&rft_id=info:pmid/17938779&rfr_iscdi=true