Performance of a Portable Whole-Body Mouse Exposure System

A mobile whole-body exposure system was developed for exposing mice to concentrated ambient particulate matter smaller than 2.5 μm in mass median aerodynamic diameter (MMAD). Each 20-L exposure cage was designed to hold 9 mice within individual compartments. This allowed for transport and subsequent...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Inhalation toxicology 2004-08, Vol.16 (9), p.657-662
Hauptverfasser: Oldham, Michael J., Phalen, Robert F., Robinson, Risa J., Kleinman, Michael T.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 662
container_issue 9
container_start_page 657
container_title Inhalation toxicology
container_volume 16
creator Oldham, Michael J.
Phalen, Robert F.
Robinson, Risa J.
Kleinman, Michael T.
description A mobile whole-body exposure system was developed for exposing mice to concentrated ambient particulate matter smaller than 2.5 μm in mass median aerodynamic diameter (MMAD). Each 20-L exposure cage was designed to hold 9 mice within individual compartments. This allowed for transport and subsequent exposure. Airflow mixing and the potential for stagnant areas within the compartments were modeled using computational fluid dynamic modeling (CFD). CFD analysis showed no stagnant areas and good mixing throughout the exposure cage. The actual performance of the exposure system was determined for 0.5 to 2.0 μm diameter aerosols by measuring (1) uniformity of aerosol distribution and (2) particle deposition in the tracheobronchial and pulmonary regions of mice exposed in the system. A 0.6-μm MMAD (GSD = 2.0) cigarette smoke aerosol was used to experimentally measure the uniformity of aerosol distribution to the nine individual compartments. The average data from three runs showed no statistically significant difference among individual compartments. Particle deposition efficiency in adult male BALB/c mice was measured after exposure (30 min) in the system using monodisperse fluorescent polystyrene latex particles (0.5, 1, and 2 μm aerodynamic diameter). The measured deposition efficiency in this mobile exposure system for the combined tracheobronchial and pulmonary regions of the adult male BALBc mice was 21% for 0.5 μm, 11% for 1.0 μm, and 6.5% for 2.0 μm particles. These deposition efficiencies are similar to those reported for mice exposed in a nose-only exposure system, which indicates that particle losses to animal fur and exposure system surfaces were acceptable.
doi_str_mv 10.1080/08958370490464670
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmed_primary_16036757</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>17759381</sourcerecordid><originalsourceid>FETCH-LOGICAL-c507t-b56f3a50e9a93907670153946406c4e9652f44878853e30695494ddb53009f0e3</originalsourceid><addsrcrecordid>eNqFkEtLAzEUhYMotj5-gBuZlbvRG_OaqBst9QEVCyouQzpzh7bMNDWZQfvvTW1BRKiru7jfORw-Qo4onFLI4AwyLTKmgGvgkksFW6RLQdNUSU23SXf5TyOQdcheCFMAkMDULunQeKUSqksuhuhL52s7yzFxZWKTofONHVWYvI1dhemNKxbJo2sDJv3PuQutx-R5ERqsD8hOaauAh-u7T15v-y-9-3TwdPfQux6kuQDVpCMhS2YFoLaaaVBxJhVMx8Egc45aivOS80xlmWDIQGrBNS-KkWAAugRk--Rk1Tv37r3F0Jh6EnKsKjvDuMtQpYRmGf0f5CpaozyCdAXm3oXgsTRzP6mtXxgKZmnW_DEbM8fr8nZUY_GTWKuMwNUKmMy-hX44XxWmsYvK-dJHv5Ng2Kb-y1_xMdqqGefWo5m61s-i4Q3rvgCXaZWd</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>14708014</pqid></control><display><type>article</type><title>Performance of a Portable Whole-Body Mouse Exposure System</title><source>MEDLINE</source><source>Taylor &amp; Francis Medical Library - CRKN</source><source>Taylor &amp; Francis Journals Complete</source><creator>Oldham, Michael J. ; Phalen, Robert F. ; Robinson, Risa J. ; Kleinman, Michael T.</creator><creatorcontrib>Oldham, Michael J. ; Phalen, Robert F. ; Robinson, Risa J. ; Kleinman, Michael T.</creatorcontrib><description>A mobile whole-body exposure system was developed for exposing mice to concentrated ambient particulate matter smaller than 2.5 μm in mass median aerodynamic diameter (MMAD). Each 20-L exposure cage was designed to hold 9 mice within individual compartments. This allowed for transport and subsequent exposure. Airflow mixing and the potential for stagnant areas within the compartments were modeled using computational fluid dynamic modeling (CFD). CFD analysis showed no stagnant areas and good mixing throughout the exposure cage. The actual performance of the exposure system was determined for 0.5 to 2.0 μm diameter aerosols by measuring (1) uniformity of aerosol distribution and (2) particle deposition in the tracheobronchial and pulmonary regions of mice exposed in the system. A 0.6-μm MMAD (GSD = 2.0) cigarette smoke aerosol was used to experimentally measure the uniformity of aerosol distribution to the nine individual compartments. The average data from three runs showed no statistically significant difference among individual compartments. Particle deposition efficiency in adult male BALB/c mice was measured after exposure (30 min) in the system using monodisperse fluorescent polystyrene latex particles (0.5, 1, and 2 μm aerodynamic diameter). The measured deposition efficiency in this mobile exposure system for the combined tracheobronchial and pulmonary regions of the adult male BALBc mice was 21% for 0.5 μm, 11% for 1.0 μm, and 6.5% for 2.0 μm particles. These deposition efficiencies are similar to those reported for mice exposed in a nose-only exposure system, which indicates that particle losses to animal fur and exposure system surfaces were acceptable.</description><identifier>ISSN: 0895-8378</identifier><identifier>EISSN: 1091-7691</identifier><identifier>DOI: 10.1080/08958370490464670</identifier><identifier>PMID: 16036757</identifier><language>eng</language><publisher>England: Informa UK Ltd</publisher><subject>Aerosols ; Air Pollutants ; Animals ; Atmosphere Exposure Chambers ; Inhalation Exposure ; Male ; Mice ; Mice, Inbred BALB C ; Nicotiana ; Particle Size ; Smoke - analysis</subject><ispartof>Inhalation toxicology, 2004-08, Vol.16 (9), p.657-662</ispartof><rights>2004 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted 2004</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c507t-b56f3a50e9a93907670153946406c4e9652f44878853e30695494ddb53009f0e3</citedby><cites>FETCH-LOGICAL-c507t-b56f3a50e9a93907670153946406c4e9652f44878853e30695494ddb53009f0e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.tandfonline.com/doi/pdf/10.1080/08958370490464670$$EPDF$$P50$$Ginformahealthcare$$H</linktopdf><linktohtml>$$Uhttps://www.tandfonline.com/doi/full/10.1080/08958370490464670$$EHTML$$P50$$Ginformahealthcare$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,59647,59753,60436,60542,61221,61256,61402,61437</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/16036757$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Oldham, Michael J.</creatorcontrib><creatorcontrib>Phalen, Robert F.</creatorcontrib><creatorcontrib>Robinson, Risa J.</creatorcontrib><creatorcontrib>Kleinman, Michael T.</creatorcontrib><title>Performance of a Portable Whole-Body Mouse Exposure System</title><title>Inhalation toxicology</title><addtitle>Inhal Toxicol</addtitle><description>A mobile whole-body exposure system was developed for exposing mice to concentrated ambient particulate matter smaller than 2.5 μm in mass median aerodynamic diameter (MMAD). Each 20-L exposure cage was designed to hold 9 mice within individual compartments. This allowed for transport and subsequent exposure. Airflow mixing and the potential for stagnant areas within the compartments were modeled using computational fluid dynamic modeling (CFD). CFD analysis showed no stagnant areas and good mixing throughout the exposure cage. The actual performance of the exposure system was determined for 0.5 to 2.0 μm diameter aerosols by measuring (1) uniformity of aerosol distribution and (2) particle deposition in the tracheobronchial and pulmonary regions of mice exposed in the system. A 0.6-μm MMAD (GSD = 2.0) cigarette smoke aerosol was used to experimentally measure the uniformity of aerosol distribution to the nine individual compartments. The average data from three runs showed no statistically significant difference among individual compartments. Particle deposition efficiency in adult male BALB/c mice was measured after exposure (30 min) in the system using monodisperse fluorescent polystyrene latex particles (0.5, 1, and 2 μm aerodynamic diameter). The measured deposition efficiency in this mobile exposure system for the combined tracheobronchial and pulmonary regions of the adult male BALBc mice was 21% for 0.5 μm, 11% for 1.0 μm, and 6.5% for 2.0 μm particles. These deposition efficiencies are similar to those reported for mice exposed in a nose-only exposure system, which indicates that particle losses to animal fur and exposure system surfaces were acceptable.</description><subject>Aerosols</subject><subject>Air Pollutants</subject><subject>Animals</subject><subject>Atmosphere Exposure Chambers</subject><subject>Inhalation Exposure</subject><subject>Male</subject><subject>Mice</subject><subject>Mice, Inbred BALB C</subject><subject>Nicotiana</subject><subject>Particle Size</subject><subject>Smoke - analysis</subject><issn>0895-8378</issn><issn>1091-7691</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkEtLAzEUhYMotj5-gBuZlbvRG_OaqBst9QEVCyouQzpzh7bMNDWZQfvvTW1BRKiru7jfORw-Qo4onFLI4AwyLTKmgGvgkksFW6RLQdNUSU23SXf5TyOQdcheCFMAkMDULunQeKUSqksuhuhL52s7yzFxZWKTofONHVWYvI1dhemNKxbJo2sDJv3PuQutx-R5ERqsD8hOaauAh-u7T15v-y-9-3TwdPfQux6kuQDVpCMhS2YFoLaaaVBxJhVMx8Egc45aivOS80xlmWDIQGrBNS-KkWAAugRk--Rk1Tv37r3F0Jh6EnKsKjvDuMtQpYRmGf0f5CpaozyCdAXm3oXgsTRzP6mtXxgKZmnW_DEbM8fr8nZUY_GTWKuMwNUKmMy-hX44XxWmsYvK-dJHv5Ng2Kb-y1_xMdqqGefWo5m61s-i4Q3rvgCXaZWd</recordid><startdate>20040801</startdate><enddate>20040801</enddate><creator>Oldham, Michael J.</creator><creator>Phalen, Robert F.</creator><creator>Robinson, Risa J.</creator><creator>Kleinman, Michael T.</creator><general>Informa UK Ltd</general><general>Taylor &amp; Francis</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope><scope>7U7</scope></search><sort><creationdate>20040801</creationdate><title>Performance of a Portable Whole-Body Mouse Exposure System</title><author>Oldham, Michael J. ; Phalen, Robert F. ; Robinson, Risa J. ; Kleinman, Michael T.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c507t-b56f3a50e9a93907670153946406c4e9652f44878853e30695494ddb53009f0e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Aerosols</topic><topic>Air Pollutants</topic><topic>Animals</topic><topic>Atmosphere Exposure Chambers</topic><topic>Inhalation Exposure</topic><topic>Male</topic><topic>Mice</topic><topic>Mice, Inbred BALB C</topic><topic>Nicotiana</topic><topic>Particle Size</topic><topic>Smoke - analysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Oldham, Michael J.</creatorcontrib><creatorcontrib>Phalen, Robert F.</creatorcontrib><creatorcontrib>Robinson, Risa J.</creatorcontrib><creatorcontrib>Kleinman, Michael T.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><collection>Toxicology Abstracts</collection><jtitle>Inhalation toxicology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Oldham, Michael J.</au><au>Phalen, Robert F.</au><au>Robinson, Risa J.</au><au>Kleinman, Michael T.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Performance of a Portable Whole-Body Mouse Exposure System</atitle><jtitle>Inhalation toxicology</jtitle><addtitle>Inhal Toxicol</addtitle><date>2004-08-01</date><risdate>2004</risdate><volume>16</volume><issue>9</issue><spage>657</spage><epage>662</epage><pages>657-662</pages><issn>0895-8378</issn><eissn>1091-7691</eissn><abstract>A mobile whole-body exposure system was developed for exposing mice to concentrated ambient particulate matter smaller than 2.5 μm in mass median aerodynamic diameter (MMAD). Each 20-L exposure cage was designed to hold 9 mice within individual compartments. This allowed for transport and subsequent exposure. Airflow mixing and the potential for stagnant areas within the compartments were modeled using computational fluid dynamic modeling (CFD). CFD analysis showed no stagnant areas and good mixing throughout the exposure cage. The actual performance of the exposure system was determined for 0.5 to 2.0 μm diameter aerosols by measuring (1) uniformity of aerosol distribution and (2) particle deposition in the tracheobronchial and pulmonary regions of mice exposed in the system. A 0.6-μm MMAD (GSD = 2.0) cigarette smoke aerosol was used to experimentally measure the uniformity of aerosol distribution to the nine individual compartments. The average data from three runs showed no statistically significant difference among individual compartments. Particle deposition efficiency in adult male BALB/c mice was measured after exposure (30 min) in the system using monodisperse fluorescent polystyrene latex particles (0.5, 1, and 2 μm aerodynamic diameter). The measured deposition efficiency in this mobile exposure system for the combined tracheobronchial and pulmonary regions of the adult male BALBc mice was 21% for 0.5 μm, 11% for 1.0 μm, and 6.5% for 2.0 μm particles. These deposition efficiencies are similar to those reported for mice exposed in a nose-only exposure system, which indicates that particle losses to animal fur and exposure system surfaces were acceptable.</abstract><cop>England</cop><pub>Informa UK Ltd</pub><pmid>16036757</pmid><doi>10.1080/08958370490464670</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0895-8378
ispartof Inhalation toxicology, 2004-08, Vol.16 (9), p.657-662
issn 0895-8378
1091-7691
language eng
recordid cdi_pubmed_primary_16036757
source MEDLINE; Taylor & Francis Medical Library - CRKN; Taylor & Francis Journals Complete
subjects Aerosols
Air Pollutants
Animals
Atmosphere Exposure Chambers
Inhalation Exposure
Male
Mice
Mice, Inbred BALB C
Nicotiana
Particle Size
Smoke - analysis
title Performance of a Portable Whole-Body Mouse Exposure System
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-30T18%3A29%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Performance%20of%20a%20Portable%20Whole-Body%20Mouse%20Exposure%20System&rft.jtitle=Inhalation%20toxicology&rft.au=Oldham,%20Michael%20J.&rft.date=2004-08-01&rft.volume=16&rft.issue=9&rft.spage=657&rft.epage=662&rft.pages=657-662&rft.issn=0895-8378&rft.eissn=1091-7691&rft_id=info:doi/10.1080/08958370490464670&rft_dat=%3Cproquest_pubme%3E17759381%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=14708014&rft_id=info:pmid/16036757&rfr_iscdi=true