Comparison between Hilbert–Huang transform and scalogram methods on non-stationary biomedical signals: application to laser Doppler flowmetry recordings

A significant transient increase in laser Doppler flowmetry (LDF) signals is observed in response to a local and progressive cutaneous pressure application on healthy subjects. This reflex may be impaired in diabetic patients. The work presents a comparison between two signal processing methods that...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physics in medicine & biology 2005-11, Vol.50 (21), p.5189-5202
Hauptverfasser: Roulier, Rémy, Humeau, Anne, Flatley, Thomas P, Abraham, Pierre
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 5202
container_issue 21
container_start_page 5189
container_title Physics in medicine & biology
container_volume 50
creator Roulier, Rémy
Humeau, Anne
Flatley, Thomas P
Abraham, Pierre
description A significant transient increase in laser Doppler flowmetry (LDF) signals is observed in response to a local and progressive cutaneous pressure application on healthy subjects. This reflex may be impaired in diabetic patients. The work presents a comparison between two signal processing methods that provide a clarification of this phenomenon. Analyses by the scalogram and the Hilbert-Huang transform (HHT) of LDF signals recorded at rest and during a local and progressive cutaneous pressure application are performed on healthy and type 1 diabetic subjects. Three frequency bands, corresponding to myogenic, neurogenic and endothelial related metabolic activities, are studied at different time intervals in order to take into account the dynamics of the phenomenon. The results show that both the scalogram and the HHT methods lead to the same conclusions concerning the comparisons of the myogenic, neurogenic and endothelial related metabolic activities-during the progressive pressure and at rest-in healthy and diabetic subjects. However, the HHT shows more details that may be obscured by the scalogram. Indeed, the non-locally adaptative limitations of the scalogram can remove some definition from the data. These results may improve knowledge on the above-mentioned reflex as well as on non-stationary biomedical signal processing methods.
doi_str_mv 10.1088/0031-9155/50/21/016
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmed_primary_16237249</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>68704483</sourcerecordid><originalsourceid>FETCH-LOGICAL-c377t-8ed20dc2c7ce17d8e73dbab832bc6e8cca842846a4f15b7f9cc75a7a3d2611213</originalsourceid><addsrcrecordid>eNp9kcFuEzEURS0EomnhC5Aqr1ggTeNnz9gOOxQoqVSJDawtj-0JRjP21HZUses_sOvn8SV1lKhdFLF60vO513r3IvQOyAUQKZeEMGhW0HXLjiwpLAnwF2gBjEPDO05eosUjcYJOc_5FCICk7Wt0ApwyQdvVAt2v4zTr5HMMuHfl1rmAN37sXSp_7_5sdjpscUk65CGmCetgcTZ6jNukJzy58jPajKs0xNDkoouPQaffuPdxctZXEme_DXrMH7Ge57Fu9gguEY86u4Q_x7qtcxjjbbWr0uRMTNaHbX6DXg1V6d4e5xn6cfnl-3rTXH_7erX-dN0YJkRppLOUWEONMA6ElU4w2-teMtob7qQxWrZUtly3A3S9GFbGiE4LzSzlABTYGXp_8J1TvNm5XNTks3HjqIOLu6y4FKRtJasgO4AmxZyTG9Sc_FTvVUDUvhK1D1ztA1cdURRUraSqzo_2u76G8qQ5dlCBDwfAx_nx9R9OarZDhS-ew__7_gGtl6eS</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>68704483</pqid></control><display><type>article</type><title>Comparison between Hilbert–Huang transform and scalogram methods on non-stationary biomedical signals: application to laser Doppler flowmetry recordings</title><source>MEDLINE</source><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Roulier, Rémy ; Humeau, Anne ; Flatley, Thomas P ; Abraham, Pierre</creator><creatorcontrib>Roulier, Rémy ; Humeau, Anne ; Flatley, Thomas P ; Abraham, Pierre</creatorcontrib><description>A significant transient increase in laser Doppler flowmetry (LDF) signals is observed in response to a local and progressive cutaneous pressure application on healthy subjects. This reflex may be impaired in diabetic patients. The work presents a comparison between two signal processing methods that provide a clarification of this phenomenon. Analyses by the scalogram and the Hilbert-Huang transform (HHT) of LDF signals recorded at rest and during a local and progressive cutaneous pressure application are performed on healthy and type 1 diabetic subjects. Three frequency bands, corresponding to myogenic, neurogenic and endothelial related metabolic activities, are studied at different time intervals in order to take into account the dynamics of the phenomenon. The results show that both the scalogram and the HHT methods lead to the same conclusions concerning the comparisons of the myogenic, neurogenic and endothelial related metabolic activities-during the progressive pressure and at rest-in healthy and diabetic subjects. However, the HHT shows more details that may be obscured by the scalogram. Indeed, the non-locally adaptative limitations of the scalogram can remove some definition from the data. These results may improve knowledge on the above-mentioned reflex as well as on non-stationary biomedical signal processing methods.</description><identifier>ISSN: 0031-9155</identifier><identifier>EISSN: 1361-6560</identifier><identifier>DOI: 10.1088/0031-9155/50/21/016</identifier><identifier>PMID: 16237249</identifier><language>eng</language><publisher>England: IOP Publishing</publisher><subject>Algorithms ; Case-Control Studies ; Diabetes Mellitus, Type 1 - pathology ; Endothelium - metabolism ; Humans ; Laser-Doppler Flowmetry - methods ; Models, Statistical ; Muscles - pathology ; Neurons - metabolism ; Pressure ; Regional Blood Flow ; Signal Processing, Computer-Assisted ; Skin - pathology ; Skin Physiological Phenomena ; Time Factors</subject><ispartof>Physics in medicine &amp; biology, 2005-11, Vol.50 (21), p.5189-5202</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c377t-8ed20dc2c7ce17d8e73dbab832bc6e8cca842846a4f15b7f9cc75a7a3d2611213</citedby><cites>FETCH-LOGICAL-c377t-8ed20dc2c7ce17d8e73dbab832bc6e8cca842846a4f15b7f9cc75a7a3d2611213</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/0031-9155/50/21/016/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,780,784,27923,27924,53829,53909</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16237249$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Roulier, Rémy</creatorcontrib><creatorcontrib>Humeau, Anne</creatorcontrib><creatorcontrib>Flatley, Thomas P</creatorcontrib><creatorcontrib>Abraham, Pierre</creatorcontrib><title>Comparison between Hilbert–Huang transform and scalogram methods on non-stationary biomedical signals: application to laser Doppler flowmetry recordings</title><title>Physics in medicine &amp; biology</title><addtitle>Phys Med Biol</addtitle><description>A significant transient increase in laser Doppler flowmetry (LDF) signals is observed in response to a local and progressive cutaneous pressure application on healthy subjects. This reflex may be impaired in diabetic patients. The work presents a comparison between two signal processing methods that provide a clarification of this phenomenon. Analyses by the scalogram and the Hilbert-Huang transform (HHT) of LDF signals recorded at rest and during a local and progressive cutaneous pressure application are performed on healthy and type 1 diabetic subjects. Three frequency bands, corresponding to myogenic, neurogenic and endothelial related metabolic activities, are studied at different time intervals in order to take into account the dynamics of the phenomenon. The results show that both the scalogram and the HHT methods lead to the same conclusions concerning the comparisons of the myogenic, neurogenic and endothelial related metabolic activities-during the progressive pressure and at rest-in healthy and diabetic subjects. However, the HHT shows more details that may be obscured by the scalogram. Indeed, the non-locally adaptative limitations of the scalogram can remove some definition from the data. These results may improve knowledge on the above-mentioned reflex as well as on non-stationary biomedical signal processing methods.</description><subject>Algorithms</subject><subject>Case-Control Studies</subject><subject>Diabetes Mellitus, Type 1 - pathology</subject><subject>Endothelium - metabolism</subject><subject>Humans</subject><subject>Laser-Doppler Flowmetry - methods</subject><subject>Models, Statistical</subject><subject>Muscles - pathology</subject><subject>Neurons - metabolism</subject><subject>Pressure</subject><subject>Regional Blood Flow</subject><subject>Signal Processing, Computer-Assisted</subject><subject>Skin - pathology</subject><subject>Skin Physiological Phenomena</subject><subject>Time Factors</subject><issn>0031-9155</issn><issn>1361-6560</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kcFuEzEURS0EomnhC5Aqr1ggTeNnz9gOOxQoqVSJDawtj-0JRjP21HZUses_sOvn8SV1lKhdFLF60vO513r3IvQOyAUQKZeEMGhW0HXLjiwpLAnwF2gBjEPDO05eosUjcYJOc_5FCICk7Wt0ApwyQdvVAt2v4zTr5HMMuHfl1rmAN37sXSp_7_5sdjpscUk65CGmCetgcTZ6jNukJzy58jPajKs0xNDkoouPQaffuPdxctZXEme_DXrMH7Ge57Fu9gguEY86u4Q_x7qtcxjjbbWr0uRMTNaHbX6DXg1V6d4e5xn6cfnl-3rTXH_7erX-dN0YJkRppLOUWEONMA6ElU4w2-teMtob7qQxWrZUtly3A3S9GFbGiE4LzSzlABTYGXp_8J1TvNm5XNTks3HjqIOLu6y4FKRtJasgO4AmxZyTG9Sc_FTvVUDUvhK1D1ztA1cdURRUraSqzo_2u76G8qQ5dlCBDwfAx_nx9R9OarZDhS-ew__7_gGtl6eS</recordid><startdate>20051107</startdate><enddate>20051107</enddate><creator>Roulier, Rémy</creator><creator>Humeau, Anne</creator><creator>Flatley, Thomas P</creator><creator>Abraham, Pierre</creator><general>IOP Publishing</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20051107</creationdate><title>Comparison between Hilbert–Huang transform and scalogram methods on non-stationary biomedical signals: application to laser Doppler flowmetry recordings</title><author>Roulier, Rémy ; Humeau, Anne ; Flatley, Thomas P ; Abraham, Pierre</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c377t-8ed20dc2c7ce17d8e73dbab832bc6e8cca842846a4f15b7f9cc75a7a3d2611213</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Algorithms</topic><topic>Case-Control Studies</topic><topic>Diabetes Mellitus, Type 1 - pathology</topic><topic>Endothelium - metabolism</topic><topic>Humans</topic><topic>Laser-Doppler Flowmetry - methods</topic><topic>Models, Statistical</topic><topic>Muscles - pathology</topic><topic>Neurons - metabolism</topic><topic>Pressure</topic><topic>Regional Blood Flow</topic><topic>Signal Processing, Computer-Assisted</topic><topic>Skin - pathology</topic><topic>Skin Physiological Phenomena</topic><topic>Time Factors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Roulier, Rémy</creatorcontrib><creatorcontrib>Humeau, Anne</creatorcontrib><creatorcontrib>Flatley, Thomas P</creatorcontrib><creatorcontrib>Abraham, Pierre</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Physics in medicine &amp; biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Roulier, Rémy</au><au>Humeau, Anne</au><au>Flatley, Thomas P</au><au>Abraham, Pierre</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison between Hilbert–Huang transform and scalogram methods on non-stationary biomedical signals: application to laser Doppler flowmetry recordings</atitle><jtitle>Physics in medicine &amp; biology</jtitle><addtitle>Phys Med Biol</addtitle><date>2005-11-07</date><risdate>2005</risdate><volume>50</volume><issue>21</issue><spage>5189</spage><epage>5202</epage><pages>5189-5202</pages><issn>0031-9155</issn><eissn>1361-6560</eissn><abstract>A significant transient increase in laser Doppler flowmetry (LDF) signals is observed in response to a local and progressive cutaneous pressure application on healthy subjects. This reflex may be impaired in diabetic patients. The work presents a comparison between two signal processing methods that provide a clarification of this phenomenon. Analyses by the scalogram and the Hilbert-Huang transform (HHT) of LDF signals recorded at rest and during a local and progressive cutaneous pressure application are performed on healthy and type 1 diabetic subjects. Three frequency bands, corresponding to myogenic, neurogenic and endothelial related metabolic activities, are studied at different time intervals in order to take into account the dynamics of the phenomenon. The results show that both the scalogram and the HHT methods lead to the same conclusions concerning the comparisons of the myogenic, neurogenic and endothelial related metabolic activities-during the progressive pressure and at rest-in healthy and diabetic subjects. However, the HHT shows more details that may be obscured by the scalogram. Indeed, the non-locally adaptative limitations of the scalogram can remove some definition from the data. These results may improve knowledge on the above-mentioned reflex as well as on non-stationary biomedical signal processing methods.</abstract><cop>England</cop><pub>IOP Publishing</pub><pmid>16237249</pmid><doi>10.1088/0031-9155/50/21/016</doi><tpages>14</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0031-9155
ispartof Physics in medicine & biology, 2005-11, Vol.50 (21), p.5189-5202
issn 0031-9155
1361-6560
language eng
recordid cdi_pubmed_primary_16237249
source MEDLINE; IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
subjects Algorithms
Case-Control Studies
Diabetes Mellitus, Type 1 - pathology
Endothelium - metabolism
Humans
Laser-Doppler Flowmetry - methods
Models, Statistical
Muscles - pathology
Neurons - metabolism
Pressure
Regional Blood Flow
Signal Processing, Computer-Assisted
Skin - pathology
Skin Physiological Phenomena
Time Factors
title Comparison between Hilbert–Huang transform and scalogram methods on non-stationary biomedical signals: application to laser Doppler flowmetry recordings
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T15%3A26%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20between%20Hilbert%E2%80%93Huang%20transform%20and%20scalogram%20methods%20on%20non-stationary%20biomedical%20signals:%20application%20to%20laser%20Doppler%20flowmetry%20recordings&rft.jtitle=Physics%20in%20medicine%20&%20biology&rft.au=Roulier,%20R%C3%A9my&rft.date=2005-11-07&rft.volume=50&rft.issue=21&rft.spage=5189&rft.epage=5202&rft.pages=5189-5202&rft.issn=0031-9155&rft.eissn=1361-6560&rft_id=info:doi/10.1088/0031-9155/50/21/016&rft_dat=%3Cproquest_pubme%3E68704483%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=68704483&rft_id=info:pmid/16237249&rfr_iscdi=true